Texto Completo: http://old.scielo.br/scielo.php?script=sci_arttext&pid=S1516-89132019000100607
Resumo: Abstract Clean, fresh air is the most important requirement for good indoor air quality (IAQ) in all buildings, but it is especially important with regard to the environments within hospitals and other healthcare facilities. The literature indicates that buildings with heating, ventilating and air conditioning (HVAC) systems may have an increased risk of sick building syndrome (SBS) and building-related illness (BRI) if they are not well maintained. Microorganisms are brought into hospitals by people, air currents, water, construction materials and equipment. The main objective of this study was to assess the degree of fungal and bacterial contamination in the University Clinical Centre in Banja Luka, which is directly connected to the HVAC system. Airborne bacteria and fungi in the indoor hospital environment were assessed experimentally. Air samples were collected during the winter season. This paper presents the results related to the concentration of microorganisms expressed in colony forming units per cubic metre of air sampled (in CFU/m3) together with the microclimatic parameters temperature and relative humidity. The results of monitoring indicate the effectiveness of HVAC systems in reducing microbiological contamination.
id TECPAR-1_282e4043caf3adcf4fdaa728ba920d18
oai_identifier_str oai:scielo:S1516-89132019000100607
network_acronym_str TECPAR-1
network_name_str Brazilian Archives of Biology and Technology
repository_id_str
spelling Indoor Air Quality in the Hospital: The Influence of Heating, Ventilating and Conditioning Systemsindoor air qualityhospitalHVAC systembacteriafungiAbstract Clean, fresh air is the most important requirement for good indoor air quality (IAQ) in all buildings, but it is especially important with regard to the environments within hospitals and other healthcare facilities. The literature indicates that buildings with heating, ventilating and air conditioning (HVAC) systems may have an increased risk of sick building syndrome (SBS) and building-related illness (BRI) if they are not well maintained. Microorganisms are brought into hospitals by people, air currents, water, construction materials and equipment. The main objective of this study was to assess the degree of fungal and bacterial contamination in the University Clinical Centre in Banja Luka, which is directly connected to the HVAC system. Airborne bacteria and fungi in the indoor hospital environment were assessed experimentally. Air samples were collected during the winter season. This paper presents the results related to the concentration of microorganisms expressed in colony forming units per cubic metre of air sampled (in CFU/m3) together with the microclimatic parameters temperature and relative humidity. The results of monitoring indicate the effectiveness of HVAC systems in reducing microbiological contamination.Instituto de Tecnologia do Paraná - Tecpar2019-01-01info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersiontext/htmlhttp://old.scielo.br/scielo.php?script=sci_arttext&pid=S1516-89132019000100607Brazilian Archives of Biology and Technology v.62 2019reponame:Brazilian Archives of Biology and Technologyinstname:Instituto de Tecnologia do Paraná (Tecpar)instacron:TECPAR10.1590/1678-4324-2019180295info:eu-repo/semantics/openAccessBožić,JelenaIlić,Predragilić,Svetlanaeng2019-09-05T00:00:00Zoai:scielo:S1516-89132019000100607Revistahttps://www.scielo.br/j/babt/https://old.scielo.br/oai/scielo-oai.phpbabt@tecpar.br||babt@tecpar.br1678-43241516-8913opendoar:2019-09-05T00:00Brazilian Archives of Biology and Technology - Instituto de Tecnologia do Paraná (Tecpar)false
dc.title.none.fl_str_mv Indoor Air Quality in the Hospital: The Influence of Heating, Ventilating and Conditioning Systems
title Indoor Air Quality in the Hospital: The Influence of Heating, Ventilating and Conditioning Systems
spellingShingle Indoor Air Quality in the Hospital: The Influence of Heating, Ventilating and Conditioning Systems
Božić,Jelena
indoor air quality
hospital
HVAC system
bacteria
fungi
title_short Indoor Air Quality in the Hospital: The Influence of Heating, Ventilating and Conditioning Systems
title_full Indoor Air Quality in the Hospital: The Influence of Heating, Ventilating and Conditioning Systems
title_fullStr Indoor Air Quality in the Hospital: The Influence of Heating, Ventilating and Conditioning Systems
title_full_unstemmed Indoor Air Quality in the Hospital: The Influence of Heating, Ventilating and Conditioning Systems
title_sort Indoor Air Quality in the Hospital: The Influence of Heating, Ventilating and Conditioning Systems
author Božić,Jelena
author_facet Božić,Jelena
Ilić,Predrag
ilić,Svetlana
author_role author
author2 Ilić,Predrag
ilić,Svetlana
author2_role author
author
dc.contributor.author.fl_str_mv Božić,Jelena
Ilić,Predrag
ilić,Svetlana
dc.subject.por.fl_str_mv indoor air quality
hospital
HVAC system
bacteria
fungi
topic indoor air quality
hospital
HVAC system
bacteria
fungi
description Abstract Clean, fresh air is the most important requirement for good indoor air quality (IAQ) in all buildings, but it is especially important with regard to the environments within hospitals and other healthcare facilities. The literature indicates that buildings with heating, ventilating and air conditioning (HVAC) systems may have an increased risk of sick building syndrome (SBS) and building-related illness (BRI) if they are not well maintained. Microorganisms are brought into hospitals by people, air currents, water, construction materials and equipment. The main objective of this study was to assess the degree of fungal and bacterial contamination in the University Clinical Centre in Banja Luka, which is directly connected to the HVAC system. Airborne bacteria and fungi in the indoor hospital environment were assessed experimentally. Air samples were collected during the winter season. This paper presents the results related to the concentration of microorganisms expressed in colony forming units per cubic metre of air sampled (in CFU/m3) together with the microclimatic parameters temperature and relative humidity. The results of monitoring indicate the effectiveness of HVAC systems in reducing microbiological contamination.
publishDate 2019
dc.date.none.fl_str_mv 2019-01-01
dc.type.driver.fl_str_mv info:eu-repo/semantics/article
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
format article
status_str publishedVersion
dc.identifier.uri.fl_str_mv http://old.scielo.br/scielo.php?script=sci_arttext&pid=S1516-89132019000100607
url http://old.scielo.br/scielo.php?script=sci_arttext&pid=S1516-89132019000100607
dc.language.iso.fl_str_mv eng
language eng
dc.relation.none.fl_str_mv 10.1590/1678-4324-2019180295
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv text/html
dc.publisher.none.fl_str_mv Instituto de Tecnologia do Paraná - Tecpar
publisher.none.fl_str_mv Instituto de Tecnologia do Paraná - Tecpar
dc.source.none.fl_str_mv Brazilian Archives of Biology and Technology v.62 2019
reponame:Brazilian Archives of Biology and Technology
instname:Instituto de Tecnologia do Paraná (Tecpar)
instacron:TECPAR
instname_str Instituto de Tecnologia do Paraná (Tecpar)
instacron_str TECPAR
institution TECPAR
reponame_str Brazilian Archives of Biology and Technology
collection Brazilian Archives of Biology and Technology
repository.name.fl_str_mv Brazilian Archives of Biology and Technology - Instituto de Tecnologia do Paraná (Tecpar)
repository.mail.fl_str_mv babt@tecpar.br||babt@tecpar.br
_version_ 1750318279563411456