Ochratoxin A detection by spectrofluorimetry compared with high performance liquid c hromatography in coffee

Detalhes bibliográficos
Autor(a) principal: Ribeiro, Ricardo Marcelo Reche
Data de Publicação: 2008
Outros Autores: Fujii, Simone, Silva, Marcelo, Nogari, Andréia Botega, Scholz, Maria Brígida dos Santos, Ono, Elisabete Yurie Sataque, Kawamura, Osamu, Hirooka, Elisa Yoko
Tipo de documento: Artigo
Idioma: por
Título da fonte: Semina. Ciências Agrárias (Online)
Texto Completo: https://ojs.uel.br/revistas/uel/index.php/semagrarias/article/view/2824
Resumo: The Brazilian coffee production plays important role both in the national and oversea trade. The quality and sanity of coffee depend on fungal contamination, with emphasis on ochratoxin A (OTA) producing species, which is a nephrotoxin with hazardous effect in public health. The exigency on continuous monitoring and control of OTA in agricultural commodity requires a simple, rapid and accessible analytical methodology. The objective of this research was to set up the spectrofluorimetric method for OTA detection intended for monitoring in coffee, which was developed in data-correlation with high efficiency liquid chromatography (HPLC). The performance of spectrofluorimetric analysis was evaluated using artificially contaminated coffee (10, 20 and 50 ng/g), and the data compared with HPLC. Although of the fault of former technique, with recovery of 40.14 % and correlation coefficient of 0.79 when compared to HPLC, i.e. low reliability and inadequate efficiency, the data showed perspective to follow the improvement inserting new tool, and further standardization and certification.
id UEL-11_edc17a0c67a3e9cfe4a4e9049afd86e9
oai_identifier_str oai:ojs.pkp.sfu.ca:article/2824
network_acronym_str UEL-11
network_name_str Semina. Ciências Agrárias (Online)
repository_id_str
spelling Ochratoxin A detection by spectrofluorimetry compared with high performance liquid c hromatography in coffeeEspectrofluorimetria comparada à cromatografia líquida de alta eficiência na detecção de ocratoxina A em caféOchratoxin ACoffeeHPLCSpectrofluorimetry.Ocratoxina ACaféCLAEEspectrofluorimetria.The Brazilian coffee production plays important role both in the national and oversea trade. The quality and sanity of coffee depend on fungal contamination, with emphasis on ochratoxin A (OTA) producing species, which is a nephrotoxin with hazardous effect in public health. The exigency on continuous monitoring and control of OTA in agricultural commodity requires a simple, rapid and accessible analytical methodology. The objective of this research was to set up the spectrofluorimetric method for OTA detection intended for monitoring in coffee, which was developed in data-correlation with high efficiency liquid chromatography (HPLC). The performance of spectrofluorimetric analysis was evaluated using artificially contaminated coffee (10, 20 and 50 ng/g), and the data compared with HPLC. Although of the fault of former technique, with recovery of 40.14 % and correlation coefficient of 0.79 when compared to HPLC, i.e. low reliability and inadequate efficiency, the data showed perspective to follow the improvement inserting new tool, and further standardization and certification.A cafeicultura brasileira apresenta grande importância ao mercado interno e comércio exterior. A qualidade e sanidade do café dependem da contaminação fúngica, com ênfase as espécies produtoras de ocratoxina A (OTA), uma nefrotoxina de efeito deletério à saúde pública. A necessidade de contínuo monitoramento e controle de OTA em produtos agrícolas requer metodologia analítica simples, rápida e acessível. O trabalho teve como objetivo padronizar um método espectrofluorimétrico para detecção de OTA visando monitoramento em grãos de café, correlacionando-o com a cromatografia líquida de alta eficiência (CLAE). A aplicabilidade da espectrofluorimetria foi avaliada em café artificialmente contaminado com OTA (10, 20 e 50 ng/g), comparando os resultados obtidos com a CLAE. Embora a fluorimetria tenha apresentado resultados insatisfatórios, com recuperação de 40,14 % e coeficiente de correlação de 0,79 em relação a CLAE, i.e. baixa confiabilidade e eficiência inadequada, a técnica constitui perspectiva para prosseguir o estudo inserindo novos ensaios referentes à sua padronização e certificação.UEL2008-08-30info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersionapplication/pdfhttps://ojs.uel.br/revistas/uel/index.php/semagrarias/article/view/282410.5433/1679-0359.2008v29n2p331Semina: Ciências Agrárias; Vol. 29 No. 2 (2008); 331-338Semina: Ciências Agrárias; v. 29 n. 2 (2008); 331-3381679-03591676-546Xreponame:Semina. Ciências Agrárias (Online)instname:Universidade Estadual de Londrina (UEL)instacron:UELporhttps://ojs.uel.br/revistas/uel/index.php/semagrarias/article/view/2824/2400Ribeiro, Ricardo Marcelo RecheFujii, SimoneSilva, MarceloNogari, Andréia BotegaScholz, Maria Brígida dos SantosOno, Elisabete Yurie SataqueKawamura, OsamuHirooka, Elisa Yokoinfo:eu-repo/semantics/openAccess2015-11-19T18:38:48Zoai:ojs.pkp.sfu.ca:article/2824Revistahttp://www.uel.br/revistas/uel/index.php/semagrariasPUBhttps://ojs.uel.br/revistas/uel/index.php/semagrarias/oaisemina.agrarias@uel.br1679-03591676-546Xopendoar:2015-11-19T18:38:48Semina. Ciências Agrárias (Online) - Universidade Estadual de Londrina (UEL)false
dc.title.none.fl_str_mv Ochratoxin A detection by spectrofluorimetry compared with high performance liquid c hromatography in coffee
Espectrofluorimetria comparada à cromatografia líquida de alta eficiência na detecção de ocratoxina A em café
title Ochratoxin A detection by spectrofluorimetry compared with high performance liquid c hromatography in coffee
spellingShingle Ochratoxin A detection by spectrofluorimetry compared with high performance liquid c hromatography in coffee
Ribeiro, Ricardo Marcelo Reche
Ochratoxin A
Coffee
HPLC
Spectrofluorimetry.
Ocratoxina A
Café
CLAE
Espectrofluorimetria.
title_short Ochratoxin A detection by spectrofluorimetry compared with high performance liquid c hromatography in coffee
title_full Ochratoxin A detection by spectrofluorimetry compared with high performance liquid c hromatography in coffee
title_fullStr Ochratoxin A detection by spectrofluorimetry compared with high performance liquid c hromatography in coffee
title_full_unstemmed Ochratoxin A detection by spectrofluorimetry compared with high performance liquid c hromatography in coffee
title_sort Ochratoxin A detection by spectrofluorimetry compared with high performance liquid c hromatography in coffee
author Ribeiro, Ricardo Marcelo Reche
author_facet Ribeiro, Ricardo Marcelo Reche
Fujii, Simone
Silva, Marcelo
Nogari, Andréia Botega
Scholz, Maria Brígida dos Santos
Ono, Elisabete Yurie Sataque
Kawamura, Osamu
Hirooka, Elisa Yoko
author_role author
author2 Fujii, Simone
Silva, Marcelo
Nogari, Andréia Botega
Scholz, Maria Brígida dos Santos
Ono, Elisabete Yurie Sataque
Kawamura, Osamu
Hirooka, Elisa Yoko
author2_role author
author
author
author
author
author
author
dc.contributor.author.fl_str_mv Ribeiro, Ricardo Marcelo Reche
Fujii, Simone
Silva, Marcelo
Nogari, Andréia Botega
Scholz, Maria Brígida dos Santos
Ono, Elisabete Yurie Sataque
Kawamura, Osamu
Hirooka, Elisa Yoko
dc.subject.por.fl_str_mv Ochratoxin A
Coffee
HPLC
Spectrofluorimetry.
Ocratoxina A
Café
CLAE
Espectrofluorimetria.
topic Ochratoxin A
Coffee
HPLC
Spectrofluorimetry.
Ocratoxina A
Café
CLAE
Espectrofluorimetria.
description The Brazilian coffee production plays important role both in the national and oversea trade. The quality and sanity of coffee depend on fungal contamination, with emphasis on ochratoxin A (OTA) producing species, which is a nephrotoxin with hazardous effect in public health. The exigency on continuous monitoring and control of OTA in agricultural commodity requires a simple, rapid and accessible analytical methodology. The objective of this research was to set up the spectrofluorimetric method for OTA detection intended for monitoring in coffee, which was developed in data-correlation with high efficiency liquid chromatography (HPLC). The performance of spectrofluorimetric analysis was evaluated using artificially contaminated coffee (10, 20 and 50 ng/g), and the data compared with HPLC. Although of the fault of former technique, with recovery of 40.14 % and correlation coefficient of 0.79 when compared to HPLC, i.e. low reliability and inadequate efficiency, the data showed perspective to follow the improvement inserting new tool, and further standardization and certification.
publishDate 2008
dc.date.none.fl_str_mv 2008-08-30
dc.type.driver.fl_str_mv info:eu-repo/semantics/article
info:eu-repo/semantics/publishedVersion
format article
status_str publishedVersion
dc.identifier.uri.fl_str_mv https://ojs.uel.br/revistas/uel/index.php/semagrarias/article/view/2824
10.5433/1679-0359.2008v29n2p331
url https://ojs.uel.br/revistas/uel/index.php/semagrarias/article/view/2824
identifier_str_mv 10.5433/1679-0359.2008v29n2p331
dc.language.iso.fl_str_mv por
language por
dc.relation.none.fl_str_mv https://ojs.uel.br/revistas/uel/index.php/semagrarias/article/view/2824/2400
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv application/pdf
dc.publisher.none.fl_str_mv UEL
publisher.none.fl_str_mv UEL
dc.source.none.fl_str_mv Semina: Ciências Agrárias; Vol. 29 No. 2 (2008); 331-338
Semina: Ciências Agrárias; v. 29 n. 2 (2008); 331-338
1679-0359
1676-546X
reponame:Semina. Ciências Agrárias (Online)
instname:Universidade Estadual de Londrina (UEL)
instacron:UEL
instname_str Universidade Estadual de Londrina (UEL)
instacron_str UEL
institution UEL
reponame_str Semina. Ciências Agrárias (Online)
collection Semina. Ciências Agrárias (Online)
repository.name.fl_str_mv Semina. Ciências Agrárias (Online) - Universidade Estadual de Londrina (UEL)
repository.mail.fl_str_mv semina.agrarias@uel.br
_version_ 1799306055323222016