Desenvolvimento de eletrodo modificado com filme de polianilina e estudo da viabilidade da aplicação analítica para catecolaminas

Detalhes bibliográficos
Autor(a) principal: Barbosa, Nathália Vieira
Data de Publicação: 2010
Tipo de documento: Dissertação
Idioma: por
Título da fonte: Repositório Institucional da UFSCAR
Texto Completo: https://repositorio.ufscar.br/handle/ufscar/6468
Resumo: This work describes the development of a polyaniline (PANI) film modified electrode for determination of dopamine (DA) in pharmaceutical formulation. The electropolymerization of PANI film on platinum electrode was performed by cyclic voltammetry in a solution containing 0.1 mol L-1 aniline monomer and 0.5 mol L-1 sulfuric acid. The study of PANI/Pt electrode electrochemical response for determination of DA was carried out by cyclic voltammetry and differential pulse voltammetry. The DA electrochemical responses was obtained after applying a cathodic pretreatment of the PANI electrode, that consisting in applied a potential of -0.7 V for 3 s before each voltammetric measurements. The DA determination by differential pulse voltammetry, presented a better response in 0.1 mol L-1 phosphate buffer solution at pH 6.5 and using the parameters of scan rate (v), pulse amplitude (a) and pulse increment (ΔEi) of 10 mV s-1, 50 mV and 2 mV, respectively. The calibration curve for dopamine presented linear response in the concentration range between 2.22x10-5 and 3.23x10-4 mol L-1, with detection and quantification limits of 1.80x10-5 and 6.00x10-5 mol L-1, respectively. DA recovery studies fulfilled in pharmaceutical formulation sample using PANI/Pt electrode showed recoveries between 98.0 and 104%. The results obtained with the modified electrode were in agreement with the spectrophotometric method with a relative error of 2.39%. The repeatability of PANI/Pt electrode responses was studied in solution of 1.0 mmol L-1 DA and a relative standard deviation of 2.68% was obtained for ten successive cyclic voltammetry carried out electrode cathodically pretreated before each measurement. The feasibility of analytical application of the proposed electrode for determination of catecholamines was evaluated for the adrenaline, noradrenaline and levodopa. The results obtained showed the applicability of the PANI/Pt electrode. The characterization of the PANI film, performed by field emission gun scanning electron microscopy, showed granular and fibrillar morphology which is a characteristic of PANI.
id SCAR_59b8964c61eba493d063f8c927a4c752
oai_identifier_str oai:repositorio.ufscar.br:ufscar/6468
network_acronym_str SCAR
network_name_str Repositório Institucional da UFSCAR
repository_id_str 4322
spelling Barbosa, Nathália VieiraFaria, Ronaldo Censihttp://lattes.cnpq.br/8659496864305621http://lattes.cnpq.br/7052464924811586a892eb87-156c-46e7-9534-b97ad4c490072016-06-02T20:36:26Z2010-08-172016-06-02T20:36:26Z2010-08-13BARBOSA, Nathália Vieira. Development of polyaniline film modified electrode and study of feasibility of analytical application for catecholamines. 2010. 86 f. Dissertação (Mestrado em Ciências Exatas e da Terra) - Universidade Federal de São Carlos, São Carlos, 2010.https://repositorio.ufscar.br/handle/ufscar/6468This work describes the development of a polyaniline (PANI) film modified electrode for determination of dopamine (DA) in pharmaceutical formulation. The electropolymerization of PANI film on platinum electrode was performed by cyclic voltammetry in a solution containing 0.1 mol L-1 aniline monomer and 0.5 mol L-1 sulfuric acid. The study of PANI/Pt electrode electrochemical response for determination of DA was carried out by cyclic voltammetry and differential pulse voltammetry. The DA electrochemical responses was obtained after applying a cathodic pretreatment of the PANI electrode, that consisting in applied a potential of -0.7 V for 3 s before each voltammetric measurements. The DA determination by differential pulse voltammetry, presented a better response in 0.1 mol L-1 phosphate buffer solution at pH 6.5 and using the parameters of scan rate (v), pulse amplitude (a) and pulse increment (ΔEi) of 10 mV s-1, 50 mV and 2 mV, respectively. The calibration curve for dopamine presented linear response in the concentration range between 2.22x10-5 and 3.23x10-4 mol L-1, with detection and quantification limits of 1.80x10-5 and 6.00x10-5 mol L-1, respectively. DA recovery studies fulfilled in pharmaceutical formulation sample using PANI/Pt electrode showed recoveries between 98.0 and 104%. The results obtained with the modified electrode were in agreement with the spectrophotometric method with a relative error of 2.39%. The repeatability of PANI/Pt electrode responses was studied in solution of 1.0 mmol L-1 DA and a relative standard deviation of 2.68% was obtained for ten successive cyclic voltammetry carried out electrode cathodically pretreated before each measurement. The feasibility of analytical application of the proposed electrode for determination of catecholamines was evaluated for the adrenaline, noradrenaline and levodopa. The results obtained showed the applicability of the PANI/Pt electrode. The characterization of the PANI film, performed by field emission gun scanning electron microscopy, showed granular and fibrillar morphology which is a characteristic of PANI.Este trabalho descreve o desenvolvimento de um eletrodo modificado com filme de polianilina (PANI) para a determinação de dopamina (DA) em formulação farmacêutica. A eletropolimerização do filme de PANI sobre eletrodo de platina foi realizada por meio da técnica de voltametria cíclica em solução contendo o monômero anilina 0,1 mol L-1 e ácido sulfúrico 0,5 mol L-1. O estudo da resposta eletroquímica do eletrodo de Pt/PANI para determinação de DA foi realizado por meio de medidas de voltametria cíclica e voltametria de pulso diferencial. A resposta eletroquímica para dopamina foi obtida após a realização de um pré-tratamento catódico do eletrodo de PANI, que consistiu em aplicar um potencial de -0,7 V por 3 s antes de cada medida voltamétrica. A determinação de dopamina, por meio da técnica de voltametria de pulso diferencial, apresentou melhor resposta em meio de solução tampão fosfato 0,1 mol L-1 pH 6,5 e utilizandose os parâmetros velocidade de varredura (v), amplitude de pulso (a) e incremento de pulso (ΔEi) iguais a 10 mV s-1, 50 mV e 2 mV, respectivamente. A curva analítica para dopamina apresentou resposta linear no intervalo de concentração entre 2,22x10-5 e 3,23x10-4 mol L-1, com limites de detecção e quantificação iguais a 1,80x10-5 e 6,00x10-5 mol L-1, respectivamente. Estudos de adição e recuperação para DA realizados em amostra farmacêutica utilizando-se o eletrodo de Pt/PANI apresentaram resultados de recuperação entre 98,0 e 104%. Os resultados obtidos com o eletrodo modificado foram concordantes com o método espectrofotométrico, com um erro relativo de 2,39%. A repetibilidade da resposta do eletrodo de Pt/PANI foi estudada em solução de DA 1,0 mmol L-1 sendo obtido um desvio padrão relativo igual a 2,68% em dez voltametrias cíclicas sucessivas realizadas com o eletrodo prétratado catodicamente antes de cada medida. A viabilidade da aplicação analítica do eletrodo proposto para determinação de catecolaminas foi avaliada para os analitos adrenalina, noradrenalina e levodopa. Os resultados obtidos demonstraram a viabilidade de aplicação do eletrodo. A caracterização do filme de PANI, realizada por meio da técnica de microscopia eletrônica de varredura por emissão de campo, mostrou que o filme possui morfologia granular e fibrilar, característica da PANI.Universidade Federal de Minas Geraisapplication/pdfporUniversidade Federal de São CarlosPrograma de Pós-Graduação em Química - PPGQUFSCarBRQuímica analíticaPolianilinaPolímeros condutoresDopaminaCatecolaminasEletrodos modificadosCIENCIAS EXATAS E DA TERRA::QUIMICADesenvolvimento de eletrodo modificado com filme de polianilina e estudo da viabilidade da aplicação analítica para catecolaminasDevelopment of polyaniline film modified electrode and study of feasibility of analytical application for catecholaminesinfo:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/masterThesis-1-10e05d8c5-0f80-49a6-98a8-b6645fe6f1e3info:eu-repo/semantics/openAccessreponame:Repositório Institucional da UFSCARinstname:Universidade Federal de São Carlos (UFSCAR)instacron:UFSCARORIGINAL3153.pdfapplication/pdf1282665https://repositorio.ufscar.br/bitstream/ufscar/6468/1/3153.pdf9903d8687944fd0f21bea57a112211e6MD51THUMBNAIL3153.pdf.jpg3153.pdf.jpgIM Thumbnailimage/jpeg9898https://repositorio.ufscar.br/bitstream/ufscar/6468/2/3153.pdf.jpg92c6393dce2a96b53475a55f020abe71MD52ufscar/64682023-09-18 18:31:11.732oai:repositorio.ufscar.br:ufscar/6468Repositório InstitucionalPUBhttps://repositorio.ufscar.br/oai/requestopendoar:43222023-09-18T18:31:11Repositório Institucional da UFSCAR - Universidade Federal de São Carlos (UFSCAR)false
dc.title.por.fl_str_mv Desenvolvimento de eletrodo modificado com filme de polianilina e estudo da viabilidade da aplicação analítica para catecolaminas
dc.title.alternative.eng.fl_str_mv Development of polyaniline film modified electrode and study of feasibility of analytical application for catecholamines
title Desenvolvimento de eletrodo modificado com filme de polianilina e estudo da viabilidade da aplicação analítica para catecolaminas
spellingShingle Desenvolvimento de eletrodo modificado com filme de polianilina e estudo da viabilidade da aplicação analítica para catecolaminas
Barbosa, Nathália Vieira
Química analítica
Polianilina
Polímeros condutores
Dopamina
Catecolaminas
Eletrodos modificados
CIENCIAS EXATAS E DA TERRA::QUIMICA
title_short Desenvolvimento de eletrodo modificado com filme de polianilina e estudo da viabilidade da aplicação analítica para catecolaminas
title_full Desenvolvimento de eletrodo modificado com filme de polianilina e estudo da viabilidade da aplicação analítica para catecolaminas
title_fullStr Desenvolvimento de eletrodo modificado com filme de polianilina e estudo da viabilidade da aplicação analítica para catecolaminas
title_full_unstemmed Desenvolvimento de eletrodo modificado com filme de polianilina e estudo da viabilidade da aplicação analítica para catecolaminas
title_sort Desenvolvimento de eletrodo modificado com filme de polianilina e estudo da viabilidade da aplicação analítica para catecolaminas
author Barbosa, Nathália Vieira
author_facet Barbosa, Nathália Vieira
author_role author
dc.contributor.authorlattes.por.fl_str_mv http://lattes.cnpq.br/7052464924811586
dc.contributor.author.fl_str_mv Barbosa, Nathália Vieira
dc.contributor.advisor1.fl_str_mv Faria, Ronaldo Censi
dc.contributor.advisor1Lattes.fl_str_mv http://lattes.cnpq.br/8659496864305621
dc.contributor.authorID.fl_str_mv a892eb87-156c-46e7-9534-b97ad4c49007
contributor_str_mv Faria, Ronaldo Censi
dc.subject.por.fl_str_mv Química analítica
Polianilina
Polímeros condutores
Dopamina
Catecolaminas
Eletrodos modificados
topic Química analítica
Polianilina
Polímeros condutores
Dopamina
Catecolaminas
Eletrodos modificados
CIENCIAS EXATAS E DA TERRA::QUIMICA
dc.subject.cnpq.fl_str_mv CIENCIAS EXATAS E DA TERRA::QUIMICA
description This work describes the development of a polyaniline (PANI) film modified electrode for determination of dopamine (DA) in pharmaceutical formulation. The electropolymerization of PANI film on platinum electrode was performed by cyclic voltammetry in a solution containing 0.1 mol L-1 aniline monomer and 0.5 mol L-1 sulfuric acid. The study of PANI/Pt electrode electrochemical response for determination of DA was carried out by cyclic voltammetry and differential pulse voltammetry. The DA electrochemical responses was obtained after applying a cathodic pretreatment of the PANI electrode, that consisting in applied a potential of -0.7 V for 3 s before each voltammetric measurements. The DA determination by differential pulse voltammetry, presented a better response in 0.1 mol L-1 phosphate buffer solution at pH 6.5 and using the parameters of scan rate (v), pulse amplitude (a) and pulse increment (ΔEi) of 10 mV s-1, 50 mV and 2 mV, respectively. The calibration curve for dopamine presented linear response in the concentration range between 2.22x10-5 and 3.23x10-4 mol L-1, with detection and quantification limits of 1.80x10-5 and 6.00x10-5 mol L-1, respectively. DA recovery studies fulfilled in pharmaceutical formulation sample using PANI/Pt electrode showed recoveries between 98.0 and 104%. The results obtained with the modified electrode were in agreement with the spectrophotometric method with a relative error of 2.39%. The repeatability of PANI/Pt electrode responses was studied in solution of 1.0 mmol L-1 DA and a relative standard deviation of 2.68% was obtained for ten successive cyclic voltammetry carried out electrode cathodically pretreated before each measurement. The feasibility of analytical application of the proposed electrode for determination of catecholamines was evaluated for the adrenaline, noradrenaline and levodopa. The results obtained showed the applicability of the PANI/Pt electrode. The characterization of the PANI film, performed by field emission gun scanning electron microscopy, showed granular and fibrillar morphology which is a characteristic of PANI.
publishDate 2010
dc.date.available.fl_str_mv 2010-08-17
2016-06-02T20:36:26Z
dc.date.issued.fl_str_mv 2010-08-13
dc.date.accessioned.fl_str_mv 2016-06-02T20:36:26Z
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
dc.type.driver.fl_str_mv info:eu-repo/semantics/masterThesis
format masterThesis
status_str publishedVersion
dc.identifier.citation.fl_str_mv BARBOSA, Nathália Vieira. Development of polyaniline film modified electrode and study of feasibility of analytical application for catecholamines. 2010. 86 f. Dissertação (Mestrado em Ciências Exatas e da Terra) - Universidade Federal de São Carlos, São Carlos, 2010.
dc.identifier.uri.fl_str_mv https://repositorio.ufscar.br/handle/ufscar/6468
identifier_str_mv BARBOSA, Nathália Vieira. Development of polyaniline film modified electrode and study of feasibility of analytical application for catecholamines. 2010. 86 f. Dissertação (Mestrado em Ciências Exatas e da Terra) - Universidade Federal de São Carlos, São Carlos, 2010.
url https://repositorio.ufscar.br/handle/ufscar/6468
dc.language.iso.fl_str_mv por
language por
dc.relation.confidence.fl_str_mv -1
-1
dc.relation.authority.fl_str_mv 0e05d8c5-0f80-49a6-98a8-b6645fe6f1e3
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv application/pdf
dc.publisher.none.fl_str_mv Universidade Federal de São Carlos
dc.publisher.program.fl_str_mv Programa de Pós-Graduação em Química - PPGQ
dc.publisher.initials.fl_str_mv UFSCar
dc.publisher.country.fl_str_mv BR
publisher.none.fl_str_mv Universidade Federal de São Carlos
dc.source.none.fl_str_mv reponame:Repositório Institucional da UFSCAR
instname:Universidade Federal de São Carlos (UFSCAR)
instacron:UFSCAR
instname_str Universidade Federal de São Carlos (UFSCAR)
instacron_str UFSCAR
institution UFSCAR
reponame_str Repositório Institucional da UFSCAR
collection Repositório Institucional da UFSCAR
bitstream.url.fl_str_mv https://repositorio.ufscar.br/bitstream/ufscar/6468/1/3153.pdf
https://repositorio.ufscar.br/bitstream/ufscar/6468/2/3153.pdf.jpg
bitstream.checksum.fl_str_mv 9903d8687944fd0f21bea57a112211e6
92c6393dce2a96b53475a55f020abe71
bitstream.checksumAlgorithm.fl_str_mv MD5
MD5
repository.name.fl_str_mv Repositório Institucional da UFSCAR - Universidade Federal de São Carlos (UFSCAR)
repository.mail.fl_str_mv
_version_ 1813715551850070016