Aplicação de dois modelos de balanço hídrico para estudo de camada de cobertura de aterro sanitário utilizando solo e Resíduo da Construção Civil (RCC)
Autor(a) principal: | |
---|---|
Data de Publicação: | 2016 |
Tipo de documento: | Dissertação |
Idioma: | por |
Título da fonte: | Biblioteca Digital de Teses e Dissertações da UEFS |
Texto Completo: | http://localhost:8080/tede/handle/tede/473 |
Resumo: | The water balance is an important aspect on development of a landfill project, and the choice of material for the cover layer will influence the generation of percolated liquids. Considering the composition and characteristics of cover layers, it becomes necessary the conventional material substitution. Therefore, this study compared the construction civil waste (CCW) to the soil from the university campus - UEFS in Feira de Santana/BA as used in evapotranspiration cover layer for landfill, using the water balance models Fenn et al. (1975) and São Mateus et al. (2012). The results showed that both materials have the same behavior for the Fenn et al. (1975) method, where the CCW generates less liquid than MSW to the ground. By the method of São Mateus et al. (2012), the CCW and the soil allow the passage of water to the MSW in different behaviors, and the soil promoted greater liquid infiltration, about 95.5% higher than the CCW. When the methods were compared, São Mateus et al. (2012) presented higher water infiltration to the MSW in the simulation with the soil, in relation to the method of Fenn et al. (1975), and smaller with the CCW, this occurs due to the distinction of the input parameters for the materials, highlighting the influence of the permeability coefficient in the water balance. |
id |
UEFS_3874fec9e43c5e98e3eaf1249a7cece9 |
---|---|
oai_identifier_str |
oai:tede2.uefs.br:8080:tede/473 |
network_acronym_str |
UEFS |
network_name_str |
Biblioteca Digital de Teses e Dissertações da UEFS |
repository_id_str |
|
spelling |
São Mateus, Maria do Socorro Costa3614551350004729329503http://lattes.cnpq.br/5937194312429465Rios, Daiane do Carmo2017-07-12T01:22:06Z2016-09-14RIOS, Daiane do Carmo. Aplicação de dois modelos de balanço hídrico para estudo de Camada de cobertura de aterro sanitário utilizando solo e Resíduo da construção civil (RCC). 2016. 138 f. Dissertação (Mestrado em Engenharia Civil e Ambiental)- Universidade Estadual de Feira de Santana, Feira de Santana, 2016.http://localhost:8080/tede/handle/tede/473The water balance is an important aspect on development of a landfill project, and the choice of material for the cover layer will influence the generation of percolated liquids. Considering the composition and characteristics of cover layers, it becomes necessary the conventional material substitution. Therefore, this study compared the construction civil waste (CCW) to the soil from the university campus - UEFS in Feira de Santana/BA as used in evapotranspiration cover layer for landfill, using the water balance models Fenn et al. (1975) and São Mateus et al. (2012). The results showed that both materials have the same behavior for the Fenn et al. (1975) method, where the CCW generates less liquid than MSW to the ground. By the method of São Mateus et al. (2012), the CCW and the soil allow the passage of water to the MSW in different behaviors, and the soil promoted greater liquid infiltration, about 95.5% higher than the CCW. When the methods were compared, São Mateus et al. (2012) presented higher water infiltration to the MSW in the simulation with the soil, in relation to the method of Fenn et al. (1975), and smaller with the CCW, this occurs due to the distinction of the input parameters for the materials, highlighting the influence of the permeability coefficient in the water balance.O balanço hídrico é parte importante no processo de elaboração de um projeto de aterro sanitário, visto que a escolha do material para a camada de cobertura influenciará na geração de líquidos percolados. Tendo em vista a necessidade da utilização de materiais para a composição das diversas camadas dos sistemas de cobertura, torna-se indispensável o estudo de materiais alternativos para a substituição dos materiais usados originalmente. Para tanto, este trabalho comparou o resíduo da construção civil (RCC) com o solo do campus universitário da UEFS em Feira de Santana/BA utilizados como camada de cobertura para aterro sanitário, utilizando os modelos de balanço hídrico de Fenn et al. (1975) e São Mateus et al. (2012). Os resultados mostraram que, pelo método de Fenn et al. (1975), ambos os materiais possuem comportamento semelhante, sendo que o RCC infiltrou menor quantidade de água para o resíduo sólido urbano (RSU) do que o solo. Pelo método de São Mateus et al. (2012), o RCC e o solo permitem a passagem de água para o RSU em comportamentos distintos, sendo que o solo promoveu maior infiltração de líquidos, cerca de 95,5% maior do que o RCC. Quando comparados os métodos, São Mateus et al. (2012) apresentou maior infiltração de água para o RSU na simulação com o solo, com relação ao método de Fenn et al. (1975), e menor com o RCC, isto ocorre devido à distinção dos parâmetros de entrada para os materiais, destacando-se a influência do coeficiente de permeabilidade no balanço hídrico.Submitted by Ricardo Cedraz Duque Moliterno (ricardo.moliterno@uefs.br) on 2017-07-12T01:22:06Z No. of bitstreams: 1 Dissertação Daiane do Carmo.pdf: 4697687 bytes, checksum: a37b7f9d37bd854f2fb6862074c46fd4 (MD5)Made available in DSpace on 2017-07-12T01:22:06Z (GMT). No. of bitstreams: 1 Dissertação Daiane do Carmo.pdf: 4697687 bytes, checksum: a37b7f9d37bd854f2fb6862074c46fd4 (MD5) Previous issue date: 2016-09-14Fundação de Amparo à Pesquisa do Estado da Bahia - FAPEBapplication/pdfporUniversidade Estadual de Feira de SantanaMestrado em Engenharia Civil e AmbientalUEFSBrasilDEPARTAMENTO DE CIÊNCIAS EXATASBalanço hídricoCamada de cobertura finalAterro sanitárioResíduo da construção civilWater balanceFinal cover layerLandfillConstruction civil wasteSANEAMENTO AMBIENTAL::CONTROLE DA POLUICAOAplicação de dois modelos de balanço hídrico para estudo de camada de cobertura de aterro sanitário utilizando solo e Resíduo da Construção Civil (RCC)info:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/masterThesis-1930936678452160642600600600600-5486832816611506211-5097413046757708096-8233071094704392586info:eu-repo/semantics/openAccessreponame:Biblioteca Digital de Teses e Dissertações da UEFSinstname:Universidade Estadual de Feira de Santana (UEFS)instacron:UEFSORIGINALDissertação Daiane do Carmo.pdfDissertação Daiane do Carmo.pdfapplication/pdf4697687http://tede2.uefs.br:8080/bitstream/tede/473/2/Disserta%C3%A7%C3%A3o+Daiane+do+Carmo.pdfa37b7f9d37bd854f2fb6862074c46fd4MD52LICENSElicense.txtlicense.txttext/plain; charset=utf-82089http://tede2.uefs.br:8080/bitstream/tede/473/1/license.txt7b5ba3d2445355f386edab96125d42b7MD51tede/4732023-01-27 09:41:25.967oai:tede2.uefs.br:8080:tede/473Tk9UQTogQ09MT1FVRSBBUVVJIEEgU1VBIFBSP1BSSUEgTElDRU4/QQpFc3RhIGxpY2VuP2EgZGUgZXhlbXBsbyA/IGZvcm5lY2lkYSBhcGVuYXMgcGFyYSBmaW5zIGluZm9ybWF0aXZvcy4KCkxJQ0VOP0EgREUgRElTVFJJQlVJPz9PIE4/Ty1FWENMVVNJVkEKCkNvbSBhIGFwcmVzZW50YT8/byBkZXN0YSBsaWNlbj9hLCB2b2M/IChvIGF1dG9yIChlcykgb3UgbyB0aXR1bGFyIGRvcyBkaXJlaXRvcyBkZSBhdXRvcikgY29uY2VkZSA/IFVuaXZlcnNpZGFkZSAKWFhYIChTaWdsYSBkYSBVbml2ZXJzaWRhZGUpIG8gZGlyZWl0byBuP28tZXhjbHVzaXZvIGRlIHJlcHJvZHV6aXIsICB0cmFkdXppciAoY29uZm9ybWUgZGVmaW5pZG8gYWJhaXhvKSwgZS9vdSAKZGlzdHJpYnVpciBhIHN1YSB0ZXNlIG91IGRpc3NlcnRhPz9vIChpbmNsdWluZG8gbyByZXN1bW8pIHBvciB0b2RvIG8gbXVuZG8gbm8gZm9ybWF0byBpbXByZXNzbyBlIGVsZXRyP25pY28gZSAKZW0gcXVhbHF1ZXIgbWVpbywgaW5jbHVpbmRvIG9zIGZvcm1hdG9zID91ZGlvIG91IHY/ZGVvLgoKVm9jPyBjb25jb3JkYSBxdWUgYSBTaWdsYSBkZSBVbml2ZXJzaWRhZGUgcG9kZSwgc2VtIGFsdGVyYXIgbyBjb250ZT9kbywgdHJhbnNwb3IgYSBzdWEgdGVzZSBvdSBkaXNzZXJ0YT8/byAKcGFyYSBxdWFscXVlciBtZWlvIG91IGZvcm1hdG8gcGFyYSBmaW5zIGRlIHByZXNlcnZhPz9vLgoKVm9jPyB0YW1iP20gY29uY29yZGEgcXVlIGEgU2lnbGEgZGUgVW5pdmVyc2lkYWRlIHBvZGUgbWFudGVyIG1haXMgZGUgdW1hIGM/cGlhIGEgc3VhIHRlc2Ugb3UgCmRpc3NlcnRhPz9vIHBhcmEgZmlucyBkZSBzZWd1cmFuP2EsIGJhY2stdXAgZSBwcmVzZXJ2YT8/by4KClZvYz8gZGVjbGFyYSBxdWUgYSBzdWEgdGVzZSBvdSBkaXNzZXJ0YT8/byA/IG9yaWdpbmFsIGUgcXVlIHZvYz8gdGVtIG8gcG9kZXIgZGUgY29uY2VkZXIgb3MgZGlyZWl0b3MgY29udGlkb3MgCm5lc3RhIGxpY2VuP2EuIFZvYz8gdGFtYj9tIGRlY2xhcmEgcXVlIG8gZGVwP3NpdG8gZGEgc3VhIHRlc2Ugb3UgZGlzc2VydGE/P28gbj9vLCBxdWUgc2VqYSBkZSBzZXUgCmNvbmhlY2ltZW50bywgaW5mcmluZ2UgZGlyZWl0b3MgYXV0b3JhaXMgZGUgbmluZ3U/bS4KCkNhc28gYSBzdWEgdGVzZSBvdSBkaXNzZXJ0YT8/byBjb250ZW5oYSBtYXRlcmlhbCBxdWUgdm9jPyBuP28gcG9zc3VpIGEgdGl0dWxhcmlkYWRlIGRvcyBkaXJlaXRvcyBhdXRvcmFpcywgdm9jPyAKZGVjbGFyYSBxdWUgb2J0ZXZlIGEgcGVybWlzcz9vIGlycmVzdHJpdGEgZG8gZGV0ZW50b3IgZG9zIGRpcmVpdG9zIGF1dG9yYWlzIHBhcmEgY29uY2VkZXIgPyBTaWdsYSBkZSBVbml2ZXJzaWRhZGUgCm9zIGRpcmVpdG9zIGFwcmVzZW50YWRvcyBuZXN0YSBsaWNlbj9hLCBlIHF1ZSBlc3NlIG1hdGVyaWFsIGRlIHByb3ByaWVkYWRlIGRlIHRlcmNlaXJvcyBlc3Q/IGNsYXJhbWVudGUgCmlkZW50aWZpY2FkbyBlIHJlY29uaGVjaWRvIG5vIHRleHRvIG91IG5vIGNvbnRlP2RvIGRhIHRlc2Ugb3UgZGlzc2VydGE/P28gb3JhIGRlcG9zaXRhZGEuCgpDQVNPIEEgVEVTRSBPVSBESVNTRVJUQT8/TyBPUkEgREVQT1NJVEFEQSBURU5IQSBTSURPIFJFU1VMVEFETyBERSBVTSBQQVRST0M/TklPIE9VIApBUE9JTyBERSBVTUEgQUc/TkNJQSBERSBGT01FTlRPIE9VIE9VVFJPIE9SR0FOSVNNTyBRVUUgTj9PIFNFSkEgQSBTSUdMQSBERSAKVU5JVkVSU0lEQURFLCBWT0M/IERFQ0xBUkEgUVVFIFJFU1BFSVRPVSBUT0RPUyBFIFFVQUlTUVVFUiBESVJFSVRPUyBERSBSRVZJUz9PIENPTU8gClRBTUI/TSBBUyBERU1BSVMgT0JSSUdBPz9FUyBFWElHSURBUyBQT1IgQ09OVFJBVE8gT1UgQUNPUkRPLgoKQSBTaWdsYSBkZSBVbml2ZXJzaWRhZGUgc2UgY29tcHJvbWV0ZSBhIGlkZW50aWZpY2FyIGNsYXJhbWVudGUgbyBzZXUgbm9tZSAocykgb3UgbyhzKSBub21lKHMpIGRvKHMpIApkZXRlbnRvcihlcykgZG9zIGRpcmVpdG9zIGF1dG9yYWlzIGRhIHRlc2Ugb3UgZGlzc2VydGE/P28sIGUgbj9vIGZhcj8gcXVhbHF1ZXIgYWx0ZXJhPz9vLCBhbD9tIGRhcXVlbGFzIApjb25jZWRpZGFzIHBvciBlc3RhIGxpY2VuP2EuCg==Biblioteca Digital de Teses e Dissertaçõeshttp://tede2.uefs.br:8080/PUBhttp://tede2.uefs.br:8080/oai/requestbcuefs@uefs.br|| bcref@uefs.br||bcuefs@uefs.bropendoar:2023-01-27T12:41:25Biblioteca Digital de Teses e Dissertações da UEFS - Universidade Estadual de Feira de Santana (UEFS)false |
dc.title.por.fl_str_mv |
Aplicação de dois modelos de balanço hídrico para estudo de camada de cobertura de aterro sanitário utilizando solo e Resíduo da Construção Civil (RCC) |
title |
Aplicação de dois modelos de balanço hídrico para estudo de camada de cobertura de aterro sanitário utilizando solo e Resíduo da Construção Civil (RCC) |
spellingShingle |
Aplicação de dois modelos de balanço hídrico para estudo de camada de cobertura de aterro sanitário utilizando solo e Resíduo da Construção Civil (RCC) Rios, Daiane do Carmo Balanço hídrico Camada de cobertura final Aterro sanitário Resíduo da construção civil Water balance Final cover layer Landfill Construction civil waste SANEAMENTO AMBIENTAL::CONTROLE DA POLUICAO |
title_short |
Aplicação de dois modelos de balanço hídrico para estudo de camada de cobertura de aterro sanitário utilizando solo e Resíduo da Construção Civil (RCC) |
title_full |
Aplicação de dois modelos de balanço hídrico para estudo de camada de cobertura de aterro sanitário utilizando solo e Resíduo da Construção Civil (RCC) |
title_fullStr |
Aplicação de dois modelos de balanço hídrico para estudo de camada de cobertura de aterro sanitário utilizando solo e Resíduo da Construção Civil (RCC) |
title_full_unstemmed |
Aplicação de dois modelos de balanço hídrico para estudo de camada de cobertura de aterro sanitário utilizando solo e Resíduo da Construção Civil (RCC) |
title_sort |
Aplicação de dois modelos de balanço hídrico para estudo de camada de cobertura de aterro sanitário utilizando solo e Resíduo da Construção Civil (RCC) |
author |
Rios, Daiane do Carmo |
author_facet |
Rios, Daiane do Carmo |
author_role |
author |
dc.contributor.advisor1.fl_str_mv |
São Mateus, Maria do Socorro Costa |
dc.contributor.advisor1ID.fl_str_mv |
36145513500 |
dc.contributor.authorID.fl_str_mv |
04729329503 |
dc.contributor.authorLattes.fl_str_mv |
http://lattes.cnpq.br/5937194312429465 |
dc.contributor.author.fl_str_mv |
Rios, Daiane do Carmo |
contributor_str_mv |
São Mateus, Maria do Socorro Costa |
dc.subject.por.fl_str_mv |
Balanço hídrico Camada de cobertura final Aterro sanitário Resíduo da construção civil |
topic |
Balanço hídrico Camada de cobertura final Aterro sanitário Resíduo da construção civil Water balance Final cover layer Landfill Construction civil waste SANEAMENTO AMBIENTAL::CONTROLE DA POLUICAO |
dc.subject.eng.fl_str_mv |
Water balance Final cover layer Landfill Construction civil waste |
dc.subject.cnpq.fl_str_mv |
SANEAMENTO AMBIENTAL::CONTROLE DA POLUICAO |
description |
The water balance is an important aspect on development of a landfill project, and the choice of material for the cover layer will influence the generation of percolated liquids. Considering the composition and characteristics of cover layers, it becomes necessary the conventional material substitution. Therefore, this study compared the construction civil waste (CCW) to the soil from the university campus - UEFS in Feira de Santana/BA as used in evapotranspiration cover layer for landfill, using the water balance models Fenn et al. (1975) and São Mateus et al. (2012). The results showed that both materials have the same behavior for the Fenn et al. (1975) method, where the CCW generates less liquid than MSW to the ground. By the method of São Mateus et al. (2012), the CCW and the soil allow the passage of water to the MSW in different behaviors, and the soil promoted greater liquid infiltration, about 95.5% higher than the CCW. When the methods were compared, São Mateus et al. (2012) presented higher water infiltration to the MSW in the simulation with the soil, in relation to the method of Fenn et al. (1975), and smaller with the CCW, this occurs due to the distinction of the input parameters for the materials, highlighting the influence of the permeability coefficient in the water balance. |
publishDate |
2016 |
dc.date.issued.fl_str_mv |
2016-09-14 |
dc.date.accessioned.fl_str_mv |
2017-07-12T01:22:06Z |
dc.type.status.fl_str_mv |
info:eu-repo/semantics/publishedVersion |
dc.type.driver.fl_str_mv |
info:eu-repo/semantics/masterThesis |
format |
masterThesis |
status_str |
publishedVersion |
dc.identifier.citation.fl_str_mv |
RIOS, Daiane do Carmo. Aplicação de dois modelos de balanço hídrico para estudo de Camada de cobertura de aterro sanitário utilizando solo e Resíduo da construção civil (RCC). 2016. 138 f. Dissertação (Mestrado em Engenharia Civil e Ambiental)- Universidade Estadual de Feira de Santana, Feira de Santana, 2016. |
dc.identifier.uri.fl_str_mv |
http://localhost:8080/tede/handle/tede/473 |
identifier_str_mv |
RIOS, Daiane do Carmo. Aplicação de dois modelos de balanço hídrico para estudo de Camada de cobertura de aterro sanitário utilizando solo e Resíduo da construção civil (RCC). 2016. 138 f. Dissertação (Mestrado em Engenharia Civil e Ambiental)- Universidade Estadual de Feira de Santana, Feira de Santana, 2016. |
url |
http://localhost:8080/tede/handle/tede/473 |
dc.language.iso.fl_str_mv |
por |
language |
por |
dc.relation.program.fl_str_mv |
-1930936678452160642 |
dc.relation.confidence.fl_str_mv |
600 600 600 600 |
dc.relation.department.fl_str_mv |
-5486832816611506211 |
dc.relation.cnpq.fl_str_mv |
-5097413046757708096 |
dc.relation.sponsorship.fl_str_mv |
-8233071094704392586 |
dc.rights.driver.fl_str_mv |
info:eu-repo/semantics/openAccess |
eu_rights_str_mv |
openAccess |
dc.format.none.fl_str_mv |
application/pdf |
dc.publisher.none.fl_str_mv |
Universidade Estadual de Feira de Santana |
dc.publisher.program.fl_str_mv |
Mestrado em Engenharia Civil e Ambiental |
dc.publisher.initials.fl_str_mv |
UEFS |
dc.publisher.country.fl_str_mv |
Brasil |
dc.publisher.department.fl_str_mv |
DEPARTAMENTO DE CIÊNCIAS EXATAS |
publisher.none.fl_str_mv |
Universidade Estadual de Feira de Santana |
dc.source.none.fl_str_mv |
reponame:Biblioteca Digital de Teses e Dissertações da UEFS instname:Universidade Estadual de Feira de Santana (UEFS) instacron:UEFS |
instname_str |
Universidade Estadual de Feira de Santana (UEFS) |
instacron_str |
UEFS |
institution |
UEFS |
reponame_str |
Biblioteca Digital de Teses e Dissertações da UEFS |
collection |
Biblioteca Digital de Teses e Dissertações da UEFS |
bitstream.url.fl_str_mv |
http://tede2.uefs.br:8080/bitstream/tede/473/2/Disserta%C3%A7%C3%A3o+Daiane+do+Carmo.pdf http://tede2.uefs.br:8080/bitstream/tede/473/1/license.txt |
bitstream.checksum.fl_str_mv |
a37b7f9d37bd854f2fb6862074c46fd4 7b5ba3d2445355f386edab96125d42b7 |
bitstream.checksumAlgorithm.fl_str_mv |
MD5 MD5 |
repository.name.fl_str_mv |
Biblioteca Digital de Teses e Dissertações da UEFS - Universidade Estadual de Feira de Santana (UEFS) |
repository.mail.fl_str_mv |
bcuefs@uefs.br|| bcref@uefs.br||bcuefs@uefs.br |
_version_ |
1809288772460740608 |