Determinação e degradação eletroquímica do estrogênio natural estrona usando anodos de diamante dopado com boro
Autor(a) principal: | |
---|---|
Data de Publicação: | 2013 |
Tipo de documento: | Tese |
Idioma: | por |
Título da fonte: | Repositório Institucional da UFSCAR |
Texto Completo: | https://repositorio.ufscar.br/handle/ufscar/6290 |
Resumo: | Different electrochemical techniques were used to characterize the boron-doped diamond (BDD) electrode and to determine estrone. After parameters optimization, the detection limits obtained using differential pulse voltammetry (0.27 μmol L 1) and square-wave voltammetry (0.096 μmol L 1) with a cathodically pretreated BDD electrode were comparable to values reported in the literature. An even smaller value was obtained when amperometric detection was used with a flow injection system FIA-EC (0.050 μmol L 1), because there is a reduction of capacitive current interferences when a fixed potential is applied, as the continuous flow rate (surface cleaning and mass transport effect). In all cases, the BDD electrode presented a stable response (inter- and intra-day repeatabilities) and different matrices did not have significant influence on the detection of estrone. Consequently, the investigated techniques are promising for this purpose, with excellent accuracy and precision. In the electrochemical degradation of estrone studies in a flow reactor a rapid decay of estrone concentration was attained, due to the high oxidation power of the BDD electrode. This decay is dependent on the studied parameters (current density, flow rate, and pH); best results were attained at pH 3. Intermediate products formed during electrolyses of estrone at different pH (3, 7, and 10) were investigated by LC-MS/MS; thus, inedited (partial) degradation pathways were proposed, aiming at understanding the influence of pH on the generation of intermediates. Finally, electrochemical degradation of estrone at pH 7 using the BDD electrode was compared with the one attained with a β‒PbO2 electrode, also with an inedited mechanistic study. |
id |
SCAR_b98e0b2f8c3ac059c842123e75267b37 |
---|---|
oai_identifier_str |
oai:repositorio.ufscar.br:ufscar/6290 |
network_acronym_str |
SCAR |
network_name_str |
Repositório Institucional da UFSCAR |
repository_id_str |
4322 |
spelling |
Brocenschi, Ricardo FranciscoRocha Filho, Romeu Cardozohttp://genos.cnpq.br:12010/dwlattes/owa/prc_imp_cv_int?f_cod=K4780533J3http://lattes.cnpq.br/45307804320561751b4788d1-caca-4232-bc7d-83849c10a0b52016-06-02T20:34:49Z2014-02-192016-06-02T20:34:49Z2013-12-06BROCENSCHI, Ricardo Francisco. Electrochemical determination and degradation of the natural estrogen estrone using boron-doped diamond anodes. 2013. 224 f. Tese (Doutorado em Ciências Exatas e da Terra) - Universidade Federal de São Carlos, São Carlos, 2013.https://repositorio.ufscar.br/handle/ufscar/6290Different electrochemical techniques were used to characterize the boron-doped diamond (BDD) electrode and to determine estrone. After parameters optimization, the detection limits obtained using differential pulse voltammetry (0.27 μmol L 1) and square-wave voltammetry (0.096 μmol L 1) with a cathodically pretreated BDD electrode were comparable to values reported in the literature. An even smaller value was obtained when amperometric detection was used with a flow injection system FIA-EC (0.050 μmol L 1), because there is a reduction of capacitive current interferences when a fixed potential is applied, as the continuous flow rate (surface cleaning and mass transport effect). In all cases, the BDD electrode presented a stable response (inter- and intra-day repeatabilities) and different matrices did not have significant influence on the detection of estrone. Consequently, the investigated techniques are promising for this purpose, with excellent accuracy and precision. In the electrochemical degradation of estrone studies in a flow reactor a rapid decay of estrone concentration was attained, due to the high oxidation power of the BDD electrode. This decay is dependent on the studied parameters (current density, flow rate, and pH); best results were attained at pH 3. Intermediate products formed during electrolyses of estrone at different pH (3, 7, and 10) were investigated by LC-MS/MS; thus, inedited (partial) degradation pathways were proposed, aiming at understanding the influence of pH on the generation of intermediates. Finally, electrochemical degradation of estrone at pH 7 using the BDD electrode was compared with the one attained with a β‒PbO2 electrode, also with an inedited mechanistic study.Diferentes técnicas eletroquímicas foram usadas para caracterizar o eletrodo de diamante dopado com boro (BDD) e para a determinação de estrona. Após otimização de parâmetros, os valores de limite de detecção obtidos usando a voltametria de pulso diferencial (0,27 μmol L 1) e a voltametria de onda quadrada (0,096 μmol L 1) com o eletrodo de BDD prétratado catodicamente foram comparáveis àqueles na literatura. Um valor ainda menor foi obtido quando se utilizou detecção amperométrica em um sistema de injeção em fluxo FIA-EC (0,050 μmol L 1), dada a redução de interferências da corrente capacitiva pela aplicação de um potencial fixo, fluxo contínuo (transporte de massa e renovação de superfície do eletrodo). Em todos os casos, o eletrodo de BDD apresentou-se bastante estável (repetibilidade intra-dia e entre-dias) e diferentes matrizes não tiveram influências significantes na detecção da estrona. Consequentemente, as técnicas investigadas se mostraram promissoras para esse propósito, com excelentes precisão e exatidão. Na degradação eletroquímica de estrona em um reator em fluxo, devido ao alto poder oxidante do eletrodo de BDD, obteve-se um decaimento rápido da concentração de estrona, dependente das variáveis investigadas (densidade de corrente, vazão volumétrica e pH); melhores resultados foram obtidos a pH 3. Os intermediários formados durante eletrólises de estrona em diferentes pHs (3, 7 e 10) foram investigados por LCMS/ MS, sendo que rotas inéditas de degradação (parcial) foram propostas, no intuito de entender melhor a influência do pH na formação dos intermediários. Além disso, a degradação eletroquímica de estrona utilizando o eletrodo de BDD foi ainda comparada com a obtida com um eletrodo de β‒PbO2, também com estudo mecanístico inédito.Universidade Federal de Sao Carlosapplication/pdfporUniversidade Federal de São CarlosPrograma de Pós-Graduação em Química - PPGQUFSCarBREletroquímicaEletrodo de diamante dopado com Boro (DDB)Perturbadores endócrinosEstronaDegradação eletroquímica de estrogêniosDetecção eletroquímica de estronaCIENCIAS EXATAS E DA TERRA::QUIMICADeterminação e degradação eletroquímica do estrogênio natural estrona usando anodos de diamante dopado com boroElectrochemical determination and degradation of the natural estrogen estrone using boron-doped diamond anodesinfo:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/doctoralThesis-1-176089649-cb73-4b25-92ed-034536f1d04finfo:eu-repo/semantics/openAccessreponame:Repositório Institucional da UFSCARinstname:Universidade Federal de São Carlos (UFSCAR)instacron:UFSCARORIGINAL5699.pdfapplication/pdf4598797https://repositorio.ufscar.br/bitstream/ufscar/6290/1/5699.pdf3d3bdd7719250cba1af6bbb0169b7216MD51TEXT5699.pdf.txt5699.pdf.txtExtracted texttext/plain0https://repositorio.ufscar.br/bitstream/ufscar/6290/4/5699.pdf.txtd41d8cd98f00b204e9800998ecf8427eMD54THUMBNAIL5699.pdf.jpg5699.pdf.jpgIM Thumbnailimage/jpeg10412https://repositorio.ufscar.br/bitstream/ufscar/6290/5/5699.pdf.jpg06cda4f20cc728ffe50700f54831bf94MD55ufscar/62902023-09-18 18:31:52.023oai:repositorio.ufscar.br:ufscar/6290Repositório InstitucionalPUBhttps://repositorio.ufscar.br/oai/requestopendoar:43222023-09-18T18:31:52Repositório Institucional da UFSCAR - Universidade Federal de São Carlos (UFSCAR)false |
dc.title.por.fl_str_mv |
Determinação e degradação eletroquímica do estrogênio natural estrona usando anodos de diamante dopado com boro |
dc.title.alternative.eng.fl_str_mv |
Electrochemical determination and degradation of the natural estrogen estrone using boron-doped diamond anodes |
title |
Determinação e degradação eletroquímica do estrogênio natural estrona usando anodos de diamante dopado com boro |
spellingShingle |
Determinação e degradação eletroquímica do estrogênio natural estrona usando anodos de diamante dopado com boro Brocenschi, Ricardo Francisco Eletroquímica Eletrodo de diamante dopado com Boro (DDB) Perturbadores endócrinos Estrona Degradação eletroquímica de estrogênios Detecção eletroquímica de estrona CIENCIAS EXATAS E DA TERRA::QUIMICA |
title_short |
Determinação e degradação eletroquímica do estrogênio natural estrona usando anodos de diamante dopado com boro |
title_full |
Determinação e degradação eletroquímica do estrogênio natural estrona usando anodos de diamante dopado com boro |
title_fullStr |
Determinação e degradação eletroquímica do estrogênio natural estrona usando anodos de diamante dopado com boro |
title_full_unstemmed |
Determinação e degradação eletroquímica do estrogênio natural estrona usando anodos de diamante dopado com boro |
title_sort |
Determinação e degradação eletroquímica do estrogênio natural estrona usando anodos de diamante dopado com boro |
author |
Brocenschi, Ricardo Francisco |
author_facet |
Brocenschi, Ricardo Francisco |
author_role |
author |
dc.contributor.authorlattes.por.fl_str_mv |
http://lattes.cnpq.br/4530780432056175 |
dc.contributor.author.fl_str_mv |
Brocenschi, Ricardo Francisco |
dc.contributor.advisor1.fl_str_mv |
Rocha Filho, Romeu Cardozo |
dc.contributor.advisor1Lattes.fl_str_mv |
http://genos.cnpq.br:12010/dwlattes/owa/prc_imp_cv_int?f_cod=K4780533J3 |
dc.contributor.authorID.fl_str_mv |
1b4788d1-caca-4232-bc7d-83849c10a0b5 |
contributor_str_mv |
Rocha Filho, Romeu Cardozo |
dc.subject.por.fl_str_mv |
Eletroquímica Eletrodo de diamante dopado com Boro (DDB) Perturbadores endócrinos Estrona Degradação eletroquímica de estrogênios Detecção eletroquímica de estrona |
topic |
Eletroquímica Eletrodo de diamante dopado com Boro (DDB) Perturbadores endócrinos Estrona Degradação eletroquímica de estrogênios Detecção eletroquímica de estrona CIENCIAS EXATAS E DA TERRA::QUIMICA |
dc.subject.cnpq.fl_str_mv |
CIENCIAS EXATAS E DA TERRA::QUIMICA |
description |
Different electrochemical techniques were used to characterize the boron-doped diamond (BDD) electrode and to determine estrone. After parameters optimization, the detection limits obtained using differential pulse voltammetry (0.27 μmol L 1) and square-wave voltammetry (0.096 μmol L 1) with a cathodically pretreated BDD electrode were comparable to values reported in the literature. An even smaller value was obtained when amperometric detection was used with a flow injection system FIA-EC (0.050 μmol L 1), because there is a reduction of capacitive current interferences when a fixed potential is applied, as the continuous flow rate (surface cleaning and mass transport effect). In all cases, the BDD electrode presented a stable response (inter- and intra-day repeatabilities) and different matrices did not have significant influence on the detection of estrone. Consequently, the investigated techniques are promising for this purpose, with excellent accuracy and precision. In the electrochemical degradation of estrone studies in a flow reactor a rapid decay of estrone concentration was attained, due to the high oxidation power of the BDD electrode. This decay is dependent on the studied parameters (current density, flow rate, and pH); best results were attained at pH 3. Intermediate products formed during electrolyses of estrone at different pH (3, 7, and 10) were investigated by LC-MS/MS; thus, inedited (partial) degradation pathways were proposed, aiming at understanding the influence of pH on the generation of intermediates. Finally, electrochemical degradation of estrone at pH 7 using the BDD electrode was compared with the one attained with a β‒PbO2 electrode, also with an inedited mechanistic study. |
publishDate |
2013 |
dc.date.issued.fl_str_mv |
2013-12-06 |
dc.date.available.fl_str_mv |
2014-02-19 2016-06-02T20:34:49Z |
dc.date.accessioned.fl_str_mv |
2016-06-02T20:34:49Z |
dc.type.status.fl_str_mv |
info:eu-repo/semantics/publishedVersion |
dc.type.driver.fl_str_mv |
info:eu-repo/semantics/doctoralThesis |
format |
doctoralThesis |
status_str |
publishedVersion |
dc.identifier.citation.fl_str_mv |
BROCENSCHI, Ricardo Francisco. Electrochemical determination and degradation of the natural estrogen estrone using boron-doped diamond anodes. 2013. 224 f. Tese (Doutorado em Ciências Exatas e da Terra) - Universidade Federal de São Carlos, São Carlos, 2013. |
dc.identifier.uri.fl_str_mv |
https://repositorio.ufscar.br/handle/ufscar/6290 |
identifier_str_mv |
BROCENSCHI, Ricardo Francisco. Electrochemical determination and degradation of the natural estrogen estrone using boron-doped diamond anodes. 2013. 224 f. Tese (Doutorado em Ciências Exatas e da Terra) - Universidade Federal de São Carlos, São Carlos, 2013. |
url |
https://repositorio.ufscar.br/handle/ufscar/6290 |
dc.language.iso.fl_str_mv |
por |
language |
por |
dc.relation.confidence.fl_str_mv |
-1 -1 |
dc.relation.authority.fl_str_mv |
76089649-cb73-4b25-92ed-034536f1d04f |
dc.rights.driver.fl_str_mv |
info:eu-repo/semantics/openAccess |
eu_rights_str_mv |
openAccess |
dc.format.none.fl_str_mv |
application/pdf |
dc.publisher.none.fl_str_mv |
Universidade Federal de São Carlos |
dc.publisher.program.fl_str_mv |
Programa de Pós-Graduação em Química - PPGQ |
dc.publisher.initials.fl_str_mv |
UFSCar |
dc.publisher.country.fl_str_mv |
BR |
publisher.none.fl_str_mv |
Universidade Federal de São Carlos |
dc.source.none.fl_str_mv |
reponame:Repositório Institucional da UFSCAR instname:Universidade Federal de São Carlos (UFSCAR) instacron:UFSCAR |
instname_str |
Universidade Federal de São Carlos (UFSCAR) |
instacron_str |
UFSCAR |
institution |
UFSCAR |
reponame_str |
Repositório Institucional da UFSCAR |
collection |
Repositório Institucional da UFSCAR |
bitstream.url.fl_str_mv |
https://repositorio.ufscar.br/bitstream/ufscar/6290/1/5699.pdf https://repositorio.ufscar.br/bitstream/ufscar/6290/4/5699.pdf.txt https://repositorio.ufscar.br/bitstream/ufscar/6290/5/5699.pdf.jpg |
bitstream.checksum.fl_str_mv |
3d3bdd7719250cba1af6bbb0169b7216 d41d8cd98f00b204e9800998ecf8427e 06cda4f20cc728ffe50700f54831bf94 |
bitstream.checksumAlgorithm.fl_str_mv |
MD5 MD5 MD5 |
repository.name.fl_str_mv |
Repositório Institucional da UFSCAR - Universidade Federal de São Carlos (UFSCAR) |
repository.mail.fl_str_mv |
|
_version_ |
1802136293305483264 |