Comportamento em fadiga da liga Ti-6Al-4V para uso biomédico com superfícies modificadas

Detalhes bibliográficos
Autor(a) principal: Potomati, Fernanda
Data de Publicação: 2011
Tipo de documento: Tese
Idioma: por
Título da fonte: Repositório Institucional da UFSCAR
Texto Completo: https://repositorio.ufscar.br/handle/ufscar/15116
Resumo: Surface modification in implants is used, basically, to improve osseointegration, which is defined as the intimate contact between bone and implant material, without a soft tissue layer in the bone/implant interface. Titanium alloys, which are the most commonly used materials in the fabrication of hip stem, have an excellent biocompatibility. The surface modification of these materials can lead to a better osseointegration. The developments and studies of new modification processes are very dynamic and often related to biological aspects, for example, cellular growth on the modified surface. Studies regarding engineering and properties of the implant with modified surface are not up to date with the quickness of new processes developments and evaluation of these processes on cellular response. Since fatigue is a determinant property of implants, this study aims to evaluate the fatigue behavior of Ti-6Al-4V alloy with modified surfaces by laser and anodic oxidation. Thus, axial fatigue tests were performed to obtain SxN curves (Stress x number of cycles) of cylindrical specimens, in the polished and surface treated conditions. Roughness measurements and scanning electron microscopic (SEM) were used to characterize the features of the modified surface. As a result, the modification by anodic oxidation, for the parameters used, did not affect the fatigue behavior of Ti-6Al-4V alloy. Unlike anodic oxidation, the laser surface modification performed in this work decreases by about 30% the limit of fatigue strength of the alloy.
id SCAR_028d5629ec81eef49735e876fde724fa
oai_identifier_str oai:repositorio.ufscar.br:ufscar/15116
network_acronym_str SCAR
network_name_str Repositório Institucional da UFSCAR
repository_id_str 4322
spelling Potomati, FernandaBolfarini, Claudemirohttp://lattes.cnpq.br/9231627080617037Alcântara, Nelson Guedes dehttp://lattes.cnpq.br/3123107570992184http://lattes.cnpq.br/1449729356742076064ab3f9-184a-487b-ba23-c828abcb2f072021-11-16T20:08:06Z2021-11-16T20:08:06Z2011-09-09POTOMATI, Fernanda. Comportamento em fadiga da liga Ti-6Al-4V para uso biomédico com superfícies modificadas. 2011. Tese (Doutorado em Ciência e Engenharia de Materiais) – Universidade Federal de São Carlos, São Carlos, 2011. Disponível em: https://repositorio.ufscar.br/handle/ufscar/15116.https://repositorio.ufscar.br/handle/ufscar/15116Surface modification in implants is used, basically, to improve osseointegration, which is defined as the intimate contact between bone and implant material, without a soft tissue layer in the bone/implant interface. Titanium alloys, which are the most commonly used materials in the fabrication of hip stem, have an excellent biocompatibility. The surface modification of these materials can lead to a better osseointegration. The developments and studies of new modification processes are very dynamic and often related to biological aspects, for example, cellular growth on the modified surface. Studies regarding engineering and properties of the implant with modified surface are not up to date with the quickness of new processes developments and evaluation of these processes on cellular response. Since fatigue is a determinant property of implants, this study aims to evaluate the fatigue behavior of Ti-6Al-4V alloy with modified surfaces by laser and anodic oxidation. Thus, axial fatigue tests were performed to obtain SxN curves (Stress x number of cycles) of cylindrical specimens, in the polished and surface treated conditions. Roughness measurements and scanning electron microscopic (SEM) were used to characterize the features of the modified surface. As a result, the modification by anodic oxidation, for the parameters used, did not affect the fatigue behavior of Ti-6Al-4V alloy. Unlike anodic oxidation, the laser surface modification performed in this work decreases by about 30% the limit of fatigue strength of the alloy.Implantes com superfície modificada são usados, basicamente, para melhor promover a osseointegração, que consiste no contato direto osso/implante sem a intervenção de um tecido fibroso. As ligas de titânio, que são os materiais mais utilizados na fabricação de hastes femorais, apresentam excelente biocompatibilidade. A modificação de superfície desses materiais melhora ainda mais a osseointegração. O desenvolvimento e o estudo de novos processos de modificação de superfície são bastante dinâmicos e geralmente concentram-se em estudos biológicos, como, por exemplo, o crescimento celular sobre a superfície modificada. Os estudos de engenharia e propriedades dos implantes com superfície modificada não acompanham a rapidez com que os processos de modificação são desenvolvidos e avaliados quanto à resposta biológica. Sendo a fadiga propriedade determinante na utilização de um implante, esse trabalho tem como objetivo estudar o comportamento em fadiga da liga Ti-6Al-4V submetida a processos ainda em estudo; modificação por laser e oxidação anódica. Para tanto, foram realizados ensaios de fadiga para obtenção de curvas Tensão x Número de ciclos (curvas SxN), de corpos de prova polidos e com superfície modificada. Técnicas de microscopia eletrônica de varredura e de medidas de rugosidade foram utilizadas para caracterização das superfícies. Como resultado, a modificação por anodização, para os parâmetros utilizados, não alterou o comportamento em fadiga da liga Ti-6Al-4V. Ao contrário da oxidação anódica, a modificação da superfície por laser realizada neste trabalho diminuiu em cerca de 30% o limite de resistência à fadiga da liga.Não recebi financiamentoporUniversidade Federal de São CarlosCâmpus São CarlosPrograma de Pós-Graduação em Ciência e Engenharia de Materiais - PPGCEMUFSCarAttribution-NonCommercial-NoDerivs 3.0 Brazilhttp://creativecommons.org/licenses/by-nc-nd/3.0/br/info:eu-repo/semantics/openAccessTitânioFadigaModificação de superfícieRugosidadeTitaniumFatigueSurface modificationRoughnessENGENHARIAS::ENGENHARIA DE MATERIAIS E METALURGICAComportamento em fadiga da liga Ti-6Al-4V para uso biomédico com superfícies modificadasFatigue behavior of surface-modified Ti-6Al-4V alloy for medical applicationsinfo:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/doctoralThesis600600ea2697dd-8d22-4c7a-8bdd-487c739e04c7reponame:Repositório Institucional da UFSCARinstname:Universidade Federal de São Carlos (UFSCAR)instacron:UFSCARORIGINALFernanda_Potomati___Tese.pdfFernanda_Potomati___Tese.pdfTese finalapplication/pdf5972160https://repositorio.ufscar.br/bitstream/ufscar/15116/1/Fernanda_Potomati___Tese.pdfd62d805cc340f71fa8dab73caf43dedbMD51BCO_carta_comprovante_autoarquivamento_P.pdfBCO_carta_comprovante_autoarquivamento_P.pdfCarta Comprovanteapplication/pdf366550https://repositorio.ufscar.br/bitstream/ufscar/15116/3/BCO_carta_comprovante_autoarquivamento_P.pdf5810d1a0a2cdad55397912e39a68fadbMD53CC-LICENSElicense_rdflicense_rdfapplication/rdf+xml; charset=utf-8811https://repositorio.ufscar.br/bitstream/ufscar/15116/2/license_rdfe39d27027a6cc9cb039ad269a5db8e34MD52TEXTFernanda_Potomati___Tese.pdf.txtFernanda_Potomati___Tese.pdf.txtExtracted texttext/plain180523https://repositorio.ufscar.br/bitstream/ufscar/15116/4/Fernanda_Potomati___Tese.pdf.txt0f14b2bad55e40f7917ce01670774e9fMD54BCO_carta_comprovante_autoarquivamento_P.pdf.txtBCO_carta_comprovante_autoarquivamento_P.pdf.txtExtracted texttext/plain1https://repositorio.ufscar.br/bitstream/ufscar/15116/6/BCO_carta_comprovante_autoarquivamento_P.pdf.txt68b329da9893e34099c7d8ad5cb9c940MD56THUMBNAILFernanda_Potomati___Tese.pdf.jpgFernanda_Potomati___Tese.pdf.jpgIM Thumbnailimage/jpeg6333https://repositorio.ufscar.br/bitstream/ufscar/15116/5/Fernanda_Potomati___Tese.pdf.jpgc41f246cf8e0504c571b8019dd06e609MD55BCO_carta_comprovante_autoarquivamento_P.pdf.jpgBCO_carta_comprovante_autoarquivamento_P.pdf.jpgIM Thumbnailimage/jpeg13789https://repositorio.ufscar.br/bitstream/ufscar/15116/7/BCO_carta_comprovante_autoarquivamento_P.pdf.jpgedb28433a556b7a1076ff20f4deddf6fMD57ufscar/151162023-09-18 18:32:20.364oai:repositorio.ufscar.br:ufscar/15116Repositório InstitucionalPUBhttps://repositorio.ufscar.br/oai/requestopendoar:43222023-09-18T18:32:20Repositório Institucional da UFSCAR - Universidade Federal de São Carlos (UFSCAR)false
dc.title.por.fl_str_mv Comportamento em fadiga da liga Ti-6Al-4V para uso biomédico com superfícies modificadas
dc.title.alternative.eng.fl_str_mv Fatigue behavior of surface-modified Ti-6Al-4V alloy for medical applications
title Comportamento em fadiga da liga Ti-6Al-4V para uso biomédico com superfícies modificadas
spellingShingle Comportamento em fadiga da liga Ti-6Al-4V para uso biomédico com superfícies modificadas
Potomati, Fernanda
Titânio
Fadiga
Modificação de superfície
Rugosidade
Titanium
Fatigue
Surface modification
Roughness
ENGENHARIAS::ENGENHARIA DE MATERIAIS E METALURGICA
title_short Comportamento em fadiga da liga Ti-6Al-4V para uso biomédico com superfícies modificadas
title_full Comportamento em fadiga da liga Ti-6Al-4V para uso biomédico com superfícies modificadas
title_fullStr Comportamento em fadiga da liga Ti-6Al-4V para uso biomédico com superfícies modificadas
title_full_unstemmed Comportamento em fadiga da liga Ti-6Al-4V para uso biomédico com superfícies modificadas
title_sort Comportamento em fadiga da liga Ti-6Al-4V para uso biomédico com superfícies modificadas
author Potomati, Fernanda
author_facet Potomati, Fernanda
author_role author
dc.contributor.authorlattes.por.fl_str_mv http://lattes.cnpq.br/1449729356742076
dc.contributor.author.fl_str_mv Potomati, Fernanda
dc.contributor.advisor1.fl_str_mv Bolfarini, Claudemiro
dc.contributor.advisor1Lattes.fl_str_mv http://lattes.cnpq.br/9231627080617037
dc.contributor.advisor-co1.fl_str_mv Alcântara, Nelson Guedes de
dc.contributor.advisor-co1Lattes.fl_str_mv http://lattes.cnpq.br/3123107570992184
dc.contributor.authorID.fl_str_mv 064ab3f9-184a-487b-ba23-c828abcb2f07
contributor_str_mv Bolfarini, Claudemiro
Alcântara, Nelson Guedes de
dc.subject.por.fl_str_mv Titânio
Fadiga
Modificação de superfície
Rugosidade
topic Titânio
Fadiga
Modificação de superfície
Rugosidade
Titanium
Fatigue
Surface modification
Roughness
ENGENHARIAS::ENGENHARIA DE MATERIAIS E METALURGICA
dc.subject.eng.fl_str_mv Titanium
Fatigue
Surface modification
Roughness
dc.subject.cnpq.fl_str_mv ENGENHARIAS::ENGENHARIA DE MATERIAIS E METALURGICA
description Surface modification in implants is used, basically, to improve osseointegration, which is defined as the intimate contact between bone and implant material, without a soft tissue layer in the bone/implant interface. Titanium alloys, which are the most commonly used materials in the fabrication of hip stem, have an excellent biocompatibility. The surface modification of these materials can lead to a better osseointegration. The developments and studies of new modification processes are very dynamic and often related to biological aspects, for example, cellular growth on the modified surface. Studies regarding engineering and properties of the implant with modified surface are not up to date with the quickness of new processes developments and evaluation of these processes on cellular response. Since fatigue is a determinant property of implants, this study aims to evaluate the fatigue behavior of Ti-6Al-4V alloy with modified surfaces by laser and anodic oxidation. Thus, axial fatigue tests were performed to obtain SxN curves (Stress x number of cycles) of cylindrical specimens, in the polished and surface treated conditions. Roughness measurements and scanning electron microscopic (SEM) were used to characterize the features of the modified surface. As a result, the modification by anodic oxidation, for the parameters used, did not affect the fatigue behavior of Ti-6Al-4V alloy. Unlike anodic oxidation, the laser surface modification performed in this work decreases by about 30% the limit of fatigue strength of the alloy.
publishDate 2011
dc.date.issued.fl_str_mv 2011-09-09
dc.date.accessioned.fl_str_mv 2021-11-16T20:08:06Z
dc.date.available.fl_str_mv 2021-11-16T20:08:06Z
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
dc.type.driver.fl_str_mv info:eu-repo/semantics/doctoralThesis
format doctoralThesis
status_str publishedVersion
dc.identifier.citation.fl_str_mv POTOMATI, Fernanda. Comportamento em fadiga da liga Ti-6Al-4V para uso biomédico com superfícies modificadas. 2011. Tese (Doutorado em Ciência e Engenharia de Materiais) – Universidade Federal de São Carlos, São Carlos, 2011. Disponível em: https://repositorio.ufscar.br/handle/ufscar/15116.
dc.identifier.uri.fl_str_mv https://repositorio.ufscar.br/handle/ufscar/15116
identifier_str_mv POTOMATI, Fernanda. Comportamento em fadiga da liga Ti-6Al-4V para uso biomédico com superfícies modificadas. 2011. Tese (Doutorado em Ciência e Engenharia de Materiais) – Universidade Federal de São Carlos, São Carlos, 2011. Disponível em: https://repositorio.ufscar.br/handle/ufscar/15116.
url https://repositorio.ufscar.br/handle/ufscar/15116
dc.language.iso.fl_str_mv por
language por
dc.relation.confidence.fl_str_mv 600
600
dc.relation.authority.fl_str_mv ea2697dd-8d22-4c7a-8bdd-487c739e04c7
dc.rights.driver.fl_str_mv Attribution-NonCommercial-NoDerivs 3.0 Brazil
http://creativecommons.org/licenses/by-nc-nd/3.0/br/
info:eu-repo/semantics/openAccess
rights_invalid_str_mv Attribution-NonCommercial-NoDerivs 3.0 Brazil
http://creativecommons.org/licenses/by-nc-nd/3.0/br/
eu_rights_str_mv openAccess
dc.publisher.none.fl_str_mv Universidade Federal de São Carlos
Câmpus São Carlos
dc.publisher.program.fl_str_mv Programa de Pós-Graduação em Ciência e Engenharia de Materiais - PPGCEM
dc.publisher.initials.fl_str_mv UFSCar
publisher.none.fl_str_mv Universidade Federal de São Carlos
Câmpus São Carlos
dc.source.none.fl_str_mv reponame:Repositório Institucional da UFSCAR
instname:Universidade Federal de São Carlos (UFSCAR)
instacron:UFSCAR
instname_str Universidade Federal de São Carlos (UFSCAR)
instacron_str UFSCAR
institution UFSCAR
reponame_str Repositório Institucional da UFSCAR
collection Repositório Institucional da UFSCAR
bitstream.url.fl_str_mv https://repositorio.ufscar.br/bitstream/ufscar/15116/1/Fernanda_Potomati___Tese.pdf
https://repositorio.ufscar.br/bitstream/ufscar/15116/3/BCO_carta_comprovante_autoarquivamento_P.pdf
https://repositorio.ufscar.br/bitstream/ufscar/15116/2/license_rdf
https://repositorio.ufscar.br/bitstream/ufscar/15116/4/Fernanda_Potomati___Tese.pdf.txt
https://repositorio.ufscar.br/bitstream/ufscar/15116/6/BCO_carta_comprovante_autoarquivamento_P.pdf.txt
https://repositorio.ufscar.br/bitstream/ufscar/15116/5/Fernanda_Potomati___Tese.pdf.jpg
https://repositorio.ufscar.br/bitstream/ufscar/15116/7/BCO_carta_comprovante_autoarquivamento_P.pdf.jpg
bitstream.checksum.fl_str_mv d62d805cc340f71fa8dab73caf43dedb
5810d1a0a2cdad55397912e39a68fadb
e39d27027a6cc9cb039ad269a5db8e34
0f14b2bad55e40f7917ce01670774e9f
68b329da9893e34099c7d8ad5cb9c940
c41f246cf8e0504c571b8019dd06e609
edb28433a556b7a1076ff20f4deddf6f
bitstream.checksumAlgorithm.fl_str_mv MD5
MD5
MD5
MD5
MD5
MD5
MD5
repository.name.fl_str_mv Repositório Institucional da UFSCAR - Universidade Federal de São Carlos (UFSCAR)
repository.mail.fl_str_mv
_version_ 1802136397900939264