Chaminé solar como alternativa para incrementar a ventilação natural em espaços internos
Autor(a) principal: | |
---|---|
Data de Publicação: | 2010 |
Tipo de documento: | Dissertação |
Idioma: | por |
Título da fonte: | Repositório Institucional da UFSCAR |
Texto Completo: | https://repositorio.ufscar.br/handle/ufscar/4650 |
Resumo: | This work aims to investigate the influence of solar chimneys in the natural ventilation in buildings located in Brazil. Considering that Brazil is a tropical country and has a great potential for the harnessing of solar radiation, it is intended to verify the hypothesis that the use of this device may increase air movement in indoor spaces contributing to promote thermal comfort for users of these environments. The methodology used to verify this hypothesis was based on comparing the performance of two construction systems: a conventional chimney and a solar chimney. The two models have the same height and dimensions for the air inlet and outlet. This comparison was performed by computer simulations using EnergyPlus software, for eight Brazilian cities located in each one of the bioclimatic zones of Brazil, during winter and summer. The investigated device showed satisfactory performance, increasing natural ventilation during the day in all cities simulated, even in winter, when natural ventilation may not be desired in some climates. The data were presented to facilitate the understanding of professionals in the Construction Industry in general, contributing to establish a theoretical framework on the subject, and projective guidelines for more efficient buildings from the standpoint of energy. It is also intended to contribute to the potential of this device is investigated in several Brazilian regions, always trying to adapt the buildings to the climate of where it will be built. |
id |
SCAR_126383691fbdc1b8343c01190f142b31 |
---|---|
oai_identifier_str |
oai:repositorio.ufscar.br:ufscar/4650 |
network_acronym_str |
SCAR |
network_name_str |
Repositório Institucional da UFSCAR |
repository_id_str |
4322 |
spelling |
Cavalcanti, Fernando Antonio de Melo SáRoriz, Mauríciohttp://lattes.cnpq.br/6355579765506588http://lattes.cnpq.br/440765766895093167d49f92-5f1f-40b8-b7f9-88654466e9182016-06-02T20:09:12Z2010-08-062016-06-02T20:09:12Z2010-08-02https://repositorio.ufscar.br/handle/ufscar/4650This work aims to investigate the influence of solar chimneys in the natural ventilation in buildings located in Brazil. Considering that Brazil is a tropical country and has a great potential for the harnessing of solar radiation, it is intended to verify the hypothesis that the use of this device may increase air movement in indoor spaces contributing to promote thermal comfort for users of these environments. The methodology used to verify this hypothesis was based on comparing the performance of two construction systems: a conventional chimney and a solar chimney. The two models have the same height and dimensions for the air inlet and outlet. This comparison was performed by computer simulations using EnergyPlus software, for eight Brazilian cities located in each one of the bioclimatic zones of Brazil, during winter and summer. The investigated device showed satisfactory performance, increasing natural ventilation during the day in all cities simulated, even in winter, when natural ventilation may not be desired in some climates. The data were presented to facilitate the understanding of professionals in the Construction Industry in general, contributing to establish a theoretical framework on the subject, and projective guidelines for more efficient buildings from the standpoint of energy. It is also intended to contribute to the potential of this device is investigated in several Brazilian regions, always trying to adapt the buildings to the climate of where it will be built.Este trabalho tem como finalidade investigar a influência que o uso de chaminés solares possuem na ventilação natural em edifícios localizados no Brasil. Tendo em vista que o Brasil é um pais tropical e possui um grande potencial para aproveitamento da Radiação Solar, pretende-se verificar a hipótese de que a utilização deste dispositivo pode incrementar a ação dos ventos em espaços internos de modo a contribuir na promoção do conforto para os usuários destes ambientes. A metodologia utilizada para verificar esta hipótese foi baseada na comparação entre o desempenho de dois sistemas construtivos: um dotado de chaminé convencional e outro com chaminé solar, sendo os dois modelos com a mesma altura e dimensões para aberturas de entrada e saída do ar. Esta comparação foi realizada a partir de simulações computacionais utilizando o software EnergyPlus, para 8 cidades brasileiras, representativas de cada uma das zonas bioclimáticas do pais, nos períodos de inverno e verão. O dispositivo investigado apresentou desempenho satisfatório, aumentando a ventilação natural no período diurno em todas as cidades simuladas, inclusive no período de inverno, quando a ventilação natural pode não ser desejável em alguns climas. Os dados foram apresentados de forma a facilitar o entendimento dos profissionais da Construção Civil em geral, visando contribuir para estabelecer um referencial teórico sobre o assunto, alem de diretrizes projetuais para edifícios mais eficientes do ponto de vista energético. Pretende-se também contribuir para que o potencial deste dispositivo seja investigado nas mais diversas regiões brasileiras, buscando adaptar sempre as edificações ao clima do sitio onde serão construídas.Financiadora de Estudos e ProjetosporUniversidade Federal de São CarlosPrograma de Pós-Graduação em Engenharia Civil - PPGECivUFSCarBRConstrução civilConforto ambientalEconomia de energiaVentilação naturalChaminé solarEnergyPlusNatural ventilationSolar ChimneyEnergyPlusENGENHARIAS::ENGENHARIA CIVIL::CONSTRUCAO CIVILChaminé solar como alternativa para incrementar a ventilação natural em espaços internosSolar Chimney as alternative to increase the natural ventilation in indoor spacesinfo:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/masterThesis-1-11660d3b4-0b55-403a-a8a8-01247a770470info:eu-repo/semantics/openAccessreponame:Repositório Institucional da UFSCARinstname:Universidade Federal de São Carlos (UFSCAR)instacron:UFSCARORIGINAL3134.pdf3134.pdfapplication/pdf3840591https://repositorio.ufscar.br/bitstream/ufscar/4650/1/3134.pdf4b8e9a1d16018d4b6da6b715a8383f99MD51THUMBNAIL3134.pdf.jpg3134.pdf.jpgIM Thumbnailimage/jpeg14056https://repositorio.ufscar.br/bitstream/ufscar/4650/2/3134.pdf.jpg0bcd1bb0620d0ed255c7e197bea0fc27MD52ufscar/46502023-09-18 18:31:03.653oai:repositorio.ufscar.br:ufscar/4650Repositório InstitucionalPUBhttps://repositorio.ufscar.br/oai/requestopendoar:43222023-09-18T18:31:03Repositório Institucional da UFSCAR - Universidade Federal de São Carlos (UFSCAR)false |
dc.title.por.fl_str_mv |
Chaminé solar como alternativa para incrementar a ventilação natural em espaços internos |
dc.title.alternative.eng.fl_str_mv |
Solar Chimney as alternative to increase the natural ventilation in indoor spaces |
title |
Chaminé solar como alternativa para incrementar a ventilação natural em espaços internos |
spellingShingle |
Chaminé solar como alternativa para incrementar a ventilação natural em espaços internos Cavalcanti, Fernando Antonio de Melo Sá Construção civil Conforto ambiental Economia de energia Ventilação natural Chaminé solar EnergyPlus Natural ventilation Solar Chimney EnergyPlus ENGENHARIAS::ENGENHARIA CIVIL::CONSTRUCAO CIVIL |
title_short |
Chaminé solar como alternativa para incrementar a ventilação natural em espaços internos |
title_full |
Chaminé solar como alternativa para incrementar a ventilação natural em espaços internos |
title_fullStr |
Chaminé solar como alternativa para incrementar a ventilação natural em espaços internos |
title_full_unstemmed |
Chaminé solar como alternativa para incrementar a ventilação natural em espaços internos |
title_sort |
Chaminé solar como alternativa para incrementar a ventilação natural em espaços internos |
author |
Cavalcanti, Fernando Antonio de Melo Sá |
author_facet |
Cavalcanti, Fernando Antonio de Melo Sá |
author_role |
author |
dc.contributor.authorlattes.por.fl_str_mv |
http://lattes.cnpq.br/4407657668950931 |
dc.contributor.author.fl_str_mv |
Cavalcanti, Fernando Antonio de Melo Sá |
dc.contributor.advisor1.fl_str_mv |
Roriz, Maurício |
dc.contributor.advisor1Lattes.fl_str_mv |
http://lattes.cnpq.br/6355579765506588 |
dc.contributor.authorID.fl_str_mv |
67d49f92-5f1f-40b8-b7f9-88654466e918 |
contributor_str_mv |
Roriz, Maurício |
dc.subject.por.fl_str_mv |
Construção civil Conforto ambiental Economia de energia Ventilação natural Chaminé solar EnergyPlus |
topic |
Construção civil Conforto ambiental Economia de energia Ventilação natural Chaminé solar EnergyPlus Natural ventilation Solar Chimney EnergyPlus ENGENHARIAS::ENGENHARIA CIVIL::CONSTRUCAO CIVIL |
dc.subject.eng.fl_str_mv |
Natural ventilation Solar Chimney EnergyPlus |
dc.subject.cnpq.fl_str_mv |
ENGENHARIAS::ENGENHARIA CIVIL::CONSTRUCAO CIVIL |
description |
This work aims to investigate the influence of solar chimneys in the natural ventilation in buildings located in Brazil. Considering that Brazil is a tropical country and has a great potential for the harnessing of solar radiation, it is intended to verify the hypothesis that the use of this device may increase air movement in indoor spaces contributing to promote thermal comfort for users of these environments. The methodology used to verify this hypothesis was based on comparing the performance of two construction systems: a conventional chimney and a solar chimney. The two models have the same height and dimensions for the air inlet and outlet. This comparison was performed by computer simulations using EnergyPlus software, for eight Brazilian cities located in each one of the bioclimatic zones of Brazil, during winter and summer. The investigated device showed satisfactory performance, increasing natural ventilation during the day in all cities simulated, even in winter, when natural ventilation may not be desired in some climates. The data were presented to facilitate the understanding of professionals in the Construction Industry in general, contributing to establish a theoretical framework on the subject, and projective guidelines for more efficient buildings from the standpoint of energy. It is also intended to contribute to the potential of this device is investigated in several Brazilian regions, always trying to adapt the buildings to the climate of where it will be built. |
publishDate |
2010 |
dc.date.available.fl_str_mv |
2010-08-06 2016-06-02T20:09:12Z |
dc.date.issued.fl_str_mv |
2010-08-02 |
dc.date.accessioned.fl_str_mv |
2016-06-02T20:09:12Z |
dc.type.status.fl_str_mv |
info:eu-repo/semantics/publishedVersion |
dc.type.driver.fl_str_mv |
info:eu-repo/semantics/masterThesis |
format |
masterThesis |
status_str |
publishedVersion |
dc.identifier.uri.fl_str_mv |
https://repositorio.ufscar.br/handle/ufscar/4650 |
url |
https://repositorio.ufscar.br/handle/ufscar/4650 |
dc.language.iso.fl_str_mv |
por |
language |
por |
dc.relation.confidence.fl_str_mv |
-1 -1 |
dc.relation.authority.fl_str_mv |
1660d3b4-0b55-403a-a8a8-01247a770470 |
dc.rights.driver.fl_str_mv |
info:eu-repo/semantics/openAccess |
eu_rights_str_mv |
openAccess |
dc.publisher.none.fl_str_mv |
Universidade Federal de São Carlos |
dc.publisher.program.fl_str_mv |
Programa de Pós-Graduação em Engenharia Civil - PPGECiv |
dc.publisher.initials.fl_str_mv |
UFSCar |
dc.publisher.country.fl_str_mv |
BR |
publisher.none.fl_str_mv |
Universidade Federal de São Carlos |
dc.source.none.fl_str_mv |
reponame:Repositório Institucional da UFSCAR instname:Universidade Federal de São Carlos (UFSCAR) instacron:UFSCAR |
instname_str |
Universidade Federal de São Carlos (UFSCAR) |
instacron_str |
UFSCAR |
institution |
UFSCAR |
reponame_str |
Repositório Institucional da UFSCAR |
collection |
Repositório Institucional da UFSCAR |
bitstream.url.fl_str_mv |
https://repositorio.ufscar.br/bitstream/ufscar/4650/1/3134.pdf https://repositorio.ufscar.br/bitstream/ufscar/4650/2/3134.pdf.jpg |
bitstream.checksum.fl_str_mv |
4b8e9a1d16018d4b6da6b715a8383f99 0bcd1bb0620d0ed255c7e197bea0fc27 |
bitstream.checksumAlgorithm.fl_str_mv |
MD5 MD5 |
repository.name.fl_str_mv |
Repositório Institucional da UFSCAR - Universidade Federal de São Carlos (UFSCAR) |
repository.mail.fl_str_mv |
|
_version_ |
1813715537544347648 |