Resumo: Although, in recent years, great efforts have been made to inform and make health professionals aware of the importance of sterilization, disinfection and antisepsis, little considerations have been shown in relation to the quality of the water of dental unit systems. In the present work 72 samples of water from 68 dental equipments and 4 faucets were submitted to bacteriological analysis, with the objective of detecting heterothrophic bacteria and coliform group. The samples collected from the faucets were compatible with the water potability patterns. In contrast, 63 (92.7%) of the 68 samples obtained from the dental unit water systems were considered contaminated and only 5 (7.3%) were in agreement with the potability patterns. It was observed that 42 water samples (61.8%) were heavily contaminated, 14 (20.6%) presented moderate index of contamination and 7 (10.3%) were slightly contaminated. The results suggest the need of decontamination of water reservoirs and hoses of these equipments
id UEM-1_69d98870e56774d4192e8f66cad4097b
oai_identifier_str oai:periodicos.uem.br/ojs:article/2998
network_acronym_str UEM-1
network_name_str Acta Scientiarum Biological Sciences
repository_id_str
spelling Bacteriological analysis of water in dental unitsAnálise bacteriológica da água de equipos odontológicosanálise bacteriológicaequipos odontológicoságuacontaminação2.00.00.00-6 Ciências BiológicasAlthough, in recent years, great efforts have been made to inform and make health professionals aware of the importance of sterilization, disinfection and antisepsis, little considerations have been shown in relation to the quality of the water of dental unit systems. In the present work 72 samples of water from 68 dental equipments and 4 faucets were submitted to bacteriological analysis, with the objective of detecting heterothrophic bacteria and coliform group. The samples collected from the faucets were compatible with the water potability patterns. In contrast, 63 (92.7%) of the 68 samples obtained from the dental unit water systems were considered contaminated and only 5 (7.3%) were in agreement with the potability patterns. It was observed that 42 water samples (61.8%) were heavily contaminated, 14 (20.6%) presented moderate index of contamination and 7 (10.3%) were slightly contaminated. The results suggest the need of decontamination of water reservoirs and hoses of these equipmentsNos últimos anos, grande esforço tem sido feito para conscientizar os profissionais da saúde sobre a importância dos processos de esterilização e anti-sepsia. Entretanto, pouca atenção tem sido dispensada pelos cirurgiões-dentistas à qualidade da água utilizada na prática odontológica. Neste trabalho, realizamos 72 análises bacteriológicas em amostras de água de 68 equipos odontológicos e de 4 torneiras, para verificar a qualidade microbiológica da água, através da contagem de bactérias heterotróficas e pesquisa de coliformes. As amostras coletadas das torneiras apresentaram valores compatíveis com os padrões de potabilidade. Das 68 amostras obtidas dos equipos 63 (92,7%) estavam contaminadas e 5 (7,3%) estavam dentro dos padrões de potabilidade. Observou-se que 42 equipos (61,8%) continham água acentuadamente contaminada, 14 (20,6%) apresentaram índice moderado de contaminação e 7 (10,3%) estavam com a água levemente contaminada. Estes resultados apontam a necessidade de cuidados especiais, tais como a descontaminação e a desinfecção periódica dos sistemas de água dos equiposUniversidade Estadual De Maringá2008-05-09info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersionapplication/pdfhttp://www.periodicos.uem.br/ojs/index.php/ActaSciBiolSci/article/view/299810.4025/actascibiolsci.v22i0.2998Acta Scientiarum. Biological Sciences; Vol 22 (2000); 631-636Acta Scientiarum. Biological Sciences; v. 22 (2000); 631-6361807-863X1679-9283reponame:Acta Scientiarum Biological Sciencesinstname:Universidade Estadual de Maringá (UEM)instacron:UEMporhttp://www.periodicos.uem.br/ojs/index.php/ActaSciBiolSci/article/view/2998/2142Xavier, Hiran Vinicius MatelliBulla, Joice RenataLuize, Luciana MeloMoreno, TatianaTognim, Maria Cristina BronharoGarcia, Lourdes Botelhoinfo:eu-repo/semantics/openAccess2022-11-23T17:33:33Zoai:periodicos.uem.br/ojs:article/2998Revistahttp://www.periodicos.uem.br/ojs/index.php/ActaSciBiolSciPUBhttp://www.periodicos.uem.br/ojs/index.php/ActaSciBiolSci/oai||actabiol@uem.br1807-863X1679-9283opendoar:2022-11-23T17:33:33Acta Scientiarum Biological Sciences - Universidade Estadual de Maringá (UEM)false
dc.title.none.fl_str_mv Bacteriological analysis of water in dental units
Análise bacteriológica da água de equipos odontológicos
title Bacteriological analysis of water in dental units
spellingShingle Bacteriological analysis of water in dental units
Xavier, Hiran Vinicius Matelli
análise bacteriológica
equipos odontológicos
água
contaminação
2.00.00.00-6 Ciências Biológicas
title_short Bacteriological analysis of water in dental units
title_full Bacteriological analysis of water in dental units
title_fullStr Bacteriological analysis of water in dental units
title_full_unstemmed Bacteriological analysis of water in dental units
title_sort Bacteriological analysis of water in dental units
author Xavier, Hiran Vinicius Matelli
author_facet Xavier, Hiran Vinicius Matelli
Bulla, Joice Renata
Luize, Luciana Melo
Moreno, Tatiana
Tognim, Maria Cristina Bronharo
Garcia, Lourdes Botelho
author_role author
author2 Bulla, Joice Renata
Luize, Luciana Melo
Moreno, Tatiana
Tognim, Maria Cristina Bronharo
Garcia, Lourdes Botelho
author2_role author
author
author
author
author
dc.contributor.author.fl_str_mv Xavier, Hiran Vinicius Matelli
Bulla, Joice Renata
Luize, Luciana Melo
Moreno, Tatiana
Tognim, Maria Cristina Bronharo
Garcia, Lourdes Botelho
dc.subject.por.fl_str_mv análise bacteriológica
equipos odontológicos
água
contaminação
2.00.00.00-6 Ciências Biológicas
topic análise bacteriológica
equipos odontológicos
água
contaminação
2.00.00.00-6 Ciências Biológicas
description Although, in recent years, great efforts have been made to inform and make health professionals aware of the importance of sterilization, disinfection and antisepsis, little considerations have been shown in relation to the quality of the water of dental unit systems. In the present work 72 samples of water from 68 dental equipments and 4 faucets were submitted to bacteriological analysis, with the objective of detecting heterothrophic bacteria and coliform group. The samples collected from the faucets were compatible with the water potability patterns. In contrast, 63 (92.7%) of the 68 samples obtained from the dental unit water systems were considered contaminated and only 5 (7.3%) were in agreement with the potability patterns. It was observed that 42 water samples (61.8%) were heavily contaminated, 14 (20.6%) presented moderate index of contamination and 7 (10.3%) were slightly contaminated. The results suggest the need of decontamination of water reservoirs and hoses of these equipments
publishDate 2008
dc.date.none.fl_str_mv 2008-05-09
dc.type.driver.fl_str_mv info:eu-repo/semantics/article
info:eu-repo/semantics/publishedVersion
format article
status_str publishedVersion
dc.identifier.uri.fl_str_mv http://www.periodicos.uem.br/ojs/index.php/ActaSciBiolSci/article/view/2998
10.4025/actascibiolsci.v22i0.2998
url http://www.periodicos.uem.br/ojs/index.php/ActaSciBiolSci/article/view/2998
identifier_str_mv 10.4025/actascibiolsci.v22i0.2998
dc.language.iso.fl_str_mv por
language por
dc.relation.none.fl_str_mv http://www.periodicos.uem.br/ojs/index.php/ActaSciBiolSci/article/view/2998/2142
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv application/pdf
dc.publisher.none.fl_str_mv Universidade Estadual De Maringá
publisher.none.fl_str_mv Universidade Estadual De Maringá
dc.source.none.fl_str_mv Acta Scientiarum. Biological Sciences; Vol 22 (2000); 631-636
Acta Scientiarum. Biological Sciences; v. 22 (2000); 631-636
1807-863X
1679-9283
reponame:Acta Scientiarum Biological Sciences
instname:Universidade Estadual de Maringá (UEM)
instacron:UEM
instname_str Universidade Estadual de Maringá (UEM)
instacron_str UEM
institution UEM
reponame_str Acta Scientiarum Biological Sciences
collection Acta Scientiarum Biological Sciences
repository.name.fl_str_mv Acta Scientiarum Biological Sciences - Universidade Estadual de Maringá (UEM)
repository.mail.fl_str_mv ||actabiol@uem.br
_version_ 1799317393562927104