Biossegurança no controle da infecção hospitalar: desenvolvimento de imunossensor impedimétrico para detecção de Staphylococcus aureus em áreas críticas hospitalares

Detalhes bibliográficos
Autor(a) principal: Fialho, Ana Cristina Vasconcelos
Data de Publicação: 2011
Tipo de documento: Tese
Idioma: por
Título da fonte: Repositório Institucional da UFSCAR
Texto Completo: https://repositorio.ufscar.br/handle/ufscar/254
Resumo: The Biosafety is a very important tool for the Control of Hospital Infection establishing through methods, techniques and standards, measures to be adopted in order to prevent and control risks that may contribute to hospital infection. This work reports the development of an impedimetric immunosensor for detection of pathogenic bacteria, specifically Staphylococcus aureus (S. aureus), in hospital critical areas (Surgical Centers and Intensive Care Units) to contribute to the hospital infection control. Different parameters were studied: direct immobilization of protein A of S. aureus on the surface of the transducer or the working electrode (screen-printed electrode - SPE), immobilization of protein A on SPEs modified with self-assembled monolayers (SAMs) of cystamine (CYS) and glutaraldehyde (GA); different incubation times and dilutions were used for both modifiers as for protein A and anti- S. aureus antibodies; blocking with bovine serum albumin (BSA) and immunoassay (antigen-antibody reaction, Ag-Ab). Electrochemical techniques (electrochemical impedance spectroscopy - EIS and cyclic voltammetry - CV) and non electrochemical (microscopy) were used for the characterization and construction of the immunosensor. The impedance measurements and cyclic voltammetry showed the good results with self-assembled monolayer of cystamine 2 x 10-2 mol L-1 and glutaraldehyde 2,5% with incubation periods of 2 and 1h, respectively; immobilization of protein A 1:20 (tincub = 12 h) and anti-S. aureus monoclonal Ab (tincub = 3 h) and step blocking with 0.5% BSA (tincub = 1 h). For the Ag-Ab interaction S. aureus ATCC - 6535 strains (analyte) were used and incubation for 30 min. The immunosensor developed has proven to be an effective method for monitoring of S. aureus in a hospital environment and that can be applied as an indicative tool of the effectiveness of the standards and procedures applied to the control of hospital infection.
id SCAR_aab5fd4bd06027c34e623c864ca1046c
oai_identifier_str oai:repositorio.ufscar.br:ufscar/254
network_acronym_str SCAR
network_name_str Repositório Institucional da UFSCAR
repository_id_str 4322
spelling Fialho, Ana Cristina VasconcelosMoreira, Fernando Manuel Araújohttp://buscatextual.cnpq.br/buscatextual/visualizacv.do?id=E265134http://lattes.cnpq.br/77232104183388148dc7fb71-d24b-4b18-8584-01c5456dc6e72016-06-02T19:02:40Z2011-11-012016-06-02T19:02:40Z2011-10-21FIALHO, Ana Cristina Vasconcelos. Biosafety in the control of hospital infection: development of an impedimetric immunosensor for detection of Staphylococcus aureus in critical areas of hospitals. 2011. 196 f. Tese (Doutorado em Multidisciplinar) - Universidade Federal de São Carlos, São Carlos, 2011.https://repositorio.ufscar.br/handle/ufscar/254The Biosafety is a very important tool for the Control of Hospital Infection establishing through methods, techniques and standards, measures to be adopted in order to prevent and control risks that may contribute to hospital infection. This work reports the development of an impedimetric immunosensor for detection of pathogenic bacteria, specifically Staphylococcus aureus (S. aureus), in hospital critical areas (Surgical Centers and Intensive Care Units) to contribute to the hospital infection control. Different parameters were studied: direct immobilization of protein A of S. aureus on the surface of the transducer or the working electrode (screen-printed electrode - SPE), immobilization of protein A on SPEs modified with self-assembled monolayers (SAMs) of cystamine (CYS) and glutaraldehyde (GA); different incubation times and dilutions were used for both modifiers as for protein A and anti- S. aureus antibodies; blocking with bovine serum albumin (BSA) and immunoassay (antigen-antibody reaction, Ag-Ab). Electrochemical techniques (electrochemical impedance spectroscopy - EIS and cyclic voltammetry - CV) and non electrochemical (microscopy) were used for the characterization and construction of the immunosensor. The impedance measurements and cyclic voltammetry showed the good results with self-assembled monolayer of cystamine 2 x 10-2 mol L-1 and glutaraldehyde 2,5% with incubation periods of 2 and 1h, respectively; immobilization of protein A 1:20 (tincub = 12 h) and anti-S. aureus monoclonal Ab (tincub = 3 h) and step blocking with 0.5% BSA (tincub = 1 h). For the Ag-Ab interaction S. aureus ATCC - 6535 strains (analyte) were used and incubation for 30 min. The immunosensor developed has proven to be an effective method for monitoring of S. aureus in a hospital environment and that can be applied as an indicative tool of the effectiveness of the standards and procedures applied to the control of hospital infection.A Biossegurança constitui uma ferramenta de grande relevância para o Controle da Infecção Hospitalar estabelecendo através de métodos, técnicas e normas, condutas a serem adotadas com o intuito de prevenir e controlar os riscos que podem favorecer à infecção hospitalar. Este trabalho relata o desenvolvimento de um imunossensor impedimétrico para detecção de Staphylococcus aureus (S. aureus), em áreas críticas hospitalares (Centros Cirúrgicos e Unidades de Terapia Intensiva) visando contribuir para o controle de infecção hospitalar. Diferentes parâmetros foram estudados: imobilização direta da proteína A de S. aureus na superfície do transdutor ou eletrodo de trabalho (screen-printed electrode - SPE); imobilização da proteína A sobre SPEs modificados com monocamadas auto-organizadas (SAMs) de cistamina (CYS) e glutaraldeído (GA); diferentes tempos de incubação e diluições foram utilizados tanto para os modificadores como para a proteína A e anticorpos anti-S. aureus; bloqueio com soroalbumina bovina (SAB) e imunoensaio (reação antígeno-anticorpo, Ag-Ac). Técnicas eletroquímicas (espectroscopia de impedância eletroquímica - EIS e voltametria cíclica - VC) e não eletroquímicas (microscopias) foram utilizadas para a caracterização e construção do imunossensor. As medidas de impedância e voltametria cíclica mostraram bons resultados com monocamadas auto-organizadas de cistamina 2 x 10-2 mol L-1 e glutaraldeído 2,5% com tempos de incubação de 2 e 1 h, respectivamente;assim como as imobilizações da proteína A 1:20 (tincub = 12 h); Ac monoclonais anti-S. aureus (tincub = 3 h) e etapa de bloqueio com SAB 0,5% (tincub = 1 h). Na interação Ag-Ac utilizou-se cepas de S. aureus ATCC - 6535 (analito) e incubação de 30 min. O imunossensor desenvolvido indicou ser um método efetivo para monitoramento de S. aureus em ambiente hospitalar e que pode ser aplicado como instrumento indicativo da efetividade das normas e condutas aplicadas para o controle de infecção hospitalar.application/pdfporUniversidade Federal de São CarlosPrograma de Pós-Graduação em Biotecnologia - PPGBiotecUFSCarBRBiotecnologiaBiossegurançaInfecção hospitalarImunossensorEletrodos impressosStaphylococcus aureusBiosecurity hospitalHospital InfectionImmunosensorScreen-printed electrodesStaphylococcus aureusCIENCIAS DA SAUDEBiossegurança no controle da infecção hospitalar: desenvolvimento de imunossensor impedimétrico para detecção de Staphylococcus aureus em áreas críticas hospitalaresBiosafety in the control of hospital infection: development of an impedimetric immunosensor for detection of Staphylococcus aureus in critical areas of hospitalsinfo:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/doctoralThesis-1-1041b8a99-2c17-4a25-9ccb-49458db891fcinfo:eu-repo/semantics/openAccessreponame:Repositório Institucional da UFSCARinstname:Universidade Federal de São Carlos (UFSCAR)instacron:UFSCARORIGINAL3890.pdfapplication/pdf2739392https://repositorio.ufscar.br/bitstream/ufscar/254/1/3890.pdffdb93cb69cafb89992f3e6a155deacfbMD51TEXT3890.pdf.txt3890.pdf.txtExtracted texttext/plain0https://repositorio.ufscar.br/bitstream/ufscar/254/2/3890.pdf.txtd41d8cd98f00b204e9800998ecf8427eMD52THUMBNAIL3890.pdf.jpg3890.pdf.jpgIM Thumbnailimage/jpeg6579https://repositorio.ufscar.br/bitstream/ufscar/254/3/3890.pdf.jpg2e400a09600121c87b1787f1a92a510cMD53ufscar/2542023-09-18 18:31:27.135oai:repositorio.ufscar.br:ufscar/254Repositório InstitucionalPUBhttps://repositorio.ufscar.br/oai/requestopendoar:43222023-09-18T18:31:27Repositório Institucional da UFSCAR - Universidade Federal de São Carlos (UFSCAR)false
dc.title.por.fl_str_mv Biossegurança no controle da infecção hospitalar: desenvolvimento de imunossensor impedimétrico para detecção de Staphylococcus aureus em áreas críticas hospitalares
dc.title.alternative.eng.fl_str_mv Biosafety in the control of hospital infection: development of an impedimetric immunosensor for detection of Staphylococcus aureus in critical areas of hospitals
title Biossegurança no controle da infecção hospitalar: desenvolvimento de imunossensor impedimétrico para detecção de Staphylococcus aureus em áreas críticas hospitalares
spellingShingle Biossegurança no controle da infecção hospitalar: desenvolvimento de imunossensor impedimétrico para detecção de Staphylococcus aureus em áreas críticas hospitalares
Fialho, Ana Cristina Vasconcelos
Biotecnologia
Biossegurança
Infecção hospitalar
Imunossensor
Eletrodos impressos
Staphylococcus aureus
Biosecurity hospital
Hospital Infection
Immunosensor
Screen-printed electrodes
Staphylococcus aureus
CIENCIAS DA SAUDE
title_short Biossegurança no controle da infecção hospitalar: desenvolvimento de imunossensor impedimétrico para detecção de Staphylococcus aureus em áreas críticas hospitalares
title_full Biossegurança no controle da infecção hospitalar: desenvolvimento de imunossensor impedimétrico para detecção de Staphylococcus aureus em áreas críticas hospitalares
title_fullStr Biossegurança no controle da infecção hospitalar: desenvolvimento de imunossensor impedimétrico para detecção de Staphylococcus aureus em áreas críticas hospitalares
title_full_unstemmed Biossegurança no controle da infecção hospitalar: desenvolvimento de imunossensor impedimétrico para detecção de Staphylococcus aureus em áreas críticas hospitalares
title_sort Biossegurança no controle da infecção hospitalar: desenvolvimento de imunossensor impedimétrico para detecção de Staphylococcus aureus em áreas críticas hospitalares
author Fialho, Ana Cristina Vasconcelos
author_facet Fialho, Ana Cristina Vasconcelos
author_role author
dc.contributor.authorlattes.por.fl_str_mv http://lattes.cnpq.br/7723210418338814
dc.contributor.author.fl_str_mv Fialho, Ana Cristina Vasconcelos
dc.contributor.advisor1.fl_str_mv Moreira, Fernando Manuel Araújo
dc.contributor.advisor1Lattes.fl_str_mv http://buscatextual.cnpq.br/buscatextual/visualizacv.do?id=E265134
dc.contributor.authorID.fl_str_mv 8dc7fb71-d24b-4b18-8584-01c5456dc6e7
contributor_str_mv Moreira, Fernando Manuel Araújo
dc.subject.por.fl_str_mv Biotecnologia
Biossegurança
Infecção hospitalar
Imunossensor
Eletrodos impressos
Staphylococcus aureus
topic Biotecnologia
Biossegurança
Infecção hospitalar
Imunossensor
Eletrodos impressos
Staphylococcus aureus
Biosecurity hospital
Hospital Infection
Immunosensor
Screen-printed electrodes
Staphylococcus aureus
CIENCIAS DA SAUDE
dc.subject.eng.fl_str_mv Biosecurity hospital
Hospital Infection
Immunosensor
Screen-printed electrodes
Staphylococcus aureus
dc.subject.cnpq.fl_str_mv CIENCIAS DA SAUDE
description The Biosafety is a very important tool for the Control of Hospital Infection establishing through methods, techniques and standards, measures to be adopted in order to prevent and control risks that may contribute to hospital infection. This work reports the development of an impedimetric immunosensor for detection of pathogenic bacteria, specifically Staphylococcus aureus (S. aureus), in hospital critical areas (Surgical Centers and Intensive Care Units) to contribute to the hospital infection control. Different parameters were studied: direct immobilization of protein A of S. aureus on the surface of the transducer or the working electrode (screen-printed electrode - SPE), immobilization of protein A on SPEs modified with self-assembled monolayers (SAMs) of cystamine (CYS) and glutaraldehyde (GA); different incubation times and dilutions were used for both modifiers as for protein A and anti- S. aureus antibodies; blocking with bovine serum albumin (BSA) and immunoassay (antigen-antibody reaction, Ag-Ab). Electrochemical techniques (electrochemical impedance spectroscopy - EIS and cyclic voltammetry - CV) and non electrochemical (microscopy) were used for the characterization and construction of the immunosensor. The impedance measurements and cyclic voltammetry showed the good results with self-assembled monolayer of cystamine 2 x 10-2 mol L-1 and glutaraldehyde 2,5% with incubation periods of 2 and 1h, respectively; immobilization of protein A 1:20 (tincub = 12 h) and anti-S. aureus monoclonal Ab (tincub = 3 h) and step blocking with 0.5% BSA (tincub = 1 h). For the Ag-Ab interaction S. aureus ATCC - 6535 strains (analyte) were used and incubation for 30 min. The immunosensor developed has proven to be an effective method for monitoring of S. aureus in a hospital environment and that can be applied as an indicative tool of the effectiveness of the standards and procedures applied to the control of hospital infection.
publishDate 2011
dc.date.available.fl_str_mv 2011-11-01
2016-06-02T19:02:40Z
dc.date.issued.fl_str_mv 2011-10-21
dc.date.accessioned.fl_str_mv 2016-06-02T19:02:40Z
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
dc.type.driver.fl_str_mv info:eu-repo/semantics/doctoralThesis
format doctoralThesis
status_str publishedVersion
dc.identifier.citation.fl_str_mv FIALHO, Ana Cristina Vasconcelos. Biosafety in the control of hospital infection: development of an impedimetric immunosensor for detection of Staphylococcus aureus in critical areas of hospitals. 2011. 196 f. Tese (Doutorado em Multidisciplinar) - Universidade Federal de São Carlos, São Carlos, 2011.
dc.identifier.uri.fl_str_mv https://repositorio.ufscar.br/handle/ufscar/254
identifier_str_mv FIALHO, Ana Cristina Vasconcelos. Biosafety in the control of hospital infection: development of an impedimetric immunosensor for detection of Staphylococcus aureus in critical areas of hospitals. 2011. 196 f. Tese (Doutorado em Multidisciplinar) - Universidade Federal de São Carlos, São Carlos, 2011.
url https://repositorio.ufscar.br/handle/ufscar/254
dc.language.iso.fl_str_mv por
language por
dc.relation.confidence.fl_str_mv -1
-1
dc.relation.authority.fl_str_mv 041b8a99-2c17-4a25-9ccb-49458db891fc
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv application/pdf
dc.publisher.none.fl_str_mv Universidade Federal de São Carlos
dc.publisher.program.fl_str_mv Programa de Pós-Graduação em Biotecnologia - PPGBiotec
dc.publisher.initials.fl_str_mv UFSCar
dc.publisher.country.fl_str_mv BR
publisher.none.fl_str_mv Universidade Federal de São Carlos
dc.source.none.fl_str_mv reponame:Repositório Institucional da UFSCAR
instname:Universidade Federal de São Carlos (UFSCAR)
instacron:UFSCAR
instname_str Universidade Federal de São Carlos (UFSCAR)
instacron_str UFSCAR
institution UFSCAR
reponame_str Repositório Institucional da UFSCAR
collection Repositório Institucional da UFSCAR
bitstream.url.fl_str_mv https://repositorio.ufscar.br/bitstream/ufscar/254/1/3890.pdf
https://repositorio.ufscar.br/bitstream/ufscar/254/2/3890.pdf.txt
https://repositorio.ufscar.br/bitstream/ufscar/254/3/3890.pdf.jpg
bitstream.checksum.fl_str_mv fdb93cb69cafb89992f3e6a155deacfb
d41d8cd98f00b204e9800998ecf8427e
2e400a09600121c87b1787f1a92a510c
bitstream.checksumAlgorithm.fl_str_mv MD5
MD5
MD5
repository.name.fl_str_mv Repositório Institucional da UFSCAR - Universidade Federal de São Carlos (UFSCAR)
repository.mail.fl_str_mv
_version_ 1813715501644251136