Application of the organic chlorination in the treatment of tubedripper used in the irrigation with water high in iron content - DOI: 10.4025/actasciagron.v32i1.1589
Autor(a) principal: | |
---|---|
Data de Publicação: | 2009 |
Outros Autores: | , , |
Tipo de documento: | Artigo |
Idioma: | por |
Título da fonte: | Acta Scientiarum. Agronomy (Online) |
Texto Completo: | http://www.periodicos.uem.br/ojs/index.php/ActaSciAgron/article/view/1589 |
Resumo: | To evaluate the effect of the organic chlorination in the uniformity of water distribution and in the outflow of a tubedripper with 2,2 L h-1, had been tested four levels of concentrations of dicloroisocianurato of sodium (N1 = 0, N2 = 15, N3 = 30 e N4 = 45 mg L-1 of free chlorine). The evaluations had been carried through in the beginning of the experiment and to each 100 hours of functioning of the system, totalizing 8 evaluations. In the calculation of the uniformity of water application had been used the coefficients of uniformity of Christiansen (CUC), of distribution (CUD) and emission (Us). Also the study of the discharge and the coefficient of variation of the discharge (CVq). It was verified that in the level N1, reductions of 23; 30.2 and 8.35%, for the CUC, CUD and US, respectively. The discharge presented a 6.13% reduction, reflecting in an increase of the CVq. The treatment with dicloro was efficient to prevent against clogging for all the used concentrations and the system was classified with excellent uniformity in practically all the evaluations. |
id |
UEM-5_7259cc7dffcffc793dde80bce34ef403 |
---|---|
oai_identifier_str |
oai:periodicos.uem.br/ojs:article/1589 |
network_acronym_str |
UEM-5 |
network_name_str |
Acta Scientiarum. Agronomy (Online) |
repository_id_str |
|
spelling |
Application of the organic chlorination in the treatment of tubedripper used in the irrigation with water high in iron content - DOI: 10.4025/actasciagron.v32i1.1589Aplicação de cloro orgânico no tratamento de tubogotejador utilizado na irrigação com água ferruginosa - DOI: 10.4025/actasciagron.v32i1.1589chlorineironcloggingcloroferroentupimentoIrrigação e DrenagemTo evaluate the effect of the organic chlorination in the uniformity of water distribution and in the outflow of a tubedripper with 2,2 L h-1, had been tested four levels of concentrations of dicloroisocianurato of sodium (N1 = 0, N2 = 15, N3 = 30 e N4 = 45 mg L-1 of free chlorine). The evaluations had been carried through in the beginning of the experiment and to each 100 hours of functioning of the system, totalizing 8 evaluations. In the calculation of the uniformity of water application had been used the coefficients of uniformity of Christiansen (CUC), of distribution (CUD) and emission (Us). Also the study of the discharge and the coefficient of variation of the discharge (CVq). It was verified that in the level N1, reductions of 23; 30.2 and 8.35%, for the CUC, CUD and US, respectively. The discharge presented a 6.13% reduction, reflecting in an increase of the CVq. The treatment with dicloro was efficient to prevent against clogging for all the used concentrations and the system was classified with excellent uniformity in practically all the evaluations.Para avaliar o efeito da cloração orgânica na uniformidade de distribuição de água e na vazão de um tubogotejador com vazão de 2,2 L h-1, foram testados quatro níveis de concentrações de dicloroisocianurato de sódio (N1 = 0, N2 = 15, N3 = 30 e N4 = 45 mg L-1 de cloro livre). As avaliações foram realizadas no início do experimento e a cada 100 horas de funcionamento do sistema, totalizando 8 avaliações. No cálculo da uniformidade de aplicação de água foram utilizados os coeficientes de uniformidade de Christiansen (CUC), de distribuição (CUD) e de emissão (Us). Também se realizou o estudo da vazão e do coeficiente de variação da vazão (CVq). Verificou-se que no nível N1 ocorreram reduções de 23; 30,2 e 8,35%, para o CUC, CUD e Us, respectivamente, sendo que a vazão apresentou uma redução de 6,13%, refletindo em um aumento do CVq. O tratamento com dicloro foi eficiente para precaver contra entupimento para todas as concentrações utilizadas e o sistema foi classificado com excelente uniformidade em praticamente todas as avaliações.Universidade Estadual de Maringá2009-11-04info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersionpesquisa de campoapplication/pdfhttp://www.periodicos.uem.br/ojs/index.php/ActaSciAgron/article/view/158910.4025/actasciagron.v32i1.1589Acta Scientiarum. Agronomy; Vol 32 No 1 (2010); 1-5Acta Scientiarum. Agronomy; v. 32 n. 1 (2010); 1-51807-86211679-9275reponame:Acta Scientiarum. Agronomy (Online)instname:Universidade Estadual de Maringá (UEM)instacron:UEMporhttp://www.periodicos.uem.br/ojs/index.php/ActaSciAgron/article/view/1589/1589Martins, Cristiani CamposSoares, Antonio AlvesRamos, Márcio MotaReis, Edvaldo Fialho dosinfo:eu-repo/semantics/openAccess2022-11-23T18:37:26Zoai:periodicos.uem.br/ojs:article/1589Revistahttp://www.periodicos.uem.br/ojs/index.php/ActaSciAgronPUBhttp://www.periodicos.uem.br/ojs/index.php/ActaSciAgron/oaiactaagron@uem.br||actaagron@uem.br|| edamasio@uem.br1807-86211679-9275opendoar:2022-11-23T18:37:26Acta Scientiarum. Agronomy (Online) - Universidade Estadual de Maringá (UEM)false |
dc.title.none.fl_str_mv |
Application of the organic chlorination in the treatment of tubedripper used in the irrigation with water high in iron content - DOI: 10.4025/actasciagron.v32i1.1589 Aplicação de cloro orgânico no tratamento de tubogotejador utilizado na irrigação com água ferruginosa - DOI: 10.4025/actasciagron.v32i1.1589 |
title |
Application of the organic chlorination in the treatment of tubedripper used in the irrigation with water high in iron content - DOI: 10.4025/actasciagron.v32i1.1589 |
spellingShingle |
Application of the organic chlorination in the treatment of tubedripper used in the irrigation with water high in iron content - DOI: 10.4025/actasciagron.v32i1.1589 Martins, Cristiani Campos chlorine iron clogging cloro ferro entupimento Irrigação e Drenagem |
title_short |
Application of the organic chlorination in the treatment of tubedripper used in the irrigation with water high in iron content - DOI: 10.4025/actasciagron.v32i1.1589 |
title_full |
Application of the organic chlorination in the treatment of tubedripper used in the irrigation with water high in iron content - DOI: 10.4025/actasciagron.v32i1.1589 |
title_fullStr |
Application of the organic chlorination in the treatment of tubedripper used in the irrigation with water high in iron content - DOI: 10.4025/actasciagron.v32i1.1589 |
title_full_unstemmed |
Application of the organic chlorination in the treatment of tubedripper used in the irrigation with water high in iron content - DOI: 10.4025/actasciagron.v32i1.1589 |
title_sort |
Application of the organic chlorination in the treatment of tubedripper used in the irrigation with water high in iron content - DOI: 10.4025/actasciagron.v32i1.1589 |
author |
Martins, Cristiani Campos |
author_facet |
Martins, Cristiani Campos Soares, Antonio Alves Ramos, Márcio Mota Reis, Edvaldo Fialho dos |
author_role |
author |
author2 |
Soares, Antonio Alves Ramos, Márcio Mota Reis, Edvaldo Fialho dos |
author2_role |
author author author |
dc.contributor.author.fl_str_mv |
Martins, Cristiani Campos Soares, Antonio Alves Ramos, Márcio Mota Reis, Edvaldo Fialho dos |
dc.subject.por.fl_str_mv |
chlorine iron clogging cloro ferro entupimento Irrigação e Drenagem |
topic |
chlorine iron clogging cloro ferro entupimento Irrigação e Drenagem |
description |
To evaluate the effect of the organic chlorination in the uniformity of water distribution and in the outflow of a tubedripper with 2,2 L h-1, had been tested four levels of concentrations of dicloroisocianurato of sodium (N1 = 0, N2 = 15, N3 = 30 e N4 = 45 mg L-1 of free chlorine). The evaluations had been carried through in the beginning of the experiment and to each 100 hours of functioning of the system, totalizing 8 evaluations. In the calculation of the uniformity of water application had been used the coefficients of uniformity of Christiansen (CUC), of distribution (CUD) and emission (Us). Also the study of the discharge and the coefficient of variation of the discharge (CVq). It was verified that in the level N1, reductions of 23; 30.2 and 8.35%, for the CUC, CUD and US, respectively. The discharge presented a 6.13% reduction, reflecting in an increase of the CVq. The treatment with dicloro was efficient to prevent against clogging for all the used concentrations and the system was classified with excellent uniformity in practically all the evaluations. |
publishDate |
2009 |
dc.date.none.fl_str_mv |
2009-11-04 |
dc.type.driver.fl_str_mv |
info:eu-repo/semantics/article info:eu-repo/semantics/publishedVersion pesquisa de campo |
format |
article |
status_str |
publishedVersion |
dc.identifier.uri.fl_str_mv |
http://www.periodicos.uem.br/ojs/index.php/ActaSciAgron/article/view/1589 10.4025/actasciagron.v32i1.1589 |
url |
http://www.periodicos.uem.br/ojs/index.php/ActaSciAgron/article/view/1589 |
identifier_str_mv |
10.4025/actasciagron.v32i1.1589 |
dc.language.iso.fl_str_mv |
por |
language |
por |
dc.relation.none.fl_str_mv |
http://www.periodicos.uem.br/ojs/index.php/ActaSciAgron/article/view/1589/1589 |
dc.rights.driver.fl_str_mv |
info:eu-repo/semantics/openAccess |
eu_rights_str_mv |
openAccess |
dc.format.none.fl_str_mv |
application/pdf |
dc.publisher.none.fl_str_mv |
Universidade Estadual de Maringá |
publisher.none.fl_str_mv |
Universidade Estadual de Maringá |
dc.source.none.fl_str_mv |
Acta Scientiarum. Agronomy; Vol 32 No 1 (2010); 1-5 Acta Scientiarum. Agronomy; v. 32 n. 1 (2010); 1-5 1807-8621 1679-9275 reponame:Acta Scientiarum. Agronomy (Online) instname:Universidade Estadual de Maringá (UEM) instacron:UEM |
instname_str |
Universidade Estadual de Maringá (UEM) |
instacron_str |
UEM |
institution |
UEM |
reponame_str |
Acta Scientiarum. Agronomy (Online) |
collection |
Acta Scientiarum. Agronomy (Online) |
repository.name.fl_str_mv |
Acta Scientiarum. Agronomy (Online) - Universidade Estadual de Maringá (UEM) |
repository.mail.fl_str_mv |
actaagron@uem.br||actaagron@uem.br|| edamasio@uem.br |
_version_ |
1799305903901507584 |