Development of an enzyme immunoassay for poliovirus antigens
Autor(a) principal: | |
---|---|
Data de Publicação: | 2007 |
Outros Autores: | , , , |
Tipo de documento: | Artigo |
Idioma: | eng |
Título da fonte: | Brazilian Archives of Biology and Technology |
Texto Completo: | http://old.scielo.br/scielo.php?script=sci_arttext&pid=S1516-89132007000100005 |
Resumo: | An indirect solid-phase enzyme immunoassay (EIA) was developed for the detection of poliovirus antigen. Virus antigen was obtained in LLC-MK2 cell cultures and used to prepare antibodies in rabbit and guinea pig. Antibodies were evaluated by double immunodiffusion and neutralization test. Optimal concentrations of guinea pig and rabbit immunoglobulins were determined by checkerboard titration. Microtitre plates were coated with 15.0 µg/ml guinea pig anti-polio immunoglobulin and rabbit anti-polio immunoglobulin at the concentration of 7.94 µg/ml was used as detecting antibody. The standard curve with eight different antigen concentrations in eight replicates resulted in a coefficient of variation (CV) between 2.1% to 7.8%. The dose-response relationship was determined by simple linear regression with a coefficient of correlation (R²) equal to 96.4%. The assay detected a minimum of 2.3 µg/ml poliovirus antigen. |
id |
TECPAR-1_82dd920784c68ca4d2e9975c08ba4028 |
---|---|
oai_identifier_str |
oai:scielo:S1516-89132007000100005 |
network_acronym_str |
TECPAR-1 |
network_name_str |
Brazilian Archives of Biology and Technology |
repository_id_str |
|
spelling |
Development of an enzyme immunoassay for poliovirus antigensEnzyme immunoassayPoliovirus antigenAn indirect solid-phase enzyme immunoassay (EIA) was developed for the detection of poliovirus antigen. Virus antigen was obtained in LLC-MK2 cell cultures and used to prepare antibodies in rabbit and guinea pig. Antibodies were evaluated by double immunodiffusion and neutralization test. Optimal concentrations of guinea pig and rabbit immunoglobulins were determined by checkerboard titration. Microtitre plates were coated with 15.0 µg/ml guinea pig anti-polio immunoglobulin and rabbit anti-polio immunoglobulin at the concentration of 7.94 µg/ml was used as detecting antibody. The standard curve with eight different antigen concentrations in eight replicates resulted in a coefficient of variation (CV) between 2.1% to 7.8%. The dose-response relationship was determined by simple linear regression with a coefficient of correlation (R²) equal to 96.4%. The assay detected a minimum of 2.3 µg/ml poliovirus antigen.Instituto de Tecnologia do Paraná - Tecpar2007-01-01info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersiontext/htmlhttp://old.scielo.br/scielo.php?script=sci_arttext&pid=S1516-89132007000100005Brazilian Archives of Biology and Technology v.50 n.1 2007reponame:Brazilian Archives of Biology and Technologyinstname:Instituto de Tecnologia do Paraná (Tecpar)instacron:TECPAR10.1590/S1516-89132007000100005info:eu-repo/semantics/openAccessHashimoto,NewtonBenati,Fabrício JoséLauretti,FlávioLinhares,Rosa Elisa CarvalhoNozawa,Carlos Mitihikoeng2007-05-30T00:00:00Zoai:scielo:S1516-89132007000100005Revistahttps://www.scielo.br/j/babt/https://old.scielo.br/oai/scielo-oai.phpbabt@tecpar.br||babt@tecpar.br1678-43241516-8913opendoar:2007-05-30T00:00Brazilian Archives of Biology and Technology - Instituto de Tecnologia do Paraná (Tecpar)false |
dc.title.none.fl_str_mv |
Development of an enzyme immunoassay for poliovirus antigens |
title |
Development of an enzyme immunoassay for poliovirus antigens |
spellingShingle |
Development of an enzyme immunoassay for poliovirus antigens Hashimoto,Newton Enzyme immunoassay Poliovirus antigen |
title_short |
Development of an enzyme immunoassay for poliovirus antigens |
title_full |
Development of an enzyme immunoassay for poliovirus antigens |
title_fullStr |
Development of an enzyme immunoassay for poliovirus antigens |
title_full_unstemmed |
Development of an enzyme immunoassay for poliovirus antigens |
title_sort |
Development of an enzyme immunoassay for poliovirus antigens |
author |
Hashimoto,Newton |
author_facet |
Hashimoto,Newton Benati,Fabrício José Lauretti,Flávio Linhares,Rosa Elisa Carvalho Nozawa,Carlos Mitihiko |
author_role |
author |
author2 |
Benati,Fabrício José Lauretti,Flávio Linhares,Rosa Elisa Carvalho Nozawa,Carlos Mitihiko |
author2_role |
author author author author |
dc.contributor.author.fl_str_mv |
Hashimoto,Newton Benati,Fabrício José Lauretti,Flávio Linhares,Rosa Elisa Carvalho Nozawa,Carlos Mitihiko |
dc.subject.por.fl_str_mv |
Enzyme immunoassay Poliovirus antigen |
topic |
Enzyme immunoassay Poliovirus antigen |
description |
An indirect solid-phase enzyme immunoassay (EIA) was developed for the detection of poliovirus antigen. Virus antigen was obtained in LLC-MK2 cell cultures and used to prepare antibodies in rabbit and guinea pig. Antibodies were evaluated by double immunodiffusion and neutralization test. Optimal concentrations of guinea pig and rabbit immunoglobulins were determined by checkerboard titration. Microtitre plates were coated with 15.0 µg/ml guinea pig anti-polio immunoglobulin and rabbit anti-polio immunoglobulin at the concentration of 7.94 µg/ml was used as detecting antibody. The standard curve with eight different antigen concentrations in eight replicates resulted in a coefficient of variation (CV) between 2.1% to 7.8%. The dose-response relationship was determined by simple linear regression with a coefficient of correlation (R²) equal to 96.4%. The assay detected a minimum of 2.3 µg/ml poliovirus antigen. |
publishDate |
2007 |
dc.date.none.fl_str_mv |
2007-01-01 |
dc.type.driver.fl_str_mv |
info:eu-repo/semantics/article |
dc.type.status.fl_str_mv |
info:eu-repo/semantics/publishedVersion |
format |
article |
status_str |
publishedVersion |
dc.identifier.uri.fl_str_mv |
http://old.scielo.br/scielo.php?script=sci_arttext&pid=S1516-89132007000100005 |
url |
http://old.scielo.br/scielo.php?script=sci_arttext&pid=S1516-89132007000100005 |
dc.language.iso.fl_str_mv |
eng |
language |
eng |
dc.relation.none.fl_str_mv |
10.1590/S1516-89132007000100005 |
dc.rights.driver.fl_str_mv |
info:eu-repo/semantics/openAccess |
eu_rights_str_mv |
openAccess |
dc.format.none.fl_str_mv |
text/html |
dc.publisher.none.fl_str_mv |
Instituto de Tecnologia do Paraná - Tecpar |
publisher.none.fl_str_mv |
Instituto de Tecnologia do Paraná - Tecpar |
dc.source.none.fl_str_mv |
Brazilian Archives of Biology and Technology v.50 n.1 2007 reponame:Brazilian Archives of Biology and Technology instname:Instituto de Tecnologia do Paraná (Tecpar) instacron:TECPAR |
instname_str |
Instituto de Tecnologia do Paraná (Tecpar) |
instacron_str |
TECPAR |
institution |
TECPAR |
reponame_str |
Brazilian Archives of Biology and Technology |
collection |
Brazilian Archives of Biology and Technology |
repository.name.fl_str_mv |
Brazilian Archives of Biology and Technology - Instituto de Tecnologia do Paraná (Tecpar) |
repository.mail.fl_str_mv |
babt@tecpar.br||babt@tecpar.br |
_version_ |
1750318271448481792 |