Infrared Thermometer: an accurate tool for temperature measurement during renal surgery

Detalhes bibliográficos
Autor(a) principal: Marchini,Giovanni Scala
Data de Publicação: 2013
Outros Autores: Duarte,Ricardo Jordao, Mitre,Anuar Ibrahim, Tiseo,Bruno Camargo, Cassao,Valter Dell'Acqua, Torricelli,Fabio Cesar Miranda, Arap,Marco Antonio, Srougi,Miguel
Tipo de documento: Artigo
Idioma: eng
Título da fonte: International Braz J Urol (Online)
Texto Completo: http://old.scielo.br/scielo.php?script=sci_arttext&pid=S1677-55382013000400572
Resumo: Purpose To evaluate infrared thermometer (IRT) accuracy compared to standard digital thermometer in measuring kidney temperature during arterial clamping with and without renal cooling. Materials and Methods 20 pigs weighting 20Kg underwent selective right renal arterial clamping, 10 with (Group 1 - Cold Ischemia with ice slush) and 10 without renal cooling (Group 2 - Warm Ischemia). Arterial clamping was performed without venous clamping. Renal temperature was serially measured following clamping of the main renal artery with the IRT and a digital contact thermometer (DT): immediate after clamping (T0), after 2 (T2), 5 (T5) and 10 minutes (T10). Temperature values were expressed in mean, standard deviation and range for each thermometer. We used the T student test to compare means and considered p < 0.05 to be statistically significant. Results In Group 1, mean DT surface temperature decrease was 12.6 ± 4.1°C (5-19°C) while deep DT temperature decrease was 15.8 ± 1.5°C (15-18°C). For the IRT, mean temperature decrease was 9.1 ± 3.8°C (3-14°C). There was no statistically significant difference between thermometers. In Group 2, surface temperature decrease for DT was 2.7 ± 1.8°C (0-4°C) and mean deep temperature decrease was 0.5 ± 1.0°C (0-3°C). For IRT, mean temperature decrease was 3.1 ± 1.9°C (0-6°C). No statistically significant difference between thermometers was found at any time point. conclusions IRT proved to be an accurate non-invasive precise device for renal temperature monitoring during kidney surgery. External ice slush cooling confirmed to be fast and effective at cooling the pig model. IRT = Infrared thermometer DT = Digital contact thermometer D:S = Distance-to-spot ratio
id SBU-1_a77a57e11e34ffb7a421f89676079b6e
oai_identifier_str oai:scielo:S1677-55382013000400572
network_acronym_str SBU-1
network_name_str International Braz J Urol (Online)
repository_id_str
spelling Infrared Thermometer: an accurate tool for temperature measurement during renal surgeryRenal Blood FlowEffectiveIschemiaInfrared RaysThermometers Purpose To evaluate infrared thermometer (IRT) accuracy compared to standard digital thermometer in measuring kidney temperature during arterial clamping with and without renal cooling. Materials and Methods 20 pigs weighting 20Kg underwent selective right renal arterial clamping, 10 with (Group 1 - Cold Ischemia with ice slush) and 10 without renal cooling (Group 2 - Warm Ischemia). Arterial clamping was performed without venous clamping. Renal temperature was serially measured following clamping of the main renal artery with the IRT and a digital contact thermometer (DT): immediate after clamping (T0), after 2 (T2), 5 (T5) and 10 minutes (T10). Temperature values were expressed in mean, standard deviation and range for each thermometer. We used the T student test to compare means and considered p < 0.05 to be statistically significant. Results In Group 1, mean DT surface temperature decrease was 12.6 ± 4.1°C (5-19°C) while deep DT temperature decrease was 15.8 ± 1.5°C (15-18°C). For the IRT, mean temperature decrease was 9.1 ± 3.8°C (3-14°C). There was no statistically significant difference between thermometers. In Group 2, surface temperature decrease for DT was 2.7 ± 1.8°C (0-4°C) and mean deep temperature decrease was 0.5 ± 1.0°C (0-3°C). For IRT, mean temperature decrease was 3.1 ± 1.9°C (0-6°C). No statistically significant difference between thermometers was found at any time point. conclusions IRT proved to be an accurate non-invasive precise device for renal temperature monitoring during kidney surgery. External ice slush cooling confirmed to be fast and effective at cooling the pig model. IRT = Infrared thermometer DT = Digital contact thermometer D:S = Distance-to-spot ratio Sociedade Brasileira de Urologia2013-08-01info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersiontext/htmlhttp://old.scielo.br/scielo.php?script=sci_arttext&pid=S1677-55382013000400572International braz j urol v.39 n.4 2013reponame:International Braz J Urol (Online)instname:Sociedade Brasileira de Urologia (SBU)instacron:SBU10.1590/S1677-5538.IBJU.2013.04.16info:eu-repo/semantics/openAccessMarchini,Giovanni ScalaDuarte,Ricardo JordaoMitre,Anuar IbrahimTiseo,Bruno CamargoCassao,Valter Dell'AcquaTorricelli,Fabio Cesar MirandaArap,Marco AntonioSrougi,Migueleng2013-10-10T00:00:00Zoai:scielo:S1677-55382013000400572Revistahttp://www.brazjurol.com.br/ONGhttps://old.scielo.br/oai/scielo-oai.php||brazjurol@brazjurol.com.br1677-61191677-5538opendoar:2013-10-10T00:00International Braz J Urol (Online) - Sociedade Brasileira de Urologia (SBU)false
dc.title.none.fl_str_mv Infrared Thermometer: an accurate tool for temperature measurement during renal surgery
title Infrared Thermometer: an accurate tool for temperature measurement during renal surgery
spellingShingle Infrared Thermometer: an accurate tool for temperature measurement during renal surgery
Marchini,Giovanni Scala
Renal Blood Flow
Effective
Ischemia
Infrared Rays
Thermometers
title_short Infrared Thermometer: an accurate tool for temperature measurement during renal surgery
title_full Infrared Thermometer: an accurate tool for temperature measurement during renal surgery
title_fullStr Infrared Thermometer: an accurate tool for temperature measurement during renal surgery
title_full_unstemmed Infrared Thermometer: an accurate tool for temperature measurement during renal surgery
title_sort Infrared Thermometer: an accurate tool for temperature measurement during renal surgery
author Marchini,Giovanni Scala
author_facet Marchini,Giovanni Scala
Duarte,Ricardo Jordao
Mitre,Anuar Ibrahim
Tiseo,Bruno Camargo
Cassao,Valter Dell'Acqua
Torricelli,Fabio Cesar Miranda
Arap,Marco Antonio
Srougi,Miguel
author_role author
author2 Duarte,Ricardo Jordao
Mitre,Anuar Ibrahim
Tiseo,Bruno Camargo
Cassao,Valter Dell'Acqua
Torricelli,Fabio Cesar Miranda
Arap,Marco Antonio
Srougi,Miguel
author2_role author
author
author
author
author
author
author
dc.contributor.author.fl_str_mv Marchini,Giovanni Scala
Duarte,Ricardo Jordao
Mitre,Anuar Ibrahim
Tiseo,Bruno Camargo
Cassao,Valter Dell'Acqua
Torricelli,Fabio Cesar Miranda
Arap,Marco Antonio
Srougi,Miguel
dc.subject.por.fl_str_mv Renal Blood Flow
Effective
Ischemia
Infrared Rays
Thermometers
topic Renal Blood Flow
Effective
Ischemia
Infrared Rays
Thermometers
description Purpose To evaluate infrared thermometer (IRT) accuracy compared to standard digital thermometer in measuring kidney temperature during arterial clamping with and without renal cooling. Materials and Methods 20 pigs weighting 20Kg underwent selective right renal arterial clamping, 10 with (Group 1 - Cold Ischemia with ice slush) and 10 without renal cooling (Group 2 - Warm Ischemia). Arterial clamping was performed without venous clamping. Renal temperature was serially measured following clamping of the main renal artery with the IRT and a digital contact thermometer (DT): immediate after clamping (T0), after 2 (T2), 5 (T5) and 10 minutes (T10). Temperature values were expressed in mean, standard deviation and range for each thermometer. We used the T student test to compare means and considered p < 0.05 to be statistically significant. Results In Group 1, mean DT surface temperature decrease was 12.6 ± 4.1°C (5-19°C) while deep DT temperature decrease was 15.8 ± 1.5°C (15-18°C). For the IRT, mean temperature decrease was 9.1 ± 3.8°C (3-14°C). There was no statistically significant difference between thermometers. In Group 2, surface temperature decrease for DT was 2.7 ± 1.8°C (0-4°C) and mean deep temperature decrease was 0.5 ± 1.0°C (0-3°C). For IRT, mean temperature decrease was 3.1 ± 1.9°C (0-6°C). No statistically significant difference between thermometers was found at any time point. conclusions IRT proved to be an accurate non-invasive precise device for renal temperature monitoring during kidney surgery. External ice slush cooling confirmed to be fast and effective at cooling the pig model. IRT = Infrared thermometer DT = Digital contact thermometer D:S = Distance-to-spot ratio
publishDate 2013
dc.date.none.fl_str_mv 2013-08-01
dc.type.driver.fl_str_mv info:eu-repo/semantics/article
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
format article
status_str publishedVersion
dc.identifier.uri.fl_str_mv http://old.scielo.br/scielo.php?script=sci_arttext&pid=S1677-55382013000400572
url http://old.scielo.br/scielo.php?script=sci_arttext&pid=S1677-55382013000400572
dc.language.iso.fl_str_mv eng
language eng
dc.relation.none.fl_str_mv 10.1590/S1677-5538.IBJU.2013.04.16
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv text/html
dc.publisher.none.fl_str_mv Sociedade Brasileira de Urologia
publisher.none.fl_str_mv Sociedade Brasileira de Urologia
dc.source.none.fl_str_mv International braz j urol v.39 n.4 2013
reponame:International Braz J Urol (Online)
instname:Sociedade Brasileira de Urologia (SBU)
instacron:SBU
instname_str Sociedade Brasileira de Urologia (SBU)
instacron_str SBU
institution SBU
reponame_str International Braz J Urol (Online)
collection International Braz J Urol (Online)
repository.name.fl_str_mv International Braz J Urol (Online) - Sociedade Brasileira de Urologia (SBU)
repository.mail.fl_str_mv ||brazjurol@brazjurol.com.br
_version_ 1750318073247694848