Diagnostic accuracy of contrast-enhanced ultrasound for detecting bland thrombus from inferior vena cava tumor thrombus in patients with renal cell carcinoma

Detalhes bibliográficos
Autor(a) principal: Li,Qiuyang
Data de Publicação: 2020
Outros Autores: Wang,Zhongxin, Ma,Xin, Tang,Jie, Luo,Yukun
Tipo de documento: Artigo
Idioma: eng
Título da fonte: International Braz J Urol (Online)
Texto Completo: http://old.scielo.br/scielo.php?script=sci_arttext&pid=S1677-55382020000100092
Resumo: ABSTRACT Purpose: To evaluate the role of contrast-enhanced ultrasound (CEUS) in differentiating bland thrombus from tumor thrombus of the inferior vena cava (IVC) in patients with renal cell carcinoma (RCC). Materials and Methods: We retrospectively investigated 30 consecutive patients who underwent robot-assisted radical nephrectomy with IVC thrombectomy and had pathologically confirmed RCC. All patients underwent US and CEUS examination. Two off-line readers observed and recorded thrombus imaging information and enhancement patterns. Sensitivity, specificity, accuracy, positive predictive value and negative predictive value for bland thrombus were assessed. Results: Of the 30 patients, no adverse events occurred during administration of the contrast agent. Early enhancement of the mass within the IVC lumen on CEUS was an indicator of tumor thrombus. Bland thrombus showed no intraluminal flow on CEUS. There were eight (26.7%) patients with bland thrombus, including three level II, two level III, and three level IV. There were three cases with cephalic bland thrombus and five cases with caudal bland thrombus. Three caudal bland thrombi extended to the iliac vein and underwent surgical IVC interruption. Based on no intraluminal flow, for bland thrombus, CEUS had 87.5% sensitivity, 100% specificity, 96.7% accuracy, 100% positive predictive value and 95.6% negative predictive value. Conclusion: Our study demonstrates the potential of CEUS in the differentiation of bland and tumor thrombus of the IVC in patients with RCC. Since CEUS is an effective, inexpensive, and non-invasive method, it could be a reliable tool in the evaluation of IVC thrombus in patients with RCC.
id SBU-1_ec4ba8867bc5de94e5be28920d0db3ef
oai_identifier_str oai:scielo:S1677-55382020000100092
network_acronym_str SBU-1
network_name_str International Braz J Urol (Online)
repository_id_str
spelling Diagnostic accuracy of contrast-enhanced ultrasound for detecting bland thrombus from inferior vena cava tumor thrombus in patients with renal cell carcinomaCarcinomaDiagnosisThrombosisABSTRACT Purpose: To evaluate the role of contrast-enhanced ultrasound (CEUS) in differentiating bland thrombus from tumor thrombus of the inferior vena cava (IVC) in patients with renal cell carcinoma (RCC). Materials and Methods: We retrospectively investigated 30 consecutive patients who underwent robot-assisted radical nephrectomy with IVC thrombectomy and had pathologically confirmed RCC. All patients underwent US and CEUS examination. Two off-line readers observed and recorded thrombus imaging information and enhancement patterns. Sensitivity, specificity, accuracy, positive predictive value and negative predictive value for bland thrombus were assessed. Results: Of the 30 patients, no adverse events occurred during administration of the contrast agent. Early enhancement of the mass within the IVC lumen on CEUS was an indicator of tumor thrombus. Bland thrombus showed no intraluminal flow on CEUS. There were eight (26.7%) patients with bland thrombus, including three level II, two level III, and three level IV. There were three cases with cephalic bland thrombus and five cases with caudal bland thrombus. Three caudal bland thrombi extended to the iliac vein and underwent surgical IVC interruption. Based on no intraluminal flow, for bland thrombus, CEUS had 87.5% sensitivity, 100% specificity, 96.7% accuracy, 100% positive predictive value and 95.6% negative predictive value. Conclusion: Our study demonstrates the potential of CEUS in the differentiation of bland and tumor thrombus of the IVC in patients with RCC. Since CEUS is an effective, inexpensive, and non-invasive method, it could be a reliable tool in the evaluation of IVC thrombus in patients with RCC.Sociedade Brasileira de Urologia2020-02-01info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersiontext/htmlhttp://old.scielo.br/scielo.php?script=sci_arttext&pid=S1677-55382020000100092International braz j urol v.46 n.1 2020reponame:International Braz J Urol (Online)instname:Sociedade Brasileira de Urologia (SBU)instacron:SBU10.1590/s1677-5538.ibju.2019.0304info:eu-repo/semantics/openAccessLi,QiuyangWang,ZhongxinMa,XinTang,JieLuo,Yukuneng2020-01-10T00:00:00Zoai:scielo:S1677-55382020000100092Revistahttp://www.brazjurol.com.br/ONGhttps://old.scielo.br/oai/scielo-oai.php||brazjurol@brazjurol.com.br1677-61191677-5538opendoar:2020-01-10T00:00International Braz J Urol (Online) - Sociedade Brasileira de Urologia (SBU)false
dc.title.none.fl_str_mv Diagnostic accuracy of contrast-enhanced ultrasound for detecting bland thrombus from inferior vena cava tumor thrombus in patients with renal cell carcinoma
title Diagnostic accuracy of contrast-enhanced ultrasound for detecting bland thrombus from inferior vena cava tumor thrombus in patients with renal cell carcinoma
spellingShingle Diagnostic accuracy of contrast-enhanced ultrasound for detecting bland thrombus from inferior vena cava tumor thrombus in patients with renal cell carcinoma
Li,Qiuyang
Carcinoma
Diagnosis
Thrombosis
title_short Diagnostic accuracy of contrast-enhanced ultrasound for detecting bland thrombus from inferior vena cava tumor thrombus in patients with renal cell carcinoma
title_full Diagnostic accuracy of contrast-enhanced ultrasound for detecting bland thrombus from inferior vena cava tumor thrombus in patients with renal cell carcinoma
title_fullStr Diagnostic accuracy of contrast-enhanced ultrasound for detecting bland thrombus from inferior vena cava tumor thrombus in patients with renal cell carcinoma
title_full_unstemmed Diagnostic accuracy of contrast-enhanced ultrasound for detecting bland thrombus from inferior vena cava tumor thrombus in patients with renal cell carcinoma
title_sort Diagnostic accuracy of contrast-enhanced ultrasound for detecting bland thrombus from inferior vena cava tumor thrombus in patients with renal cell carcinoma
author Li,Qiuyang
author_facet Li,Qiuyang
Wang,Zhongxin
Ma,Xin
Tang,Jie
Luo,Yukun
author_role author
author2 Wang,Zhongxin
Ma,Xin
Tang,Jie
Luo,Yukun
author2_role author
author
author
author
dc.contributor.author.fl_str_mv Li,Qiuyang
Wang,Zhongxin
Ma,Xin
Tang,Jie
Luo,Yukun
dc.subject.por.fl_str_mv Carcinoma
Diagnosis
Thrombosis
topic Carcinoma
Diagnosis
Thrombosis
description ABSTRACT Purpose: To evaluate the role of contrast-enhanced ultrasound (CEUS) in differentiating bland thrombus from tumor thrombus of the inferior vena cava (IVC) in patients with renal cell carcinoma (RCC). Materials and Methods: We retrospectively investigated 30 consecutive patients who underwent robot-assisted radical nephrectomy with IVC thrombectomy and had pathologically confirmed RCC. All patients underwent US and CEUS examination. Two off-line readers observed and recorded thrombus imaging information and enhancement patterns. Sensitivity, specificity, accuracy, positive predictive value and negative predictive value for bland thrombus were assessed. Results: Of the 30 patients, no adverse events occurred during administration of the contrast agent. Early enhancement of the mass within the IVC lumen on CEUS was an indicator of tumor thrombus. Bland thrombus showed no intraluminal flow on CEUS. There were eight (26.7%) patients with bland thrombus, including three level II, two level III, and three level IV. There were three cases with cephalic bland thrombus and five cases with caudal bland thrombus. Three caudal bland thrombi extended to the iliac vein and underwent surgical IVC interruption. Based on no intraluminal flow, for bland thrombus, CEUS had 87.5% sensitivity, 100% specificity, 96.7% accuracy, 100% positive predictive value and 95.6% negative predictive value. Conclusion: Our study demonstrates the potential of CEUS in the differentiation of bland and tumor thrombus of the IVC in patients with RCC. Since CEUS is an effective, inexpensive, and non-invasive method, it could be a reliable tool in the evaluation of IVC thrombus in patients with RCC.
publishDate 2020
dc.date.none.fl_str_mv 2020-02-01
dc.type.driver.fl_str_mv info:eu-repo/semantics/article
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
format article
status_str publishedVersion
dc.identifier.uri.fl_str_mv http://old.scielo.br/scielo.php?script=sci_arttext&pid=S1677-55382020000100092
url http://old.scielo.br/scielo.php?script=sci_arttext&pid=S1677-55382020000100092
dc.language.iso.fl_str_mv eng
language eng
dc.relation.none.fl_str_mv 10.1590/s1677-5538.ibju.2019.0304
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv text/html
dc.publisher.none.fl_str_mv Sociedade Brasileira de Urologia
publisher.none.fl_str_mv Sociedade Brasileira de Urologia
dc.source.none.fl_str_mv International braz j urol v.46 n.1 2020
reponame:International Braz J Urol (Online)
instname:Sociedade Brasileira de Urologia (SBU)
instacron:SBU
instname_str Sociedade Brasileira de Urologia (SBU)
instacron_str SBU
institution SBU
reponame_str International Braz J Urol (Online)
collection International Braz J Urol (Online)
repository.name.fl_str_mv International Braz J Urol (Online) - Sociedade Brasileira de Urologia (SBU)
repository.mail.fl_str_mv ||brazjurol@brazjurol.com.br
_version_ 1750318077258498048