Bacteriological analysis of water in dental units
Autor(a) principal: | |
---|---|
Data de Publicação: | 2008 |
Outros Autores: | , , , , |
Tipo de documento: | Artigo |
Idioma: | por |
Título da fonte: | Acta Scientiarum Biological Sciences |
Texto Completo: | http://www.periodicos.uem.br/ojs/index.php/ActaSciBiolSci/article/view/2998 |
Resumo: | Although, in recent years, great efforts have been made to inform and make health professionals aware of the importance of sterilization, disinfection and antisepsis, little considerations have been shown in relation to the quality of the water of dental unit systems. In the present work 72 samples of water from 68 dental equipments and 4 faucets were submitted to bacteriological analysis, with the objective of detecting heterothrophic bacteria and coliform group. The samples collected from the faucets were compatible with the water potability patterns. In contrast, 63 (92.7%) of the 68 samples obtained from the dental unit water systems were considered contaminated and only 5 (7.3%) were in agreement with the potability patterns. It was observed that 42 water samples (61.8%) were heavily contaminated, 14 (20.6%) presented moderate index of contamination and 7 (10.3%) were slightly contaminated. The results suggest the need of decontamination of water reservoirs and hoses of these equipments |
id |
UEM-1_69d98870e56774d4192e8f66cad4097b |
---|---|
oai_identifier_str |
oai:periodicos.uem.br/ojs:article/2998 |
network_acronym_str |
UEM-1 |
network_name_str |
Acta Scientiarum Biological Sciences |
repository_id_str |
|
spelling |
Bacteriological analysis of water in dental unitsAnálise bacteriológica da água de equipos odontológicosanálise bacteriológicaequipos odontológicoságuacontaminação2.00.00.00-6 Ciências BiológicasAlthough, in recent years, great efforts have been made to inform and make health professionals aware of the importance of sterilization, disinfection and antisepsis, little considerations have been shown in relation to the quality of the water of dental unit systems. In the present work 72 samples of water from 68 dental equipments and 4 faucets were submitted to bacteriological analysis, with the objective of detecting heterothrophic bacteria and coliform group. The samples collected from the faucets were compatible with the water potability patterns. In contrast, 63 (92.7%) of the 68 samples obtained from the dental unit water systems were considered contaminated and only 5 (7.3%) were in agreement with the potability patterns. It was observed that 42 water samples (61.8%) were heavily contaminated, 14 (20.6%) presented moderate index of contamination and 7 (10.3%) were slightly contaminated. The results suggest the need of decontamination of water reservoirs and hoses of these equipmentsNos últimos anos, grande esforço tem sido feito para conscientizar os profissionais da saúde sobre a importância dos processos de esterilização e anti-sepsia. Entretanto, pouca atenção tem sido dispensada pelos cirurgiões-dentistas à qualidade da água utilizada na prática odontológica. Neste trabalho, realizamos 72 análises bacteriológicas em amostras de água de 68 equipos odontológicos e de 4 torneiras, para verificar a qualidade microbiológica da água, através da contagem de bactérias heterotróficas e pesquisa de coliformes. As amostras coletadas das torneiras apresentaram valores compatíveis com os padrões de potabilidade. Das 68 amostras obtidas dos equipos 63 (92,7%) estavam contaminadas e 5 (7,3%) estavam dentro dos padrões de potabilidade. Observou-se que 42 equipos (61,8%) continham água acentuadamente contaminada, 14 (20,6%) apresentaram índice moderado de contaminação e 7 (10,3%) estavam com a água levemente contaminada. Estes resultados apontam a necessidade de cuidados especiais, tais como a descontaminação e a desinfecção periódica dos sistemas de água dos equiposUniversidade Estadual De Maringá2008-05-09info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersionapplication/pdfhttp://www.periodicos.uem.br/ojs/index.php/ActaSciBiolSci/article/view/299810.4025/actascibiolsci.v22i0.2998Acta Scientiarum. Biological Sciences; Vol 22 (2000); 631-636Acta Scientiarum. Biological Sciences; v. 22 (2000); 631-6361807-863X1679-9283reponame:Acta Scientiarum Biological Sciencesinstname:Universidade Estadual de Maringá (UEM)instacron:UEMporhttp://www.periodicos.uem.br/ojs/index.php/ActaSciBiolSci/article/view/2998/2142Xavier, Hiran Vinicius MatelliBulla, Joice RenataLuize, Luciana MeloMoreno, TatianaTognim, Maria Cristina BronharoGarcia, Lourdes Botelhoinfo:eu-repo/semantics/openAccess2022-11-23T17:33:33Zoai:periodicos.uem.br/ojs:article/2998Revistahttp://www.periodicos.uem.br/ojs/index.php/ActaSciBiolSciPUBhttp://www.periodicos.uem.br/ojs/index.php/ActaSciBiolSci/oai||actabiol@uem.br1807-863X1679-9283opendoar:2022-11-23T17:33:33Acta Scientiarum Biological Sciences - Universidade Estadual de Maringá (UEM)false |
dc.title.none.fl_str_mv |
Bacteriological analysis of water in dental units Análise bacteriológica da água de equipos odontológicos |
title |
Bacteriological analysis of water in dental units |
spellingShingle |
Bacteriological analysis of water in dental units Xavier, Hiran Vinicius Matelli análise bacteriológica equipos odontológicos água contaminação 2.00.00.00-6 Ciências Biológicas |
title_short |
Bacteriological analysis of water in dental units |
title_full |
Bacteriological analysis of water in dental units |
title_fullStr |
Bacteriological analysis of water in dental units |
title_full_unstemmed |
Bacteriological analysis of water in dental units |
title_sort |
Bacteriological analysis of water in dental units |
author |
Xavier, Hiran Vinicius Matelli |
author_facet |
Xavier, Hiran Vinicius Matelli Bulla, Joice Renata Luize, Luciana Melo Moreno, Tatiana Tognim, Maria Cristina Bronharo Garcia, Lourdes Botelho |
author_role |
author |
author2 |
Bulla, Joice Renata Luize, Luciana Melo Moreno, Tatiana Tognim, Maria Cristina Bronharo Garcia, Lourdes Botelho |
author2_role |
author author author author author |
dc.contributor.author.fl_str_mv |
Xavier, Hiran Vinicius Matelli Bulla, Joice Renata Luize, Luciana Melo Moreno, Tatiana Tognim, Maria Cristina Bronharo Garcia, Lourdes Botelho |
dc.subject.por.fl_str_mv |
análise bacteriológica equipos odontológicos água contaminação 2.00.00.00-6 Ciências Biológicas |
topic |
análise bacteriológica equipos odontológicos água contaminação 2.00.00.00-6 Ciências Biológicas |
description |
Although, in recent years, great efforts have been made to inform and make health professionals aware of the importance of sterilization, disinfection and antisepsis, little considerations have been shown in relation to the quality of the water of dental unit systems. In the present work 72 samples of water from 68 dental equipments and 4 faucets were submitted to bacteriological analysis, with the objective of detecting heterothrophic bacteria and coliform group. The samples collected from the faucets were compatible with the water potability patterns. In contrast, 63 (92.7%) of the 68 samples obtained from the dental unit water systems were considered contaminated and only 5 (7.3%) were in agreement with the potability patterns. It was observed that 42 water samples (61.8%) were heavily contaminated, 14 (20.6%) presented moderate index of contamination and 7 (10.3%) were slightly contaminated. The results suggest the need of decontamination of water reservoirs and hoses of these equipments |
publishDate |
2008 |
dc.date.none.fl_str_mv |
2008-05-09 |
dc.type.driver.fl_str_mv |
info:eu-repo/semantics/article info:eu-repo/semantics/publishedVersion |
format |
article |
status_str |
publishedVersion |
dc.identifier.uri.fl_str_mv |
http://www.periodicos.uem.br/ojs/index.php/ActaSciBiolSci/article/view/2998 10.4025/actascibiolsci.v22i0.2998 |
url |
http://www.periodicos.uem.br/ojs/index.php/ActaSciBiolSci/article/view/2998 |
identifier_str_mv |
10.4025/actascibiolsci.v22i0.2998 |
dc.language.iso.fl_str_mv |
por |
language |
por |
dc.relation.none.fl_str_mv |
http://www.periodicos.uem.br/ojs/index.php/ActaSciBiolSci/article/view/2998/2142 |
dc.rights.driver.fl_str_mv |
info:eu-repo/semantics/openAccess |
eu_rights_str_mv |
openAccess |
dc.format.none.fl_str_mv |
application/pdf |
dc.publisher.none.fl_str_mv |
Universidade Estadual De Maringá |
publisher.none.fl_str_mv |
Universidade Estadual De Maringá |
dc.source.none.fl_str_mv |
Acta Scientiarum. Biological Sciences; Vol 22 (2000); 631-636 Acta Scientiarum. Biological Sciences; v. 22 (2000); 631-636 1807-863X 1679-9283 reponame:Acta Scientiarum Biological Sciences instname:Universidade Estadual de Maringá (UEM) instacron:UEM |
instname_str |
Universidade Estadual de Maringá (UEM) |
instacron_str |
UEM |
institution |
UEM |
reponame_str |
Acta Scientiarum Biological Sciences |
collection |
Acta Scientiarum Biological Sciences |
repository.name.fl_str_mv |
Acta Scientiarum Biological Sciences - Universidade Estadual de Maringá (UEM) |
repository.mail.fl_str_mv |
||actabiol@uem.br |
_version_ |
1799317393562927104 |