Fontes de erro em medidas eletrogoniométricas de movimentos do joelho

Detalhes bibliográficos
Autor(a) principal: Sato, Tatiana de Oliveira
Data de Publicação: 2008
Tipo de documento: Tese
Idioma: por
Título da fonte: Repositório Institucional da UFSCAR
Texto Completo: https://repositorio.ufscar.br/handle/ufscar/5097
Resumo: Flexible goniometers are useful for direct movement measurements. However issues related to subject-sensor interface can introduce measurement errors. Crosstalk, i.e. the phenomenon that flexion/extension angles affect the varus/valgus angles, and vice versa, is considered as the main drawback of goniometers. It is not well known the effect of the variation between identical sensors and the crosstalk due to endblocks misalignment in frontal and transverse planes. Thus, the objective of this study was to evaluate the effect of these sources of variation to goniometer recordings. A precision jig, for simulating pure flexion/extension angles, was constructed. Goniometer sensors were attached to this jig. In the initial study six biaxial goniometers were evaluated. Each sensor showed a consistent and specific crosstalk pattern. A procedure for correction for the inherent crosstalk, based on polynomial adjust, was proposed and evaluated. This procedure provided a major reduction of the inherent crosstalk. A second study was developed to evaluate the effect of endblocks misalignments. Results showed that varus/valgus misalignments did not cause additional errors for the recordings. Rotation between endblocks was the main source of error. Compensation procedures developed in the first study were applied in this second one, also resulting in crosstalk reduction. These compensations might be required in functional movement recordings to elucidate the crosstalk effect in knee measurements and the impact of the compensation procedures in measures, such as peaks, ranges of motion and movements curves.
id SCAR_2524703a5c4b04e5e7cc18757dcdebaf
oai_identifier_str oai:repositorio.ufscar.br:ufscar/5097
network_acronym_str SCAR
network_name_str Repositório Institucional da UFSCAR
repository_id_str 4322
spelling Sato, Tatiana de OliveiraCoury, Helenice Jane Cote Gilhttp://genos.cnpq.br:12010/dwlattes/owa/prc_imp_cv_int?f_cod=K4781843Y6http://buscatextual.cnpq.br/buscatextual/visualizacv.do?id=K4762813E9dcf669d1-e61c-43e2-9f4b-ca358eb5dd8b2016-06-02T20:18:09Z2008-07-112016-06-02T20:18:09Z2008-06-17SATO, Tatiana de Oliveira. Fontes de erro em medidas eletrogoniométricas de movimentos do joelho. 2008. 118 f. Tese (Doutorado em Ciências Biológicas) - Universidade Federal de São Carlos, São Carlos, 2008.https://repositorio.ufscar.br/handle/ufscar/5097Flexible goniometers are useful for direct movement measurements. However issues related to subject-sensor interface can introduce measurement errors. Crosstalk, i.e. the phenomenon that flexion/extension angles affect the varus/valgus angles, and vice versa, is considered as the main drawback of goniometers. It is not well known the effect of the variation between identical sensors and the crosstalk due to endblocks misalignment in frontal and transverse planes. Thus, the objective of this study was to evaluate the effect of these sources of variation to goniometer recordings. A precision jig, for simulating pure flexion/extension angles, was constructed. Goniometer sensors were attached to this jig. In the initial study six biaxial goniometers were evaluated. Each sensor showed a consistent and specific crosstalk pattern. A procedure for correction for the inherent crosstalk, based on polynomial adjust, was proposed and evaluated. This procedure provided a major reduction of the inherent crosstalk. A second study was developed to evaluate the effect of endblocks misalignments. Results showed that varus/valgus misalignments did not cause additional errors for the recordings. Rotation between endblocks was the main source of error. Compensation procedures developed in the first study were applied in this second one, also resulting in crosstalk reduction. These compensations might be required in functional movement recordings to elucidate the crosstalk effect in knee measurements and the impact of the compensation procedures in measures, such as peaks, ranges of motion and movements curves.A eletrogoniometria flexível é uma ferramenta de medida direta útil para avaliar os movimentos articulares. No entanto, ela requer alguns cuidados específicos, principalmente em relação à interface sensor-indivíduo. O crosstalk, ou seja, o fato de que movimentos realizados exclusivamente em um plano podem ser capturados como um falso registro no plano ortogonal, é considerado a principal fonte de erro do eletrogoniômetro. Não se sabe ainda qual a contribuição de variações entre sensores idênticos e do crosstalk devido ao desalinhamento dos terminais nos planos frontal e transverso. Portanto, este estudo tem por objetivo avaliar a contribuição destas fontes de erro para os registros eletrogoniométricos. Para isto foi desenvolvido um protótipo de precisão que simula movimentos puros de flexão/extensão. Os sensores do eletrogoniômetro foram acoplados neste protótipo. No estudo inicial foram avaliados seis sensores biaxiais. Cada sensor apresentou um padrão consistente e específico de crosstalk. Um procedimento de correção, baseado em ajuste polinomial, foi proposto e avaliado. Este procedimento causou uma redução expressiva dos erros devido ao crosstalk inerente. A partir deste estudo inicial foi realizado o segundo estudo. Os resultados deste segundo estudo indicaram que o desalinhamento em varo/valgo não causou erros adicionais nos registros e a rotação do sensor foi a principal fonte de crosstalk. Parte dos procedimentos de compensação dos erros desenvolvidos no Estudo 1 foram aplicados aos dados do Estudo 2, os quais também reduziram o crosstalk dos sensores. Estas compensações poderiam ser testadas em registros de movimentos funcionais para elucidar o efeito do crosstalk nas medidas cinemáticas do joelho e o impacto dos procedimentos de correção em medidas como picos, amplitudes e curvas de movimento.Financiadora de Estudos e Projetosapplication/pdfporUniversidade Federal de São CarlosPrograma de Pós-Graduação em Fisioterapia - PPGFtUFSCarBRMovimentoArticulação do joelhoEletrogoniometroConfiabilidade e ValidadeCIENCIAS DA SAUDE::FISIOTERAPIA E TERAPIA OCUPACIONALFontes de erro em medidas eletrogoniométricas de movimentos do joelhoinfo:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/doctoralThesis-1-19bbfa3f0-30d7-4fdb-b1a6-45490d6b3aa2info:eu-repo/semantics/openAccessreponame:Repositório Institucional da UFSCARinstname:Universidade Federal de São Carlos (UFSCAR)instacron:UFSCARORIGINAL1863.pdfapplication/pdf5855131https://repositorio.ufscar.br/bitstream/ufscar/5097/1/1863.pdf34b9c585b1ad7b0d544335d19ed3db45MD51THUMBNAIL1863.pdf.jpg1863.pdf.jpgIM Thumbnailimage/jpeg5771https://repositorio.ufscar.br/bitstream/ufscar/5097/2/1863.pdf.jpg2c9b52174359b904890e102b99a2917fMD52ufscar/50972023-09-18 18:31:05.569oai:repositorio.ufscar.br:ufscar/5097Repositório InstitucionalPUBhttps://repositorio.ufscar.br/oai/requestopendoar:43222023-09-18T18:31:05Repositório Institucional da UFSCAR - Universidade Federal de São Carlos (UFSCAR)false
dc.title.por.fl_str_mv Fontes de erro em medidas eletrogoniométricas de movimentos do joelho
title Fontes de erro em medidas eletrogoniométricas de movimentos do joelho
spellingShingle Fontes de erro em medidas eletrogoniométricas de movimentos do joelho
Sato, Tatiana de Oliveira
Movimento
Articulação do joelho
Eletrogoniometro
Confiabilidade e Validade
CIENCIAS DA SAUDE::FISIOTERAPIA E TERAPIA OCUPACIONAL
title_short Fontes de erro em medidas eletrogoniométricas de movimentos do joelho
title_full Fontes de erro em medidas eletrogoniométricas de movimentos do joelho
title_fullStr Fontes de erro em medidas eletrogoniométricas de movimentos do joelho
title_full_unstemmed Fontes de erro em medidas eletrogoniométricas de movimentos do joelho
title_sort Fontes de erro em medidas eletrogoniométricas de movimentos do joelho
author Sato, Tatiana de Oliveira
author_facet Sato, Tatiana de Oliveira
author_role author
dc.contributor.authorlattes.por.fl_str_mv http://buscatextual.cnpq.br/buscatextual/visualizacv.do?id=K4762813E9
dc.contributor.author.fl_str_mv Sato, Tatiana de Oliveira
dc.contributor.advisor1.fl_str_mv Coury, Helenice Jane Cote Gil
dc.contributor.advisor1Lattes.fl_str_mv http://genos.cnpq.br:12010/dwlattes/owa/prc_imp_cv_int?f_cod=K4781843Y6
dc.contributor.authorID.fl_str_mv dcf669d1-e61c-43e2-9f4b-ca358eb5dd8b
contributor_str_mv Coury, Helenice Jane Cote Gil
dc.subject.por.fl_str_mv Movimento
Articulação do joelho
Eletrogoniometro
Confiabilidade e Validade
topic Movimento
Articulação do joelho
Eletrogoniometro
Confiabilidade e Validade
CIENCIAS DA SAUDE::FISIOTERAPIA E TERAPIA OCUPACIONAL
dc.subject.cnpq.fl_str_mv CIENCIAS DA SAUDE::FISIOTERAPIA E TERAPIA OCUPACIONAL
description Flexible goniometers are useful for direct movement measurements. However issues related to subject-sensor interface can introduce measurement errors. Crosstalk, i.e. the phenomenon that flexion/extension angles affect the varus/valgus angles, and vice versa, is considered as the main drawback of goniometers. It is not well known the effect of the variation between identical sensors and the crosstalk due to endblocks misalignment in frontal and transverse planes. Thus, the objective of this study was to evaluate the effect of these sources of variation to goniometer recordings. A precision jig, for simulating pure flexion/extension angles, was constructed. Goniometer sensors were attached to this jig. In the initial study six biaxial goniometers were evaluated. Each sensor showed a consistent and specific crosstalk pattern. A procedure for correction for the inherent crosstalk, based on polynomial adjust, was proposed and evaluated. This procedure provided a major reduction of the inherent crosstalk. A second study was developed to evaluate the effect of endblocks misalignments. Results showed that varus/valgus misalignments did not cause additional errors for the recordings. Rotation between endblocks was the main source of error. Compensation procedures developed in the first study were applied in this second one, also resulting in crosstalk reduction. These compensations might be required in functional movement recordings to elucidate the crosstalk effect in knee measurements and the impact of the compensation procedures in measures, such as peaks, ranges of motion and movements curves.
publishDate 2008
dc.date.available.fl_str_mv 2008-07-11
2016-06-02T20:18:09Z
dc.date.issued.fl_str_mv 2008-06-17
dc.date.accessioned.fl_str_mv 2016-06-02T20:18:09Z
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
dc.type.driver.fl_str_mv info:eu-repo/semantics/doctoralThesis
format doctoralThesis
status_str publishedVersion
dc.identifier.citation.fl_str_mv SATO, Tatiana de Oliveira. Fontes de erro em medidas eletrogoniométricas de movimentos do joelho. 2008. 118 f. Tese (Doutorado em Ciências Biológicas) - Universidade Federal de São Carlos, São Carlos, 2008.
dc.identifier.uri.fl_str_mv https://repositorio.ufscar.br/handle/ufscar/5097
identifier_str_mv SATO, Tatiana de Oliveira. Fontes de erro em medidas eletrogoniométricas de movimentos do joelho. 2008. 118 f. Tese (Doutorado em Ciências Biológicas) - Universidade Federal de São Carlos, São Carlos, 2008.
url https://repositorio.ufscar.br/handle/ufscar/5097
dc.language.iso.fl_str_mv por
language por
dc.relation.confidence.fl_str_mv -1
-1
dc.relation.authority.fl_str_mv 9bbfa3f0-30d7-4fdb-b1a6-45490d6b3aa2
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv application/pdf
dc.publisher.none.fl_str_mv Universidade Federal de São Carlos
dc.publisher.program.fl_str_mv Programa de Pós-Graduação em Fisioterapia - PPGFt
dc.publisher.initials.fl_str_mv UFSCar
dc.publisher.country.fl_str_mv BR
publisher.none.fl_str_mv Universidade Federal de São Carlos
dc.source.none.fl_str_mv reponame:Repositório Institucional da UFSCAR
instname:Universidade Federal de São Carlos (UFSCAR)
instacron:UFSCAR
instname_str Universidade Federal de São Carlos (UFSCAR)
instacron_str UFSCAR
institution UFSCAR
reponame_str Repositório Institucional da UFSCAR
collection Repositório Institucional da UFSCAR
bitstream.url.fl_str_mv https://repositorio.ufscar.br/bitstream/ufscar/5097/1/1863.pdf
https://repositorio.ufscar.br/bitstream/ufscar/5097/2/1863.pdf.jpg
bitstream.checksum.fl_str_mv 34b9c585b1ad7b0d544335d19ed3db45
2c9b52174359b904890e102b99a2917f
bitstream.checksumAlgorithm.fl_str_mv MD5
MD5
repository.name.fl_str_mv Repositório Institucional da UFSCAR - Universidade Federal de São Carlos (UFSCAR)
repository.mail.fl_str_mv
_version_ 1802136282190577664