Effect of NaCl and HCl concentrations on primary pH measurement for the certification of standard materials
Autor(a) principal: | |
---|---|
Data de Publicação: | 2006 |
Outros Autores: | , , , , , |
Tipo de documento: | Artigo |
Idioma: | eng |
Título da fonte: | Brazilian Archives of Biology and Technology |
Texto Completo: | http://old.scielo.br/scielo.php?script=sci_arttext&pid=S1516-89132006000200013 |
Resumo: | pH is an important parameter to control the production of food, medicine, petrochemical products and others. Thus, standard reference materials used to calibrate pH meters are necessary to guarantee reliability of the measurements. The Chemical Metrology Division (Dquim) of the National Metrology Institute of Brazil (Inmetro) has as one of its missions the certification of standard reference materials. In the case of pH, it will be done by the pH primary measurement system of Inmetro, in operation at Dquim since 2003. The buffer solution of nominal pH value equal to 6.865 will be the first to be certified. The study of some measurement parameters has already been accomplished, and will lead to the improvement of the primary pH measurement. In this paper, the effect of NaCl and HCl concentrations on the primary pH measurement is discussed, based on the results obtained by Inmetro in the regional comparison SIM 8.11P. |
id |
TECPAR-1_6f00ddd0d564c930dcf6c2f5ed513908 |
---|---|
oai_identifier_str |
oai:scielo:S1516-89132006000200013 |
network_acronym_str |
TECPAR-1 |
network_name_str |
Brazilian Archives of Biology and Technology |
repository_id_str |
|
spelling |
Effect of NaCl and HCl concentrations on primary pH measurement for the certification of standard materialsChemical metrologyprimary pHreference materialpH is an important parameter to control the production of food, medicine, petrochemical products and others. Thus, standard reference materials used to calibrate pH meters are necessary to guarantee reliability of the measurements. The Chemical Metrology Division (Dquim) of the National Metrology Institute of Brazil (Inmetro) has as one of its missions the certification of standard reference materials. In the case of pH, it will be done by the pH primary measurement system of Inmetro, in operation at Dquim since 2003. The buffer solution of nominal pH value equal to 6.865 will be the first to be certified. The study of some measurement parameters has already been accomplished, and will lead to the improvement of the primary pH measurement. In this paper, the effect of NaCl and HCl concentrations on the primary pH measurement is discussed, based on the results obtained by Inmetro in the regional comparison SIM 8.11P.Instituto de Tecnologia do Paraná - Tecpar2006-01-01info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersiontext/htmlhttp://old.scielo.br/scielo.php?script=sci_arttext&pid=S1516-89132006000200013Brazilian Archives of Biology and Technology v.49 n.spe 2006reponame:Brazilian Archives of Biology and Technologyinstname:Instituto de Tecnologia do Paraná (Tecpar)instacron:TECPAR10.1590/S1516-89132006000200013info:eu-repo/semantics/openAccessSouza,V.Ordine,Alberto PiresFraga,I. C. S.Getrouw,Monique AudreyBorges,P. P.Damasceno,J. C.Couto,P. R. G.eng2006-03-30T00:00:00Zoai:scielo:S1516-89132006000200013Revistahttps://www.scielo.br/j/babt/https://old.scielo.br/oai/scielo-oai.phpbabt@tecpar.br||babt@tecpar.br1678-43241516-8913opendoar:2006-03-30T00:00Brazilian Archives of Biology and Technology - Instituto de Tecnologia do Paraná (Tecpar)false |
dc.title.none.fl_str_mv |
Effect of NaCl and HCl concentrations on primary pH measurement for the certification of standard materials |
title |
Effect of NaCl and HCl concentrations on primary pH measurement for the certification of standard materials |
spellingShingle |
Effect of NaCl and HCl concentrations on primary pH measurement for the certification of standard materials Souza,V. Chemical metrology primary pH reference material |
title_short |
Effect of NaCl and HCl concentrations on primary pH measurement for the certification of standard materials |
title_full |
Effect of NaCl and HCl concentrations on primary pH measurement for the certification of standard materials |
title_fullStr |
Effect of NaCl and HCl concentrations on primary pH measurement for the certification of standard materials |
title_full_unstemmed |
Effect of NaCl and HCl concentrations on primary pH measurement for the certification of standard materials |
title_sort |
Effect of NaCl and HCl concentrations on primary pH measurement for the certification of standard materials |
author |
Souza,V. |
author_facet |
Souza,V. Ordine,Alberto Pires Fraga,I. C. S. Getrouw,Monique Audrey Borges,P. P. Damasceno,J. C. Couto,P. R. G. |
author_role |
author |
author2 |
Ordine,Alberto Pires Fraga,I. C. S. Getrouw,Monique Audrey Borges,P. P. Damasceno,J. C. Couto,P. R. G. |
author2_role |
author author author author author author |
dc.contributor.author.fl_str_mv |
Souza,V. Ordine,Alberto Pires Fraga,I. C. S. Getrouw,Monique Audrey Borges,P. P. Damasceno,J. C. Couto,P. R. G. |
dc.subject.por.fl_str_mv |
Chemical metrology primary pH reference material |
topic |
Chemical metrology primary pH reference material |
description |
pH is an important parameter to control the production of food, medicine, petrochemical products and others. Thus, standard reference materials used to calibrate pH meters are necessary to guarantee reliability of the measurements. The Chemical Metrology Division (Dquim) of the National Metrology Institute of Brazil (Inmetro) has as one of its missions the certification of standard reference materials. In the case of pH, it will be done by the pH primary measurement system of Inmetro, in operation at Dquim since 2003. The buffer solution of nominal pH value equal to 6.865 will be the first to be certified. The study of some measurement parameters has already been accomplished, and will lead to the improvement of the primary pH measurement. In this paper, the effect of NaCl and HCl concentrations on the primary pH measurement is discussed, based on the results obtained by Inmetro in the regional comparison SIM 8.11P. |
publishDate |
2006 |
dc.date.none.fl_str_mv |
2006-01-01 |
dc.type.driver.fl_str_mv |
info:eu-repo/semantics/article |
dc.type.status.fl_str_mv |
info:eu-repo/semantics/publishedVersion |
format |
article |
status_str |
publishedVersion |
dc.identifier.uri.fl_str_mv |
http://old.scielo.br/scielo.php?script=sci_arttext&pid=S1516-89132006000200013 |
url |
http://old.scielo.br/scielo.php?script=sci_arttext&pid=S1516-89132006000200013 |
dc.language.iso.fl_str_mv |
eng |
language |
eng |
dc.relation.none.fl_str_mv |
10.1590/S1516-89132006000200013 |
dc.rights.driver.fl_str_mv |
info:eu-repo/semantics/openAccess |
eu_rights_str_mv |
openAccess |
dc.format.none.fl_str_mv |
text/html |
dc.publisher.none.fl_str_mv |
Instituto de Tecnologia do Paraná - Tecpar |
publisher.none.fl_str_mv |
Instituto de Tecnologia do Paraná - Tecpar |
dc.source.none.fl_str_mv |
Brazilian Archives of Biology and Technology v.49 n.spe 2006 reponame:Brazilian Archives of Biology and Technology instname:Instituto de Tecnologia do Paraná (Tecpar) instacron:TECPAR |
instname_str |
Instituto de Tecnologia do Paraná (Tecpar) |
instacron_str |
TECPAR |
institution |
TECPAR |
reponame_str |
Brazilian Archives of Biology and Technology |
collection |
Brazilian Archives of Biology and Technology |
repository.name.fl_str_mv |
Brazilian Archives of Biology and Technology - Instituto de Tecnologia do Paraná (Tecpar) |
repository.mail.fl_str_mv |
babt@tecpar.br||babt@tecpar.br |
_version_ |
1750318271029051392 |