Resumo: According to the Technical Regulation of Measurement of Petroleum and Natural Gas (approved in 2000 by ANP - the Petroleum National Agency of Brazil), the systems of measurement of natural gas should use ultra-sonic flow meters, turbines and, especially, the orifice plates, which represent the most expressive base of the flow systems, being used in the fiscal and operational measurements. This work aims to evaluate the parameters that should be accounted for during the dimensional inspection of orifice plate and roughness of the straight stretches of the tubing used for measurement of natural gas, with the objective of guiding the responsible professionals for the measurement of volumes of natural gas by orifice plate, as well as the professionals of calibration laboratories. In this work, minimum specifications are recommended, irrespective of the pressure tapping or orifice type, in agreement with the norms ISO, AGA and the ANP regulations. The influence of these specifications on the parameters used in the calculation of the volumetric flow is also analyzed.
id TECPAR-1_603d75b062343df1a8b0e6da7c7663a7
oai_identifier_str oai:scielo:S1516-89132006000200002
network_acronym_str TECPAR-1
network_name_str Brazilian Archives of Biology and Technology
repository_id_str
spelling Parameters for dimensional inspection of orifice plates and roughness of the straight stretches of the tubingOrifice platesuperficial roughnessmeasurement parametersAccording to the Technical Regulation of Measurement of Petroleum and Natural Gas (approved in 2000 by ANP - the Petroleum National Agency of Brazil), the systems of measurement of natural gas should use ultra-sonic flow meters, turbines and, especially, the orifice plates, which represent the most expressive base of the flow systems, being used in the fiscal and operational measurements. This work aims to evaluate the parameters that should be accounted for during the dimensional inspection of orifice plate and roughness of the straight stretches of the tubing used for measurement of natural gas, with the objective of guiding the responsible professionals for the measurement of volumes of natural gas by orifice plate, as well as the professionals of calibration laboratories. In this work, minimum specifications are recommended, irrespective of the pressure tapping or orifice type, in agreement with the norms ISO, AGA and the ANP regulations. The influence of these specifications on the parameters used in the calculation of the volumetric flow is also analyzed.Instituto de Tecnologia do Paraná - Tecpar2006-01-01info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersiontext/htmlhttp://old.scielo.br/scielo.php?script=sci_arttext&pid=S1516-89132006000200002Brazilian Archives of Biology and Technology v.49 n.spe 2006reponame:Brazilian Archives of Biology and Technologyinstname:Instituto de Tecnologia do Paraná (Tecpar)instacron:TECPAR10.1590/S1516-89132006000200002info:eu-repo/semantics/openAccessMedeiros,Alberto Kennedy de AlmeidaLima,Jeffersson Fernandes deMedeiros,Gilson Gomes deSilva Junior,Nivaldo Ferreira daFelipe,Raimundo Nonato B.Felipe,Renata Carla Tavares dos Santoseng2006-03-30T00:00:00Zoai:scielo:S1516-89132006000200002Revistahttps://www.scielo.br/j/babt/https://old.scielo.br/oai/scielo-oai.phpbabt@tecpar.br||babt@tecpar.br1678-43241516-8913opendoar:2006-03-30T00:00Brazilian Archives of Biology and Technology - Instituto de Tecnologia do Paraná (Tecpar)false
dc.title.none.fl_str_mv Parameters for dimensional inspection of orifice plates and roughness of the straight stretches of the tubing
title Parameters for dimensional inspection of orifice plates and roughness of the straight stretches of the tubing
spellingShingle Parameters for dimensional inspection of orifice plates and roughness of the straight stretches of the tubing
Medeiros,Alberto Kennedy de Almeida
Orifice plate
superficial roughness
measurement parameters
title_short Parameters for dimensional inspection of orifice plates and roughness of the straight stretches of the tubing
title_full Parameters for dimensional inspection of orifice plates and roughness of the straight stretches of the tubing
title_fullStr Parameters for dimensional inspection of orifice plates and roughness of the straight stretches of the tubing
title_full_unstemmed Parameters for dimensional inspection of orifice plates and roughness of the straight stretches of the tubing
title_sort Parameters for dimensional inspection of orifice plates and roughness of the straight stretches of the tubing
author Medeiros,Alberto Kennedy de Almeida
author_facet Medeiros,Alberto Kennedy de Almeida
Lima,Jeffersson Fernandes de
Medeiros,Gilson Gomes de
Silva Junior,Nivaldo Ferreira da
Felipe,Raimundo Nonato B.
Felipe,Renata Carla Tavares dos Santos
author_role author
author2 Lima,Jeffersson Fernandes de
Medeiros,Gilson Gomes de
Silva Junior,Nivaldo Ferreira da
Felipe,Raimundo Nonato B.
Felipe,Renata Carla Tavares dos Santos
author2_role author
author
author
author
author
dc.contributor.author.fl_str_mv Medeiros,Alberto Kennedy de Almeida
Lima,Jeffersson Fernandes de
Medeiros,Gilson Gomes de
Silva Junior,Nivaldo Ferreira da
Felipe,Raimundo Nonato B.
Felipe,Renata Carla Tavares dos Santos
dc.subject.por.fl_str_mv Orifice plate
superficial roughness
measurement parameters
topic Orifice plate
superficial roughness
measurement parameters
description According to the Technical Regulation of Measurement of Petroleum and Natural Gas (approved in 2000 by ANP - the Petroleum National Agency of Brazil), the systems of measurement of natural gas should use ultra-sonic flow meters, turbines and, especially, the orifice plates, which represent the most expressive base of the flow systems, being used in the fiscal and operational measurements. This work aims to evaluate the parameters that should be accounted for during the dimensional inspection of orifice plate and roughness of the straight stretches of the tubing used for measurement of natural gas, with the objective of guiding the responsible professionals for the measurement of volumes of natural gas by orifice plate, as well as the professionals of calibration laboratories. In this work, minimum specifications are recommended, irrespective of the pressure tapping or orifice type, in agreement with the norms ISO, AGA and the ANP regulations. The influence of these specifications on the parameters used in the calculation of the volumetric flow is also analyzed.
publishDate 2006
dc.date.none.fl_str_mv 2006-01-01
dc.type.driver.fl_str_mv info:eu-repo/semantics/article
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
format article
status_str publishedVersion
dc.identifier.uri.fl_str_mv http://old.scielo.br/scielo.php?script=sci_arttext&pid=S1516-89132006000200002
url http://old.scielo.br/scielo.php?script=sci_arttext&pid=S1516-89132006000200002
dc.language.iso.fl_str_mv eng
language eng
dc.relation.none.fl_str_mv 10.1590/S1516-89132006000200002
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv text/html
dc.publisher.none.fl_str_mv Instituto de Tecnologia do Paraná - Tecpar
publisher.none.fl_str_mv Instituto de Tecnologia do Paraná - Tecpar
dc.source.none.fl_str_mv Brazilian Archives of Biology and Technology v.49 n.spe 2006
reponame:Brazilian Archives of Biology and Technology
instname:Instituto de Tecnologia do Paraná (Tecpar)
instacron:TECPAR
instname_str Instituto de Tecnologia do Paraná (Tecpar)
instacron_str TECPAR
institution TECPAR
reponame_str Brazilian Archives of Biology and Technology
collection Brazilian Archives of Biology and Technology
repository.name.fl_str_mv Brazilian Archives of Biology and Technology - Instituto de Tecnologia do Paraná (Tecpar)
repository.mail.fl_str_mv babt@tecpar.br||babt@tecpar.br
_version_ 1750318270760615936