Evaluation of reproductibility and detection limit of CaSO4: dy radiation detectors
Autor(a) principal: | |
---|---|
Data de Publicação: | 2006 |
Outros Autores: | , |
Tipo de documento: | Artigo |
Idioma: | eng |
Título da fonte: | Brazilian Archives of Biology and Technology |
Texto Completo: | http://old.scielo.br/scielo.php?script=sci_arttext&pid=S1516-89132006000200009 |
Resumo: | Measurement response of thermoluminescent dosimeter, TLD, used by workers or placed at positions where gamma radiation field could be in action affecting biological tissues, should be completely characterized, in order to achieve the radiation quantity with precision and confidence. Among the evaluations concerned to its characterization, the detector reproductibility is of fundamental importance, because detectors present inside the TLD will be used many times in routine. Reproductibility is studied by repeated exposure to the same radiation field. The minimum detection limit is another important characteristics of a TLD. In this work evaluations of reproductibility and minimum detection are presented, for dosimeters produced at IPEN. |
id |
TECPAR-1_eb212f0580c5eb15295e5ffb1ac46f70 |
---|---|
oai_identifier_str |
oai:scielo:S1516-89132006000200009 |
network_acronym_str |
TECPAR-1 |
network_name_str |
Brazilian Archives of Biology and Technology |
repository_id_str |
|
spelling |
Evaluation of reproductibility and detection limit of CaSO4: dy radiation detectorsDetector selectionpersonal dosimetryenvironmental dosimetryMeasurement response of thermoluminescent dosimeter, TLD, used by workers or placed at positions where gamma radiation field could be in action affecting biological tissues, should be completely characterized, in order to achieve the radiation quantity with precision and confidence. Among the evaluations concerned to its characterization, the detector reproductibility is of fundamental importance, because detectors present inside the TLD will be used many times in routine. Reproductibility is studied by repeated exposure to the same radiation field. The minimum detection limit is another important characteristics of a TLD. In this work evaluations of reproductibility and minimum detection are presented, for dosimeters produced at IPEN.Instituto de Tecnologia do Paraná - Tecpar2006-01-01info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersiontext/htmlhttp://old.scielo.br/scielo.php?script=sci_arttext&pid=S1516-89132006000200009Brazilian Archives of Biology and Technology v.49 n.spe 2006reponame:Brazilian Archives of Biology and Technologyinstname:Instituto de Tecnologia do Paraná (Tecpar)instacron:TECPAR10.1590/S1516-89132006000200009info:eu-repo/semantics/openAccessManzoli,José EduardoCampos,Vicente de Paulo deDoi,Mirian Saorieng2006-03-30T00:00:00Zoai:scielo:S1516-89132006000200009Revistahttps://www.scielo.br/j/babt/https://old.scielo.br/oai/scielo-oai.phpbabt@tecpar.br||babt@tecpar.br1678-43241516-8913opendoar:2006-03-30T00:00Brazilian Archives of Biology and Technology - Instituto de Tecnologia do Paraná (Tecpar)false |
dc.title.none.fl_str_mv |
Evaluation of reproductibility and detection limit of CaSO4: dy radiation detectors |
title |
Evaluation of reproductibility and detection limit of CaSO4: dy radiation detectors |
spellingShingle |
Evaluation of reproductibility and detection limit of CaSO4: dy radiation detectors Manzoli,José Eduardo Detector selection personal dosimetry environmental dosimetry |
title_short |
Evaluation of reproductibility and detection limit of CaSO4: dy radiation detectors |
title_full |
Evaluation of reproductibility and detection limit of CaSO4: dy radiation detectors |
title_fullStr |
Evaluation of reproductibility and detection limit of CaSO4: dy radiation detectors |
title_full_unstemmed |
Evaluation of reproductibility and detection limit of CaSO4: dy radiation detectors |
title_sort |
Evaluation of reproductibility and detection limit of CaSO4: dy radiation detectors |
author |
Manzoli,José Eduardo |
author_facet |
Manzoli,José Eduardo Campos,Vicente de Paulo de Doi,Mirian Saori |
author_role |
author |
author2 |
Campos,Vicente de Paulo de Doi,Mirian Saori |
author2_role |
author author |
dc.contributor.author.fl_str_mv |
Manzoli,José Eduardo Campos,Vicente de Paulo de Doi,Mirian Saori |
dc.subject.por.fl_str_mv |
Detector selection personal dosimetry environmental dosimetry |
topic |
Detector selection personal dosimetry environmental dosimetry |
description |
Measurement response of thermoluminescent dosimeter, TLD, used by workers or placed at positions where gamma radiation field could be in action affecting biological tissues, should be completely characterized, in order to achieve the radiation quantity with precision and confidence. Among the evaluations concerned to its characterization, the detector reproductibility is of fundamental importance, because detectors present inside the TLD will be used many times in routine. Reproductibility is studied by repeated exposure to the same radiation field. The minimum detection limit is another important characteristics of a TLD. In this work evaluations of reproductibility and minimum detection are presented, for dosimeters produced at IPEN. |
publishDate |
2006 |
dc.date.none.fl_str_mv |
2006-01-01 |
dc.type.driver.fl_str_mv |
info:eu-repo/semantics/article |
dc.type.status.fl_str_mv |
info:eu-repo/semantics/publishedVersion |
format |
article |
status_str |
publishedVersion |
dc.identifier.uri.fl_str_mv |
http://old.scielo.br/scielo.php?script=sci_arttext&pid=S1516-89132006000200009 |
url |
http://old.scielo.br/scielo.php?script=sci_arttext&pid=S1516-89132006000200009 |
dc.language.iso.fl_str_mv |
eng |
language |
eng |
dc.relation.none.fl_str_mv |
10.1590/S1516-89132006000200009 |
dc.rights.driver.fl_str_mv |
info:eu-repo/semantics/openAccess |
eu_rights_str_mv |
openAccess |
dc.format.none.fl_str_mv |
text/html |
dc.publisher.none.fl_str_mv |
Instituto de Tecnologia do Paraná - Tecpar |
publisher.none.fl_str_mv |
Instituto de Tecnologia do Paraná - Tecpar |
dc.source.none.fl_str_mv |
Brazilian Archives of Biology and Technology v.49 n.spe 2006 reponame:Brazilian Archives of Biology and Technology instname:Instituto de Tecnologia do Paraná (Tecpar) instacron:TECPAR |
instname_str |
Instituto de Tecnologia do Paraná (Tecpar) |
instacron_str |
TECPAR |
institution |
TECPAR |
reponame_str |
Brazilian Archives of Biology and Technology |
collection |
Brazilian Archives of Biology and Technology |
repository.name.fl_str_mv |
Brazilian Archives of Biology and Technology - Instituto de Tecnologia do Paraná (Tecpar) |
repository.mail.fl_str_mv |
babt@tecpar.br||babt@tecpar.br |
_version_ |
1750318270770053120 |