Incidência microbiana e medidas preventivas de contaminação em superfícies de um centro cirúrgico

Detalhes bibliográficos
Autor(a) principal: Bardaquim, Vanessa Augusto
Data de Publicação: 2012
Tipo de documento: Dissertação
Idioma: por
Título da fonte: Repositório Institucional da UFSCAR
Texto Completo: https://repositorio.ufscar.br/handle/ufscar/3241
Resumo: The composition and concentration of microorganisms are extremely important components to demonstrate the level of hygiene in hospital operating rooms. The information from these strategies can be developed to maintain a biologically safe hospital environment by eliminating the focus of contact and transmission, and thus preventing nosocomial infections that cause a considerable increase in length of hospitalization, morbidity and mortality and thus helping to increase hospital costs, delays the recovery of patients and higher public spending. Another factor is the association of bully resistant microorganisms in hospital infections. Given the importance of the theme of contamination NI Microbial resistance and because there are few studies in Brazil where it may be noted the degree of microbial contamination on surfaces (table medication, surgical table, marble countertops and air conditioning grilles) of an operating room of a medium-sized hospital, the present study was conducted to quantify and identify bacteria and fungi these surfaces and assess the resistance profile to some antimicrobials of bacterial isolates. Samples were collected with the aid of a swab soaked in sterile peptone water and rubbed into quadrants of 20 cm2 surface under study. Hafnia alvei was detected (2,9%), Pseudomonas spp. (4,3%), Shigella spp. (4,3%), Staphylococcus aureus (5,7%), Staphylococcus coagulase-negative (5,71%), Staphylococcus spp. (50,0%) e Bacillus spp (12,9%). All strains of S. aureus showed sensitivity and resistance to Penicillin G, Amoxicillin and Oxacilina. Given this information from contamination of the surfaces studied, presents measures to minimize these contaminants in order to provide or improve the welfare of the occupants of such environments with the implementation of practices and standards based upon current legislation, minimizing the problems that may occur with the health of both employees and users of outpatient services and hospital.
id SCAR_0f5f8bd569d4323d626e603fdeb4e5bc
oai_identifier_str oai:repositorio.ufscar.br:ufscar/3241
network_acronym_str SCAR
network_name_str Repositório Institucional da UFSCAR
repository_id_str 4322
spelling Bardaquim, Vanessa AugustoSousa, Cristina Paiva dehttp://lattes.cnpq.br/9002619114161319http://lattes.cnpq.br/372681994126930629171ff5-41ca-4aff-bef4-9650d654a19c2016-06-02T19:48:20Z2012-04-192016-06-02T19:48:20Z2012-02-29BARDAQUIM, Vanessa Augusto. Incidência microbiana e medidas preventivas de contaminação em superfícies de um centro cirúrgico. 2012. 71 f. Dissertação (Mestrado em Ciências da Saúde) - Universidade Federal de São Carlos, São Carlos, 2012.https://repositorio.ufscar.br/handle/ufscar/3241The composition and concentration of microorganisms are extremely important components to demonstrate the level of hygiene in hospital operating rooms. The information from these strategies can be developed to maintain a biologically safe hospital environment by eliminating the focus of contact and transmission, and thus preventing nosocomial infections that cause a considerable increase in length of hospitalization, morbidity and mortality and thus helping to increase hospital costs, delays the recovery of patients and higher public spending. Another factor is the association of bully resistant microorganisms in hospital infections. Given the importance of the theme of contamination NI Microbial resistance and because there are few studies in Brazil where it may be noted the degree of microbial contamination on surfaces (table medication, surgical table, marble countertops and air conditioning grilles) of an operating room of a medium-sized hospital, the present study was conducted to quantify and identify bacteria and fungi these surfaces and assess the resistance profile to some antimicrobials of bacterial isolates. Samples were collected with the aid of a swab soaked in sterile peptone water and rubbed into quadrants of 20 cm2 surface under study. Hafnia alvei was detected (2,9%), Pseudomonas spp. (4,3%), Shigella spp. (4,3%), Staphylococcus aureus (5,7%), Staphylococcus coagulase-negative (5,71%), Staphylococcus spp. (50,0%) e Bacillus spp (12,9%). All strains of S. aureus showed sensitivity and resistance to Penicillin G, Amoxicillin and Oxacilina. Given this information from contamination of the surfaces studied, presents measures to minimize these contaminants in order to provide or improve the welfare of the occupants of such environments with the implementation of practices and standards based upon current legislation, minimizing the problems that may occur with the health of both employees and users of outpatient services and hospital.RESUMO A determinação da composição e concentração de micro-organismos são componentes extremamente importantes para demonstrar o grau de higiene em centros cirúrgicos hospitalares. A partir destas informações podem ser desenvolvidas estratégias para a manutenção de um ambiente hospitalar biologicamente seguro por eliminação dos focos de contato e transmissão e, assim, prevenir as infecções nosocomiais que acarretam um aumento considerável no período de hospitalização, da morbimortalidade e, consequentemente, colaborando na elevação dos custos hospitalares, atrasos na recuperação de pacientes e maiores gastos públicos. Outro fator implicante é a associação de micro-organismos resistentes com as infecções hospitalares. Diante da relevância do tema contaminação - infecção hospitalar - resistência microbiana e pelo fato de existirem poucos estudos no Brasil onde possa ser ressaltado o grau de contaminação microbiana em superfícies de um centro cirúrgico de um hospital de médio porte, o presente estudo foi realizado objetivando-se quantificar e identificar bactérias e fungos destas superfícies e avaliar o perfil de resistência à antimicrobianos de algumas bactérias isoladas. Todas as amostras foram coletadas com o auxílio de um swab esterilizado embebido em água peptonada e friccionado em quadrantes de 20 cm2 das superfícies pesquisadas: mesa de medicação, mesa cirúrgica, bancada de mármore e grades de ar condicionado. Detectou-se Hafnia alvei (2,9%), Pseudomonas spp. (4,3%), Shigella spp. (4,3%), Staphylococcus aureus (5,7%), Staphylococcus coagulase-negativo (5,71%), Staphylococcus spp. (50,0%) e Bacillus spp (12,9%). Todas as cepas de S. aureus apresentaram sensibilidade à Novabiocina e resistência à Penicilina G, Oxacilina e Amoxicilina. Diante dessas informações da contaminação das superfícies pesquisadas, apresentam-se medidas que minimizem estas contaminações a fim de propiciar ou melhorar o bem-estar dos ocupantes de tais ambientes com a implantação de práticas e normas fundamentadas nas legislações vigentes, minimizando os problemas que possam ocorrer com a saúde tanto de funcionários quanto de usuários de serviços ambulatoriais ou hospitalares.Financiadora de Estudos e Projetosapplication/pdfporUniversidade Federal de São CarlosPrograma de Pós-Graduação em Enfermagem - PPGEnfUFSCarBREnfermagemMicrobiologiaInfecção hospitalarCentro CirúrgicoContaminação de superfíciesHospital InfectionContamination of SurfacesMicrobiologySurgical CenterCIENCIAS DA SAUDE::ENFERMAGEMIncidência microbiana e medidas preventivas de contaminação em superfícies de um centro cirúrgicoinfo:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/masterThesis-1-135b91dbf-6130-418b-915b-3380dadd62dcinfo:eu-repo/semantics/openAccessreponame:Repositório Institucional da UFSCARinstname:Universidade Federal de São Carlos (UFSCAR)instacron:UFSCARORIGINAL4247.pdfapplication/pdf997310https://repositorio.ufscar.br/bitstream/ufscar/3241/1/4247.pdfc1a1e10fcb8b79df4437d5a2bc6bdca0MD51TEXT4247.pdf.txt4247.pdf.txtExtracted texttext/plain0https://repositorio.ufscar.br/bitstream/ufscar/3241/2/4247.pdf.txtd41d8cd98f00b204e9800998ecf8427eMD52THUMBNAIL4247.pdf.jpg4247.pdf.jpgIM Thumbnailimage/jpeg5923https://repositorio.ufscar.br/bitstream/ufscar/3241/3/4247.pdf.jpg7d0f27aadc30aced1a8d5f2aef7ea47fMD53ufscar/32412023-09-18 18:31:44.196oai:repositorio.ufscar.br:ufscar/3241Repositório InstitucionalPUBhttps://repositorio.ufscar.br/oai/requestopendoar:43222023-09-18T18:31:44Repositório Institucional da UFSCAR - Universidade Federal de São Carlos (UFSCAR)false
dc.title.por.fl_str_mv Incidência microbiana e medidas preventivas de contaminação em superfícies de um centro cirúrgico
title Incidência microbiana e medidas preventivas de contaminação em superfícies de um centro cirúrgico
spellingShingle Incidência microbiana e medidas preventivas de contaminação em superfícies de um centro cirúrgico
Bardaquim, Vanessa Augusto
Enfermagem
Microbiologia
Infecção hospitalar
Centro Cirúrgico
Contaminação de superfícies
Hospital Infection
Contamination of Surfaces
Microbiology
Surgical Center
CIENCIAS DA SAUDE::ENFERMAGEM
title_short Incidência microbiana e medidas preventivas de contaminação em superfícies de um centro cirúrgico
title_full Incidência microbiana e medidas preventivas de contaminação em superfícies de um centro cirúrgico
title_fullStr Incidência microbiana e medidas preventivas de contaminação em superfícies de um centro cirúrgico
title_full_unstemmed Incidência microbiana e medidas preventivas de contaminação em superfícies de um centro cirúrgico
title_sort Incidência microbiana e medidas preventivas de contaminação em superfícies de um centro cirúrgico
author Bardaquim, Vanessa Augusto
author_facet Bardaquim, Vanessa Augusto
author_role author
dc.contributor.authorlattes.por.fl_str_mv http://lattes.cnpq.br/3726819941269306
dc.contributor.author.fl_str_mv Bardaquim, Vanessa Augusto
dc.contributor.advisor1.fl_str_mv Sousa, Cristina Paiva de
dc.contributor.advisor1Lattes.fl_str_mv http://lattes.cnpq.br/9002619114161319
dc.contributor.authorID.fl_str_mv 29171ff5-41ca-4aff-bef4-9650d654a19c
contributor_str_mv Sousa, Cristina Paiva de
dc.subject.por.fl_str_mv Enfermagem
Microbiologia
Infecção hospitalar
Centro Cirúrgico
Contaminação de superfícies
topic Enfermagem
Microbiologia
Infecção hospitalar
Centro Cirúrgico
Contaminação de superfícies
Hospital Infection
Contamination of Surfaces
Microbiology
Surgical Center
CIENCIAS DA SAUDE::ENFERMAGEM
dc.subject.eng.fl_str_mv Hospital Infection
Contamination of Surfaces
Microbiology
Surgical Center
dc.subject.cnpq.fl_str_mv CIENCIAS DA SAUDE::ENFERMAGEM
description The composition and concentration of microorganisms are extremely important components to demonstrate the level of hygiene in hospital operating rooms. The information from these strategies can be developed to maintain a biologically safe hospital environment by eliminating the focus of contact and transmission, and thus preventing nosocomial infections that cause a considerable increase in length of hospitalization, morbidity and mortality and thus helping to increase hospital costs, delays the recovery of patients and higher public spending. Another factor is the association of bully resistant microorganisms in hospital infections. Given the importance of the theme of contamination NI Microbial resistance and because there are few studies in Brazil where it may be noted the degree of microbial contamination on surfaces (table medication, surgical table, marble countertops and air conditioning grilles) of an operating room of a medium-sized hospital, the present study was conducted to quantify and identify bacteria and fungi these surfaces and assess the resistance profile to some antimicrobials of bacterial isolates. Samples were collected with the aid of a swab soaked in sterile peptone water and rubbed into quadrants of 20 cm2 surface under study. Hafnia alvei was detected (2,9%), Pseudomonas spp. (4,3%), Shigella spp. (4,3%), Staphylococcus aureus (5,7%), Staphylococcus coagulase-negative (5,71%), Staphylococcus spp. (50,0%) e Bacillus spp (12,9%). All strains of S. aureus showed sensitivity and resistance to Penicillin G, Amoxicillin and Oxacilina. Given this information from contamination of the surfaces studied, presents measures to minimize these contaminants in order to provide or improve the welfare of the occupants of such environments with the implementation of practices and standards based upon current legislation, minimizing the problems that may occur with the health of both employees and users of outpatient services and hospital.
publishDate 2012
dc.date.available.fl_str_mv 2012-04-19
2016-06-02T19:48:20Z
dc.date.issued.fl_str_mv 2012-02-29
dc.date.accessioned.fl_str_mv 2016-06-02T19:48:20Z
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
dc.type.driver.fl_str_mv info:eu-repo/semantics/masterThesis
format masterThesis
status_str publishedVersion
dc.identifier.citation.fl_str_mv BARDAQUIM, Vanessa Augusto. Incidência microbiana e medidas preventivas de contaminação em superfícies de um centro cirúrgico. 2012. 71 f. Dissertação (Mestrado em Ciências da Saúde) - Universidade Federal de São Carlos, São Carlos, 2012.
dc.identifier.uri.fl_str_mv https://repositorio.ufscar.br/handle/ufscar/3241
identifier_str_mv BARDAQUIM, Vanessa Augusto. Incidência microbiana e medidas preventivas de contaminação em superfícies de um centro cirúrgico. 2012. 71 f. Dissertação (Mestrado em Ciências da Saúde) - Universidade Federal de São Carlos, São Carlos, 2012.
url https://repositorio.ufscar.br/handle/ufscar/3241
dc.language.iso.fl_str_mv por
language por
dc.relation.confidence.fl_str_mv -1
-1
dc.relation.authority.fl_str_mv 35b91dbf-6130-418b-915b-3380dadd62dc
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv application/pdf
dc.publisher.none.fl_str_mv Universidade Federal de São Carlos
dc.publisher.program.fl_str_mv Programa de Pós-Graduação em Enfermagem - PPGEnf
dc.publisher.initials.fl_str_mv UFSCar
dc.publisher.country.fl_str_mv BR
publisher.none.fl_str_mv Universidade Federal de São Carlos
dc.source.none.fl_str_mv reponame:Repositório Institucional da UFSCAR
instname:Universidade Federal de São Carlos (UFSCAR)
instacron:UFSCAR
instname_str Universidade Federal de São Carlos (UFSCAR)
instacron_str UFSCAR
institution UFSCAR
reponame_str Repositório Institucional da UFSCAR
collection Repositório Institucional da UFSCAR
bitstream.url.fl_str_mv https://repositorio.ufscar.br/bitstream/ufscar/3241/1/4247.pdf
https://repositorio.ufscar.br/bitstream/ufscar/3241/2/4247.pdf.txt
https://repositorio.ufscar.br/bitstream/ufscar/3241/3/4247.pdf.jpg
bitstream.checksum.fl_str_mv c1a1e10fcb8b79df4437d5a2bc6bdca0
d41d8cd98f00b204e9800998ecf8427e
7d0f27aadc30aced1a8d5f2aef7ea47f
bitstream.checksumAlgorithm.fl_str_mv MD5
MD5
MD5
repository.name.fl_str_mv Repositório Institucional da UFSCAR - Universidade Federal de São Carlos (UFSCAR)
repository.mail.fl_str_mv
_version_ 1813715525948145664