Avaliação da força de preensão manual: revisão sistemática

Detalhes bibliográficos
Autor(a) principal: Basso, Fernanda Manenti
Data de Publicação: 2022
Tipo de documento: Dissertação
Idioma: por
Título da fonte: Repositório Institucional da UFSCAR
Texto Completo: https://repositorio.ufscar.br/handle/ufscar/16770
Resumo: Introduction: Demonstrate clinical testing and verify essential assessment tools for physical therapists. Hand grip strength (HGS) is a rapid method of measuring upper grip strength and is also used to assess global muscle strength. HGS is measured using dynamometers, the Jamar® hydraulic dynamometer being the most used and considered by the American Society of Hand Therapists (ASHT) as the “gold standard” for evaluation. Objective: To carry out a systematic review to identify gaps in the HGS assessment performed by portable means of manual dynamometers and interpretation of their results. Method: Studies published up to January 1981 were published from January 2021: they were based on a dynamometer of the keywords (Handgrip OR hand strength OR muscle strength OR dynamometer AND test hand Strength) in the databases: Pubmed, Embase Web of Science. Studies in Spanish and English that evaluated HGS were included. Results: 12,371 articles were identified, of which 252 were duplicates, of which 10,763 were excluded after reading the title and abstract, resulting in 1356 articles. Of these, 373 were excluded for not having access to the content. A total of 983 articles were selected for full reading, from which those that did not meet the eligibility criteria were excluded, resulting in 46 articles in the review. The age group ranged from 4 to 60 years in 69.56% of the articles and 60 years or over in 30.43% of the articles included. As for the dynamometer brand, 56.52% used the Jamar® brand and 43.47% used other dynamometer brands. The results indicate that there is great variability in the methods used in the evaluation of HGS and in the interpretation of its results, with 45.65% of the articles using HGS in order to assess the upper limbs, 10.86% sarcopenia; 2.17% nutritional status and 10.86% overall muscle strength. Conclusion: Despite the ASHT recommendations, there are still studies that do not follow them, which can generate bias in the performance of the test and in the interpretation of the results obtained, making it difficult to compare studies.
id SCAR_f46d0b99a135f809ec03500f166f5abb
oai_identifier_str oai:repositorio.ufscar.br:ufscar/16770
network_acronym_str SCAR
network_name_str Repositório Institucional da UFSCAR
repository_id_str 4322
spelling Basso, Fernanda ManentiJamami, Mauríciohttp://lattes.cnpq.br/4274129560250050Gonzaga, Luana Aparecida Vieirahttp://lattes.cnpq.br/0722245980119266http://lattes.cnpq.br/74109749217593979551988b-aa54-4d30-a08a-d1cf679a1d0e2022-10-03T14:08:56Z2022-10-03T14:08:56Z2022-02-23BASSO, Fernanda Manenti. Avaliação da força de preensão manual: revisão sistemática. 2022. Dissertação (Mestrado em Fisioterapia) – Universidade Federal de São Carlos, São Carlos, 2022. Disponível em: https://repositorio.ufscar.br/handle/ufscar/16770.https://repositorio.ufscar.br/handle/ufscar/16770Introduction: Demonstrate clinical testing and verify essential assessment tools for physical therapists. Hand grip strength (HGS) is a rapid method of measuring upper grip strength and is also used to assess global muscle strength. HGS is measured using dynamometers, the Jamar® hydraulic dynamometer being the most used and considered by the American Society of Hand Therapists (ASHT) as the “gold standard” for evaluation. Objective: To carry out a systematic review to identify gaps in the HGS assessment performed by portable means of manual dynamometers and interpretation of their results. Method: Studies published up to January 1981 were published from January 2021: they were based on a dynamometer of the keywords (Handgrip OR hand strength OR muscle strength OR dynamometer AND test hand Strength) in the databases: Pubmed, Embase Web of Science. Studies in Spanish and English that evaluated HGS were included. Results: 12,371 articles were identified, of which 252 were duplicates, of which 10,763 were excluded after reading the title and abstract, resulting in 1356 articles. Of these, 373 were excluded for not having access to the content. A total of 983 articles were selected for full reading, from which those that did not meet the eligibility criteria were excluded, resulting in 46 articles in the review. The age group ranged from 4 to 60 years in 69.56% of the articles and 60 years or over in 30.43% of the articles included. As for the dynamometer brand, 56.52% used the Jamar® brand and 43.47% used other dynamometer brands. The results indicate that there is great variability in the methods used in the evaluation of HGS and in the interpretation of its results, with 45.65% of the articles using HGS in order to assess the upper limbs, 10.86% sarcopenia; 2.17% nutritional status and 10.86% overall muscle strength. Conclusion: Despite the ASHT recommendations, there are still studies that do not follow them, which can generate bias in the performance of the test and in the interpretation of the results obtained, making it difficult to compare studies.Introdução: Demonstrar a efetividade de testes clínicos e comprovar a validade de instrumentos de avaliação é essencial para fisioterapeutas. A força de preensão manual (FPM) é um método rápido de mensuração da força de membros superiores e também é usada para avaliação da força muscular global. A FPM é mensurada por meio de dinamômetros, sendo o dinamômetro hidráulico Jamar®, o mais utilizado e considerado pela Sociedade Americana de Terapeutas da Mão (SATM) como “padrão-ouro” para avaliação. Objetivo: Realizar uma revisão sistemática para identificar as lacunas existentes na padronização da avaliação da FPM realizada por meio de dinamômetros manuais portáteis e a interpretação dos seus resultados. Método: Estudos publicados de janeiro de 1981 até janeiro de 2021 foram localizados a partir das palavras-chave: (Handgrip OR hand strength OR muscle strength dynamometer OR dynamometry AND test hand strength) nas seguintes bases de dados: Pubmed, Embase, Web of Science.Foram incluídos estudos na língua portuguesa, espanhola e inglesa, que avaliaram a FPM. Resultados: Foram identificados 12.371 artigos, dos quais 252 eram duplicatas, as quais foram excluídas 10.763, foram excluídos após leitura de título e resumo, resultando em 1356 artigos. Destes, 373 foram excluídos por não acesso ao conteúdo. Foram selecionados 983 artigos para leitura na íntegra, dos quais foram excluídos os que não atenderam os critérios de elegibilidade, resultando em 46 artigos na revisão. A faixa etária variou de 4 a 60 anos em 69,56% dos artigos e 60 anos ou mais em 30,43% dos artigos incluídos. Quanto a marca do dinamômetro 56,52% utilizaram a marca Jamar® e 43,47% outras marcas de dinamômetro. Os resultados indicam que existe grande variabilidade nos métodos empregados na avaliação da FPM e na interpretação dos seus resultados, sendo que 45,65% dos artigos utilizaram a FPM com a finalidade de avaliar MMSS, 10,86% sarcopenia; 2,17% estado nutricional e 10,86% força muscular global. Conclusão: Mesmo diante das recomendações da SATM ainda existem estudos que não as seguem, podendo gerar viés na realização do teste e na interpretação dos resultados obtidos, dificultando a comparação das pesquisas.Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)88887.505771/2020-00porUniversidade Federal de São CarlosCâmpus São CarlosPrograma de Pós-Graduação em Fisioterapia - PPGFtUFSCarAttribution-NonCommercial-NoDerivs 3.0 Brazilhttp://creativecommons.org/licenses/by-nc-nd/3.0/br/info:eu-repo/semantics/openAccessAperto da mãoForça da mãoDinamômetro de força muscularDinamometriaHandshakeHand strengthMuscle strength dynamometerDynamometryCIENCIAS DA SAUDE::FISIOTERAPIA E TERAPIA OCUPACIONALAvaliação da força de preensão manual: revisão sistemáticaHandgrip strength assessment: systematic reviewinfo:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/masterThesis600600bd0cbb98-978e-41d4-acd9-a1acaba0dedareponame:Repositório Institucional da UFSCARinstname:Universidade Federal de São Carlos (UFSCAR)instacron:UFSCARCC-LICENSElicense_rdflicense_rdfapplication/rdf+xml; charset=utf-8811https://repositorio.ufscar.br/bitstream/ufscar/16770/4/license_rdfe39d27027a6cc9cb039ad269a5db8e34MD54ORIGINALDissertacao_Final_Fernanda_Basso.pdfDissertacao_Final_Fernanda_Basso.pdf"Dissertação de Mestrado"application/pdf1015759https://repositorio.ufscar.br/bitstream/ufscar/16770/1/Dissertacao_Final_Fernanda_Basso.pdfc2863d9daa13e336ee9b39e07b3208a1MD51Carta-comprovante-da-versão-final-de-teses-e-dissertações_FMB.pdfCarta-comprovante-da-versão-final-de-teses-e-dissertações_FMB.pdf"Carta Comprovante"application/pdf126716https://repositorio.ufscar.br/bitstream/ufscar/16770/3/Carta-comprovante-da-vers%c3%a3o-final-de-teses-e-disserta%c3%a7%c3%b5es_FMB.pdf0aca01f38a217aff31add7bf5a89568aMD53TEXTDissertacao_Final_Fernanda_Basso.pdf.txtDissertacao_Final_Fernanda_Basso.pdf.txtExtracted texttext/plain88481https://repositorio.ufscar.br/bitstream/ufscar/16770/5/Dissertacao_Final_Fernanda_Basso.pdf.txt4239a772ec7d1b45a1e3bdd272a58236MD55Carta-comprovante-da-versão-final-de-teses-e-dissertações_FMB.pdf.txtCarta-comprovante-da-versão-final-de-teses-e-dissertações_FMB.pdf.txtExtracted texttext/plain1352https://repositorio.ufscar.br/bitstream/ufscar/16770/7/Carta-comprovante-da-vers%c3%a3o-final-de-teses-e-disserta%c3%a7%c3%b5es_FMB.pdf.txt6eb5d876b986491b23bd0582b2b6bb64MD57THUMBNAILDissertacao_Final_Fernanda_Basso.pdf.jpgDissertacao_Final_Fernanda_Basso.pdf.jpgIM Thumbnailimage/jpeg5478https://repositorio.ufscar.br/bitstream/ufscar/16770/6/Dissertacao_Final_Fernanda_Basso.pdf.jpg958c5ccb7563deae689fd0098a68a136MD56Carta-comprovante-da-versão-final-de-teses-e-dissertações_FMB.pdf.jpgCarta-comprovante-da-versão-final-de-teses-e-dissertações_FMB.pdf.jpgIM Thumbnailimage/jpeg14998https://repositorio.ufscar.br/bitstream/ufscar/16770/8/Carta-comprovante-da-vers%c3%a3o-final-de-teses-e-disserta%c3%a7%c3%b5es_FMB.pdf.jpgdfa4e48490519e315a54ade5280ca09dMD58ufscar/167702023-09-18 18:32:29.634oai:repositorio.ufscar.br:ufscar/16770Repositório InstitucionalPUBhttps://repositorio.ufscar.br/oai/requestopendoar:43222023-09-18T18:32:29Repositório Institucional da UFSCAR - Universidade Federal de São Carlos (UFSCAR)false
dc.title.por.fl_str_mv Avaliação da força de preensão manual: revisão sistemática
dc.title.alternative.eng.fl_str_mv Handgrip strength assessment: systematic review
title Avaliação da força de preensão manual: revisão sistemática
spellingShingle Avaliação da força de preensão manual: revisão sistemática
Basso, Fernanda Manenti
Aperto da mão
Força da mão
Dinamômetro de força muscular
Dinamometria
Handshake
Hand strength
Muscle strength dynamometer
Dynamometry
CIENCIAS DA SAUDE::FISIOTERAPIA E TERAPIA OCUPACIONAL
title_short Avaliação da força de preensão manual: revisão sistemática
title_full Avaliação da força de preensão manual: revisão sistemática
title_fullStr Avaliação da força de preensão manual: revisão sistemática
title_full_unstemmed Avaliação da força de preensão manual: revisão sistemática
title_sort Avaliação da força de preensão manual: revisão sistemática
author Basso, Fernanda Manenti
author_facet Basso, Fernanda Manenti
author_role author
dc.contributor.authorlattes.por.fl_str_mv http://lattes.cnpq.br/7410974921759397
dc.contributor.author.fl_str_mv Basso, Fernanda Manenti
dc.contributor.advisor1.fl_str_mv Jamami, Maurício
dc.contributor.advisor1Lattes.fl_str_mv http://lattes.cnpq.br/4274129560250050
dc.contributor.advisor-co1.fl_str_mv Gonzaga, Luana Aparecida Vieira
dc.contributor.advisor-co1Lattes.fl_str_mv http://lattes.cnpq.br/0722245980119266
dc.contributor.authorID.fl_str_mv 9551988b-aa54-4d30-a08a-d1cf679a1d0e
contributor_str_mv Jamami, Maurício
Gonzaga, Luana Aparecida Vieira
dc.subject.por.fl_str_mv Aperto da mão
Força da mão
Dinamômetro de força muscular
Dinamometria
topic Aperto da mão
Força da mão
Dinamômetro de força muscular
Dinamometria
Handshake
Hand strength
Muscle strength dynamometer
Dynamometry
CIENCIAS DA SAUDE::FISIOTERAPIA E TERAPIA OCUPACIONAL
dc.subject.eng.fl_str_mv Handshake
Hand strength
Muscle strength dynamometer
Dynamometry
dc.subject.cnpq.fl_str_mv CIENCIAS DA SAUDE::FISIOTERAPIA E TERAPIA OCUPACIONAL
description Introduction: Demonstrate clinical testing and verify essential assessment tools for physical therapists. Hand grip strength (HGS) is a rapid method of measuring upper grip strength and is also used to assess global muscle strength. HGS is measured using dynamometers, the Jamar® hydraulic dynamometer being the most used and considered by the American Society of Hand Therapists (ASHT) as the “gold standard” for evaluation. Objective: To carry out a systematic review to identify gaps in the HGS assessment performed by portable means of manual dynamometers and interpretation of their results. Method: Studies published up to January 1981 were published from January 2021: they were based on a dynamometer of the keywords (Handgrip OR hand strength OR muscle strength OR dynamometer AND test hand Strength) in the databases: Pubmed, Embase Web of Science. Studies in Spanish and English that evaluated HGS were included. Results: 12,371 articles were identified, of which 252 were duplicates, of which 10,763 were excluded after reading the title and abstract, resulting in 1356 articles. Of these, 373 were excluded for not having access to the content. A total of 983 articles were selected for full reading, from which those that did not meet the eligibility criteria were excluded, resulting in 46 articles in the review. The age group ranged from 4 to 60 years in 69.56% of the articles and 60 years or over in 30.43% of the articles included. As for the dynamometer brand, 56.52% used the Jamar® brand and 43.47% used other dynamometer brands. The results indicate that there is great variability in the methods used in the evaluation of HGS and in the interpretation of its results, with 45.65% of the articles using HGS in order to assess the upper limbs, 10.86% sarcopenia; 2.17% nutritional status and 10.86% overall muscle strength. Conclusion: Despite the ASHT recommendations, there are still studies that do not follow them, which can generate bias in the performance of the test and in the interpretation of the results obtained, making it difficult to compare studies.
publishDate 2022
dc.date.accessioned.fl_str_mv 2022-10-03T14:08:56Z
dc.date.available.fl_str_mv 2022-10-03T14:08:56Z
dc.date.issued.fl_str_mv 2022-02-23
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
dc.type.driver.fl_str_mv info:eu-repo/semantics/masterThesis
format masterThesis
status_str publishedVersion
dc.identifier.citation.fl_str_mv BASSO, Fernanda Manenti. Avaliação da força de preensão manual: revisão sistemática. 2022. Dissertação (Mestrado em Fisioterapia) – Universidade Federal de São Carlos, São Carlos, 2022. Disponível em: https://repositorio.ufscar.br/handle/ufscar/16770.
dc.identifier.uri.fl_str_mv https://repositorio.ufscar.br/handle/ufscar/16770
identifier_str_mv BASSO, Fernanda Manenti. Avaliação da força de preensão manual: revisão sistemática. 2022. Dissertação (Mestrado em Fisioterapia) – Universidade Federal de São Carlos, São Carlos, 2022. Disponível em: https://repositorio.ufscar.br/handle/ufscar/16770.
url https://repositorio.ufscar.br/handle/ufscar/16770
dc.language.iso.fl_str_mv por
language por
dc.relation.confidence.fl_str_mv 600
600
dc.relation.authority.fl_str_mv bd0cbb98-978e-41d4-acd9-a1acaba0deda
dc.rights.driver.fl_str_mv Attribution-NonCommercial-NoDerivs 3.0 Brazil
http://creativecommons.org/licenses/by-nc-nd/3.0/br/
info:eu-repo/semantics/openAccess
rights_invalid_str_mv Attribution-NonCommercial-NoDerivs 3.0 Brazil
http://creativecommons.org/licenses/by-nc-nd/3.0/br/
eu_rights_str_mv openAccess
dc.publisher.none.fl_str_mv Universidade Federal de São Carlos
Câmpus São Carlos
dc.publisher.program.fl_str_mv Programa de Pós-Graduação em Fisioterapia - PPGFt
dc.publisher.initials.fl_str_mv UFSCar
publisher.none.fl_str_mv Universidade Federal de São Carlos
Câmpus São Carlos
dc.source.none.fl_str_mv reponame:Repositório Institucional da UFSCAR
instname:Universidade Federal de São Carlos (UFSCAR)
instacron:UFSCAR
instname_str Universidade Federal de São Carlos (UFSCAR)
instacron_str UFSCAR
institution UFSCAR
reponame_str Repositório Institucional da UFSCAR
collection Repositório Institucional da UFSCAR
bitstream.url.fl_str_mv https://repositorio.ufscar.br/bitstream/ufscar/16770/4/license_rdf
https://repositorio.ufscar.br/bitstream/ufscar/16770/1/Dissertacao_Final_Fernanda_Basso.pdf
https://repositorio.ufscar.br/bitstream/ufscar/16770/3/Carta-comprovante-da-vers%c3%a3o-final-de-teses-e-disserta%c3%a7%c3%b5es_FMB.pdf
https://repositorio.ufscar.br/bitstream/ufscar/16770/5/Dissertacao_Final_Fernanda_Basso.pdf.txt
https://repositorio.ufscar.br/bitstream/ufscar/16770/7/Carta-comprovante-da-vers%c3%a3o-final-de-teses-e-disserta%c3%a7%c3%b5es_FMB.pdf.txt
https://repositorio.ufscar.br/bitstream/ufscar/16770/6/Dissertacao_Final_Fernanda_Basso.pdf.jpg
https://repositorio.ufscar.br/bitstream/ufscar/16770/8/Carta-comprovante-da-vers%c3%a3o-final-de-teses-e-disserta%c3%a7%c3%b5es_FMB.pdf.jpg
bitstream.checksum.fl_str_mv e39d27027a6cc9cb039ad269a5db8e34
c2863d9daa13e336ee9b39e07b3208a1
0aca01f38a217aff31add7bf5a89568a
4239a772ec7d1b45a1e3bdd272a58236
6eb5d876b986491b23bd0582b2b6bb64
958c5ccb7563deae689fd0098a68a136
dfa4e48490519e315a54ade5280ca09d
bitstream.checksumAlgorithm.fl_str_mv MD5
MD5
MD5
MD5
MD5
MD5
MD5
repository.name.fl_str_mv Repositório Institucional da UFSCAR - Universidade Federal de São Carlos (UFSCAR)
repository.mail.fl_str_mv
_version_ 1802136411970732032