Construção e aplicação analítica de espectrômetro de emissão atômica com atomização eletrotérmica em filamento de tungstênio

Detalhes bibliográficos
Autor(a) principal: Gonzalez, Mário Henrique
Data de Publicação: 2011
Tipo de documento: Tese
Idioma: por
Título da fonte: Repositório Institucional da UFSCAR
Texto Completo: https://repositorio.ufscar.br/handle/ufscar/6185
Resumo: This thesis has two lines of development based on measurements of atomic emission using a tungsten coil electrothermal atomizer. The first line dealt with the construction of a tungsten coil atomic emission spectrometer (WCAES) with a portable monochromator connected to an array of charge-coupled devices as the detection system. Afterwards, the measurement of atomic emission by clouds generated by electrothermal atomization/excitation in a tungsten coil was evaluated. Instrumental conditions for measurements of transient emission signals, such as the position of the coil related to the entrance slit of the monochromator, the transfer of emitted radiation by the decay of excited atoms, and the sensitivity of array detectors, were critically evaluated. After establishing the instrumental conditions, the measurements of transient emission signals for Co and Mn were studied and applied for the determination of these metals. In this step, the occurrence of interferences due to the non-isothermal character of the open atomizer was systematically evaluated. The limits of detection (LOD) were approximately 0.33 to 0.48 mg/L for different cobalt emission lines and relative standard deviations (RSD) typically varied from 4.3 to 6.5 %. Spectral interferences were observed in the presence of Ni. For Mn, the performance parameters were LOD 0.54 to 0.65 mg/L and RSD 5.9 to 6.5 %. Using a strategy based on the summation of signals, LOD was 0.17 mg/L and RSD 1.7 %. Spectral interferences were observed in the presence of Al, Ca and Na. The developed methods were applied for accurate determination of Co and Mn in medicines and industrial alloy samples. Accuracy was determined with two certified reference materials: San Joaquim soil (NIST 2709) and industrial sludge (NIST 2782). Results obtained by WCAES were in agreement with ICP OES at a 95 % confidence level. The WCAES is simple and low cost equipment for performing analysis based on emission measurements, but requires the development of tailored analytical procedures for controlling matrix interferences.
id SCAR_2f84f22b9b6f8394dc305043fc997a25
oai_identifier_str oai:repositorio.ufscar.br:ufscar/6185
network_acronym_str SCAR
network_name_str Repositório Institucional da UFSCAR
repository_id_str 4322
spelling Gonzalez, Mário HenriqueNóbrega, Joaquim de Araújohttp://lattes.cnpq.br/8833989058164529http://lattes.cnpq.br/4080483059878501e81680eb-fc18-4fbf-a8e7-ddeeadb3c8582016-06-02T20:34:24Z2011-03-222016-06-02T20:34:24Z2011-02-04GONZALEZ, Mário Henrique. Construction and analytical application of a tungsten coil atomic emission spectrometer. 2011. 116 f. Tese (Doutorado em Ciências Exatas e da Terra) - Universidade Federal de São Carlos, São Carlos, 2011.https://repositorio.ufscar.br/handle/ufscar/6185This thesis has two lines of development based on measurements of atomic emission using a tungsten coil electrothermal atomizer. The first line dealt with the construction of a tungsten coil atomic emission spectrometer (WCAES) with a portable monochromator connected to an array of charge-coupled devices as the detection system. Afterwards, the measurement of atomic emission by clouds generated by electrothermal atomization/excitation in a tungsten coil was evaluated. Instrumental conditions for measurements of transient emission signals, such as the position of the coil related to the entrance slit of the monochromator, the transfer of emitted radiation by the decay of excited atoms, and the sensitivity of array detectors, were critically evaluated. After establishing the instrumental conditions, the measurements of transient emission signals for Co and Mn were studied and applied for the determination of these metals. In this step, the occurrence of interferences due to the non-isothermal character of the open atomizer was systematically evaluated. The limits of detection (LOD) were approximately 0.33 to 0.48 mg/L for different cobalt emission lines and relative standard deviations (RSD) typically varied from 4.3 to 6.5 %. Spectral interferences were observed in the presence of Ni. For Mn, the performance parameters were LOD 0.54 to 0.65 mg/L and RSD 5.9 to 6.5 %. Using a strategy based on the summation of signals, LOD was 0.17 mg/L and RSD 1.7 %. Spectral interferences were observed in the presence of Al, Ca and Na. The developed methods were applied for accurate determination of Co and Mn in medicines and industrial alloy samples. Accuracy was determined with two certified reference materials: San Joaquim soil (NIST 2709) and industrial sludge (NIST 2782). Results obtained by WCAES were in agreement with ICP OES at a 95 % confidence level. The WCAES is simple and low cost equipment for performing analysis based on emission measurements, but requires the development of tailored analytical procedures for controlling matrix interferences.Este trabalho de tese teve duas linhas de desenvolvimento baseadas em medidas de emissão atômica com filamento de tungstênio. A primeira etapa envolveu a construção de um espectrômetro de emissão atômica com filamento de tungstênio com monocromador associado a um arranjo de dispositivos de carga acoplada como sistema de detecção. A medida de emissão por nuvens atômicas geradas por atomização/excitação eletrotérmica no filamento de tungstênio foi avaliada. Foram otimizadas as condições instrumentais para medidas dos sinais transientes de emissão, sendo que a posição do filamento com relação à fenda de entrada do monocromador, a transferência da radiação emitida pela nuvem atômica até o monocromador e a sensibilidade do arranjo de detectores são parâmetros críticos a serem avaliados. Tendo estabelecido as condições instrumentais para medidas dos sinais transientes de emissão, foram desenvolvidos procedimentos para a determinação de Co e Mn. Nessa etapa avaliou se sistematicamente a ocorrência de interferências decorrentes do caráter não isotérmico do atomizador. Para cobalto, os valores de limite de detecção (LOD) foram entre 0,33 0,48 mg/L e repetibilidade de 4,3 6,5 %. Na presença de Ni, interferências espectrais foram observadas na determinação de Co. Para manganês, os parâmetros de desempenho foram LOD de 0,54 0,65 mg/L e RSD entre 5,9 6,5 %. Com o uso da somatória de intensidades de sinais o valor de LOD foram 0,17 mg/L e RSD 1,7%. As interferências mais acentuadas para Mn ocorreram na presença de Al, Ca e Na. O procedimento desenvolvido foi aplicado para amostras de medicamentos e liga metálica. A exatidão foi determinada empregando dois materiais de referência certificados: solo San Joaquin (NIST 2709) e lodo industrial (NIST 2782). Os resultados empregando WCAES foram concordantes com os obtidos por ICP OES para um nível de confiança de 95 %. O WCAES é um equipamento de baixo custo e simples para executar a análise baseada em medidas da emissão, mas exige o desenvolvimento de procedimentos analíticos apropriados para que haja o controle de problemas inerentes às interferências matriciais.Universidade Federal de Sao Carlosapplication/pdfporUniversidade Federal de São CarlosPrograma de Pós-Graduação em Química - PPGQUFSCarBRQuímica analíticaAtomização eletrotérmicaFilamento de tungstênioEspectrometria de emissão atômicaWCAESCIENCIAS EXATAS E DA TERRA::QUIMICAConstrução e aplicação analítica de espectrômetro de emissão atômica com atomização eletrotérmica em filamento de tungstênioConstruction and analytical application of a tungsten coil atomic emission spectrometerinfo:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/doctoralThesis-1-134c8c01d-b96b-428f-acbc-937c5a211684info:eu-repo/semantics/openAccessreponame:Repositório Institucional da UFSCARinstname:Universidade Federal de São Carlos (UFSCAR)instacron:UFSCARORIGINAL3465.pdfapplication/pdf3516269https://repositorio.ufscar.br/bitstream/ufscar/6185/1/3465.pdf06f2865c60e65736265f41600874a974MD51THUMBNAIL3465.pdf.jpg3465.pdf.jpgIM Thumbnailimage/jpeg10236https://repositorio.ufscar.br/bitstream/ufscar/6185/2/3465.pdf.jpg8aac7e3495d564443983c1bafd9ff005MD52ufscar/61852023-09-18 18:31:19.286oai:repositorio.ufscar.br:ufscar/6185Repositório InstitucionalPUBhttps://repositorio.ufscar.br/oai/requestopendoar:43222023-09-18T18:31:19Repositório Institucional da UFSCAR - Universidade Federal de São Carlos (UFSCAR)false
dc.title.por.fl_str_mv Construção e aplicação analítica de espectrômetro de emissão atômica com atomização eletrotérmica em filamento de tungstênio
dc.title.alternative.eng.fl_str_mv Construction and analytical application of a tungsten coil atomic emission spectrometer
title Construção e aplicação analítica de espectrômetro de emissão atômica com atomização eletrotérmica em filamento de tungstênio
spellingShingle Construção e aplicação analítica de espectrômetro de emissão atômica com atomização eletrotérmica em filamento de tungstênio
Gonzalez, Mário Henrique
Química analítica
Atomização eletrotérmica
Filamento de tungstênio
Espectrometria de emissão atômica
WCAES
CIENCIAS EXATAS E DA TERRA::QUIMICA
title_short Construção e aplicação analítica de espectrômetro de emissão atômica com atomização eletrotérmica em filamento de tungstênio
title_full Construção e aplicação analítica de espectrômetro de emissão atômica com atomização eletrotérmica em filamento de tungstênio
title_fullStr Construção e aplicação analítica de espectrômetro de emissão atômica com atomização eletrotérmica em filamento de tungstênio
title_full_unstemmed Construção e aplicação analítica de espectrômetro de emissão atômica com atomização eletrotérmica em filamento de tungstênio
title_sort Construção e aplicação analítica de espectrômetro de emissão atômica com atomização eletrotérmica em filamento de tungstênio
author Gonzalez, Mário Henrique
author_facet Gonzalez, Mário Henrique
author_role author
dc.contributor.authorlattes.por.fl_str_mv http://lattes.cnpq.br/4080483059878501
dc.contributor.author.fl_str_mv Gonzalez, Mário Henrique
dc.contributor.advisor1.fl_str_mv Nóbrega, Joaquim de Araújo
dc.contributor.advisor1Lattes.fl_str_mv http://lattes.cnpq.br/8833989058164529
dc.contributor.authorID.fl_str_mv e81680eb-fc18-4fbf-a8e7-ddeeadb3c858
contributor_str_mv Nóbrega, Joaquim de Araújo
dc.subject.por.fl_str_mv Química analítica
Atomização eletrotérmica
Filamento de tungstênio
Espectrometria de emissão atômica
WCAES
topic Química analítica
Atomização eletrotérmica
Filamento de tungstênio
Espectrometria de emissão atômica
WCAES
CIENCIAS EXATAS E DA TERRA::QUIMICA
dc.subject.cnpq.fl_str_mv CIENCIAS EXATAS E DA TERRA::QUIMICA
description This thesis has two lines of development based on measurements of atomic emission using a tungsten coil electrothermal atomizer. The first line dealt with the construction of a tungsten coil atomic emission spectrometer (WCAES) with a portable monochromator connected to an array of charge-coupled devices as the detection system. Afterwards, the measurement of atomic emission by clouds generated by electrothermal atomization/excitation in a tungsten coil was evaluated. Instrumental conditions for measurements of transient emission signals, such as the position of the coil related to the entrance slit of the monochromator, the transfer of emitted radiation by the decay of excited atoms, and the sensitivity of array detectors, were critically evaluated. After establishing the instrumental conditions, the measurements of transient emission signals for Co and Mn were studied and applied for the determination of these metals. In this step, the occurrence of interferences due to the non-isothermal character of the open atomizer was systematically evaluated. The limits of detection (LOD) were approximately 0.33 to 0.48 mg/L for different cobalt emission lines and relative standard deviations (RSD) typically varied from 4.3 to 6.5 %. Spectral interferences were observed in the presence of Ni. For Mn, the performance parameters were LOD 0.54 to 0.65 mg/L and RSD 5.9 to 6.5 %. Using a strategy based on the summation of signals, LOD was 0.17 mg/L and RSD 1.7 %. Spectral interferences were observed in the presence of Al, Ca and Na. The developed methods were applied for accurate determination of Co and Mn in medicines and industrial alloy samples. Accuracy was determined with two certified reference materials: San Joaquim soil (NIST 2709) and industrial sludge (NIST 2782). Results obtained by WCAES were in agreement with ICP OES at a 95 % confidence level. The WCAES is simple and low cost equipment for performing analysis based on emission measurements, but requires the development of tailored analytical procedures for controlling matrix interferences.
publishDate 2011
dc.date.available.fl_str_mv 2011-03-22
2016-06-02T20:34:24Z
dc.date.issued.fl_str_mv 2011-02-04
dc.date.accessioned.fl_str_mv 2016-06-02T20:34:24Z
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
dc.type.driver.fl_str_mv info:eu-repo/semantics/doctoralThesis
format doctoralThesis
status_str publishedVersion
dc.identifier.citation.fl_str_mv GONZALEZ, Mário Henrique. Construction and analytical application of a tungsten coil atomic emission spectrometer. 2011. 116 f. Tese (Doutorado em Ciências Exatas e da Terra) - Universidade Federal de São Carlos, São Carlos, 2011.
dc.identifier.uri.fl_str_mv https://repositorio.ufscar.br/handle/ufscar/6185
identifier_str_mv GONZALEZ, Mário Henrique. Construction and analytical application of a tungsten coil atomic emission spectrometer. 2011. 116 f. Tese (Doutorado em Ciências Exatas e da Terra) - Universidade Federal de São Carlos, São Carlos, 2011.
url https://repositorio.ufscar.br/handle/ufscar/6185
dc.language.iso.fl_str_mv por
language por
dc.relation.confidence.fl_str_mv -1
-1
dc.relation.authority.fl_str_mv 34c8c01d-b96b-428f-acbc-937c5a211684
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv application/pdf
dc.publisher.none.fl_str_mv Universidade Federal de São Carlos
dc.publisher.program.fl_str_mv Programa de Pós-Graduação em Química - PPGQ
dc.publisher.initials.fl_str_mv UFSCar
dc.publisher.country.fl_str_mv BR
publisher.none.fl_str_mv Universidade Federal de São Carlos
dc.source.none.fl_str_mv reponame:Repositório Institucional da UFSCAR
instname:Universidade Federal de São Carlos (UFSCAR)
instacron:UFSCAR
instname_str Universidade Federal de São Carlos (UFSCAR)
instacron_str UFSCAR
institution UFSCAR
reponame_str Repositório Institucional da UFSCAR
collection Repositório Institucional da UFSCAR
bitstream.url.fl_str_mv https://repositorio.ufscar.br/bitstream/ufscar/6185/1/3465.pdf
https://repositorio.ufscar.br/bitstream/ufscar/6185/2/3465.pdf.jpg
bitstream.checksum.fl_str_mv 06f2865c60e65736265f41600874a974
8aac7e3495d564443983c1bafd9ff005
bitstream.checksumAlgorithm.fl_str_mv MD5
MD5
repository.name.fl_str_mv Repositório Institucional da UFSCAR - Universidade Federal de São Carlos (UFSCAR)
repository.mail.fl_str_mv
_version_ 1813715549455122432