The implication of initial 24-core transrectal prostate biopsy protocol on the detection of significant prostate cancer and high grade prostatic intraepithelial neoplasia

Detalhes bibliográficos
Autor(a) principal: Nomikos,Michael
Data de Publicação: 2011
Outros Autores: Karyotis,Ioannis, Phillipou,Prodromos, Constadinides,Charalambos, Delakas,Dimitrios
Tipo de documento: Artigo
Idioma: eng
Título da fonte: International Braz J Urol (Online)
Texto Completo: http://old.scielo.br/scielo.php?script=sci_arttext&pid=S1677-55382011000100011
Resumo: PURPOSE: To assess the diagnostic value of an initial 24-sample transrectal ultrasound guided (TRUS) prostate biopsy protocol compared to the 10-core technique. MATERIALS AND METHODS: We retrospectively reviewed the prostate biopsy database of consecutive men undergoing prostate biopsies under local anesthesia by using the 10 (Group A) and 24 (Group B) protocols. Men were stratified according to biopsy protocol and PSA levels. Exclusion criteria were age = 75 years and PSA &gt; 20 ng/mL. The Mann-Whitney U and Fisher's exact test were used for statistical analysis. RESULTS: Between April 2007 and August 2009, 869 men underwent TRUS prostate biopsies of which 379 were eligible for the study. Group A (10-cores) consisted of 243 (64.11%) men and group B (24-cores) included 139 (35.89%) men. The overall prostate cancer detection rate was 39.09% and 34.55% in Group A and B, respectively (p = 0.43). An overall 9.8% increase in Gleason 7 detection rate was found in Group B (p = 0.24). The high-grade prostatic intraepithelial neoplasia (HGPIN) detection rate in men with negative initial biopsies was 15.54% and 35.55% in Group A and B, respectively (p < 0.001). In patients with PSA < 10 ng/mL, the 24-core technique increased Gleason 7 detection rate by 13.4 % (p = 0.16) and HGPIN by 23.4% (p = 0.0008), compared to the 10 core technique. The 24-core technique increased the concordance between needle biopsy and prostatectomy specimen compared to 10-core technique (p < 0.002). CONCLUSIONS: The initial 24-core prostate biopsy protocol did not show any benefit in the detection of prostate cancer compared to the 10-core technique. However, it improved the HGPIN detection and the correlation between biopsy results and radical prostatectomy Gleason score in men with lower PSA levels.
id SBU-1_95c7ecb041e2d614ac0848bf65779140
oai_identifier_str oai:scielo:S1677-55382011000100011
network_acronym_str SBU-1
network_name_str International Braz J Urol (Online)
repository_id_str
spelling The implication of initial 24-core transrectal prostate biopsy protocol on the detection of significant prostate cancer and high grade prostatic intraepithelial neoplasiaprostatic neoplasmbiopsyGleason scoreprostatic intraepithelial neoplasiaPURPOSE: To assess the diagnostic value of an initial 24-sample transrectal ultrasound guided (TRUS) prostate biopsy protocol compared to the 10-core technique. MATERIALS AND METHODS: We retrospectively reviewed the prostate biopsy database of consecutive men undergoing prostate biopsies under local anesthesia by using the 10 (Group A) and 24 (Group B) protocols. Men were stratified according to biopsy protocol and PSA levels. Exclusion criteria were age = 75 years and PSA &gt; 20 ng/mL. The Mann-Whitney U and Fisher's exact test were used for statistical analysis. RESULTS: Between April 2007 and August 2009, 869 men underwent TRUS prostate biopsies of which 379 were eligible for the study. Group A (10-cores) consisted of 243 (64.11%) men and group B (24-cores) included 139 (35.89%) men. The overall prostate cancer detection rate was 39.09% and 34.55% in Group A and B, respectively (p = 0.43). An overall 9.8% increase in Gleason 7 detection rate was found in Group B (p = 0.24). The high-grade prostatic intraepithelial neoplasia (HGPIN) detection rate in men with negative initial biopsies was 15.54% and 35.55% in Group A and B, respectively (p < 0.001). In patients with PSA < 10 ng/mL, the 24-core technique increased Gleason 7 detection rate by 13.4 % (p = 0.16) and HGPIN by 23.4% (p = 0.0008), compared to the 10 core technique. The 24-core technique increased the concordance between needle biopsy and prostatectomy specimen compared to 10-core technique (p < 0.002). CONCLUSIONS: The initial 24-core prostate biopsy protocol did not show any benefit in the detection of prostate cancer compared to the 10-core technique. However, it improved the HGPIN detection and the correlation between biopsy results and radical prostatectomy Gleason score in men with lower PSA levels.Sociedade Brasileira de Urologia2011-02-01info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersiontext/htmlhttp://old.scielo.br/scielo.php?script=sci_arttext&pid=S1677-55382011000100011International braz j urol v.37 n.1 2011reponame:International Braz J Urol (Online)instname:Sociedade Brasileira de Urologia (SBU)instacron:SBU10.1590/S1677-55382011000100011info:eu-repo/semantics/openAccessNomikos,MichaelKaryotis,IoannisPhillipou,ProdromosConstadinides,CharalambosDelakas,Dimitrioseng2011-03-30T00:00:00Zoai:scielo:S1677-55382011000100011Revistahttp://www.brazjurol.com.br/ONGhttps://old.scielo.br/oai/scielo-oai.php||brazjurol@brazjurol.com.br1677-61191677-5538opendoar:2011-03-30T00:00International Braz J Urol (Online) - Sociedade Brasileira de Urologia (SBU)false
dc.title.none.fl_str_mv The implication of initial 24-core transrectal prostate biopsy protocol on the detection of significant prostate cancer and high grade prostatic intraepithelial neoplasia
title The implication of initial 24-core transrectal prostate biopsy protocol on the detection of significant prostate cancer and high grade prostatic intraepithelial neoplasia
spellingShingle The implication of initial 24-core transrectal prostate biopsy protocol on the detection of significant prostate cancer and high grade prostatic intraepithelial neoplasia
Nomikos,Michael
prostatic neoplasm
biopsy
Gleason score
prostatic intraepithelial neoplasia
title_short The implication of initial 24-core transrectal prostate biopsy protocol on the detection of significant prostate cancer and high grade prostatic intraepithelial neoplasia
title_full The implication of initial 24-core transrectal prostate biopsy protocol on the detection of significant prostate cancer and high grade prostatic intraepithelial neoplasia
title_fullStr The implication of initial 24-core transrectal prostate biopsy protocol on the detection of significant prostate cancer and high grade prostatic intraepithelial neoplasia
title_full_unstemmed The implication of initial 24-core transrectal prostate biopsy protocol on the detection of significant prostate cancer and high grade prostatic intraepithelial neoplasia
title_sort The implication of initial 24-core transrectal prostate biopsy protocol on the detection of significant prostate cancer and high grade prostatic intraepithelial neoplasia
author Nomikos,Michael
author_facet Nomikos,Michael
Karyotis,Ioannis
Phillipou,Prodromos
Constadinides,Charalambos
Delakas,Dimitrios
author_role author
author2 Karyotis,Ioannis
Phillipou,Prodromos
Constadinides,Charalambos
Delakas,Dimitrios
author2_role author
author
author
author
dc.contributor.author.fl_str_mv Nomikos,Michael
Karyotis,Ioannis
Phillipou,Prodromos
Constadinides,Charalambos
Delakas,Dimitrios
dc.subject.por.fl_str_mv prostatic neoplasm
biopsy
Gleason score
prostatic intraepithelial neoplasia
topic prostatic neoplasm
biopsy
Gleason score
prostatic intraepithelial neoplasia
description PURPOSE: To assess the diagnostic value of an initial 24-sample transrectal ultrasound guided (TRUS) prostate biopsy protocol compared to the 10-core technique. MATERIALS AND METHODS: We retrospectively reviewed the prostate biopsy database of consecutive men undergoing prostate biopsies under local anesthesia by using the 10 (Group A) and 24 (Group B) protocols. Men were stratified according to biopsy protocol and PSA levels. Exclusion criteria were age = 75 years and PSA &gt; 20 ng/mL. The Mann-Whitney U and Fisher's exact test were used for statistical analysis. RESULTS: Between April 2007 and August 2009, 869 men underwent TRUS prostate biopsies of which 379 were eligible for the study. Group A (10-cores) consisted of 243 (64.11%) men and group B (24-cores) included 139 (35.89%) men. The overall prostate cancer detection rate was 39.09% and 34.55% in Group A and B, respectively (p = 0.43). An overall 9.8% increase in Gleason 7 detection rate was found in Group B (p = 0.24). The high-grade prostatic intraepithelial neoplasia (HGPIN) detection rate in men with negative initial biopsies was 15.54% and 35.55% in Group A and B, respectively (p < 0.001). In patients with PSA < 10 ng/mL, the 24-core technique increased Gleason 7 detection rate by 13.4 % (p = 0.16) and HGPIN by 23.4% (p = 0.0008), compared to the 10 core technique. The 24-core technique increased the concordance between needle biopsy and prostatectomy specimen compared to 10-core technique (p < 0.002). CONCLUSIONS: The initial 24-core prostate biopsy protocol did not show any benefit in the detection of prostate cancer compared to the 10-core technique. However, it improved the HGPIN detection and the correlation between biopsy results and radical prostatectomy Gleason score in men with lower PSA levels.
publishDate 2011
dc.date.none.fl_str_mv 2011-02-01
dc.type.driver.fl_str_mv info:eu-repo/semantics/article
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
format article
status_str publishedVersion
dc.identifier.uri.fl_str_mv http://old.scielo.br/scielo.php?script=sci_arttext&pid=S1677-55382011000100011
url http://old.scielo.br/scielo.php?script=sci_arttext&pid=S1677-55382011000100011
dc.language.iso.fl_str_mv eng
language eng
dc.relation.none.fl_str_mv 10.1590/S1677-55382011000100011
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv text/html
dc.publisher.none.fl_str_mv Sociedade Brasileira de Urologia
publisher.none.fl_str_mv Sociedade Brasileira de Urologia
dc.source.none.fl_str_mv International braz j urol v.37 n.1 2011
reponame:International Braz J Urol (Online)
instname:Sociedade Brasileira de Urologia (SBU)
instacron:SBU
instname_str Sociedade Brasileira de Urologia (SBU)
instacron_str SBU
institution SBU
reponame_str International Braz J Urol (Online)
collection International Braz J Urol (Online)
repository.name.fl_str_mv International Braz J Urol (Online) - Sociedade Brasileira de Urologia (SBU)
repository.mail.fl_str_mv ||brazjurol@brazjurol.com.br
_version_ 1750318072001986560