Indoor Air Quality in the Hospital: The Influence of Heating, Ventilating and Conditioning Systems
Autor(a) principal: | |
---|---|
Data de Publicação: | 2019 |
Outros Autores: | , |
Tipo de documento: | Artigo |
Idioma: | eng |
Título da fonte: | Brazilian Archives of Biology and Technology |
Texto Completo: | http://old.scielo.br/scielo.php?script=sci_arttext&pid=S1516-89132019000100607 |
Resumo: | Abstract Clean, fresh air is the most important requirement for good indoor air quality (IAQ) in all buildings, but it is especially important with regard to the environments within hospitals and other healthcare facilities. The literature indicates that buildings with heating, ventilating and air conditioning (HVAC) systems may have an increased risk of sick building syndrome (SBS) and building-related illness (BRI) if they are not well maintained. Microorganisms are brought into hospitals by people, air currents, water, construction materials and equipment. The main objective of this study was to assess the degree of fungal and bacterial contamination in the University Clinical Centre in Banja Luka, which is directly connected to the HVAC system. Airborne bacteria and fungi in the indoor hospital environment were assessed experimentally. Air samples were collected during the winter season. This paper presents the results related to the concentration of microorganisms expressed in colony forming units per cubic metre of air sampled (in CFU/m3) together with the microclimatic parameters temperature and relative humidity. The results of monitoring indicate the effectiveness of HVAC systems in reducing microbiological contamination. |
id |
TECPAR-1_282e4043caf3adcf4fdaa728ba920d18 |
---|---|
oai_identifier_str |
oai:scielo:S1516-89132019000100607 |
network_acronym_str |
TECPAR-1 |
network_name_str |
Brazilian Archives of Biology and Technology |
repository_id_str |
|
spelling |
Indoor Air Quality in the Hospital: The Influence of Heating, Ventilating and Conditioning Systemsindoor air qualityhospitalHVAC systembacteriafungiAbstract Clean, fresh air is the most important requirement for good indoor air quality (IAQ) in all buildings, but it is especially important with regard to the environments within hospitals and other healthcare facilities. The literature indicates that buildings with heating, ventilating and air conditioning (HVAC) systems may have an increased risk of sick building syndrome (SBS) and building-related illness (BRI) if they are not well maintained. Microorganisms are brought into hospitals by people, air currents, water, construction materials and equipment. The main objective of this study was to assess the degree of fungal and bacterial contamination in the University Clinical Centre in Banja Luka, which is directly connected to the HVAC system. Airborne bacteria and fungi in the indoor hospital environment were assessed experimentally. Air samples were collected during the winter season. This paper presents the results related to the concentration of microorganisms expressed in colony forming units per cubic metre of air sampled (in CFU/m3) together with the microclimatic parameters temperature and relative humidity. The results of monitoring indicate the effectiveness of HVAC systems in reducing microbiological contamination.Instituto de Tecnologia do Paraná - Tecpar2019-01-01info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersiontext/htmlhttp://old.scielo.br/scielo.php?script=sci_arttext&pid=S1516-89132019000100607Brazilian Archives of Biology and Technology v.62 2019reponame:Brazilian Archives of Biology and Technologyinstname:Instituto de Tecnologia do Paraná (Tecpar)instacron:TECPAR10.1590/1678-4324-2019180295info:eu-repo/semantics/openAccessBožić,JelenaIlić,Predragilić,Svetlanaeng2019-09-05T00:00:00Zoai:scielo:S1516-89132019000100607Revistahttps://www.scielo.br/j/babt/https://old.scielo.br/oai/scielo-oai.phpbabt@tecpar.br||babt@tecpar.br1678-43241516-8913opendoar:2019-09-05T00:00Brazilian Archives of Biology and Technology - Instituto de Tecnologia do Paraná (Tecpar)false |
dc.title.none.fl_str_mv |
Indoor Air Quality in the Hospital: The Influence of Heating, Ventilating and Conditioning Systems |
title |
Indoor Air Quality in the Hospital: The Influence of Heating, Ventilating and Conditioning Systems |
spellingShingle |
Indoor Air Quality in the Hospital: The Influence of Heating, Ventilating and Conditioning Systems Božić,Jelena indoor air quality hospital HVAC system bacteria fungi |
title_short |
Indoor Air Quality in the Hospital: The Influence of Heating, Ventilating and Conditioning Systems |
title_full |
Indoor Air Quality in the Hospital: The Influence of Heating, Ventilating and Conditioning Systems |
title_fullStr |
Indoor Air Quality in the Hospital: The Influence of Heating, Ventilating and Conditioning Systems |
title_full_unstemmed |
Indoor Air Quality in the Hospital: The Influence of Heating, Ventilating and Conditioning Systems |
title_sort |
Indoor Air Quality in the Hospital: The Influence of Heating, Ventilating and Conditioning Systems |
author |
Božić,Jelena |
author_facet |
Božić,Jelena Ilić,Predrag ilić,Svetlana |
author_role |
author |
author2 |
Ilić,Predrag ilić,Svetlana |
author2_role |
author author |
dc.contributor.author.fl_str_mv |
Božić,Jelena Ilić,Predrag ilić,Svetlana |
dc.subject.por.fl_str_mv |
indoor air quality hospital HVAC system bacteria fungi |
topic |
indoor air quality hospital HVAC system bacteria fungi |
description |
Abstract Clean, fresh air is the most important requirement for good indoor air quality (IAQ) in all buildings, but it is especially important with regard to the environments within hospitals and other healthcare facilities. The literature indicates that buildings with heating, ventilating and air conditioning (HVAC) systems may have an increased risk of sick building syndrome (SBS) and building-related illness (BRI) if they are not well maintained. Microorganisms are brought into hospitals by people, air currents, water, construction materials and equipment. The main objective of this study was to assess the degree of fungal and bacterial contamination in the University Clinical Centre in Banja Luka, which is directly connected to the HVAC system. Airborne bacteria and fungi in the indoor hospital environment were assessed experimentally. Air samples were collected during the winter season. This paper presents the results related to the concentration of microorganisms expressed in colony forming units per cubic metre of air sampled (in CFU/m3) together with the microclimatic parameters temperature and relative humidity. The results of monitoring indicate the effectiveness of HVAC systems in reducing microbiological contamination. |
publishDate |
2019 |
dc.date.none.fl_str_mv |
2019-01-01 |
dc.type.driver.fl_str_mv |
info:eu-repo/semantics/article |
dc.type.status.fl_str_mv |
info:eu-repo/semantics/publishedVersion |
format |
article |
status_str |
publishedVersion |
dc.identifier.uri.fl_str_mv |
http://old.scielo.br/scielo.php?script=sci_arttext&pid=S1516-89132019000100607 |
url |
http://old.scielo.br/scielo.php?script=sci_arttext&pid=S1516-89132019000100607 |
dc.language.iso.fl_str_mv |
eng |
language |
eng |
dc.relation.none.fl_str_mv |
10.1590/1678-4324-2019180295 |
dc.rights.driver.fl_str_mv |
info:eu-repo/semantics/openAccess |
eu_rights_str_mv |
openAccess |
dc.format.none.fl_str_mv |
text/html |
dc.publisher.none.fl_str_mv |
Instituto de Tecnologia do Paraná - Tecpar |
publisher.none.fl_str_mv |
Instituto de Tecnologia do Paraná - Tecpar |
dc.source.none.fl_str_mv |
Brazilian Archives of Biology and Technology v.62 2019 reponame:Brazilian Archives of Biology and Technology instname:Instituto de Tecnologia do Paraná (Tecpar) instacron:TECPAR |
instname_str |
Instituto de Tecnologia do Paraná (Tecpar) |
instacron_str |
TECPAR |
institution |
TECPAR |
reponame_str |
Brazilian Archives of Biology and Technology |
collection |
Brazilian Archives of Biology and Technology |
repository.name.fl_str_mv |
Brazilian Archives of Biology and Technology - Instituto de Tecnologia do Paraná (Tecpar) |
repository.mail.fl_str_mv |
babt@tecpar.br||babt@tecpar.br |
_version_ |
1750318279563411456 |