Avaliação da influência da precipitação na rede de esgotamento sanitário do tipo separador absoluto - Feira de Santana - BA

Detalhes bibliográficos
Autor(a) principal: Santos, Quelle Rebouças dos
Data de Publicação: 2013
Tipo de documento: Dissertação
Idioma: por
Título da fonte: Biblioteca Digital de Teses e Dissertações da UEFS
Texto Completo: http://localhost:8080/tede/handle/tede/275
Resumo: The objective of this study was to evaluate the influence of stormwater on the energy consumption in the pump stations of the urban sewage system of Feira de Santana city. Data concerning the energy consumption in the pump stations, the water consumption in the area, and the precipitation rate were collected for the time period of 2008-2011. Statistical tests were performed by applying the Spearman’s rank correlation, the Anderson-Darling goodness-of-fit test, the Student’s test t, and the Ljung-Box test. The results showed that, regarding a potential influence of the effective precipitation rate on the energy consumption in the pumps, the correlation not significantly different from zero with a 95% confidence level for all the 19 pump stations. Similar results were obtained for the case of the potential influence of the public water consumption on the energy consumption in the pump stations. However, considering the total energy consumption in the pump stations, the correlation with the effective precipitation is significant, although weak (R=0.30). Thus, it was estimated that 9% of the total energy consumption in the pump stations is explained by the precipitation. By analyzing the correlation between the energy consumption of all the pump stations, it was found that the all possible correlations are weak, and only in 12% of the cases the correlation is significantly different from zero with a 95% confidence level. Moreover, such correlation was not observed in pumping stations installed in series. In addition, seasonality tests applied to the time series precipitation and water consumption revealed seasonality with a one year lag, suggesting good quality of data concerning these parameters. These results point to the hypothesis of potential errors or inconsistency with our study in the data collecting process regarding the energy consumption in the pump stations. A possible explanation lies in the fact that the energy consumption times series was made available in a monthly basis, thus potentially not reflecting precipitation peaks measured in a daily basis. The results of this study, as a preliminary conclusion, point that the impact of precipitation on the overall energy consumption in the wastewater treatment system of Feira de Santana is not significant.
id UEFS_fe7b7b152b0f09d2ce40a1a157efbe25
oai_identifier_str oai:tede2.uefs.br:8080:tede/275
network_acronym_str UEFS
network_name_str Biblioteca Digital de Teses e Dissertações da UEFS
repository_id_str
spelling Orrico, Sílvio Roberto Magalhães15674576572http://lattes.cnpq.br/9991771834473013Silva, Eduardo Henrique Borges Cohimhttp://lattes.cnpq.br/556829155265384201515759598http://lattes.cnpq.br/0734601016779791Santos, Quelle Rebouças dos2015-11-20T01:06:03Z2013-10-05SANTOS, Quelle Rebouças dos. Avaliação da influência da precipitação na rede de esgotamento sanitário do tipo separador absoluto - Feira de Santana – BA. 2013. 76 f. Dissertação (Mestrado em Engenharia Civil e Ambiental)- Universidade Estadual de Feira de Santana, Feira de Santana, 2013.http://localhost:8080/tede/handle/tede/275The objective of this study was to evaluate the influence of stormwater on the energy consumption in the pump stations of the urban sewage system of Feira de Santana city. Data concerning the energy consumption in the pump stations, the water consumption in the area, and the precipitation rate were collected for the time period of 2008-2011. Statistical tests were performed by applying the Spearman’s rank correlation, the Anderson-Darling goodness-of-fit test, the Student’s test t, and the Ljung-Box test. The results showed that, regarding a potential influence of the effective precipitation rate on the energy consumption in the pumps, the correlation not significantly different from zero with a 95% confidence level for all the 19 pump stations. Similar results were obtained for the case of the potential influence of the public water consumption on the energy consumption in the pump stations. However, considering the total energy consumption in the pump stations, the correlation with the effective precipitation is significant, although weak (R=0.30). Thus, it was estimated that 9% of the total energy consumption in the pump stations is explained by the precipitation. By analyzing the correlation between the energy consumption of all the pump stations, it was found that the all possible correlations are weak, and only in 12% of the cases the correlation is significantly different from zero with a 95% confidence level. Moreover, such correlation was not observed in pumping stations installed in series. In addition, seasonality tests applied to the time series precipitation and water consumption revealed seasonality with a one year lag, suggesting good quality of data concerning these parameters. These results point to the hypothesis of potential errors or inconsistency with our study in the data collecting process regarding the energy consumption in the pump stations. A possible explanation lies in the fact that the energy consumption times series was made available in a monthly basis, thus potentially not reflecting precipitation peaks measured in a daily basis. The results of this study, as a preliminary conclusion, point that the impact of precipitation on the overall energy consumption in the wastewater treatment system of Feira de Santana is not significant.Esta pesquisa teve com objetivo avaliar a influência da precipitação no consumo de energia das estações elevatórias do sistema de esgoto da cidade de Feira de Santana. Foram coletados dados de consumo de energia nas estações elevatórias, consumo de água e precipitação, durante período de 2008-2011. Os testes estatísticos coeficiente de correlação de postos de Spearman, teste de qualidade de ajuste de Anderson-Darling, o teste estatístico t de Student, e a estatística de Ljung-Box foram aplicados na análise. Os resultados mostram que, em relação a uma potencial influência da precipitação efetiva no consumo de energia das estações elevatórias, a correlação não é significativamente diferente de zero com um nível de confiança de 95% para todas as 15 estações elevatórias analisadas. Resultados semelhantes foram obtidos em relação à influência potencial do consumo público de água no consumo de energia das estações elevatórias. Contudo, considerando o consumo total de energia nas estações elevatórias, foi possível observar uma correlação significativa, embora fraca, entre a precipitação efetiva e esse consumo de energia (R=0.30). Assim, calculou-se que 9% deste consumo energético se deve à precipitação efetiva. Além de estes pontos, a análise da correlação entre o consumo de energia de todas as estações revela que todas as correlações possíveis são fracas, e que apenas em 12% dos casos a correlação é significativamente diferente de zero com um nível de confiança de 95%, sendo que esta correlação não se verificou em estações elevatórias que se encontram em série no sistema. Adicionalmente, testes de sazonalidade foram aplicados às séries temporais de precipitação e consumo de água, revelando sazonalidade com um ano de atraso, sugerindo boa qualidade de dados relativamente a estes parâmetros. Estes resultados apontam para a hipótese de inconsistência dos dados disponibilizados de consumo de energia nas estações em relação ao nosso estudo. Uma explicação possível foi o fato de que os dados de medição de energia encontraram-se agregados em médias mensais, assim podendo potencialmente não refletir picos de precipitação medidos em uma base diária. Contudo, os resultados deste estudo, como conclusão preliminar, apontam que o impacto da precipitação no consumo total de energia no sistema de tratamento de águas residuais de Feira de Santana deverá ser pouco significativo.Submitted by Natalie Mendes (nataliermendes@gmail.com) on 2015-11-20T01:06:03Z No. of bitstreams: 1 DISSERTAÇÃO - QUELLE.pdf: 2565380 bytes, checksum: eb95484178642dadbc525b49bf7eeb8c (MD5)Made available in DSpace on 2015-11-20T01:06:03Z (GMT). No. of bitstreams: 1 DISSERTAÇÃO - QUELLE.pdf: 2565380 bytes, checksum: eb95484178642dadbc525b49bf7eeb8c (MD5) Previous issue date: 2013-10-05Fundação de Amparo à Pesquisa do Estado da Bahia - FAPEBapplication/pdfporUniversidade Estadual de Feira de SantanaMestrado em Engenharia Civil e AmbientalUEFSBrasilDEPARTAMENTO DE TECNOLOGIAEstação elevatória de esgotoPrecipitaçãoSistema de esgotamento sanitárioSewage pumping stationPrecipitationSewage systemENGENHARIA CIVIL::CONSTRUCAO CIVILENGENHARIA SANITARIA::SANEAMENTO AMBIENTALSANEAMENTO BASICO::RESIDUOS SOLIDOS, DOMESTICOS E INDUSTRIAISAvaliação da influência da precipitação na rede de esgotamento sanitário do tipo separador absoluto - Feira de Santana - BAinfo:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/masterThesis-19309366784521606426006006006006006004335108523020347051-2538089779098232013801806404375711888782455233400114013104767858349021390776info:eu-repo/semantics/openAccessreponame:Biblioteca Digital de Teses e Dissertações da UEFSinstname:Universidade Estadual de Feira de Santana (UEFS)instacron:UEFSORIGINALDISSERTAÇÃO - QUELLE.pdfDISSERTAÇÃO - QUELLE.pdfapplication/pdf2565380http://tede2.uefs.br:8080/bitstream/tede/275/2/DISSERTA%C3%87%C3%83O+-+QUELLE.pdfeb95484178642dadbc525b49bf7eeb8cMD52LICENSElicense.txtlicense.txttext/plain; charset=utf-82165http://tede2.uefs.br:8080/bitstream/tede/275/1/license.txtbd3efa91386c1718a7f26a329fdcb468MD51tede/2752015-11-19 22:06:03.178oai:tede2.uefs.br:8080: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Biblioteca Digital de Teses e Dissertaçõeshttp://tede2.uefs.br:8080/PUBhttp://tede2.uefs.br:8080/oai/requestbcuefs@uefs.br|| bcref@uefs.br||bcuefs@uefs.bropendoar:2015-11-20T01:06:03Biblioteca Digital de Teses e Dissertações da UEFS - Universidade Estadual de Feira de Santana (UEFS)false
dc.title.por.fl_str_mv Avaliação da influência da precipitação na rede de esgotamento sanitário do tipo separador absoluto - Feira de Santana - BA
title Avaliação da influência da precipitação na rede de esgotamento sanitário do tipo separador absoluto - Feira de Santana - BA
spellingShingle Avaliação da influência da precipitação na rede de esgotamento sanitário do tipo separador absoluto - Feira de Santana - BA
Santos, Quelle Rebouças dos
Estação elevatória de esgoto
Precipitação
Sistema de esgotamento sanitário
Sewage pumping station
Precipitation
Sewage system
ENGENHARIA CIVIL::CONSTRUCAO CIVIL
ENGENHARIA SANITARIA::SANEAMENTO AMBIENTAL
SANEAMENTO BASICO::RESIDUOS SOLIDOS, DOMESTICOS E INDUSTRIAIS
title_short Avaliação da influência da precipitação na rede de esgotamento sanitário do tipo separador absoluto - Feira de Santana - BA
title_full Avaliação da influência da precipitação na rede de esgotamento sanitário do tipo separador absoluto - Feira de Santana - BA
title_fullStr Avaliação da influência da precipitação na rede de esgotamento sanitário do tipo separador absoluto - Feira de Santana - BA
title_full_unstemmed Avaliação da influência da precipitação na rede de esgotamento sanitário do tipo separador absoluto - Feira de Santana - BA
title_sort Avaliação da influência da precipitação na rede de esgotamento sanitário do tipo separador absoluto - Feira de Santana - BA
author Santos, Quelle Rebouças dos
author_facet Santos, Quelle Rebouças dos
author_role author
dc.contributor.advisor1.fl_str_mv Orrico, Sílvio Roberto Magalhães
dc.contributor.advisor1ID.fl_str_mv 15674576572
dc.contributor.advisor1Lattes.fl_str_mv http://lattes.cnpq.br/9991771834473013
dc.contributor.advisor-co1.fl_str_mv Silva, Eduardo Henrique Borges Cohim
dc.contributor.advisor-co1Lattes.fl_str_mv http://lattes.cnpq.br/5568291552653842
dc.contributor.authorID.fl_str_mv 01515759598
dc.contributor.authorLattes.fl_str_mv http://lattes.cnpq.br/0734601016779791
dc.contributor.author.fl_str_mv Santos, Quelle Rebouças dos
contributor_str_mv Orrico, Sílvio Roberto Magalhães
Silva, Eduardo Henrique Borges Cohim
dc.subject.por.fl_str_mv Estação elevatória de esgoto
Precipitação
Sistema de esgotamento sanitário
topic Estação elevatória de esgoto
Precipitação
Sistema de esgotamento sanitário
Sewage pumping station
Precipitation
Sewage system
ENGENHARIA CIVIL::CONSTRUCAO CIVIL
ENGENHARIA SANITARIA::SANEAMENTO AMBIENTAL
SANEAMENTO BASICO::RESIDUOS SOLIDOS, DOMESTICOS E INDUSTRIAIS
dc.subject.eng.fl_str_mv Sewage pumping station
Precipitation
Sewage system
dc.subject.cnpq.fl_str_mv ENGENHARIA CIVIL::CONSTRUCAO CIVIL
ENGENHARIA SANITARIA::SANEAMENTO AMBIENTAL
SANEAMENTO BASICO::RESIDUOS SOLIDOS, DOMESTICOS E INDUSTRIAIS
description The objective of this study was to evaluate the influence of stormwater on the energy consumption in the pump stations of the urban sewage system of Feira de Santana city. Data concerning the energy consumption in the pump stations, the water consumption in the area, and the precipitation rate were collected for the time period of 2008-2011. Statistical tests were performed by applying the Spearman’s rank correlation, the Anderson-Darling goodness-of-fit test, the Student’s test t, and the Ljung-Box test. The results showed that, regarding a potential influence of the effective precipitation rate on the energy consumption in the pumps, the correlation not significantly different from zero with a 95% confidence level for all the 19 pump stations. Similar results were obtained for the case of the potential influence of the public water consumption on the energy consumption in the pump stations. However, considering the total energy consumption in the pump stations, the correlation with the effective precipitation is significant, although weak (R=0.30). Thus, it was estimated that 9% of the total energy consumption in the pump stations is explained by the precipitation. By analyzing the correlation between the energy consumption of all the pump stations, it was found that the all possible correlations are weak, and only in 12% of the cases the correlation is significantly different from zero with a 95% confidence level. Moreover, such correlation was not observed in pumping stations installed in series. In addition, seasonality tests applied to the time series precipitation and water consumption revealed seasonality with a one year lag, suggesting good quality of data concerning these parameters. These results point to the hypothesis of potential errors or inconsistency with our study in the data collecting process regarding the energy consumption in the pump stations. A possible explanation lies in the fact that the energy consumption times series was made available in a monthly basis, thus potentially not reflecting precipitation peaks measured in a daily basis. The results of this study, as a preliminary conclusion, point that the impact of precipitation on the overall energy consumption in the wastewater treatment system of Feira de Santana is not significant.
publishDate 2013
dc.date.issued.fl_str_mv 2013-10-05
dc.date.accessioned.fl_str_mv 2015-11-20T01:06:03Z
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
dc.type.driver.fl_str_mv info:eu-repo/semantics/masterThesis
format masterThesis
status_str publishedVersion
dc.identifier.citation.fl_str_mv SANTOS, Quelle Rebouças dos. Avaliação da influência da precipitação na rede de esgotamento sanitário do tipo separador absoluto - Feira de Santana – BA. 2013. 76 f. Dissertação (Mestrado em Engenharia Civil e Ambiental)- Universidade Estadual de Feira de Santana, Feira de Santana, 2013.
dc.identifier.uri.fl_str_mv http://localhost:8080/tede/handle/tede/275
identifier_str_mv SANTOS, Quelle Rebouças dos. Avaliação da influência da precipitação na rede de esgotamento sanitário do tipo separador absoluto - Feira de Santana – BA. 2013. 76 f. Dissertação (Mestrado em Engenharia Civil e Ambiental)- Universidade Estadual de Feira de Santana, Feira de Santana, 2013.
url http://localhost:8080/tede/handle/tede/275
dc.language.iso.fl_str_mv por
language por
dc.relation.program.fl_str_mv -1930936678452160642
dc.relation.confidence.fl_str_mv 600
600
600
600
600
600
dc.relation.department.fl_str_mv 4335108523020347051
dc.relation.cnpq.fl_str_mv -2538089779098232013
8018064043757118887
8245523340011401310
dc.relation.sponsorship.fl_str_mv 4767858349021390776
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv application/pdf
dc.publisher.none.fl_str_mv Universidade Estadual de Feira de Santana
dc.publisher.program.fl_str_mv Mestrado em Engenharia Civil e Ambiental
dc.publisher.initials.fl_str_mv UEFS
dc.publisher.country.fl_str_mv Brasil
dc.publisher.department.fl_str_mv DEPARTAMENTO DE TECNOLOGIA
publisher.none.fl_str_mv Universidade Estadual de Feira de Santana
dc.source.none.fl_str_mv reponame:Biblioteca Digital de Teses e Dissertações da UEFS
instname:Universidade Estadual de Feira de Santana (UEFS)
instacron:UEFS
instname_str Universidade Estadual de Feira de Santana (UEFS)
instacron_str UEFS
institution UEFS
reponame_str Biblioteca Digital de Teses e Dissertações da UEFS
collection Biblioteca Digital de Teses e Dissertações da UEFS
bitstream.url.fl_str_mv http://tede2.uefs.br:8080/bitstream/tede/275/2/DISSERTA%C3%87%C3%83O+-+QUELLE.pdf
http://tede2.uefs.br:8080/bitstream/tede/275/1/license.txt
bitstream.checksum.fl_str_mv eb95484178642dadbc525b49bf7eeb8c
bd3efa91386c1718a7f26a329fdcb468
bitstream.checksumAlgorithm.fl_str_mv MD5
MD5
repository.name.fl_str_mv Biblioteca Digital de Teses e Dissertações da UEFS - Universidade Estadual de Feira de Santana (UEFS)
repository.mail.fl_str_mv bcuefs@uefs.br|| bcref@uefs.br||bcuefs@uefs.br
_version_ 1800214575421849600