Comportamento em fadiga da liga Ti-6Al-4V para uso biomédico com superfícies modificadas
Autor(a) principal: | |
---|---|
Data de Publicação: | 2011 |
Tipo de documento: | Tese |
Idioma: | por |
Título da fonte: | Repositório Institucional da UFSCAR |
Texto Completo: | https://repositorio.ufscar.br/handle/ufscar/15116 |
Resumo: | Surface modification in implants is used, basically, to improve osseointegration, which is defined as the intimate contact between bone and implant material, without a soft tissue layer in the bone/implant interface. Titanium alloys, which are the most commonly used materials in the fabrication of hip stem, have an excellent biocompatibility. The surface modification of these materials can lead to a better osseointegration. The developments and studies of new modification processes are very dynamic and often related to biological aspects, for example, cellular growth on the modified surface. Studies regarding engineering and properties of the implant with modified surface are not up to date with the quickness of new processes developments and evaluation of these processes on cellular response. Since fatigue is a determinant property of implants, this study aims to evaluate the fatigue behavior of Ti-6Al-4V alloy with modified surfaces by laser and anodic oxidation. Thus, axial fatigue tests were performed to obtain SxN curves (Stress x number of cycles) of cylindrical specimens, in the polished and surface treated conditions. Roughness measurements and scanning electron microscopic (SEM) were used to characterize the features of the modified surface. As a result, the modification by anodic oxidation, for the parameters used, did not affect the fatigue behavior of Ti-6Al-4V alloy. Unlike anodic oxidation, the laser surface modification performed in this work decreases by about 30% the limit of fatigue strength of the alloy. |
id |
SCAR_028d5629ec81eef49735e876fde724fa |
---|---|
oai_identifier_str |
oai:repositorio.ufscar.br:ufscar/15116 |
network_acronym_str |
SCAR |
network_name_str |
Repositório Institucional da UFSCAR |
repository_id_str |
4322 |
spelling |
Potomati, FernandaBolfarini, Claudemirohttp://lattes.cnpq.br/9231627080617037Alcântara, Nelson Guedes dehttp://lattes.cnpq.br/3123107570992184http://lattes.cnpq.br/1449729356742076064ab3f9-184a-487b-ba23-c828abcb2f072021-11-16T20:08:06Z2021-11-16T20:08:06Z2011-09-09POTOMATI, Fernanda. Comportamento em fadiga da liga Ti-6Al-4V para uso biomédico com superfícies modificadas. 2011. Tese (Doutorado em Ciência e Engenharia de Materiais) – Universidade Federal de São Carlos, São Carlos, 2011. Disponível em: https://repositorio.ufscar.br/handle/ufscar/15116.https://repositorio.ufscar.br/handle/ufscar/15116Surface modification in implants is used, basically, to improve osseointegration, which is defined as the intimate contact between bone and implant material, without a soft tissue layer in the bone/implant interface. Titanium alloys, which are the most commonly used materials in the fabrication of hip stem, have an excellent biocompatibility. The surface modification of these materials can lead to a better osseointegration. The developments and studies of new modification processes are very dynamic and often related to biological aspects, for example, cellular growth on the modified surface. Studies regarding engineering and properties of the implant with modified surface are not up to date with the quickness of new processes developments and evaluation of these processes on cellular response. Since fatigue is a determinant property of implants, this study aims to evaluate the fatigue behavior of Ti-6Al-4V alloy with modified surfaces by laser and anodic oxidation. Thus, axial fatigue tests were performed to obtain SxN curves (Stress x number of cycles) of cylindrical specimens, in the polished and surface treated conditions. Roughness measurements and scanning electron microscopic (SEM) were used to characterize the features of the modified surface. As a result, the modification by anodic oxidation, for the parameters used, did not affect the fatigue behavior of Ti-6Al-4V alloy. Unlike anodic oxidation, the laser surface modification performed in this work decreases by about 30% the limit of fatigue strength of the alloy.Implantes com superfície modificada são usados, basicamente, para melhor promover a osseointegração, que consiste no contato direto osso/implante sem a intervenção de um tecido fibroso. As ligas de titânio, que são os materiais mais utilizados na fabricação de hastes femorais, apresentam excelente biocompatibilidade. A modificação de superfície desses materiais melhora ainda mais a osseointegração. O desenvolvimento e o estudo de novos processos de modificação de superfície são bastante dinâmicos e geralmente concentram-se em estudos biológicos, como, por exemplo, o crescimento celular sobre a superfície modificada. Os estudos de engenharia e propriedades dos implantes com superfície modificada não acompanham a rapidez com que os processos de modificação são desenvolvidos e avaliados quanto à resposta biológica. Sendo a fadiga propriedade determinante na utilização de um implante, esse trabalho tem como objetivo estudar o comportamento em fadiga da liga Ti-6Al-4V submetida a processos ainda em estudo; modificação por laser e oxidação anódica. Para tanto, foram realizados ensaios de fadiga para obtenção de curvas Tensão x Número de ciclos (curvas SxN), de corpos de prova polidos e com superfície modificada. Técnicas de microscopia eletrônica de varredura e de medidas de rugosidade foram utilizadas para caracterização das superfícies. Como resultado, a modificação por anodização, para os parâmetros utilizados, não alterou o comportamento em fadiga da liga Ti-6Al-4V. Ao contrário da oxidação anódica, a modificação da superfície por laser realizada neste trabalho diminuiu em cerca de 30% o limite de resistência à fadiga da liga.Não recebi financiamentoporUniversidade Federal de São CarlosCâmpus São CarlosPrograma de Pós-Graduação em Ciência e Engenharia de Materiais - PPGCEMUFSCarAttribution-NonCommercial-NoDerivs 3.0 Brazilhttp://creativecommons.org/licenses/by-nc-nd/3.0/br/info:eu-repo/semantics/openAccessTitânioFadigaModificação de superfícieRugosidadeTitaniumFatigueSurface modificationRoughnessENGENHARIAS::ENGENHARIA DE MATERIAIS E METALURGICAComportamento em fadiga da liga Ti-6Al-4V para uso biomédico com superfícies modificadasFatigue behavior of surface-modified Ti-6Al-4V alloy for medical applicationsinfo:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/doctoralThesis600600ea2697dd-8d22-4c7a-8bdd-487c739e04c7reponame:Repositório Institucional da UFSCARinstname:Universidade Federal de São Carlos (UFSCAR)instacron:UFSCARORIGINALFernanda_Potomati___Tese.pdfFernanda_Potomati___Tese.pdfTese finalapplication/pdf5972160https://repositorio.ufscar.br/bitstream/ufscar/15116/1/Fernanda_Potomati___Tese.pdfd62d805cc340f71fa8dab73caf43dedbMD51BCO_carta_comprovante_autoarquivamento_P.pdfBCO_carta_comprovante_autoarquivamento_P.pdfCarta Comprovanteapplication/pdf366550https://repositorio.ufscar.br/bitstream/ufscar/15116/3/BCO_carta_comprovante_autoarquivamento_P.pdf5810d1a0a2cdad55397912e39a68fadbMD53CC-LICENSElicense_rdflicense_rdfapplication/rdf+xml; charset=utf-8811https://repositorio.ufscar.br/bitstream/ufscar/15116/2/license_rdfe39d27027a6cc9cb039ad269a5db8e34MD52TEXTFernanda_Potomati___Tese.pdf.txtFernanda_Potomati___Tese.pdf.txtExtracted texttext/plain180523https://repositorio.ufscar.br/bitstream/ufscar/15116/4/Fernanda_Potomati___Tese.pdf.txt0f14b2bad55e40f7917ce01670774e9fMD54BCO_carta_comprovante_autoarquivamento_P.pdf.txtBCO_carta_comprovante_autoarquivamento_P.pdf.txtExtracted texttext/plain1https://repositorio.ufscar.br/bitstream/ufscar/15116/6/BCO_carta_comprovante_autoarquivamento_P.pdf.txt68b329da9893e34099c7d8ad5cb9c940MD56THUMBNAILFernanda_Potomati___Tese.pdf.jpgFernanda_Potomati___Tese.pdf.jpgIM Thumbnailimage/jpeg6333https://repositorio.ufscar.br/bitstream/ufscar/15116/5/Fernanda_Potomati___Tese.pdf.jpgc41f246cf8e0504c571b8019dd06e609MD55BCO_carta_comprovante_autoarquivamento_P.pdf.jpgBCO_carta_comprovante_autoarquivamento_P.pdf.jpgIM Thumbnailimage/jpeg13789https://repositorio.ufscar.br/bitstream/ufscar/15116/7/BCO_carta_comprovante_autoarquivamento_P.pdf.jpgedb28433a556b7a1076ff20f4deddf6fMD57ufscar/151162023-09-18 18:32:20.364oai:repositorio.ufscar.br:ufscar/15116Repositório InstitucionalPUBhttps://repositorio.ufscar.br/oai/requestopendoar:43222023-09-18T18:32:20Repositório Institucional da UFSCAR - Universidade Federal de São Carlos (UFSCAR)false |
dc.title.por.fl_str_mv |
Comportamento em fadiga da liga Ti-6Al-4V para uso biomédico com superfícies modificadas |
dc.title.alternative.eng.fl_str_mv |
Fatigue behavior of surface-modified Ti-6Al-4V alloy for medical applications |
title |
Comportamento em fadiga da liga Ti-6Al-4V para uso biomédico com superfícies modificadas |
spellingShingle |
Comportamento em fadiga da liga Ti-6Al-4V para uso biomédico com superfícies modificadas Potomati, Fernanda Titânio Fadiga Modificação de superfície Rugosidade Titanium Fatigue Surface modification Roughness ENGENHARIAS::ENGENHARIA DE MATERIAIS E METALURGICA |
title_short |
Comportamento em fadiga da liga Ti-6Al-4V para uso biomédico com superfícies modificadas |
title_full |
Comportamento em fadiga da liga Ti-6Al-4V para uso biomédico com superfícies modificadas |
title_fullStr |
Comportamento em fadiga da liga Ti-6Al-4V para uso biomédico com superfícies modificadas |
title_full_unstemmed |
Comportamento em fadiga da liga Ti-6Al-4V para uso biomédico com superfícies modificadas |
title_sort |
Comportamento em fadiga da liga Ti-6Al-4V para uso biomédico com superfícies modificadas |
author |
Potomati, Fernanda |
author_facet |
Potomati, Fernanda |
author_role |
author |
dc.contributor.authorlattes.por.fl_str_mv |
http://lattes.cnpq.br/1449729356742076 |
dc.contributor.author.fl_str_mv |
Potomati, Fernanda |
dc.contributor.advisor1.fl_str_mv |
Bolfarini, Claudemiro |
dc.contributor.advisor1Lattes.fl_str_mv |
http://lattes.cnpq.br/9231627080617037 |
dc.contributor.advisor-co1.fl_str_mv |
Alcântara, Nelson Guedes de |
dc.contributor.advisor-co1Lattes.fl_str_mv |
http://lattes.cnpq.br/3123107570992184 |
dc.contributor.authorID.fl_str_mv |
064ab3f9-184a-487b-ba23-c828abcb2f07 |
contributor_str_mv |
Bolfarini, Claudemiro Alcântara, Nelson Guedes de |
dc.subject.por.fl_str_mv |
Titânio Fadiga Modificação de superfície Rugosidade |
topic |
Titânio Fadiga Modificação de superfície Rugosidade Titanium Fatigue Surface modification Roughness ENGENHARIAS::ENGENHARIA DE MATERIAIS E METALURGICA |
dc.subject.eng.fl_str_mv |
Titanium Fatigue Surface modification Roughness |
dc.subject.cnpq.fl_str_mv |
ENGENHARIAS::ENGENHARIA DE MATERIAIS E METALURGICA |
description |
Surface modification in implants is used, basically, to improve osseointegration, which is defined as the intimate contact between bone and implant material, without a soft tissue layer in the bone/implant interface. Titanium alloys, which are the most commonly used materials in the fabrication of hip stem, have an excellent biocompatibility. The surface modification of these materials can lead to a better osseointegration. The developments and studies of new modification processes are very dynamic and often related to biological aspects, for example, cellular growth on the modified surface. Studies regarding engineering and properties of the implant with modified surface are not up to date with the quickness of new processes developments and evaluation of these processes on cellular response. Since fatigue is a determinant property of implants, this study aims to evaluate the fatigue behavior of Ti-6Al-4V alloy with modified surfaces by laser and anodic oxidation. Thus, axial fatigue tests were performed to obtain SxN curves (Stress x number of cycles) of cylindrical specimens, in the polished and surface treated conditions. Roughness measurements and scanning electron microscopic (SEM) were used to characterize the features of the modified surface. As a result, the modification by anodic oxidation, for the parameters used, did not affect the fatigue behavior of Ti-6Al-4V alloy. Unlike anodic oxidation, the laser surface modification performed in this work decreases by about 30% the limit of fatigue strength of the alloy. |
publishDate |
2011 |
dc.date.issued.fl_str_mv |
2011-09-09 |
dc.date.accessioned.fl_str_mv |
2021-11-16T20:08:06Z |
dc.date.available.fl_str_mv |
2021-11-16T20:08:06Z |
dc.type.status.fl_str_mv |
info:eu-repo/semantics/publishedVersion |
dc.type.driver.fl_str_mv |
info:eu-repo/semantics/doctoralThesis |
format |
doctoralThesis |
status_str |
publishedVersion |
dc.identifier.citation.fl_str_mv |
POTOMATI, Fernanda. Comportamento em fadiga da liga Ti-6Al-4V para uso biomédico com superfícies modificadas. 2011. Tese (Doutorado em Ciência e Engenharia de Materiais) – Universidade Federal de São Carlos, São Carlos, 2011. Disponível em: https://repositorio.ufscar.br/handle/ufscar/15116. |
dc.identifier.uri.fl_str_mv |
https://repositorio.ufscar.br/handle/ufscar/15116 |
identifier_str_mv |
POTOMATI, Fernanda. Comportamento em fadiga da liga Ti-6Al-4V para uso biomédico com superfícies modificadas. 2011. Tese (Doutorado em Ciência e Engenharia de Materiais) – Universidade Federal de São Carlos, São Carlos, 2011. Disponível em: https://repositorio.ufscar.br/handle/ufscar/15116. |
url |
https://repositorio.ufscar.br/handle/ufscar/15116 |
dc.language.iso.fl_str_mv |
por |
language |
por |
dc.relation.confidence.fl_str_mv |
600 600 |
dc.relation.authority.fl_str_mv |
ea2697dd-8d22-4c7a-8bdd-487c739e04c7 |
dc.rights.driver.fl_str_mv |
Attribution-NonCommercial-NoDerivs 3.0 Brazil http://creativecommons.org/licenses/by-nc-nd/3.0/br/ info:eu-repo/semantics/openAccess |
rights_invalid_str_mv |
Attribution-NonCommercial-NoDerivs 3.0 Brazil http://creativecommons.org/licenses/by-nc-nd/3.0/br/ |
eu_rights_str_mv |
openAccess |
dc.publisher.none.fl_str_mv |
Universidade Federal de São Carlos Câmpus São Carlos |
dc.publisher.program.fl_str_mv |
Programa de Pós-Graduação em Ciência e Engenharia de Materiais - PPGCEM |
dc.publisher.initials.fl_str_mv |
UFSCar |
publisher.none.fl_str_mv |
Universidade Federal de São Carlos Câmpus São Carlos |
dc.source.none.fl_str_mv |
reponame:Repositório Institucional da UFSCAR instname:Universidade Federal de São Carlos (UFSCAR) instacron:UFSCAR |
instname_str |
Universidade Federal de São Carlos (UFSCAR) |
instacron_str |
UFSCAR |
institution |
UFSCAR |
reponame_str |
Repositório Institucional da UFSCAR |
collection |
Repositório Institucional da UFSCAR |
bitstream.url.fl_str_mv |
https://repositorio.ufscar.br/bitstream/ufscar/15116/1/Fernanda_Potomati___Tese.pdf https://repositorio.ufscar.br/bitstream/ufscar/15116/3/BCO_carta_comprovante_autoarquivamento_P.pdf https://repositorio.ufscar.br/bitstream/ufscar/15116/2/license_rdf https://repositorio.ufscar.br/bitstream/ufscar/15116/4/Fernanda_Potomati___Tese.pdf.txt https://repositorio.ufscar.br/bitstream/ufscar/15116/6/BCO_carta_comprovante_autoarquivamento_P.pdf.txt https://repositorio.ufscar.br/bitstream/ufscar/15116/5/Fernanda_Potomati___Tese.pdf.jpg https://repositorio.ufscar.br/bitstream/ufscar/15116/7/BCO_carta_comprovante_autoarquivamento_P.pdf.jpg |
bitstream.checksum.fl_str_mv |
d62d805cc340f71fa8dab73caf43dedb 5810d1a0a2cdad55397912e39a68fadb e39d27027a6cc9cb039ad269a5db8e34 0f14b2bad55e40f7917ce01670774e9f 68b329da9893e34099c7d8ad5cb9c940 c41f246cf8e0504c571b8019dd06e609 edb28433a556b7a1076ff20f4deddf6f |
bitstream.checksumAlgorithm.fl_str_mv |
MD5 MD5 MD5 MD5 MD5 MD5 MD5 |
repository.name.fl_str_mv |
Repositório Institucional da UFSCAR - Universidade Federal de São Carlos (UFSCAR) |
repository.mail.fl_str_mv |
|
_version_ |
1813715638823157760 |