Estimating Hydroxymethyfurfural (HMF) Concentration Via Modified Seliwanoff Test Using Artificial Neural Network (ANN)
Autor(a) principal: | |
---|---|
Data de Publicação: | 2021 |
Outros Autores: | , |
Tipo de documento: | Artigo |
Idioma: | eng |
Título da fonte: | Brazilian Archives of Biology and Technology |
Texto Completo: | http://old.scielo.br/scielo.php?script=sci_arttext&pid=S1516-89132021000100512 |
Resumo: | Abstract Hydroxymethylfurfural (HMF) is a quality indicator, especially in foods where changes in protein-carbohydrate interactions are observed during the applied process. In this study absorbance and L*, a*, b* values of red color emerged due to the relationship between hydroxymethylfurfural (HMF) and resorcinol during the modified Seliwanoff test were used as input data artificial neural network (ANN) to determine the HMF concentration for the first time. A linear relationship, between HMF concentration and absorbance of red color, can be represented by equation absorbance = 0.0020 + 0.0012* concentration of HMF (mg L-1) with R2 = 99.6%, Fisher ratio: 0.18, p value of lack of fit: 0.975, correlation coefficient: 0.9960. Intra-day and inter-day precision expressed as relative standard deviation (RSD) %, were 2.35 - 3.65% and 3.16 - 4.73%, respectively. Recovery rates and RSDs were in the range of 99.34 - 100.47% and 1.58 - 3.68%. It showed high correlation compared to HPLC method used as reference method (0.998). The R2 values of ANN for estimation of HMF concentration were found 0.90 for training, 0.96 for validation, and 0.99 for testing and AARD was found 8.85%. Evaluation of the absorbance and L*, a*, b* values of the red color with artificial intelligence is a reliable way to determine the HMF concentration. |
id |
TECPAR-1_5016b33bd49c22406dd831bc5b070c2a |
---|---|
oai_identifier_str |
oai:scielo:S1516-89132021000100512 |
network_acronym_str |
TECPAR-1 |
network_name_str |
Brazilian Archives of Biology and Technology |
repository_id_str |
|
spelling |
Estimating Hydroxymethyfurfural (HMF) Concentration Via Modified Seliwanoff Test Using Artificial Neural Network (ANN)hydroxymethylfurfural (HMF)seliwanoff testartificial neural network (ANN)Abstract Hydroxymethylfurfural (HMF) is a quality indicator, especially in foods where changes in protein-carbohydrate interactions are observed during the applied process. In this study absorbance and L*, a*, b* values of red color emerged due to the relationship between hydroxymethylfurfural (HMF) and resorcinol during the modified Seliwanoff test were used as input data artificial neural network (ANN) to determine the HMF concentration for the first time. A linear relationship, between HMF concentration and absorbance of red color, can be represented by equation absorbance = 0.0020 + 0.0012* concentration of HMF (mg L-1) with R2 = 99.6%, Fisher ratio: 0.18, p value of lack of fit: 0.975, correlation coefficient: 0.9960. Intra-day and inter-day precision expressed as relative standard deviation (RSD) %, were 2.35 - 3.65% and 3.16 - 4.73%, respectively. Recovery rates and RSDs were in the range of 99.34 - 100.47% and 1.58 - 3.68%. It showed high correlation compared to HPLC method used as reference method (0.998). The R2 values of ANN for estimation of HMF concentration were found 0.90 for training, 0.96 for validation, and 0.99 for testing and AARD was found 8.85%. Evaluation of the absorbance and L*, a*, b* values of the red color with artificial intelligence is a reliable way to determine the HMF concentration.Instituto de Tecnologia do Paraná - Tecpar2021-01-01info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersiontext/htmlhttp://old.scielo.br/scielo.php?script=sci_arttext&pid=S1516-89132021000100512Brazilian Archives of Biology and Technology v.64 2021reponame:Brazilian Archives of Biology and Technologyinstname:Instituto de Tecnologia do Paraná (Tecpar)instacron:TECPAR10.1590/1678-4324-2021210194info:eu-repo/semantics/openAccessBesir,AysegulYazici,FehmiOdabas,Mehmet Serhateng2022-01-07T00:00:00Zoai:scielo:S1516-89132021000100512Revistahttps://www.scielo.br/j/babt/https://old.scielo.br/oai/scielo-oai.phpbabt@tecpar.br||babt@tecpar.br1678-43241516-8913opendoar:2022-01-07T00:00Brazilian Archives of Biology and Technology - Instituto de Tecnologia do Paraná (Tecpar)false |
dc.title.none.fl_str_mv |
Estimating Hydroxymethyfurfural (HMF) Concentration Via Modified Seliwanoff Test Using Artificial Neural Network (ANN) |
title |
Estimating Hydroxymethyfurfural (HMF) Concentration Via Modified Seliwanoff Test Using Artificial Neural Network (ANN) |
spellingShingle |
Estimating Hydroxymethyfurfural (HMF) Concentration Via Modified Seliwanoff Test Using Artificial Neural Network (ANN) Besir,Aysegul hydroxymethylfurfural (HMF) seliwanoff test artificial neural network (ANN) |
title_short |
Estimating Hydroxymethyfurfural (HMF) Concentration Via Modified Seliwanoff Test Using Artificial Neural Network (ANN) |
title_full |
Estimating Hydroxymethyfurfural (HMF) Concentration Via Modified Seliwanoff Test Using Artificial Neural Network (ANN) |
title_fullStr |
Estimating Hydroxymethyfurfural (HMF) Concentration Via Modified Seliwanoff Test Using Artificial Neural Network (ANN) |
title_full_unstemmed |
Estimating Hydroxymethyfurfural (HMF) Concentration Via Modified Seliwanoff Test Using Artificial Neural Network (ANN) |
title_sort |
Estimating Hydroxymethyfurfural (HMF) Concentration Via Modified Seliwanoff Test Using Artificial Neural Network (ANN) |
author |
Besir,Aysegul |
author_facet |
Besir,Aysegul Yazici,Fehmi Odabas,Mehmet Serhat |
author_role |
author |
author2 |
Yazici,Fehmi Odabas,Mehmet Serhat |
author2_role |
author author |
dc.contributor.author.fl_str_mv |
Besir,Aysegul Yazici,Fehmi Odabas,Mehmet Serhat |
dc.subject.por.fl_str_mv |
hydroxymethylfurfural (HMF) seliwanoff test artificial neural network (ANN) |
topic |
hydroxymethylfurfural (HMF) seliwanoff test artificial neural network (ANN) |
description |
Abstract Hydroxymethylfurfural (HMF) is a quality indicator, especially in foods where changes in protein-carbohydrate interactions are observed during the applied process. In this study absorbance and L*, a*, b* values of red color emerged due to the relationship between hydroxymethylfurfural (HMF) and resorcinol during the modified Seliwanoff test were used as input data artificial neural network (ANN) to determine the HMF concentration for the first time. A linear relationship, between HMF concentration and absorbance of red color, can be represented by equation absorbance = 0.0020 + 0.0012* concentration of HMF (mg L-1) with R2 = 99.6%, Fisher ratio: 0.18, p value of lack of fit: 0.975, correlation coefficient: 0.9960. Intra-day and inter-day precision expressed as relative standard deviation (RSD) %, were 2.35 - 3.65% and 3.16 - 4.73%, respectively. Recovery rates and RSDs were in the range of 99.34 - 100.47% and 1.58 - 3.68%. It showed high correlation compared to HPLC method used as reference method (0.998). The R2 values of ANN for estimation of HMF concentration were found 0.90 for training, 0.96 for validation, and 0.99 for testing and AARD was found 8.85%. Evaluation of the absorbance and L*, a*, b* values of the red color with artificial intelligence is a reliable way to determine the HMF concentration. |
publishDate |
2021 |
dc.date.none.fl_str_mv |
2021-01-01 |
dc.type.driver.fl_str_mv |
info:eu-repo/semantics/article |
dc.type.status.fl_str_mv |
info:eu-repo/semantics/publishedVersion |
format |
article |
status_str |
publishedVersion |
dc.identifier.uri.fl_str_mv |
http://old.scielo.br/scielo.php?script=sci_arttext&pid=S1516-89132021000100512 |
url |
http://old.scielo.br/scielo.php?script=sci_arttext&pid=S1516-89132021000100512 |
dc.language.iso.fl_str_mv |
eng |
language |
eng |
dc.relation.none.fl_str_mv |
10.1590/1678-4324-2021210194 |
dc.rights.driver.fl_str_mv |
info:eu-repo/semantics/openAccess |
eu_rights_str_mv |
openAccess |
dc.format.none.fl_str_mv |
text/html |
dc.publisher.none.fl_str_mv |
Instituto de Tecnologia do Paraná - Tecpar |
publisher.none.fl_str_mv |
Instituto de Tecnologia do Paraná - Tecpar |
dc.source.none.fl_str_mv |
Brazilian Archives of Biology and Technology v.64 2021 reponame:Brazilian Archives of Biology and Technology instname:Instituto de Tecnologia do Paraná (Tecpar) instacron:TECPAR |
instname_str |
Instituto de Tecnologia do Paraná (Tecpar) |
instacron_str |
TECPAR |
institution |
TECPAR |
reponame_str |
Brazilian Archives of Biology and Technology |
collection |
Brazilian Archives of Biology and Technology |
repository.name.fl_str_mv |
Brazilian Archives of Biology and Technology - Instituto de Tecnologia do Paraná (Tecpar) |
repository.mail.fl_str_mv |
babt@tecpar.br||babt@tecpar.br |
_version_ |
1750318280865742848 |