Construction and calibration of a bar weighing lysimeter

Detalhes bibliográficos
Autor(a) principal: Mariano, Daiane Cinque
Data de Publicação: 2015
Outros Autores: Faria, Rogério Teixeira, Freitas, Paulo Sergio Lourenço de, Lena, Bruno Patias, Johann, Andre Luiz
Tipo de documento: Artigo
Idioma: eng
Título da fonte: Acta Scientiarum. Agronomy (Online)
Texto Completo: http://www.periodicos.uem.br/ojs/index.php/ActaSciAgron/article/view/19368
Resumo: Generally, standard lysimeters include a lever-load cell scale, which has become expensive compared to new electronic equipment available for experimental purposes. Currently, lysimeters containing weighing bars with up to 4 load cells are economically feasible. This goal of this study was to present the construction and calibration of four weighing lysimeters built using two rectangular tanks, with a surface area of 1.35 m2 (1 m by 1.35 m) and a depth of 1.5 m, loaded on two weighing bars. Each bar had two high accuracy loading cells connected to a junction box and a datalogger by a coaxial cable. Calibration of each lysimeter was performed after field installation. The results showed a linear response (R2 > 0.9999) of electric signal (mV) to mass increase or decrease (kg) with minimum hysteresis. The mean absolute error of the mass estimate (0.0245 to 0.2844 equivalent-mm) and a Willmott index between the observed and estimated data (d = 1.0000) indicate the high precision of the new equipment. The results allow concluding that the lysimeters in this study are appropriate for estimating evapotranspiration and other components of soil water balance. 
id UEM-5_a88693843d20daec6ed294e6b7e10d5f
oai_identifier_str oai:periodicos.uem.br/ojs:article/19368
network_acronym_str UEM-5
network_name_str Acta Scientiarum. Agronomy (Online)
repository_id_str
spelling Construction and calibration of a bar weighing lysimeterevapotranspirationwater balancesoil waterengenharia de água e soloGenerally, standard lysimeters include a lever-load cell scale, which has become expensive compared to new electronic equipment available for experimental purposes. Currently, lysimeters containing weighing bars with up to 4 load cells are economically feasible. This goal of this study was to present the construction and calibration of four weighing lysimeters built using two rectangular tanks, with a surface area of 1.35 m2 (1 m by 1.35 m) and a depth of 1.5 m, loaded on two weighing bars. Each bar had two high accuracy loading cells connected to a junction box and a datalogger by a coaxial cable. Calibration of each lysimeter was performed after field installation. The results showed a linear response (R2 > 0.9999) of electric signal (mV) to mass increase or decrease (kg) with minimum hysteresis. The mean absolute error of the mass estimate (0.0245 to 0.2844 equivalent-mm) and a Willmott index between the observed and estimated data (d = 1.0000) indicate the high precision of the new equipment. The results allow concluding that the lysimeters in this study are appropriate for estimating evapotranspiration and other components of soil water balance. Universidade Estadual de Maringá2015-08-03info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersionPesquisaapplication/pdfhttp://www.periodicos.uem.br/ojs/index.php/ActaSciAgron/article/view/1936810.4025/actasciagron.v37i3.19368Acta Scientiarum. Agronomy; Vol 37 No 3 (2015); 271-278Acta Scientiarum. Agronomy; v. 37 n. 3 (2015); 271-2781807-86211679-9275reponame:Acta Scientiarum. Agronomy (Online)instname:Universidade Estadual de Maringá (UEM)instacron:UEMenghttp://www.periodicos.uem.br/ojs/index.php/ActaSciAgron/article/view/19368/pdf_61Mariano, Daiane CinqueFaria, Rogério TeixeiraFreitas, Paulo Sergio Lourenço deLena, Bruno PatiasJohann, Andre Luizinfo:eu-repo/semantics/openAccess2015-08-12T14:22:36Zoai:periodicos.uem.br/ojs:article/19368Revistahttp://www.periodicos.uem.br/ojs/index.php/ActaSciAgronPUBhttp://www.periodicos.uem.br/ojs/index.php/ActaSciAgron/oaiactaagron@uem.br||actaagron@uem.br|| edamasio@uem.br1807-86211679-9275opendoar:2015-08-12T14:22:36Acta Scientiarum. Agronomy (Online) - Universidade Estadual de Maringá (UEM)false
dc.title.none.fl_str_mv Construction and calibration of a bar weighing lysimeter
title Construction and calibration of a bar weighing lysimeter
spellingShingle Construction and calibration of a bar weighing lysimeter
Mariano, Daiane Cinque
evapotranspiration
water balance
soil water
engenharia de água e solo
title_short Construction and calibration of a bar weighing lysimeter
title_full Construction and calibration of a bar weighing lysimeter
title_fullStr Construction and calibration of a bar weighing lysimeter
title_full_unstemmed Construction and calibration of a bar weighing lysimeter
title_sort Construction and calibration of a bar weighing lysimeter
author Mariano, Daiane Cinque
author_facet Mariano, Daiane Cinque
Faria, Rogério Teixeira
Freitas, Paulo Sergio Lourenço de
Lena, Bruno Patias
Johann, Andre Luiz
author_role author
author2 Faria, Rogério Teixeira
Freitas, Paulo Sergio Lourenço de
Lena, Bruno Patias
Johann, Andre Luiz
author2_role author
author
author
author
dc.contributor.author.fl_str_mv Mariano, Daiane Cinque
Faria, Rogério Teixeira
Freitas, Paulo Sergio Lourenço de
Lena, Bruno Patias
Johann, Andre Luiz
dc.subject.por.fl_str_mv evapotranspiration
water balance
soil water
engenharia de água e solo
topic evapotranspiration
water balance
soil water
engenharia de água e solo
description Generally, standard lysimeters include a lever-load cell scale, which has become expensive compared to new electronic equipment available for experimental purposes. Currently, lysimeters containing weighing bars with up to 4 load cells are economically feasible. This goal of this study was to present the construction and calibration of four weighing lysimeters built using two rectangular tanks, with a surface area of 1.35 m2 (1 m by 1.35 m) and a depth of 1.5 m, loaded on two weighing bars. Each bar had two high accuracy loading cells connected to a junction box and a datalogger by a coaxial cable. Calibration of each lysimeter was performed after field installation. The results showed a linear response (R2 > 0.9999) of electric signal (mV) to mass increase or decrease (kg) with minimum hysteresis. The mean absolute error of the mass estimate (0.0245 to 0.2844 equivalent-mm) and a Willmott index between the observed and estimated data (d = 1.0000) indicate the high precision of the new equipment. The results allow concluding that the lysimeters in this study are appropriate for estimating evapotranspiration and other components of soil water balance. 
publishDate 2015
dc.date.none.fl_str_mv 2015-08-03
dc.type.driver.fl_str_mv info:eu-repo/semantics/article
info:eu-repo/semantics/publishedVersion
Pesquisa
format article
status_str publishedVersion
dc.identifier.uri.fl_str_mv http://www.periodicos.uem.br/ojs/index.php/ActaSciAgron/article/view/19368
10.4025/actasciagron.v37i3.19368
url http://www.periodicos.uem.br/ojs/index.php/ActaSciAgron/article/view/19368
identifier_str_mv 10.4025/actasciagron.v37i3.19368
dc.language.iso.fl_str_mv eng
language eng
dc.relation.none.fl_str_mv http://www.periodicos.uem.br/ojs/index.php/ActaSciAgron/article/view/19368/pdf_61
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv application/pdf
dc.publisher.none.fl_str_mv Universidade Estadual de Maringá
publisher.none.fl_str_mv Universidade Estadual de Maringá
dc.source.none.fl_str_mv Acta Scientiarum. Agronomy; Vol 37 No 3 (2015); 271-278
Acta Scientiarum. Agronomy; v. 37 n. 3 (2015); 271-278
1807-8621
1679-9275
reponame:Acta Scientiarum. Agronomy (Online)
instname:Universidade Estadual de Maringá (UEM)
instacron:UEM
instname_str Universidade Estadual de Maringá (UEM)
instacron_str UEM
institution UEM
reponame_str Acta Scientiarum. Agronomy (Online)
collection Acta Scientiarum. Agronomy (Online)
repository.name.fl_str_mv Acta Scientiarum. Agronomy (Online) - Universidade Estadual de Maringá (UEM)
repository.mail.fl_str_mv actaagron@uem.br||actaagron@uem.br|| edamasio@uem.br
_version_ 1799305909299576832