Sistema PET/MR híbrido: aplicação para imageamento in vivo em ambiente de máxima biocontenção
Autor(a) principal: | |
---|---|
Data de Publicação: | 2022 |
Tipo de documento: | Trabalho de conclusão de curso |
Idioma: | por |
Título da fonte: | Repositório Institucional da UFSCAR |
Texto Completo: | https://repositorio.ufscar.br/handle/ufscar/16035 |
Resumo: | The imaging of living organisms, in its different techniques and applications, corresponds to the least invasive and most pragmatic way to analyze the development of infectious processes, in addition to its many other applications for biological research. Specifically with regard to in vivo investigations of infections by highly pathogenic microorganisms, the use of positron emission tomography and magnetic resonance imaging allow the anatomically longitudinal assessment of the infectious course, that is, without the need to resort to the traditional method of euthanasia in series of animals under study. Considering these premises, the CNPEM (National Center for Research in Energy and Materials) was the organization chosen to house the first national maximum containment laboratory, promoting the innovative association of beamlines with maximum biocontainment laboratories. Thus, enabling the analysis of animal models of infections at higher resolutions both at the cellular and morphological levels. The present project proposes to complement the work to be carried out on the beamlines, saving their precious operating time and allowing an additional layer of data to be added to the research to be carried out in biosafety laboratories. Thus, the scope of the project is the broad technical and technological understanding, specification, infrastructure design, acquisition, and biocontained installation of a commercial PET/MR equipment to be initially allocated in a conventional laboratory environment and, later, to be relocated in the future Virology. This proposal aims to establish a coexistence of the CNPEM team with the experience of in vivo imaging, enabling the realization of experiments that guide the future decisions of the configurations of the biocontained installations, in addition to allowing the development of the engineering team regarding the technologies of positron emission tomography, magnetic resonance, signal detection and image processing. |
id |
SCAR_e712089c7e07c20eb205af0a054a4077 |
---|---|
oai_identifier_str |
oai:repositorio.ufscar.br:ufscar/16035 |
network_acronym_str |
SCAR |
network_name_str |
Repositório Institucional da UFSCAR |
repository_id_str |
4322 |
spelling |
Brito, Marisa Fonseca de AlmeidaFerri, Fábio Aparecidohttp://lattes.cnpq.br/8314629367795792Neuenschwander, Regis Terenzihttp://lattes.cnpq.br/3985101799853723fb39e633-ab95-4d3e-bc6d-978d9aa76d4d2022-05-04T23:59:38Z2022-05-04T23:59:38Z2022-04-18BRITO, Marisa Fonseca de Almeida. Sistema PET/MR híbrido: aplicação para imageamento in vivo em ambiente de máxima biocontenção. 2022. Trabalho de Conclusão de Curso (Graduação em Engenharia Física) – Universidade Federal de São Carlos, São Carlos, 2022. Disponível em: https://repositorio.ufscar.br/handle/ufscar/16035.https://repositorio.ufscar.br/handle/ufscar/16035The imaging of living organisms, in its different techniques and applications, corresponds to the least invasive and most pragmatic way to analyze the development of infectious processes, in addition to its many other applications for biological research. Specifically with regard to in vivo investigations of infections by highly pathogenic microorganisms, the use of positron emission tomography and magnetic resonance imaging allow the anatomically longitudinal assessment of the infectious course, that is, without the need to resort to the traditional method of euthanasia in series of animals under study. Considering these premises, the CNPEM (National Center for Research in Energy and Materials) was the organization chosen to house the first national maximum containment laboratory, promoting the innovative association of beamlines with maximum biocontainment laboratories. Thus, enabling the analysis of animal models of infections at higher resolutions both at the cellular and morphological levels. The present project proposes to complement the work to be carried out on the beamlines, saving their precious operating time and allowing an additional layer of data to be added to the research to be carried out in biosafety laboratories. Thus, the scope of the project is the broad technical and technological understanding, specification, infrastructure design, acquisition, and biocontained installation of a commercial PET/MR equipment to be initially allocated in a conventional laboratory environment and, later, to be relocated in the future Virology. This proposal aims to establish a coexistence of the CNPEM team with the experience of in vivo imaging, enabling the realization of experiments that guide the future decisions of the configurations of the biocontained installations, in addition to allowing the development of the engineering team regarding the technologies of positron emission tomography, magnetic resonance, signal detection and image processing.O imageamento de organismos vivos, em suas distintas técnicas e aplicações, corresponde à maneira menos invasiva e mais pragmática para análise de desenvolvimento de processos infecciosos, além de suas muitas outras aplicações para pesquisa biológica. Especificamente quanto às pesquisas in vivo de infecções por microrganismos de alta patogenicidade, o uso da tomografia por emissão de pósitrons e ressonância magnética permitem avaliar o curso infeccioso anatomicamente de forma longitudinal, ou seja, sem a necessidade de se recorrer ao tradicional método da eutanásia em série dos animais em estudo. Considerando essas premissas, o CNPEM (Centro Nacional de Pesquisa em Energia e Materiais) foi a organização escolhida para abrigar o primeiro laboratório de máxima contenção nacional, promovendo a associação inovadora das linhas de luz com os laboratórios de biocontenção máxima. Assim, possibilitando a análise de modelos animais de infecções em resoluções superiores tanto em nível celular quanto em nível morfológico. O presente projeto propõe complementar o trabalho a ser realizado nas linhas de luz, economizando o seu tempo precioso de funcionamento e permitindo adicionar uma camada suplementar de dados para as pesquisas a serem desenvolvidas nos laboratórios de biossegurança. Assim, o escopo do projeto é a ampla compreensão técnica e tecnológica, especificação, projeto da infraestrutura, aquisição, e instalação biocontida de um equipamento PET/MR comercial a ser inicialmente alocado em ambiente laboratorial convencional e, posteriormente, ser realocado no futuro Centro de Virologia. Tal proposta tem o intuito de estabelecer um convívio da equipe do CNPEM com a experiência de imageamento in vivo, possibilitando a realização de experimentações que orientem as futuras decisões das configurações das instalações biocontidas, além de permitir o desenvolvimento da equipe de engenharia quanto às tecnologias de tomografia de emissão de pósitrons, ressonância magnética, detecção de sinais e processamento de imagem.Não recebi financiamentoporUniversidade Federal de São CarlosCâmpus São CarlosEngenharia Física - EFiUFSCarAttribution-NonCommercial-NoDerivs 3.0 Brazilhttp://creativecommons.org/licenses/by-nc-nd/3.0/br/info:eu-repo/semantics/openAccessRessonância magnéticaTomografia por emissão de pósitronsBiossegurançaCIENCIAS EXATAS E DA TERRA::FISICASistema PET/MR híbrido: aplicação para imageamento in vivo em ambiente de máxima biocontençãoHybrid PET/MR system: application for in vivo imaging in a maximum biocontainment environmentinfo:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/bachelorThesis600600a174c3a0-937b-413d-a39a-269c5888fafbreponame:Repositório Institucional da UFSCARinstname:Universidade Federal de São Carlos (UFSCAR)instacron:UFSCARORIGINALTFC_Marisa_repositório.pdfTFC_Marisa_repositório.pdfapplication/pdf6403643https://repositorio.ufscar.br/bitstream/ufscar/16035/1/TFC_Marisa_reposit%c3%b3rio.pdfaf0499817efb975e7c441f59bcf0321aMD51CC-LICENSElicense_rdflicense_rdfapplication/rdf+xml; charset=utf-8811https://repositorio.ufscar.br/bitstream/ufscar/16035/2/license_rdfe39d27027a6cc9cb039ad269a5db8e34MD52TEXTTFC_Marisa_repositório.pdf.txtTFC_Marisa_repositório.pdf.txtExtracted texttext/plain99307https://repositorio.ufscar.br/bitstream/ufscar/16035/3/TFC_Marisa_reposit%c3%b3rio.pdf.txt74ccf03843a3e06a2a88ee53d9f1c26eMD53THUMBNAILTFC_Marisa_repositório.pdf.jpgTFC_Marisa_repositório.pdf.jpgIM Thumbnailimage/jpeg4092https://repositorio.ufscar.br/bitstream/ufscar/16035/4/TFC_Marisa_reposit%c3%b3rio.pdf.jpg7664251102a96bec9c348cad90a660afMD54ufscar/160352023-09-18 18:32:27.215oai:repositorio.ufscar.br:ufscar/16035Repositório InstitucionalPUBhttps://repositorio.ufscar.br/oai/requestopendoar:43222023-09-18T18:32:27Repositório Institucional da UFSCAR - Universidade Federal de São Carlos (UFSCAR)false |
dc.title.por.fl_str_mv |
Sistema PET/MR híbrido: aplicação para imageamento in vivo em ambiente de máxima biocontenção |
dc.title.alternative.eng.fl_str_mv |
Hybrid PET/MR system: application for in vivo imaging in a maximum biocontainment environment |
title |
Sistema PET/MR híbrido: aplicação para imageamento in vivo em ambiente de máxima biocontenção |
spellingShingle |
Sistema PET/MR híbrido: aplicação para imageamento in vivo em ambiente de máxima biocontenção Brito, Marisa Fonseca de Almeida Ressonância magnética Tomografia por emissão de pósitrons Biossegurança CIENCIAS EXATAS E DA TERRA::FISICA |
title_short |
Sistema PET/MR híbrido: aplicação para imageamento in vivo em ambiente de máxima biocontenção |
title_full |
Sistema PET/MR híbrido: aplicação para imageamento in vivo em ambiente de máxima biocontenção |
title_fullStr |
Sistema PET/MR híbrido: aplicação para imageamento in vivo em ambiente de máxima biocontenção |
title_full_unstemmed |
Sistema PET/MR híbrido: aplicação para imageamento in vivo em ambiente de máxima biocontenção |
title_sort |
Sistema PET/MR híbrido: aplicação para imageamento in vivo em ambiente de máxima biocontenção |
author |
Brito, Marisa Fonseca de Almeida |
author_facet |
Brito, Marisa Fonseca de Almeida |
author_role |
author |
dc.contributor.author.fl_str_mv |
Brito, Marisa Fonseca de Almeida |
dc.contributor.advisor1.fl_str_mv |
Ferri, Fábio Aparecido |
dc.contributor.advisor1Lattes.fl_str_mv |
http://lattes.cnpq.br/8314629367795792 |
dc.contributor.advisor-co1.fl_str_mv |
Neuenschwander, Regis Terenzi |
dc.contributor.advisor-co1Lattes.fl_str_mv |
http://lattes.cnpq.br/3985101799853723 |
dc.contributor.authorID.fl_str_mv |
fb39e633-ab95-4d3e-bc6d-978d9aa76d4d |
contributor_str_mv |
Ferri, Fábio Aparecido Neuenschwander, Regis Terenzi |
dc.subject.por.fl_str_mv |
Ressonância magnética Tomografia por emissão de pósitrons Biossegurança |
topic |
Ressonância magnética Tomografia por emissão de pósitrons Biossegurança CIENCIAS EXATAS E DA TERRA::FISICA |
dc.subject.cnpq.fl_str_mv |
CIENCIAS EXATAS E DA TERRA::FISICA |
description |
The imaging of living organisms, in its different techniques and applications, corresponds to the least invasive and most pragmatic way to analyze the development of infectious processes, in addition to its many other applications for biological research. Specifically with regard to in vivo investigations of infections by highly pathogenic microorganisms, the use of positron emission tomography and magnetic resonance imaging allow the anatomically longitudinal assessment of the infectious course, that is, without the need to resort to the traditional method of euthanasia in series of animals under study. Considering these premises, the CNPEM (National Center for Research in Energy and Materials) was the organization chosen to house the first national maximum containment laboratory, promoting the innovative association of beamlines with maximum biocontainment laboratories. Thus, enabling the analysis of animal models of infections at higher resolutions both at the cellular and morphological levels. The present project proposes to complement the work to be carried out on the beamlines, saving their precious operating time and allowing an additional layer of data to be added to the research to be carried out in biosafety laboratories. Thus, the scope of the project is the broad technical and technological understanding, specification, infrastructure design, acquisition, and biocontained installation of a commercial PET/MR equipment to be initially allocated in a conventional laboratory environment and, later, to be relocated in the future Virology. This proposal aims to establish a coexistence of the CNPEM team with the experience of in vivo imaging, enabling the realization of experiments that guide the future decisions of the configurations of the biocontained installations, in addition to allowing the development of the engineering team regarding the technologies of positron emission tomography, magnetic resonance, signal detection and image processing. |
publishDate |
2022 |
dc.date.accessioned.fl_str_mv |
2022-05-04T23:59:38Z |
dc.date.available.fl_str_mv |
2022-05-04T23:59:38Z |
dc.date.issued.fl_str_mv |
2022-04-18 |
dc.type.status.fl_str_mv |
info:eu-repo/semantics/publishedVersion |
dc.type.driver.fl_str_mv |
info:eu-repo/semantics/bachelorThesis |
format |
bachelorThesis |
status_str |
publishedVersion |
dc.identifier.citation.fl_str_mv |
BRITO, Marisa Fonseca de Almeida. Sistema PET/MR híbrido: aplicação para imageamento in vivo em ambiente de máxima biocontenção. 2022. Trabalho de Conclusão de Curso (Graduação em Engenharia Física) – Universidade Federal de São Carlos, São Carlos, 2022. Disponível em: https://repositorio.ufscar.br/handle/ufscar/16035. |
dc.identifier.uri.fl_str_mv |
https://repositorio.ufscar.br/handle/ufscar/16035 |
identifier_str_mv |
BRITO, Marisa Fonseca de Almeida. Sistema PET/MR híbrido: aplicação para imageamento in vivo em ambiente de máxima biocontenção. 2022. Trabalho de Conclusão de Curso (Graduação em Engenharia Física) – Universidade Federal de São Carlos, São Carlos, 2022. Disponível em: https://repositorio.ufscar.br/handle/ufscar/16035. |
url |
https://repositorio.ufscar.br/handle/ufscar/16035 |
dc.language.iso.fl_str_mv |
por |
language |
por |
dc.relation.confidence.fl_str_mv |
600 600 |
dc.relation.authority.fl_str_mv |
a174c3a0-937b-413d-a39a-269c5888fafb |
dc.rights.driver.fl_str_mv |
Attribution-NonCommercial-NoDerivs 3.0 Brazil http://creativecommons.org/licenses/by-nc-nd/3.0/br/ info:eu-repo/semantics/openAccess |
rights_invalid_str_mv |
Attribution-NonCommercial-NoDerivs 3.0 Brazil http://creativecommons.org/licenses/by-nc-nd/3.0/br/ |
eu_rights_str_mv |
openAccess |
dc.publisher.none.fl_str_mv |
Universidade Federal de São Carlos Câmpus São Carlos Engenharia Física - EFi |
dc.publisher.initials.fl_str_mv |
UFSCar |
publisher.none.fl_str_mv |
Universidade Federal de São Carlos Câmpus São Carlos Engenharia Física - EFi |
dc.source.none.fl_str_mv |
reponame:Repositório Institucional da UFSCAR instname:Universidade Federal de São Carlos (UFSCAR) instacron:UFSCAR |
instname_str |
Universidade Federal de São Carlos (UFSCAR) |
instacron_str |
UFSCAR |
institution |
UFSCAR |
reponame_str |
Repositório Institucional da UFSCAR |
collection |
Repositório Institucional da UFSCAR |
bitstream.url.fl_str_mv |
https://repositorio.ufscar.br/bitstream/ufscar/16035/1/TFC_Marisa_reposit%c3%b3rio.pdf https://repositorio.ufscar.br/bitstream/ufscar/16035/2/license_rdf https://repositorio.ufscar.br/bitstream/ufscar/16035/3/TFC_Marisa_reposit%c3%b3rio.pdf.txt https://repositorio.ufscar.br/bitstream/ufscar/16035/4/TFC_Marisa_reposit%c3%b3rio.pdf.jpg |
bitstream.checksum.fl_str_mv |
af0499817efb975e7c441f59bcf0321a e39d27027a6cc9cb039ad269a5db8e34 74ccf03843a3e06a2a88ee53d9f1c26e 7664251102a96bec9c348cad90a660af |
bitstream.checksumAlgorithm.fl_str_mv |
MD5 MD5 MD5 MD5 |
repository.name.fl_str_mv |
Repositório Institucional da UFSCAR - Universidade Federal de São Carlos (UFSCAR) |
repository.mail.fl_str_mv |
|
_version_ |
1813715647275728896 |