Evaluation of a Combined System Based on an Upflow Anaerobic Sludge Blanket Reactor (UASB) and Shallow Polishing Pond (SPP) for Textile Effluent Treatment

Detalhes bibliográficos
Autor(a) principal: Bahia,Marina
Data de Publicação: 2020
Outros Autores: Borges,Tatiane Aparecida, Passos,Fabiana, Aquino,Sérgio Francisco de, Silva,Silvana de Queiroz
Tipo de documento: Artigo
Idioma: eng
Título da fonte: Brazilian Archives of Biology and Technology
Texto Completo: http://old.scielo.br/scielo.php?script=sci_arttext&pid=S1516-89132020000100708
Resumo: Abstract Color removal from textile effluents was evaluated using a laboratory-combined process based on an upflow anaerobic sludge blanket (UASB) reactor followed by a shallow polishing pond (SPP). The anaerobic reactor was fed with a real textile effluent, diluted 10-times in a 350 mg/L solution of pre-treated residual yeast extract from a brewery industry as nutrient source. The parameters color, COD, N-NH3 and toxicity were monitored throughout 45 days of operation. According to the results, decolorization and COD removal were highest in the anaerobic step, whereas the effluent was polished in the SPP unit. The overall efficiency of the complete UASB-SPP system for COD and color were 88 and 62%, respectively. Moreover, the N-NH3 generated by the residual yeast extract ammonification was below 5 mg/L for the final effluent. Finally, no toxicity was detected after the treatment steps, as shown by the Vibrio fischeri microscale assay.
id TECPAR-1_e33477815b1532c2eee43f7fb78072fb
oai_identifier_str oai:scielo:S1516-89132020000100708
network_acronym_str TECPAR-1
network_name_str Brazilian Archives of Biology and Technology
repository_id_str
spelling Evaluation of a Combined System Based on an Upflow Anaerobic Sludge Blanket Reactor (UASB) and Shallow Polishing Pond (SPP) for Textile Effluent Treatmentanaerobic-aerobic treatmentresidual yeasttextile effluent toxicityVibrio fischeriAbstract Color removal from textile effluents was evaluated using a laboratory-combined process based on an upflow anaerobic sludge blanket (UASB) reactor followed by a shallow polishing pond (SPP). The anaerobic reactor was fed with a real textile effluent, diluted 10-times in a 350 mg/L solution of pre-treated residual yeast extract from a brewery industry as nutrient source. The parameters color, COD, N-NH3 and toxicity were monitored throughout 45 days of operation. According to the results, decolorization and COD removal were highest in the anaerobic step, whereas the effluent was polished in the SPP unit. The overall efficiency of the complete UASB-SPP system for COD and color were 88 and 62%, respectively. Moreover, the N-NH3 generated by the residual yeast extract ammonification was below 5 mg/L for the final effluent. Finally, no toxicity was detected after the treatment steps, as shown by the Vibrio fischeri microscale assay.Instituto de Tecnologia do Paraná - Tecpar2020-01-01info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersiontext/htmlhttp://old.scielo.br/scielo.php?script=sci_arttext&pid=S1516-89132020000100708Brazilian Archives of Biology and Technology v.63 2020reponame:Brazilian Archives of Biology and Technologyinstname:Instituto de Tecnologia do Paraná (Tecpar)instacron:TECPAR10.1590/1678-4324-2020180130info:eu-repo/semantics/openAccessBahia,MarinaBorges,Tatiane AparecidaPassos,FabianaAquino,Sérgio Francisco deSilva,Silvana de Queirozeng2020-09-28T00:00:00Zoai:scielo:S1516-89132020000100708Revistahttps://www.scielo.br/j/babt/https://old.scielo.br/oai/scielo-oai.phpbabt@tecpar.br||babt@tecpar.br1678-43241516-8913opendoar:2020-09-28T00:00Brazilian Archives of Biology and Technology - Instituto de Tecnologia do Paraná (Tecpar)false
dc.title.none.fl_str_mv Evaluation of a Combined System Based on an Upflow Anaerobic Sludge Blanket Reactor (UASB) and Shallow Polishing Pond (SPP) for Textile Effluent Treatment
title Evaluation of a Combined System Based on an Upflow Anaerobic Sludge Blanket Reactor (UASB) and Shallow Polishing Pond (SPP) for Textile Effluent Treatment
spellingShingle Evaluation of a Combined System Based on an Upflow Anaerobic Sludge Blanket Reactor (UASB) and Shallow Polishing Pond (SPP) for Textile Effluent Treatment
Bahia,Marina
anaerobic-aerobic treatment
residual yeast
textile effluent toxicity
Vibrio fischeri
title_short Evaluation of a Combined System Based on an Upflow Anaerobic Sludge Blanket Reactor (UASB) and Shallow Polishing Pond (SPP) for Textile Effluent Treatment
title_full Evaluation of a Combined System Based on an Upflow Anaerobic Sludge Blanket Reactor (UASB) and Shallow Polishing Pond (SPP) for Textile Effluent Treatment
title_fullStr Evaluation of a Combined System Based on an Upflow Anaerobic Sludge Blanket Reactor (UASB) and Shallow Polishing Pond (SPP) for Textile Effluent Treatment
title_full_unstemmed Evaluation of a Combined System Based on an Upflow Anaerobic Sludge Blanket Reactor (UASB) and Shallow Polishing Pond (SPP) for Textile Effluent Treatment
title_sort Evaluation of a Combined System Based on an Upflow Anaerobic Sludge Blanket Reactor (UASB) and Shallow Polishing Pond (SPP) for Textile Effluent Treatment
author Bahia,Marina
author_facet Bahia,Marina
Borges,Tatiane Aparecida
Passos,Fabiana
Aquino,Sérgio Francisco de
Silva,Silvana de Queiroz
author_role author
author2 Borges,Tatiane Aparecida
Passos,Fabiana
Aquino,Sérgio Francisco de
Silva,Silvana de Queiroz
author2_role author
author
author
author
dc.contributor.author.fl_str_mv Bahia,Marina
Borges,Tatiane Aparecida
Passos,Fabiana
Aquino,Sérgio Francisco de
Silva,Silvana de Queiroz
dc.subject.por.fl_str_mv anaerobic-aerobic treatment
residual yeast
textile effluent toxicity
Vibrio fischeri
topic anaerobic-aerobic treatment
residual yeast
textile effluent toxicity
Vibrio fischeri
description Abstract Color removal from textile effluents was evaluated using a laboratory-combined process based on an upflow anaerobic sludge blanket (UASB) reactor followed by a shallow polishing pond (SPP). The anaerobic reactor was fed with a real textile effluent, diluted 10-times in a 350 mg/L solution of pre-treated residual yeast extract from a brewery industry as nutrient source. The parameters color, COD, N-NH3 and toxicity were monitored throughout 45 days of operation. According to the results, decolorization and COD removal were highest in the anaerobic step, whereas the effluent was polished in the SPP unit. The overall efficiency of the complete UASB-SPP system for COD and color were 88 and 62%, respectively. Moreover, the N-NH3 generated by the residual yeast extract ammonification was below 5 mg/L for the final effluent. Finally, no toxicity was detected after the treatment steps, as shown by the Vibrio fischeri microscale assay.
publishDate 2020
dc.date.none.fl_str_mv 2020-01-01
dc.type.driver.fl_str_mv info:eu-repo/semantics/article
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
format article
status_str publishedVersion
dc.identifier.uri.fl_str_mv http://old.scielo.br/scielo.php?script=sci_arttext&pid=S1516-89132020000100708
url http://old.scielo.br/scielo.php?script=sci_arttext&pid=S1516-89132020000100708
dc.language.iso.fl_str_mv eng
language eng
dc.relation.none.fl_str_mv 10.1590/1678-4324-2020180130
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv text/html
dc.publisher.none.fl_str_mv Instituto de Tecnologia do Paraná - Tecpar
publisher.none.fl_str_mv Instituto de Tecnologia do Paraná - Tecpar
dc.source.none.fl_str_mv Brazilian Archives of Biology and Technology v.63 2020
reponame:Brazilian Archives of Biology and Technology
instname:Instituto de Tecnologia do Paraná (Tecpar)
instacron:TECPAR
instname_str Instituto de Tecnologia do Paraná (Tecpar)
instacron_str TECPAR
institution TECPAR
reponame_str Brazilian Archives of Biology and Technology
collection Brazilian Archives of Biology and Technology
repository.name.fl_str_mv Brazilian Archives of Biology and Technology - Instituto de Tecnologia do Paraná (Tecpar)
repository.mail.fl_str_mv babt@tecpar.br||babt@tecpar.br
_version_ 1750318280103428096