Determinação simultânea de íons metálicos por meio de técnicas eletroanalíticas e quimiométricas
Autor(a) principal: | |
---|---|
Data de Publicação: | 2011 |
Tipo de documento: | Dissertação |
Idioma: | por |
Título da fonte: | Repositório Institucional da UFSCAR |
Texto Completo: | https://repositorio.ufscar.br/handle/ufscar/6541 |
Resumo: | In this work, the determination of three metallic ions was performed, namely Zn2+, Cd2+ and Pb2+, in very different concentration range, from _g/L until mg/L, using differential pulse anodic stripping voltammetry over Carbon Fiber electrode where a Mercury film was deposited. Initially a factorial design of 23 was built where all possible combination among the ion concentrations were contemplated and in this way all interactions among the metallic ions were measured. The voltammetric curve was mean centered before the chemometric analysis. After that, the data were analysed using Partial Least Squares in the Principal Components domain was the used to quantify the ion concentration. The data treatment has been validated using cross and external validation methods. The final results showed low precision in the validation compared to those methods commonly used in the literature. After the chemometric treatment realized at first group of samples, two more groups in an extended concentration range, were built and tested using the same methodology. In these cases, again, the data validation lead to a low precision for practical application. It is important to emphasize that the low precision in the validation does not mean a chemotric approach to analyse electroanalytical data is not adequate, instead it means that among those chemometric technique, in the dissertation, we chose an inadequate one. |
id |
SCAR_4f397d18a9d0abd70f52b9c33ce11bba |
---|---|
oai_identifier_str |
oai:repositorio.ufscar.br:ufscar/6541 |
network_acronym_str |
SCAR |
network_name_str |
Repositório Institucional da UFSCAR |
repository_id_str |
4322 |
spelling |
Farias, Marco Antonio dos SantosSouza, Ernesto Chaves Pereira dehttp://lattes.cnpq.br/1505400360366643http://lattes.cnpq.br/2589951282251863042859b4-b9e6-4c57-9bc5-903d3b9f14f22016-06-02T20:36:41Z2012-11-212016-06-02T20:36:41Z2011-05-19FARIAS, Marco Antonio dos Santos. Simultaneous determinations of metallic ions using Eletroanalytical techniques and chemometric tools.. 2011. 134 f. Dissertação (Mestrado em Ciências Exatas e da Terra) - Universidade Federal de São Carlos, São Carlos, 2011.https://repositorio.ufscar.br/handle/ufscar/6541In this work, the determination of three metallic ions was performed, namely Zn2+, Cd2+ and Pb2+, in very different concentration range, from _g/L until mg/L, using differential pulse anodic stripping voltammetry over Carbon Fiber electrode where a Mercury film was deposited. Initially a factorial design of 23 was built where all possible combination among the ion concentrations were contemplated and in this way all interactions among the metallic ions were measured. The voltammetric curve was mean centered before the chemometric analysis. After that, the data were analysed using Partial Least Squares in the Principal Components domain was the used to quantify the ion concentration. The data treatment has been validated using cross and external validation methods. The final results showed low precision in the validation compared to those methods commonly used in the literature. After the chemometric treatment realized at first group of samples, two more groups in an extended concentration range, were built and tested using the same methodology. In these cases, again, the data validation lead to a low precision for practical application. It is important to emphasize that the low precision in the validation does not mean a chemotric approach to analyse electroanalytical data is not adequate, instead it means that among those chemometric technique, in the dissertation, we chose an inadequate one.Neste trabalho realizou-se a determinação simultânea de três cátions metálicos, sendo eles Zn2+, Cd2+ e Pb2+, em faixas de concentrações muito distintas, indo de _g/L a mg/L, utilizando a voltametria de redissolução anódica com pulso diferencial sobre um eletrodo de fibra de carbono onde fora depositado um filme de Mercúrio. Inicialmente realizou-se um planejamento experimental, do tipo fatorial 23, em uma faixa restrita de concentrações, entre 10 e 100 ug/L, para medir todas as combinações de concentração possíveis entre os cátions metálicos e assim se pudesse obter informações a respeito das interações entre os cátions. Em seguida, aplicou-se um tratamento quimiométrico para realizar a calibração multivariada e o método de regressão utilizado foi o dos mínimos quadrados parciais (PLS) no domínio das componentes principais. Antes desta análise, os voltamogramas foram prétratados. Após a obtenção da curva de calibração multivariada preparou-se amostras com concentrações intermediárias àquelas preparadas inicialmente, com o intuito de testar a capacidade do modelo proposto, prever concentrações de amostras desconhecidas, método conhecido como validação externa. O método de calibração multivariada levou, entretanto, a valores calculados pouco precisos, considerando aqueles descritos na literatura. Após a realização da calibração multivariada para o primeiro conjunto de amostras, prepararam-se outros dois conjuntos que foram adicionados ao primeiro com o intuito de observar o comportamento do modelo de regressão para uma faixa ampla de contrações entre 10 e 1500 ug/L. Também nestes casos, os resultados obtidos não atingiram uma precisão adequada para utilização prática. É importante frisar, entretanto, que os resultados pouco satisfatórios não significam que a abordagem utilizada não é adequada, mas sim que dentre as inúmeras técnicas quimiométricas existentes, escolheu-se uma que foi pouco eficiente no presente caso.Universidade Federal de Sao Carlosapplication/pdfporUniversidade Federal de São CarlosPrograma de Pós-Graduação em Química - PPGQUFSCarBRFísico-químicaVoltametriaCalibração multivariadaCIENCIAS EXATAS E DA TERRA::QUIMICADeterminação simultânea de íons metálicos por meio de técnicas eletroanalíticas e quimiométricasSimultaneous determinations of metallic ions using Eletroanalytical techniques and chemometric tools.info:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/masterThesis-1-116229a12-027e-4f0e-96b0-518d49092280info:eu-repo/semantics/openAccessreponame:Repositório Institucional da UFSCARinstname:Universidade Federal de São Carlos (UFSCAR)instacron:UFSCARORIGINAL4686.pdfapplication/pdf2480558https://repositorio.ufscar.br/bitstream/ufscar/6541/1/4686.pdfea316da322f59902f25cbfa5e613f316MD51TEXT4686.pdf.txt4686.pdf.txtExtracted texttext/plain0https://repositorio.ufscar.br/bitstream/ufscar/6541/4/4686.pdf.txtd41d8cd98f00b204e9800998ecf8427eMD54THUMBNAIL4686.pdf.jpg4686.pdf.jpgIM Thumbnailimage/jpeg9755https://repositorio.ufscar.br/bitstream/ufscar/6541/5/4686.pdf.jpgaed2ec5af9e04600c1a0ec71882713afMD55ufscar/65412023-09-18 18:30:39.592oai:repositorio.ufscar.br:ufscar/6541Repositório InstitucionalPUBhttps://repositorio.ufscar.br/oai/requestopendoar:43222023-09-18T18:30:39Repositório Institucional da UFSCAR - Universidade Federal de São Carlos (UFSCAR)false |
dc.title.por.fl_str_mv |
Determinação simultânea de íons metálicos por meio de técnicas eletroanalíticas e quimiométricas |
dc.title.alternative.eng.fl_str_mv |
Simultaneous determinations of metallic ions using Eletroanalytical techniques and chemometric tools. |
title |
Determinação simultânea de íons metálicos por meio de técnicas eletroanalíticas e quimiométricas |
spellingShingle |
Determinação simultânea de íons metálicos por meio de técnicas eletroanalíticas e quimiométricas Farias, Marco Antonio dos Santos Físico-química Voltametria Calibração multivariada CIENCIAS EXATAS E DA TERRA::QUIMICA |
title_short |
Determinação simultânea de íons metálicos por meio de técnicas eletroanalíticas e quimiométricas |
title_full |
Determinação simultânea de íons metálicos por meio de técnicas eletroanalíticas e quimiométricas |
title_fullStr |
Determinação simultânea de íons metálicos por meio de técnicas eletroanalíticas e quimiométricas |
title_full_unstemmed |
Determinação simultânea de íons metálicos por meio de técnicas eletroanalíticas e quimiométricas |
title_sort |
Determinação simultânea de íons metálicos por meio de técnicas eletroanalíticas e quimiométricas |
author |
Farias, Marco Antonio dos Santos |
author_facet |
Farias, Marco Antonio dos Santos |
author_role |
author |
dc.contributor.authorlattes.por.fl_str_mv |
http://lattes.cnpq.br/2589951282251863 |
dc.contributor.author.fl_str_mv |
Farias, Marco Antonio dos Santos |
dc.contributor.advisor1.fl_str_mv |
Souza, Ernesto Chaves Pereira de |
dc.contributor.advisor1Lattes.fl_str_mv |
http://lattes.cnpq.br/1505400360366643 |
dc.contributor.authorID.fl_str_mv |
042859b4-b9e6-4c57-9bc5-903d3b9f14f2 |
contributor_str_mv |
Souza, Ernesto Chaves Pereira de |
dc.subject.por.fl_str_mv |
Físico-química Voltametria Calibração multivariada |
topic |
Físico-química Voltametria Calibração multivariada CIENCIAS EXATAS E DA TERRA::QUIMICA |
dc.subject.cnpq.fl_str_mv |
CIENCIAS EXATAS E DA TERRA::QUIMICA |
description |
In this work, the determination of three metallic ions was performed, namely Zn2+, Cd2+ and Pb2+, in very different concentration range, from _g/L until mg/L, using differential pulse anodic stripping voltammetry over Carbon Fiber electrode where a Mercury film was deposited. Initially a factorial design of 23 was built where all possible combination among the ion concentrations were contemplated and in this way all interactions among the metallic ions were measured. The voltammetric curve was mean centered before the chemometric analysis. After that, the data were analysed using Partial Least Squares in the Principal Components domain was the used to quantify the ion concentration. The data treatment has been validated using cross and external validation methods. The final results showed low precision in the validation compared to those methods commonly used in the literature. After the chemometric treatment realized at first group of samples, two more groups in an extended concentration range, were built and tested using the same methodology. In these cases, again, the data validation lead to a low precision for practical application. It is important to emphasize that the low precision in the validation does not mean a chemotric approach to analyse electroanalytical data is not adequate, instead it means that among those chemometric technique, in the dissertation, we chose an inadequate one. |
publishDate |
2011 |
dc.date.issued.fl_str_mv |
2011-05-19 |
dc.date.available.fl_str_mv |
2012-11-21 2016-06-02T20:36:41Z |
dc.date.accessioned.fl_str_mv |
2016-06-02T20:36:41Z |
dc.type.status.fl_str_mv |
info:eu-repo/semantics/publishedVersion |
dc.type.driver.fl_str_mv |
info:eu-repo/semantics/masterThesis |
format |
masterThesis |
status_str |
publishedVersion |
dc.identifier.citation.fl_str_mv |
FARIAS, Marco Antonio dos Santos. Simultaneous determinations of metallic ions using Eletroanalytical techniques and chemometric tools.. 2011. 134 f. Dissertação (Mestrado em Ciências Exatas e da Terra) - Universidade Federal de São Carlos, São Carlos, 2011. |
dc.identifier.uri.fl_str_mv |
https://repositorio.ufscar.br/handle/ufscar/6541 |
identifier_str_mv |
FARIAS, Marco Antonio dos Santos. Simultaneous determinations of metallic ions using Eletroanalytical techniques and chemometric tools.. 2011. 134 f. Dissertação (Mestrado em Ciências Exatas e da Terra) - Universidade Federal de São Carlos, São Carlos, 2011. |
url |
https://repositorio.ufscar.br/handle/ufscar/6541 |
dc.language.iso.fl_str_mv |
por |
language |
por |
dc.relation.confidence.fl_str_mv |
-1 -1 |
dc.relation.authority.fl_str_mv |
16229a12-027e-4f0e-96b0-518d49092280 |
dc.rights.driver.fl_str_mv |
info:eu-repo/semantics/openAccess |
eu_rights_str_mv |
openAccess |
dc.format.none.fl_str_mv |
application/pdf |
dc.publisher.none.fl_str_mv |
Universidade Federal de São Carlos |
dc.publisher.program.fl_str_mv |
Programa de Pós-Graduação em Química - PPGQ |
dc.publisher.initials.fl_str_mv |
UFSCar |
dc.publisher.country.fl_str_mv |
BR |
publisher.none.fl_str_mv |
Universidade Federal de São Carlos |
dc.source.none.fl_str_mv |
reponame:Repositório Institucional da UFSCAR instname:Universidade Federal de São Carlos (UFSCAR) instacron:UFSCAR |
instname_str |
Universidade Federal de São Carlos (UFSCAR) |
instacron_str |
UFSCAR |
institution |
UFSCAR |
reponame_str |
Repositório Institucional da UFSCAR |
collection |
Repositório Institucional da UFSCAR |
bitstream.url.fl_str_mv |
https://repositorio.ufscar.br/bitstream/ufscar/6541/1/4686.pdf https://repositorio.ufscar.br/bitstream/ufscar/6541/4/4686.pdf.txt https://repositorio.ufscar.br/bitstream/ufscar/6541/5/4686.pdf.jpg |
bitstream.checksum.fl_str_mv |
ea316da322f59902f25cbfa5e613f316 d41d8cd98f00b204e9800998ecf8427e aed2ec5af9e04600c1a0ec71882713af |
bitstream.checksumAlgorithm.fl_str_mv |
MD5 MD5 MD5 |
repository.name.fl_str_mv |
Repositório Institucional da UFSCAR - Universidade Federal de São Carlos (UFSCAR) |
repository.mail.fl_str_mv |
|
_version_ |
1802136295471841280 |