Dual energy X-Ray absorptiometry: desenvolvimento, validação e reprodutibilidade de recomendações técnicas para osteoartrite de ratos

Detalhes bibliográficos
Autor(a) principal: Araújo, Camila Marques de
Data de Publicação: 2021
Tipo de documento: Dissertação
Idioma: por
Título da fonte: Repositório Institucional da UFSCAR
Texto Completo: https://repositorio.ufscar.br/handle/ufscar/14651
Resumo: Objective: The aim of the present study is to develop, validate and make reproducible standardized anatomical regions of interest for bone mineral density (BMD) and bone mineral content (BMO) of rat knee at different times of osteoarthritis (OA) by formulating a guide to recommendations techniques for using dual energy X-ray absorptiometry (DXA). Methodology: 7 male winstar rats were used, divided into 2 groups entitled Osteoarthritis (OA) (n=6) and Test (T) (N=1). The OA group underwent transection of the anterior cruciate ligament for OA induction in the 14th week. The animals were anesthetized and scanned by DXA at the 14th, 19th and 24th weeks. After the scan, all images of the animals were analyzed using the software in specific and high-resolution small animal mode (resolution: 311 μm²) and anatomical regions of interest were made in the bones often associated with OA of the knee, femur and tibia. they were named Distal Femur and Proximal Tibia. In sequence, the technical recommendations guide was developed, validated and made reproducible, with norms and standardizations of the techniques for using the DXA, containing specific guidelines for the pre and post-test and preparation of regions of interest. The evaluators were divided into two groups with 2 members each, the evaluators were classified as experienced and inexperienced. Training was carried out to perform the positioning of the animal and selection of regions of interest for experienced and inexperienced evaluators. The evaluators carried out the proposed activities following the new recommendation guide made without any interference from the researcher using the group T mouse. Results: The validations of the regions of interest together with the formulation of technical recommendations formulated a valid and reliable basis for evaluating the BMD and CMO at different times of knee OA. Conclusion: The uses of the validated regions of interest and the recommendations guide make analyzes objective and less biased, increasing the efficiency of research standardization.
id SCAR_cdfdb14a4ddc7bb6e0115ea56437d5b1
oai_identifier_str oai:repositorio.ufscar.br:ufscar/14651
network_acronym_str SCAR
network_name_str Repositório Institucional da UFSCAR
repository_id_str 4322
spelling Araújo, Camila Marques deVasilceac, Fernando Augustohttp://lattes.cnpq.br/1220838672192063http://lattes.cnpq.br/94396996881349717f9e0bea-cf46-461c-869c-26b5e1f6afe22021-07-22T12:24:51Z2021-07-22T12:24:51Z2021-05-28ARAÚJO, Camila Marques de. Dual energy X-Ray absorptiometry: desenvolvimento, validação e reprodutibilidade de recomendações técnicas para osteoartrite de ratos. 2021. Dissertação (Mestrado em Gerontologia) – Universidade Federal de São Carlos, São Carlos, 2021. Disponível em: https://repositorio.ufscar.br/handle/ufscar/14651.https://repositorio.ufscar.br/handle/ufscar/14651Objective: The aim of the present study is to develop, validate and make reproducible standardized anatomical regions of interest for bone mineral density (BMD) and bone mineral content (BMO) of rat knee at different times of osteoarthritis (OA) by formulating a guide to recommendations techniques for using dual energy X-ray absorptiometry (DXA). Methodology: 7 male winstar rats were used, divided into 2 groups entitled Osteoarthritis (OA) (n=6) and Test (T) (N=1). The OA group underwent transection of the anterior cruciate ligament for OA induction in the 14th week. The animals were anesthetized and scanned by DXA at the 14th, 19th and 24th weeks. After the scan, all images of the animals were analyzed using the software in specific and high-resolution small animal mode (resolution: 311 μm²) and anatomical regions of interest were made in the bones often associated with OA of the knee, femur and tibia. they were named Distal Femur and Proximal Tibia. In sequence, the technical recommendations guide was developed, validated and made reproducible, with norms and standardizations of the techniques for using the DXA, containing specific guidelines for the pre and post-test and preparation of regions of interest. The evaluators were divided into two groups with 2 members each, the evaluators were classified as experienced and inexperienced. Training was carried out to perform the positioning of the animal and selection of regions of interest for experienced and inexperienced evaluators. The evaluators carried out the proposed activities following the new recommendation guide made without any interference from the researcher using the group T mouse. Results: The validations of the regions of interest together with the formulation of technical recommendations formulated a valid and reliable basis for evaluating the BMD and CMO at different times of knee OA. Conclusion: The uses of the validated regions of interest and the recommendations guide make analyzes objective and less biased, increasing the efficiency of research standardization.Objetivo: O objetivo do presente estudo é desenvolver, validar e tornar reprodutível regiões de interesse anatômicas padronizadas para densidade mineral óssea (DMO) e conteúdo mineral ósseo (CMO) de joelho de ratos em diferentes tempos da osteoartrite (OA) formulando um guia de recomendações técnicas para utilização do Absorciometria de raios X de dupla energia, (DXA). Metodologia: Foram utilizados 7 ratos machos da raça winstar divididos em 2 grupos intitulados Osteoartrite (OA) (n=6) e Teste (T) (N=1). O grupo OA grupo foi submetido a transeção do ligamento cruzado anterior para indução da OA na 14º semana. Os animais foram anestesiados e escaneados pelo DXA na 14º, 19º e 24º semanas. Posterirormente ao escaneamento todas as imagens dos animais foram analisadas utilizando o software no modo pequenos animais especifico e de alta resolução (resolução: 311 μm²) e foram confeccionadas regiões de interesse anatômicas nos ossos frequentemente associados a OA de joelho fêmur e tíbia as regiões de interesse foram intituladas Fêmur Distal e Tíbia Proximal. Em sequência, foi desenvolvido, validado e tornado reprodutível o guia de recomendações técnicas com normatizações e padronizações das técnicas para utilização do DXA contendendo orientações especificas para o pré e pós teste e confecção de regiões de interesse. Os avaliadores forem divididos em dois grupos com 2 integrantes cada um os avaliadores foram classificados em experientes e inexperientes. Foram realizados treinamentos para realização do posicionamento do animal e seleção de regiões de interesse para os avaliadores experientes e inexperientes. Os avaliadores realizaram as atividades propostas seguindo o novo guia de recomendação confeccionados sem nenhuma interferência da pesquisadora utilizando o rato do grupo T. Resultados: As validações das regiões de interesse em conjunto da formulação das recomendações técnicas formularam uma base válida e confiável para avaliar a DMO e CMO em diferentes tempos de OA de joelho. Conclusão: Os usos das regiões de interesse validadas e do guia de recomendações tornam analises objetivas e menos tendenciosa aumentando a eficiência nas padronizações de pesquisasCoordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)CAPES: código de financiamento - 001porUniversidade Federal de São CarlosCâmpus São CarlosPrograma de Pós-Graduação em Gerontologia - PPGGeroUFSCarAttribution-NonCommercial-NoDerivs 3.0 Brazilhttp://creativecommons.org/licenses/by-nc-nd/3.0/br/info:eu-repo/semantics/openAccessOsteoartriteAbsorciometria de raios x de dupla energiaregião de interesse,ValidaçãoOsteoarthritisDual energy X-ray absorptiometryRegion of interestValidationCIENCIAS BIOLOGICASDual energy X-Ray absorptiometry: desenvolvimento, validação e reprodutibilidade de recomendações técnicas para osteoartrite de ratosEnergy X-Ray Absorptiometry: development, validation and reproducibility of technical recommendations for rat with osteoarthritisinfo:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/masterThesis600ff051788-91c5-4a09-9867-9b3aac7fdef1reponame:Repositório Institucional da UFSCARinstname:Universidade Federal de São Carlos (UFSCAR)instacron:UFSCARORIGINALDissertação_Camila_Marques_de_Araújo_2021_UFSCar.pdfDissertação_Camila_Marques_de_Araújo_2021_UFSCar.pdfDissertação para obtenção do titulo de mestre em Gerontologiaapplication/pdf12126939https://repositorio.ufscar.br/bitstream/ufscar/14651/4/Disserta%c3%a7%c3%a3o_Camila_Marques_de_Ara%c3%bajo_2021_UFSCar.pdf13b0d4c431d564cc05e4ed816d62eb84MD54Carta-Comprovante_Camila_Marques_de_Araújo.pdfCarta-Comprovante_Camila_Marques_de_Araújo.pdfCarta comprovante assinada pelo orientador Prof. Dr. Fernando Augusto Vasilceacapplication/pdf187721https://repositorio.ufscar.br/bitstream/ufscar/14651/5/Carta-Comprovante_Camila_Marques_de_Ara%c3%bajo.pdf42d44487f54b53aebcf4581e8951fd36MD55CC-LICENSElicense_rdflicense_rdfapplication/rdf+xml; charset=utf-8811https://repositorio.ufscar.br/bitstream/ufscar/14651/6/license_rdfe39d27027a6cc9cb039ad269a5db8e34MD56TEXTDissertação_Camila_Marques_de_Araújo_2021_UFSCar.pdf.txtDissertação_Camila_Marques_de_Araújo_2021_UFSCar.pdf.txtExtracted texttext/plain91674https://repositorio.ufscar.br/bitstream/ufscar/14651/7/Disserta%c3%a7%c3%a3o_Camila_Marques_de_Ara%c3%bajo_2021_UFSCar.pdf.txt97f95553b8eeff249496ce4d9e474f7bMD57Carta-Comprovante_Camila_Marques_de_Araújo.pdf.txtCarta-Comprovante_Camila_Marques_de_Araújo.pdf.txtExtracted texttext/plain1520https://repositorio.ufscar.br/bitstream/ufscar/14651/9/Carta-Comprovante_Camila_Marques_de_Ara%c3%bajo.pdf.txt3b022f2f9422f590dcda51f88234bcc5MD59THUMBNAILDissertação_Camila_Marques_de_Araújo_2021_UFSCar.pdf.jpgDissertação_Camila_Marques_de_Araújo_2021_UFSCar.pdf.jpgIM Thumbnailimage/jpeg5624https://repositorio.ufscar.br/bitstream/ufscar/14651/8/Disserta%c3%a7%c3%a3o_Camila_Marques_de_Ara%c3%bajo_2021_UFSCar.pdf.jpgd78da0466d76678e1edcca8c1f75f99eMD58Carta-Comprovante_Camila_Marques_de_Araújo.pdf.jpgCarta-Comprovante_Camila_Marques_de_Araújo.pdf.jpgIM Thumbnailimage/jpeg7979https://repositorio.ufscar.br/bitstream/ufscar/14651/10/Carta-Comprovante_Camila_Marques_de_Ara%c3%bajo.pdf.jpga7ad49e308b3fcf0a1170f7d591a799eMD510ufscar/146512023-09-18 18:32:13.591oai:repositorio.ufscar.br:ufscar/14651Repositório InstitucionalPUBhttps://repositorio.ufscar.br/oai/requestopendoar:43222023-09-18T18:32:13Repositório Institucional da UFSCAR - Universidade Federal de São Carlos (UFSCAR)false
dc.title.por.fl_str_mv Dual energy X-Ray absorptiometry: desenvolvimento, validação e reprodutibilidade de recomendações técnicas para osteoartrite de ratos
dc.title.alternative.eng.fl_str_mv Energy X-Ray Absorptiometry: development, validation and reproducibility of technical recommendations for rat with osteoarthritis
title Dual energy X-Ray absorptiometry: desenvolvimento, validação e reprodutibilidade de recomendações técnicas para osteoartrite de ratos
spellingShingle Dual energy X-Ray absorptiometry: desenvolvimento, validação e reprodutibilidade de recomendações técnicas para osteoartrite de ratos
Araújo, Camila Marques de
Osteoartrite
Absorciometria de raios x de dupla energia
região de interesse,
Validação
Osteoarthritis
Dual energy X-ray absorptiometry
Region of interest
Validation
CIENCIAS BIOLOGICAS
title_short Dual energy X-Ray absorptiometry: desenvolvimento, validação e reprodutibilidade de recomendações técnicas para osteoartrite de ratos
title_full Dual energy X-Ray absorptiometry: desenvolvimento, validação e reprodutibilidade de recomendações técnicas para osteoartrite de ratos
title_fullStr Dual energy X-Ray absorptiometry: desenvolvimento, validação e reprodutibilidade de recomendações técnicas para osteoartrite de ratos
title_full_unstemmed Dual energy X-Ray absorptiometry: desenvolvimento, validação e reprodutibilidade de recomendações técnicas para osteoartrite de ratos
title_sort Dual energy X-Ray absorptiometry: desenvolvimento, validação e reprodutibilidade de recomendações técnicas para osteoartrite de ratos
author Araújo, Camila Marques de
author_facet Araújo, Camila Marques de
author_role author
dc.contributor.authorlattes.por.fl_str_mv http://lattes.cnpq.br/9439699688134971
dc.contributor.author.fl_str_mv Araújo, Camila Marques de
dc.contributor.advisor1.fl_str_mv Vasilceac, Fernando Augusto
dc.contributor.advisor1Lattes.fl_str_mv http://lattes.cnpq.br/1220838672192063
dc.contributor.authorID.fl_str_mv 7f9e0bea-cf46-461c-869c-26b5e1f6afe2
contributor_str_mv Vasilceac, Fernando Augusto
dc.subject.por.fl_str_mv Osteoartrite
Absorciometria de raios x de dupla energia
região de interesse,
Validação
topic Osteoartrite
Absorciometria de raios x de dupla energia
região de interesse,
Validação
Osteoarthritis
Dual energy X-ray absorptiometry
Region of interest
Validation
CIENCIAS BIOLOGICAS
dc.subject.eng.fl_str_mv Osteoarthritis
Dual energy X-ray absorptiometry
Region of interest
Validation
dc.subject.cnpq.fl_str_mv CIENCIAS BIOLOGICAS
description Objective: The aim of the present study is to develop, validate and make reproducible standardized anatomical regions of interest for bone mineral density (BMD) and bone mineral content (BMO) of rat knee at different times of osteoarthritis (OA) by formulating a guide to recommendations techniques for using dual energy X-ray absorptiometry (DXA). Methodology: 7 male winstar rats were used, divided into 2 groups entitled Osteoarthritis (OA) (n=6) and Test (T) (N=1). The OA group underwent transection of the anterior cruciate ligament for OA induction in the 14th week. The animals were anesthetized and scanned by DXA at the 14th, 19th and 24th weeks. After the scan, all images of the animals were analyzed using the software in specific and high-resolution small animal mode (resolution: 311 μm²) and anatomical regions of interest were made in the bones often associated with OA of the knee, femur and tibia. they were named Distal Femur and Proximal Tibia. In sequence, the technical recommendations guide was developed, validated and made reproducible, with norms and standardizations of the techniques for using the DXA, containing specific guidelines for the pre and post-test and preparation of regions of interest. The evaluators were divided into two groups with 2 members each, the evaluators were classified as experienced and inexperienced. Training was carried out to perform the positioning of the animal and selection of regions of interest for experienced and inexperienced evaluators. The evaluators carried out the proposed activities following the new recommendation guide made without any interference from the researcher using the group T mouse. Results: The validations of the regions of interest together with the formulation of technical recommendations formulated a valid and reliable basis for evaluating the BMD and CMO at different times of knee OA. Conclusion: The uses of the validated regions of interest and the recommendations guide make analyzes objective and less biased, increasing the efficiency of research standardization.
publishDate 2021
dc.date.accessioned.fl_str_mv 2021-07-22T12:24:51Z
dc.date.available.fl_str_mv 2021-07-22T12:24:51Z
dc.date.issued.fl_str_mv 2021-05-28
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
dc.type.driver.fl_str_mv info:eu-repo/semantics/masterThesis
format masterThesis
status_str publishedVersion
dc.identifier.citation.fl_str_mv ARAÚJO, Camila Marques de. Dual energy X-Ray absorptiometry: desenvolvimento, validação e reprodutibilidade de recomendações técnicas para osteoartrite de ratos. 2021. Dissertação (Mestrado em Gerontologia) – Universidade Federal de São Carlos, São Carlos, 2021. Disponível em: https://repositorio.ufscar.br/handle/ufscar/14651.
dc.identifier.uri.fl_str_mv https://repositorio.ufscar.br/handle/ufscar/14651
identifier_str_mv ARAÚJO, Camila Marques de. Dual energy X-Ray absorptiometry: desenvolvimento, validação e reprodutibilidade de recomendações técnicas para osteoartrite de ratos. 2021. Dissertação (Mestrado em Gerontologia) – Universidade Federal de São Carlos, São Carlos, 2021. Disponível em: https://repositorio.ufscar.br/handle/ufscar/14651.
url https://repositorio.ufscar.br/handle/ufscar/14651
dc.language.iso.fl_str_mv por
language por
dc.relation.confidence.fl_str_mv 600
dc.relation.authority.fl_str_mv ff051788-91c5-4a09-9867-9b3aac7fdef1
dc.rights.driver.fl_str_mv Attribution-NonCommercial-NoDerivs 3.0 Brazil
http://creativecommons.org/licenses/by-nc-nd/3.0/br/
info:eu-repo/semantics/openAccess
rights_invalid_str_mv Attribution-NonCommercial-NoDerivs 3.0 Brazil
http://creativecommons.org/licenses/by-nc-nd/3.0/br/
eu_rights_str_mv openAccess
dc.publisher.none.fl_str_mv Universidade Federal de São Carlos
Câmpus São Carlos
dc.publisher.program.fl_str_mv Programa de Pós-Graduação em Gerontologia - PPGGero
dc.publisher.initials.fl_str_mv UFSCar
publisher.none.fl_str_mv Universidade Federal de São Carlos
Câmpus São Carlos
dc.source.none.fl_str_mv reponame:Repositório Institucional da UFSCAR
instname:Universidade Federal de São Carlos (UFSCAR)
instacron:UFSCAR
instname_str Universidade Federal de São Carlos (UFSCAR)
instacron_str UFSCAR
institution UFSCAR
reponame_str Repositório Institucional da UFSCAR
collection Repositório Institucional da UFSCAR
bitstream.url.fl_str_mv https://repositorio.ufscar.br/bitstream/ufscar/14651/4/Disserta%c3%a7%c3%a3o_Camila_Marques_de_Ara%c3%bajo_2021_UFSCar.pdf
https://repositorio.ufscar.br/bitstream/ufscar/14651/5/Carta-Comprovante_Camila_Marques_de_Ara%c3%bajo.pdf
https://repositorio.ufscar.br/bitstream/ufscar/14651/6/license_rdf
https://repositorio.ufscar.br/bitstream/ufscar/14651/7/Disserta%c3%a7%c3%a3o_Camila_Marques_de_Ara%c3%bajo_2021_UFSCar.pdf.txt
https://repositorio.ufscar.br/bitstream/ufscar/14651/9/Carta-Comprovante_Camila_Marques_de_Ara%c3%bajo.pdf.txt
https://repositorio.ufscar.br/bitstream/ufscar/14651/8/Disserta%c3%a7%c3%a3o_Camila_Marques_de_Ara%c3%bajo_2021_UFSCar.pdf.jpg
https://repositorio.ufscar.br/bitstream/ufscar/14651/10/Carta-Comprovante_Camila_Marques_de_Ara%c3%bajo.pdf.jpg
bitstream.checksum.fl_str_mv 13b0d4c431d564cc05e4ed816d62eb84
42d44487f54b53aebcf4581e8951fd36
e39d27027a6cc9cb039ad269a5db8e34
97f95553b8eeff249496ce4d9e474f7b
3b022f2f9422f590dcda51f88234bcc5
d78da0466d76678e1edcca8c1f75f99e
a7ad49e308b3fcf0a1170f7d591a799e
bitstream.checksumAlgorithm.fl_str_mv MD5
MD5
MD5
MD5
MD5
MD5
MD5
repository.name.fl_str_mv Repositório Institucional da UFSCAR - Universidade Federal de São Carlos (UFSCAR)
repository.mail.fl_str_mv
_version_ 1813715634065768448