Controle de complacência em simuladores cranianos

Detalhes bibliográficos
Autor(a) principal: Bezerra, Ítalo Gabriel
Data de Publicação: 2023
Tipo de documento: Trabalho de conclusão de curso
Idioma: por
Título da fonte: Repositório Institucional da UFSCAR
Texto Completo: https://repositorio.ufscar.br/handle/ufscar/17644
Resumo: Changes in intracranial pressure (ICP) are related to pathologies such as traumatic brain injury (TBI) and idiopathic intracranial hypertension (IIH). However, the direct access to the PIC, is complex and risky, since an invasive procedure is required to access the brain of patients, bringing the risk of infection and the need for a surgical center. Therefore, it is of great importance to develop technologies that can monitor the ICP in a non-invasive way. The central nervous system (CNS) has ICP autoregulation systems activated by changes in blood or fluid volume cerebrospinal fluid (CSF). The ratio between intracranial volume variation and ICP variation is called intracranial compliance (CIC). This project aimed to develop a compliance simulator to be applied in testing monitoring technologies of the ICP in a non-invasive way. This simulator used a PET bottle as the main element. In the development of this simulator, the behavior of pressure and complacency during infusions of water into the system. Complacency showed a tendency slightly decreasing linear. With test data from the cranial simulation system a complacency determinator was developed, a tool that relates complacency, the pressure, initial volume of water in the system, the initial volume of air and the infusion volume of water. The knowledge acquired in this project and the tool developed here will help researchers in more precise control of compliance during tests in simulators where it is necessary to know this parameter. In addition, the work carried out will help in the creation of more complex simulators.
id SCAR_8b844196f87cf48252f520f46738bf07
oai_identifier_str oai:repositorio.ufscar.br:ufscar/17644
network_acronym_str SCAR
network_name_str Repositório Institucional da UFSCAR
repository_id_str 4322
spelling Bezerra, Ítalo GabrielFerri, Fábio Aparecidohttp://lattes.cnpq.br/8314629367795792b3591414-5496-4317-b558-33d30a6976b82023-04-06T13:56:40Z2023-04-06T13:56:40Z2023-03-31BEZERRA, Ítalo Gabriel. Controle de complacência em simuladores cranianos. 2023. Trabalho de Conclusão de Curso (Graduação em Engenharia Física) – Universidade Federal de São Carlos, São Carlos, 2023. Disponível em: https://repositorio.ufscar.br/handle/ufscar/17644.https://repositorio.ufscar.br/handle/ufscar/17644Changes in intracranial pressure (ICP) are related to pathologies such as traumatic brain injury (TBI) and idiopathic intracranial hypertension (IIH). However, the direct access to the PIC, is complex and risky, since an invasive procedure is required to access the brain of patients, bringing the risk of infection and the need for a surgical center. Therefore, it is of great importance to develop technologies that can monitor the ICP in a non-invasive way. The central nervous system (CNS) has ICP autoregulation systems activated by changes in blood or fluid volume cerebrospinal fluid (CSF). The ratio between intracranial volume variation and ICP variation is called intracranial compliance (CIC). This project aimed to develop a compliance simulator to be applied in testing monitoring technologies of the ICP in a non-invasive way. This simulator used a PET bottle as the main element. In the development of this simulator, the behavior of pressure and complacency during infusions of water into the system. Complacency showed a tendency slightly decreasing linear. With test data from the cranial simulation system a complacency determinator was developed, a tool that relates complacency, the pressure, initial volume of water in the system, the initial volume of air and the infusion volume of water. The knowledge acquired in this project and the tool developed here will help researchers in more precise control of compliance during tests in simulators where it is necessary to know this parameter. In addition, the work carried out will help in the creation of more complex simulators.As alterações na pressão intracraniana (PIC) estão relacionadas à patologias como traumatismo cranioencefálico (TCE) e a hipertensão intracraniana idiopática (HII). Contudo, o acesso direto à PIC, é complexo e arriscado, uma vez que é necessário um procedimento invasivo para acessar o cérebro dos pacientes, trazendo o risco de infecção e a necessidade de um centro cirúrgico. Deste modo, é de grande importância o desenvolvimento de tecnologias que consigam monitorar a PIC de forma não invasiva. O sistema nervoso central (SNC) possui sistemas de autorregulação da PIC ativados por variações no volume de sangue ou líquido cefalorraquidiano (LCR). A razão entre a variação de volume intracraniano e a variação da PIC é chamada de complacência intracraniana (CIC). O presente projeto se propôs a desenvolver um simulador de complacência para ser aplicado nos testes de tecnologias de monitoramento da PIC de forma não invasiva. Este simulador utilizou uma garrafa PET como o principal elemento. No desenvolvimento deste simulador foi investigado o comportamento da pressão e da complacência durante infusões de água no sistema. A complacência apresentou uma tendência linear levemente decrescente. Com os dados dos testes do sistema de simulação craniana desenvolveu-se um determinador de complacência, uma ferramenta que relaciona a complacência, a pressão, volume inicial de água no sistema, o volume inicial de ar e o volume de infusão de água. O conhecimento adquirido neste projeto e a ferramenta desenvolvida aqui irá ajudar pesquisadores no controle mais preciso da complacência durante testes em simuladores onde é necessário conhecer esse parâmetro. Além disso, o trabalho realizado ajudará na criação de simuladores mais complexos.porUniversidade Federal de São CarlosCâmpus São CarlosEngenharia Física - EFiUFSCarAttribution-NonCommercial-NoDerivs 3.0 Brazilhttp://creativecommons.org/licenses/by-nc-nd/3.0/br/info:eu-repo/semantics/openAccessComplacênciaSimuladoresCIENCIAS EXATAS E DA TERRA::FISICAControle de complacência em simuladores cranianosCompliance control in cranial simulatorsinfo:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/bachelorThesisa174c3a0-937b-413d-a39a-269c5888fafbreponame:Repositório Institucional da UFSCARinstname:Universidade Federal de São Carlos (UFSCAR)instacron:UFSCARCC-LICENSElicense_rdflicense_rdfapplication/rdf+xml; charset=utf-8810https://repositorio.ufscar.br/bitstream/ufscar/17644/2/license_rdff337d95da1fce0a22c77480e5e9a7aecMD52ORIGINALTrabalho Final de Curso - Ítalo Gabriel Bezerra (corrigido).pdfTrabalho Final de Curso - Ítalo Gabriel Bezerra (corrigido).pdfapplication/pdf5056903https://repositorio.ufscar.br/bitstream/ufscar/17644/1/Trabalho%20Final%20de%20Curso%20-%20%c3%8dtalo%20Gabriel%20Bezerra%20%28corrigido%29.pdf8ea5cbed288d5dfa35869c4096bd345cMD51TEXTTrabalho Final de Curso - Ítalo Gabriel Bezerra (corrigido).pdf.txtTrabalho Final de Curso - Ítalo Gabriel Bezerra (corrigido).pdf.txtExtracted texttext/plain46235https://repositorio.ufscar.br/bitstream/ufscar/17644/3/Trabalho%20Final%20de%20Curso%20-%20%c3%8dtalo%20Gabriel%20Bezerra%20%28corrigido%29.pdf.txt2984b8bf8c372cfbd222f3f20f7a3501MD53THUMBNAILTrabalho Final de Curso - Ítalo Gabriel Bezerra (corrigido).pdf.jpgTrabalho Final de Curso - Ítalo Gabriel Bezerra (corrigido).pdf.jpgIM Thumbnailimage/jpeg6088https://repositorio.ufscar.br/bitstream/ufscar/17644/4/Trabalho%20Final%20de%20Curso%20-%20%c3%8dtalo%20Gabriel%20Bezerra%20%28corrigido%29.pdf.jpgf7d3a7e29ac3b8b67da784701543d541MD54ufscar/176442023-09-18 18:32:35.881oai:repositorio.ufscar.br:ufscar/17644Repositório InstitucionalPUBhttps://repositorio.ufscar.br/oai/requestopendoar:43222023-09-18T18:32:35Repositório Institucional da UFSCAR - Universidade Federal de São Carlos (UFSCAR)false
dc.title.por.fl_str_mv Controle de complacência em simuladores cranianos
dc.title.alternative.eng.fl_str_mv Compliance control in cranial simulators
title Controle de complacência em simuladores cranianos
spellingShingle Controle de complacência em simuladores cranianos
Bezerra, Ítalo Gabriel
Complacência
Simuladores
CIENCIAS EXATAS E DA TERRA::FISICA
title_short Controle de complacência em simuladores cranianos
title_full Controle de complacência em simuladores cranianos
title_fullStr Controle de complacência em simuladores cranianos
title_full_unstemmed Controle de complacência em simuladores cranianos
title_sort Controle de complacência em simuladores cranianos
author Bezerra, Ítalo Gabriel
author_facet Bezerra, Ítalo Gabriel
author_role author
dc.contributor.author.fl_str_mv Bezerra, Ítalo Gabriel
dc.contributor.advisor1.fl_str_mv Ferri, Fábio Aparecido
dc.contributor.advisor1Lattes.fl_str_mv http://lattes.cnpq.br/8314629367795792
dc.contributor.authorID.fl_str_mv b3591414-5496-4317-b558-33d30a6976b8
contributor_str_mv Ferri, Fábio Aparecido
dc.subject.por.fl_str_mv Complacência
Simuladores
topic Complacência
Simuladores
CIENCIAS EXATAS E DA TERRA::FISICA
dc.subject.cnpq.fl_str_mv CIENCIAS EXATAS E DA TERRA::FISICA
description Changes in intracranial pressure (ICP) are related to pathologies such as traumatic brain injury (TBI) and idiopathic intracranial hypertension (IIH). However, the direct access to the PIC, is complex and risky, since an invasive procedure is required to access the brain of patients, bringing the risk of infection and the need for a surgical center. Therefore, it is of great importance to develop technologies that can monitor the ICP in a non-invasive way. The central nervous system (CNS) has ICP autoregulation systems activated by changes in blood or fluid volume cerebrospinal fluid (CSF). The ratio between intracranial volume variation and ICP variation is called intracranial compliance (CIC). This project aimed to develop a compliance simulator to be applied in testing monitoring technologies of the ICP in a non-invasive way. This simulator used a PET bottle as the main element. In the development of this simulator, the behavior of pressure and complacency during infusions of water into the system. Complacency showed a tendency slightly decreasing linear. With test data from the cranial simulation system a complacency determinator was developed, a tool that relates complacency, the pressure, initial volume of water in the system, the initial volume of air and the infusion volume of water. The knowledge acquired in this project and the tool developed here will help researchers in more precise control of compliance during tests in simulators where it is necessary to know this parameter. In addition, the work carried out will help in the creation of more complex simulators.
publishDate 2023
dc.date.accessioned.fl_str_mv 2023-04-06T13:56:40Z
dc.date.available.fl_str_mv 2023-04-06T13:56:40Z
dc.date.issued.fl_str_mv 2023-03-31
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
dc.type.driver.fl_str_mv info:eu-repo/semantics/bachelorThesis
format bachelorThesis
status_str publishedVersion
dc.identifier.citation.fl_str_mv BEZERRA, Ítalo Gabriel. Controle de complacência em simuladores cranianos. 2023. Trabalho de Conclusão de Curso (Graduação em Engenharia Física) – Universidade Federal de São Carlos, São Carlos, 2023. Disponível em: https://repositorio.ufscar.br/handle/ufscar/17644.
dc.identifier.uri.fl_str_mv https://repositorio.ufscar.br/handle/ufscar/17644
identifier_str_mv BEZERRA, Ítalo Gabriel. Controle de complacência em simuladores cranianos. 2023. Trabalho de Conclusão de Curso (Graduação em Engenharia Física) – Universidade Federal de São Carlos, São Carlos, 2023. Disponível em: https://repositorio.ufscar.br/handle/ufscar/17644.
url https://repositorio.ufscar.br/handle/ufscar/17644
dc.language.iso.fl_str_mv por
language por
dc.relation.authority.fl_str_mv a174c3a0-937b-413d-a39a-269c5888fafb
dc.rights.driver.fl_str_mv Attribution-NonCommercial-NoDerivs 3.0 Brazil
http://creativecommons.org/licenses/by-nc-nd/3.0/br/
info:eu-repo/semantics/openAccess
rights_invalid_str_mv Attribution-NonCommercial-NoDerivs 3.0 Brazil
http://creativecommons.org/licenses/by-nc-nd/3.0/br/
eu_rights_str_mv openAccess
dc.publisher.none.fl_str_mv Universidade Federal de São Carlos
Câmpus São Carlos
Engenharia Física - EFi
dc.publisher.initials.fl_str_mv UFSCar
publisher.none.fl_str_mv Universidade Federal de São Carlos
Câmpus São Carlos
Engenharia Física - EFi
dc.source.none.fl_str_mv reponame:Repositório Institucional da UFSCAR
instname:Universidade Federal de São Carlos (UFSCAR)
instacron:UFSCAR
instname_str Universidade Federal de São Carlos (UFSCAR)
instacron_str UFSCAR
institution UFSCAR
reponame_str Repositório Institucional da UFSCAR
collection Repositório Institucional da UFSCAR
bitstream.url.fl_str_mv https://repositorio.ufscar.br/bitstream/ufscar/17644/2/license_rdf
https://repositorio.ufscar.br/bitstream/ufscar/17644/1/Trabalho%20Final%20de%20Curso%20-%20%c3%8dtalo%20Gabriel%20Bezerra%20%28corrigido%29.pdf
https://repositorio.ufscar.br/bitstream/ufscar/17644/3/Trabalho%20Final%20de%20Curso%20-%20%c3%8dtalo%20Gabriel%20Bezerra%20%28corrigido%29.pdf.txt
https://repositorio.ufscar.br/bitstream/ufscar/17644/4/Trabalho%20Final%20de%20Curso%20-%20%c3%8dtalo%20Gabriel%20Bezerra%20%28corrigido%29.pdf.jpg
bitstream.checksum.fl_str_mv f337d95da1fce0a22c77480e5e9a7aec
8ea5cbed288d5dfa35869c4096bd345c
2984b8bf8c372cfbd222f3f20f7a3501
f7d3a7e29ac3b8b67da784701543d541
bitstream.checksumAlgorithm.fl_str_mv MD5
MD5
MD5
MD5
repository.name.fl_str_mv Repositório Institucional da UFSCAR - Universidade Federal de São Carlos (UFSCAR)
repository.mail.fl_str_mv
_version_ 1813715661494419456