Assessment of the Performance and Surface Alteration of Two Single-file Systems According to the Number of Uses

Detalhes bibliográficos
Autor(a) principal: Porto-Pires,Márcia Virginia M.
Data de Publicação: 2020
Outros Autores: Nabeshima,Cleber Keiti, Caballero-Flores,Hector, Machado,Manoel Eduardo de Lima
Tipo de documento: Artigo
Idioma: eng
Título da fonte: Brazilian Archives of Biology and Technology
Texto Completo: http://old.scielo.br/scielo.php?script=sci_arttext&pid=S1516-89132020000100606
Resumo: Abstract The aim of this study was to assess the performance and surface alteration of two single-file systems according to the number of uses. Ten WaveOne Primary files (25/.08) and ten One Shape NG files (25/.06) were used for instrumentation of mesial root canals of mandibular molars. Each instrument was cleaned and sterilized after the preparation of two root canals and then reused. The time spent for instrumentation of each root canal was recorded and analyzed by using t-test. Microphotographs of the surface of the instruments were taken with a scanning electron microscope at different magnifications (i.e. 18x, 160x, 500x and 1000x) and at a distance of 4 mm from the instrument’s tip before being analyzed by four observers. Presence of disruption of cutting edge, crack, craters and unwinding was assessed and submitted to Fisher’s exact test. Both systems showed manufacturing defects and cracks. The presence of disruption of cutting edges was major in WaveOne files from the sixth use, whereas One Shape NG files showed more unwinding. Only preparation time using WaveOne files was influenced by the number of uses. One can conclude that WaveOne files had more disruption of cutting edges and took longer time for root canal preparation from the sixth use onwards, whereas the One Shape NG files showed more unwinding at the tenth use.
id TECPAR-1_08ef74ec9bba3ac9e7fd844ed82a0d91
oai_identifier_str oai:scielo:S1516-89132020000100606
network_acronym_str TECPAR-1
network_name_str Brazilian Archives of Biology and Technology
repository_id_str
spelling Assessment of the Performance and Surface Alteration of Two Single-file Systems According to the Number of Usessingle-filereuseroot canal instrumentationAbstract The aim of this study was to assess the performance and surface alteration of two single-file systems according to the number of uses. Ten WaveOne Primary files (25/.08) and ten One Shape NG files (25/.06) were used for instrumentation of mesial root canals of mandibular molars. Each instrument was cleaned and sterilized after the preparation of two root canals and then reused. The time spent for instrumentation of each root canal was recorded and analyzed by using t-test. Microphotographs of the surface of the instruments were taken with a scanning electron microscope at different magnifications (i.e. 18x, 160x, 500x and 1000x) and at a distance of 4 mm from the instrument’s tip before being analyzed by four observers. Presence of disruption of cutting edge, crack, craters and unwinding was assessed and submitted to Fisher’s exact test. Both systems showed manufacturing defects and cracks. The presence of disruption of cutting edges was major in WaveOne files from the sixth use, whereas One Shape NG files showed more unwinding. Only preparation time using WaveOne files was influenced by the number of uses. One can conclude that WaveOne files had more disruption of cutting edges and took longer time for root canal preparation from the sixth use onwards, whereas the One Shape NG files showed more unwinding at the tenth use.Instituto de Tecnologia do Paraná - Tecpar2020-01-01info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersiontext/htmlhttp://old.scielo.br/scielo.php?script=sci_arttext&pid=S1516-89132020000100606Brazilian Archives of Biology and Technology v.63 2020reponame:Brazilian Archives of Biology and Technologyinstname:Instituto de Tecnologia do Paraná (Tecpar)instacron:TECPAR10.1590/1678-4324-2020180500info:eu-repo/semantics/openAccessPorto-Pires,Márcia Virginia M.Nabeshima,Cleber KeitiCaballero-Flores,HectorMachado,Manoel Eduardo de Limaeng2020-08-27T00:00:00Zoai:scielo:S1516-89132020000100606Revistahttps://www.scielo.br/j/babt/https://old.scielo.br/oai/scielo-oai.phpbabt@tecpar.br||babt@tecpar.br1678-43241516-8913opendoar:2020-08-27T00:00Brazilian Archives of Biology and Technology - Instituto de Tecnologia do Paraná (Tecpar)false
dc.title.none.fl_str_mv Assessment of the Performance and Surface Alteration of Two Single-file Systems According to the Number of Uses
title Assessment of the Performance and Surface Alteration of Two Single-file Systems According to the Number of Uses
spellingShingle Assessment of the Performance and Surface Alteration of Two Single-file Systems According to the Number of Uses
Porto-Pires,Márcia Virginia M.
single-file
reuse
root canal instrumentation
title_short Assessment of the Performance and Surface Alteration of Two Single-file Systems According to the Number of Uses
title_full Assessment of the Performance and Surface Alteration of Two Single-file Systems According to the Number of Uses
title_fullStr Assessment of the Performance and Surface Alteration of Two Single-file Systems According to the Number of Uses
title_full_unstemmed Assessment of the Performance and Surface Alteration of Two Single-file Systems According to the Number of Uses
title_sort Assessment of the Performance and Surface Alteration of Two Single-file Systems According to the Number of Uses
author Porto-Pires,Márcia Virginia M.
author_facet Porto-Pires,Márcia Virginia M.
Nabeshima,Cleber Keiti
Caballero-Flores,Hector
Machado,Manoel Eduardo de Lima
author_role author
author2 Nabeshima,Cleber Keiti
Caballero-Flores,Hector
Machado,Manoel Eduardo de Lima
author2_role author
author
author
dc.contributor.author.fl_str_mv Porto-Pires,Márcia Virginia M.
Nabeshima,Cleber Keiti
Caballero-Flores,Hector
Machado,Manoel Eduardo de Lima
dc.subject.por.fl_str_mv single-file
reuse
root canal instrumentation
topic single-file
reuse
root canal instrumentation
description Abstract The aim of this study was to assess the performance and surface alteration of two single-file systems according to the number of uses. Ten WaveOne Primary files (25/.08) and ten One Shape NG files (25/.06) were used for instrumentation of mesial root canals of mandibular molars. Each instrument was cleaned and sterilized after the preparation of two root canals and then reused. The time spent for instrumentation of each root canal was recorded and analyzed by using t-test. Microphotographs of the surface of the instruments were taken with a scanning electron microscope at different magnifications (i.e. 18x, 160x, 500x and 1000x) and at a distance of 4 mm from the instrument’s tip before being analyzed by four observers. Presence of disruption of cutting edge, crack, craters and unwinding was assessed and submitted to Fisher’s exact test. Both systems showed manufacturing defects and cracks. The presence of disruption of cutting edges was major in WaveOne files from the sixth use, whereas One Shape NG files showed more unwinding. Only preparation time using WaveOne files was influenced by the number of uses. One can conclude that WaveOne files had more disruption of cutting edges and took longer time for root canal preparation from the sixth use onwards, whereas the One Shape NG files showed more unwinding at the tenth use.
publishDate 2020
dc.date.none.fl_str_mv 2020-01-01
dc.type.driver.fl_str_mv info:eu-repo/semantics/article
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
format article
status_str publishedVersion
dc.identifier.uri.fl_str_mv http://old.scielo.br/scielo.php?script=sci_arttext&pid=S1516-89132020000100606
url http://old.scielo.br/scielo.php?script=sci_arttext&pid=S1516-89132020000100606
dc.language.iso.fl_str_mv eng
language eng
dc.relation.none.fl_str_mv 10.1590/1678-4324-2020180500
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv text/html
dc.publisher.none.fl_str_mv Instituto de Tecnologia do Paraná - Tecpar
publisher.none.fl_str_mv Instituto de Tecnologia do Paraná - Tecpar
dc.source.none.fl_str_mv Brazilian Archives of Biology and Technology v.63 2020
reponame:Brazilian Archives of Biology and Technology
instname:Instituto de Tecnologia do Paraná (Tecpar)
instacron:TECPAR
instname_str Instituto de Tecnologia do Paraná (Tecpar)
instacron_str TECPAR
institution TECPAR
reponame_str Brazilian Archives of Biology and Technology
collection Brazilian Archives of Biology and Technology
repository.name.fl_str_mv Brazilian Archives of Biology and Technology - Instituto de Tecnologia do Paraná (Tecpar)
repository.mail.fl_str_mv babt@tecpar.br||babt@tecpar.br
_version_ 1750318280083505152