Correlation between the haemocytometer and others routine techniques for platelet counting of dogs attended at Veterinary Hospital of Universidade Estadual de Londrina (V.H.-UEL)

Detalhes bibliográficos
Autor(a) principal: Silva, Patrícia Fernandes Nunes da
Data de Publicação: 2007
Outros Autores: Balarin, Mara Regina Stipp, Maruchi, Helem Paula, Flaiban, Karina Keller Marques da Costa, Moroz, Ludmila Rodrigues
Tipo de documento: Artigo
Idioma: por
Título da fonte: Semina. Ciências Agrárias (Online)
Texto Completo: https://ojs.uel.br/revistas/uel/index.php/semagrarias/article/view/2899
Resumo: Platelets counts were performed in 30 dogs for diagnostic investigation. For each dog, platelets counts were obtained using a manual haemocytometer and compared with counts obtained by estimation from a blood smear and a MS4® analyzer. None of the two methods gave high correlation with the count obtained by a Neubauer chamber. The analyzer gave the highest correlation.
id UEL-11_1358bd7b608193a0046d82a4a9549467
oai_identifier_str oai:ojs.pkp.sfu.ca:article/2899
network_acronym_str UEL-11
network_name_str Semina. Ciências Agrárias (Online)
repository_id_str
spelling Correlation between the haemocytometer and others routine techniques for platelet counting of dogs attended at Veterinary Hospital of Universidade Estadual de Londrina (V.H.-UEL)Correlação entre o hemocitômetro e outras técnicas de rotina para a contagem do número de plaquetas em cães atendidos no Hospital Veterinário da Universidade Estadual de Londrina (H.V.-UEL)Platelet countingDogsHaemocytometer.Contagem de plaquetasCãesHemocitômetro.Platelets counts were performed in 30 dogs for diagnostic investigation. For each dog, platelets counts were obtained using a manual haemocytometer and compared with counts obtained by estimation from a blood smear and a MS4® analyzer. None of the two methods gave high correlation with the count obtained by a Neubauer chamber. The analyzer gave the highest correlation.Foram realizadas contagens plaquetárias em 30 cães para investigação diagnóstica. Para cada cão, foram obtidas contagens de plaquetas utilizando-se hemocitômetro manual e comparadas com contagens realizadas a partir da estimativa no esfregaço sangüíneo e pelo contador eletrônico por impedância MS4®. Nenhum dos dois métodos apresentou alta correlação com a contagem feita em câmara de Neubauer; o analisador por impedância apresentou a maior correlação.UEL2007-08-30info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersionapplication/pdfhttps://ojs.uel.br/revistas/uel/index.php/semagrarias/article/view/289910.5433/1679-0359.2007v28n4p659Semina: Ciências Agrárias; Vol. 28 No. 4 (2007); 659-664Semina: Ciências Agrárias; v. 28 n. 4 (2007); 659-6641679-03591676-546Xreponame:Semina. Ciências Agrárias (Online)instname:Universidade Estadual de Londrina (UEL)instacron:UELporhttps://ojs.uel.br/revistas/uel/index.php/semagrarias/article/view/2899/2456Silva, Patrícia Fernandes Nunes daBalarin, Mara Regina StippMaruchi, Helem PaulaFlaiban, Karina Keller Marques da CostaMoroz, Ludmila Rodriguesinfo:eu-repo/semantics/openAccess2015-11-19T18:38:54Zoai:ojs.pkp.sfu.ca:article/2899Revistahttp://www.uel.br/revistas/uel/index.php/semagrariasPUBhttps://ojs.uel.br/revistas/uel/index.php/semagrarias/oaisemina.agrarias@uel.br1679-03591676-546Xopendoar:2015-11-19T18:38:54Semina. Ciências Agrárias (Online) - Universidade Estadual de Londrina (UEL)false
dc.title.none.fl_str_mv Correlation between the haemocytometer and others routine techniques for platelet counting of dogs attended at Veterinary Hospital of Universidade Estadual de Londrina (V.H.-UEL)
Correlação entre o hemocitômetro e outras técnicas de rotina para a contagem do número de plaquetas em cães atendidos no Hospital Veterinário da Universidade Estadual de Londrina (H.V.-UEL)
title Correlation between the haemocytometer and others routine techniques for platelet counting of dogs attended at Veterinary Hospital of Universidade Estadual de Londrina (V.H.-UEL)
spellingShingle Correlation between the haemocytometer and others routine techniques for platelet counting of dogs attended at Veterinary Hospital of Universidade Estadual de Londrina (V.H.-UEL)
Silva, Patrícia Fernandes Nunes da
Platelet counting
Dogs
Haemocytometer.
Contagem de plaquetas
Cães
Hemocitômetro.
title_short Correlation between the haemocytometer and others routine techniques for platelet counting of dogs attended at Veterinary Hospital of Universidade Estadual de Londrina (V.H.-UEL)
title_full Correlation between the haemocytometer and others routine techniques for platelet counting of dogs attended at Veterinary Hospital of Universidade Estadual de Londrina (V.H.-UEL)
title_fullStr Correlation between the haemocytometer and others routine techniques for platelet counting of dogs attended at Veterinary Hospital of Universidade Estadual de Londrina (V.H.-UEL)
title_full_unstemmed Correlation between the haemocytometer and others routine techniques for platelet counting of dogs attended at Veterinary Hospital of Universidade Estadual de Londrina (V.H.-UEL)
title_sort Correlation between the haemocytometer and others routine techniques for platelet counting of dogs attended at Veterinary Hospital of Universidade Estadual de Londrina (V.H.-UEL)
author Silva, Patrícia Fernandes Nunes da
author_facet Silva, Patrícia Fernandes Nunes da
Balarin, Mara Regina Stipp
Maruchi, Helem Paula
Flaiban, Karina Keller Marques da Costa
Moroz, Ludmila Rodrigues
author_role author
author2 Balarin, Mara Regina Stipp
Maruchi, Helem Paula
Flaiban, Karina Keller Marques da Costa
Moroz, Ludmila Rodrigues
author2_role author
author
author
author
dc.contributor.author.fl_str_mv Silva, Patrícia Fernandes Nunes da
Balarin, Mara Regina Stipp
Maruchi, Helem Paula
Flaiban, Karina Keller Marques da Costa
Moroz, Ludmila Rodrigues
dc.subject.por.fl_str_mv Platelet counting
Dogs
Haemocytometer.
Contagem de plaquetas
Cães
Hemocitômetro.
topic Platelet counting
Dogs
Haemocytometer.
Contagem de plaquetas
Cães
Hemocitômetro.
description Platelets counts were performed in 30 dogs for diagnostic investigation. For each dog, platelets counts were obtained using a manual haemocytometer and compared with counts obtained by estimation from a blood smear and a MS4® analyzer. None of the two methods gave high correlation with the count obtained by a Neubauer chamber. The analyzer gave the highest correlation.
publishDate 2007
dc.date.none.fl_str_mv 2007-08-30
dc.type.driver.fl_str_mv info:eu-repo/semantics/article
info:eu-repo/semantics/publishedVersion
format article
status_str publishedVersion
dc.identifier.uri.fl_str_mv https://ojs.uel.br/revistas/uel/index.php/semagrarias/article/view/2899
10.5433/1679-0359.2007v28n4p659
url https://ojs.uel.br/revistas/uel/index.php/semagrarias/article/view/2899
identifier_str_mv 10.5433/1679-0359.2007v28n4p659
dc.language.iso.fl_str_mv por
language por
dc.relation.none.fl_str_mv https://ojs.uel.br/revistas/uel/index.php/semagrarias/article/view/2899/2456
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv application/pdf
dc.publisher.none.fl_str_mv UEL
publisher.none.fl_str_mv UEL
dc.source.none.fl_str_mv Semina: Ciências Agrárias; Vol. 28 No. 4 (2007); 659-664
Semina: Ciências Agrárias; v. 28 n. 4 (2007); 659-664
1679-0359
1676-546X
reponame:Semina. Ciências Agrárias (Online)
instname:Universidade Estadual de Londrina (UEL)
instacron:UEL
instname_str Universidade Estadual de Londrina (UEL)
instacron_str UEL
institution UEL
reponame_str Semina. Ciências Agrárias (Online)
collection Semina. Ciências Agrárias (Online)
repository.name.fl_str_mv Semina. Ciências Agrárias (Online) - Universidade Estadual de Londrina (UEL)
repository.mail.fl_str_mv semina.agrarias@uel.br
_version_ 1799306059178835968