Resumo: | Generally, standard lysimeters include a lever-load cell scale, which has become expensive compared to new electronic equipment available for experimental purposes. Currently, lysimeters containing weighing bars with up to 4 load cells are economically feasible. This goal of this study was to present the construction and calibration of four weighing lysimeters built using two rectangular tanks, with a surface area of 1.35 m2 (1 m by 1.35 m) and a depth of 1.5 m, loaded on two weighing bars. Each bar had two high accuracy loading cells connected to a junction box and a datalogger by a coaxial cable. Calibration of each lysimeter was performed after field installation. The results showed a linear response (R2 > 0.9999) of electric signal (mV) to mass increase or decrease (kg) with minimum hysteresis. The mean absolute error of the mass estimate (0.0245 to 0.2844 equivalent-mm) and a Willmott index between the observed and estimated data (d = 1.0000) indicate the high precision of the new equipment. The results allow concluding that the lysimeters in this study are appropriate for estimating evapotranspiration and other components of soil water balance. |
id |
UEM-5_a88693843d20daec6ed294e6b7e10d5f |
---|---|
oai_identifier_str |
oai:periodicos.uem.br/ojs:article/19368 |
network_acronym_str |
UEM-5 |
network_name_str |
Acta Scientiarum. Agronomy (Online) |
repository_id_str |
|
spelling |
Construction and calibration of a bar weighing lysimeterevapotranspirationwater balancesoil waterengenharia de água e soloGenerally, standard lysimeters include a lever-load cell scale, which has become expensive compared to new electronic equipment available for experimental purposes. Currently, lysimeters containing weighing bars with up to 4 load cells are economically feasible. This goal of this study was to present the construction and calibration of four weighing lysimeters built using two rectangular tanks, with a surface area of 1.35 m2 (1 m by 1.35 m) and a depth of 1.5 m, loaded on two weighing bars. Each bar had two high accuracy loading cells connected to a junction box and a datalogger by a coaxial cable. Calibration of each lysimeter was performed after field installation. The results showed a linear response (R2 > 0.9999) of electric signal (mV) to mass increase or decrease (kg) with minimum hysteresis. The mean absolute error of the mass estimate (0.0245 to 0.2844 equivalent-mm) and a Willmott index between the observed and estimated data (d = 1.0000) indicate the high precision of the new equipment. The results allow concluding that the lysimeters in this study are appropriate for estimating evapotranspiration and other components of soil water balance. Universidade Estadual de Maringá2015-08-03info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersionPesquisaapplication/pdfhttp://www.periodicos.uem.br/ojs/index.php/ActaSciAgron/article/view/1936810.4025/actasciagron.v37i3.19368Acta Scientiarum. Agronomy; Vol 37 No 3 (2015); 271-278Acta Scientiarum. Agronomy; v. 37 n. 3 (2015); 271-2781807-86211679-9275reponame:Acta Scientiarum. Agronomy (Online)instname:Universidade Estadual de Maringá (UEM)instacron:UEMenghttp://www.periodicos.uem.br/ojs/index.php/ActaSciAgron/article/view/19368/pdf_61Mariano, Daiane CinqueFaria, Rogério TeixeiraFreitas, Paulo Sergio Lourenço deLena, Bruno PatiasJohann, Andre Luizinfo:eu-repo/semantics/openAccess2015-08-12T14:22:36Zoai:periodicos.uem.br/ojs:article/19368Revistahttp://www.periodicos.uem.br/ojs/index.php/ActaSciAgronPUBhttp://www.periodicos.uem.br/ojs/index.php/ActaSciAgron/oaiactaagron@uem.br||actaagron@uem.br|| edamasio@uem.br1807-86211679-9275opendoar:2015-08-12T14:22:36Acta Scientiarum. Agronomy (Online) - Universidade Estadual de Maringá (UEM)false |
dc.title.none.fl_str_mv |
Construction and calibration of a bar weighing lysimeter |
title |
Construction and calibration of a bar weighing lysimeter |
spellingShingle |
Construction and calibration of a bar weighing lysimeter Mariano, Daiane Cinque evapotranspiration water balance soil water engenharia de água e solo |
title_short |
Construction and calibration of a bar weighing lysimeter |
title_full |
Construction and calibration of a bar weighing lysimeter |
title_fullStr |
Construction and calibration of a bar weighing lysimeter |
title_full_unstemmed |
Construction and calibration of a bar weighing lysimeter |
title_sort |
Construction and calibration of a bar weighing lysimeter |
author |
Mariano, Daiane Cinque |
author_facet |
Mariano, Daiane Cinque Faria, Rogério Teixeira Freitas, Paulo Sergio Lourenço de Lena, Bruno Patias Johann, Andre Luiz |
author_role |
author |
author2 |
Faria, Rogério Teixeira Freitas, Paulo Sergio Lourenço de Lena, Bruno Patias Johann, Andre Luiz |
author2_role |
author author author author |
dc.contributor.author.fl_str_mv |
Mariano, Daiane Cinque Faria, Rogério Teixeira Freitas, Paulo Sergio Lourenço de Lena, Bruno Patias Johann, Andre Luiz |
dc.subject.por.fl_str_mv |
evapotranspiration water balance soil water engenharia de água e solo |
topic |
evapotranspiration water balance soil water engenharia de água e solo |
description |
Generally, standard lysimeters include a lever-load cell scale, which has become expensive compared to new electronic equipment available for experimental purposes. Currently, lysimeters containing weighing bars with up to 4 load cells are economically feasible. This goal of this study was to present the construction and calibration of four weighing lysimeters built using two rectangular tanks, with a surface area of 1.35 m2 (1 m by 1.35 m) and a depth of 1.5 m, loaded on two weighing bars. Each bar had two high accuracy loading cells connected to a junction box and a datalogger by a coaxial cable. Calibration of each lysimeter was performed after field installation. The results showed a linear response (R2 > 0.9999) of electric signal (mV) to mass increase or decrease (kg) with minimum hysteresis. The mean absolute error of the mass estimate (0.0245 to 0.2844 equivalent-mm) and a Willmott index between the observed and estimated data (d = 1.0000) indicate the high precision of the new equipment. The results allow concluding that the lysimeters in this study are appropriate for estimating evapotranspiration and other components of soil water balance. |
publishDate |
2015 |
dc.date.none.fl_str_mv |
2015-08-03 |
dc.type.driver.fl_str_mv |
info:eu-repo/semantics/article info:eu-repo/semantics/publishedVersion Pesquisa |
format |
article |
status_str |
publishedVersion |
dc.identifier.uri.fl_str_mv |
http://www.periodicos.uem.br/ojs/index.php/ActaSciAgron/article/view/19368 10.4025/actasciagron.v37i3.19368 |
url |
http://www.periodicos.uem.br/ojs/index.php/ActaSciAgron/article/view/19368 |
identifier_str_mv |
10.4025/actasciagron.v37i3.19368 |
dc.language.iso.fl_str_mv |
eng |
language |
eng |
dc.relation.none.fl_str_mv |
http://www.periodicos.uem.br/ojs/index.php/ActaSciAgron/article/view/19368/pdf_61 |
dc.rights.driver.fl_str_mv |
info:eu-repo/semantics/openAccess |
eu_rights_str_mv |
openAccess |
dc.format.none.fl_str_mv |
application/pdf |
dc.publisher.none.fl_str_mv |
Universidade Estadual de Maringá |
publisher.none.fl_str_mv |
Universidade Estadual de Maringá |
dc.source.none.fl_str_mv |
Acta Scientiarum. Agronomy; Vol 37 No 3 (2015); 271-278 Acta Scientiarum. Agronomy; v. 37 n. 3 (2015); 271-278 1807-8621 1679-9275 reponame:Acta Scientiarum. Agronomy (Online) instname:Universidade Estadual de Maringá (UEM) instacron:UEM |
instname_str |
Universidade Estadual de Maringá (UEM) |
instacron_str |
UEM |
institution |
UEM |
reponame_str |
Acta Scientiarum. Agronomy (Online) |
collection |
Acta Scientiarum. Agronomy (Online) |
repository.name.fl_str_mv |
Acta Scientiarum. Agronomy (Online) - Universidade Estadual de Maringá (UEM) |
repository.mail.fl_str_mv |
actaagron@uem.br||actaagron@uem.br|| edamasio@uem.br |
_version_ |
1799305909299576832 |