Influence of flow direction in the performance of anaerobic filters - doi: 10.4025/actascitechnol.v34i2.10353
Autor(a) principal: | |
---|---|
Data de Publicação: | 2011 |
Outros Autores: | , , , |
Tipo de documento: | Artigo |
Idioma: | por eng |
Título da fonte: | Acta scientiarum. Technology (Online) |
Texto Completo: | http://www.periodicos.uem.br/ojs/index.php/ActaSciTechnol/article/view/10353 |
Resumo: | This work aimed to evaluate the performance of similar anaerobic filters operating with opposite wastewater flows, and compare mathematical models that describe the kinetics of organic matter degradation in both. Two pilot-scale filters were fed with domestic effluent – one filter worked as upflow (UAF) and the other as downflow (DAF). Experimental COD data obtained from samples taken along the length of the filters were used to fit the first-order mathematical model, the model proposed by Leduy and Zajic (1973) and the model proposed by Brasil et al. (2007). The first model showed overestimated reaction constant (k) values when compared to those obtained using the other models. The models proposed by Brasil et al. (2007) and Leduy and Zajic (1973) presented the highest coefficients of determination (R2). The average removal efficiencies of total COD were equal to 68 and 79% for UAF and DAF, respectively. The results revealed no significant differences between the two filters with regard to the variables applied. |
id |
UEM-6_96d0ebca61aa22c710181270d580146b |
---|---|
oai_identifier_str |
oai:periodicos.uem.br/ojs:article/10353 |
network_acronym_str |
UEM-6 |
network_name_str |
Acta scientiarum. Technology (Online) |
repository_id_str |
|
spelling |
Influence of flow direction in the performance of anaerobic filters - doi: 10.4025/actascitechnol.v34i2.10353kineticsanaerobic upflow reactoranaerobic downflow reactordomestic wastewaterSaneamento AmbientalThis work aimed to evaluate the performance of similar anaerobic filters operating with opposite wastewater flows, and compare mathematical models that describe the kinetics of organic matter degradation in both. Two pilot-scale filters were fed with domestic effluent – one filter worked as upflow (UAF) and the other as downflow (DAF). Experimental COD data obtained from samples taken along the length of the filters were used to fit the first-order mathematical model, the model proposed by Leduy and Zajic (1973) and the model proposed by Brasil et al. (2007). The first model showed overestimated reaction constant (k) values when compared to those obtained using the other models. The models proposed by Brasil et al. (2007) and Leduy and Zajic (1973) presented the highest coefficients of determination (R2). The average removal efficiencies of total COD were equal to 68 and 79% for UAF and DAF, respectively. The results revealed no significant differences between the two filters with regard to the variables applied.Universidade Estadual De Maringá2011-11-09info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersiontratamento de efluentes; degradação anaeróbia; Saneamentoapplication/pdfapplication/pdfhttp://www.periodicos.uem.br/ojs/index.php/ActaSciTechnol/article/view/1035310.4025/actascitechnol.v34i2.10353Acta Scientiarum. Technology; Vol 34 No 2 (2012); 141-147Acta Scientiarum. Technology; v. 34 n. 2 (2012); 141-1471806-25631807-8664reponame:Acta scientiarum. Technology (Online)instname:Universidade Estadual de Maringá (UEM)instacron:UEMporenghttp://www.periodicos.uem.br/ojs/index.php/ActaSciTechnol/article/view/10353/pdfhttp://www.periodicos.uem.br/ojs/index.php/ActaSciTechnol/article/view/10353/pdf_1Fia, RonaldoSchuery, Filipe CruzMatos, Antonio Teixeira deFia, Fátima Resende LuizBorges, Alisson Carraroinfo:eu-repo/semantics/openAccess2024-05-17T13:03:16Zoai:periodicos.uem.br/ojs:article/10353Revistahttps://www.periodicos.uem.br/ojs/index.php/ActaSciTechnol/indexPUBhttps://www.periodicos.uem.br/ojs/index.php/ActaSciTechnol/oai||actatech@uem.br1807-86641806-2563opendoar:2024-05-17T13:03:16Acta scientiarum. Technology (Online) - Universidade Estadual de Maringá (UEM)false |
dc.title.none.fl_str_mv |
Influence of flow direction in the performance of anaerobic filters - doi: 10.4025/actascitechnol.v34i2.10353 |
title |
Influence of flow direction in the performance of anaerobic filters - doi: 10.4025/actascitechnol.v34i2.10353 |
spellingShingle |
Influence of flow direction in the performance of anaerobic filters - doi: 10.4025/actascitechnol.v34i2.10353 Fia, Ronaldo kinetics anaerobic upflow reactor anaerobic downflow reactor domestic wastewater Saneamento Ambiental |
title_short |
Influence of flow direction in the performance of anaerobic filters - doi: 10.4025/actascitechnol.v34i2.10353 |
title_full |
Influence of flow direction in the performance of anaerobic filters - doi: 10.4025/actascitechnol.v34i2.10353 |
title_fullStr |
Influence of flow direction in the performance of anaerobic filters - doi: 10.4025/actascitechnol.v34i2.10353 |
title_full_unstemmed |
Influence of flow direction in the performance of anaerobic filters - doi: 10.4025/actascitechnol.v34i2.10353 |
title_sort |
Influence of flow direction in the performance of anaerobic filters - doi: 10.4025/actascitechnol.v34i2.10353 |
author |
Fia, Ronaldo |
author_facet |
Fia, Ronaldo Schuery, Filipe Cruz Matos, Antonio Teixeira de Fia, Fátima Resende Luiz Borges, Alisson Carraro |
author_role |
author |
author2 |
Schuery, Filipe Cruz Matos, Antonio Teixeira de Fia, Fátima Resende Luiz Borges, Alisson Carraro |
author2_role |
author author author author |
dc.contributor.author.fl_str_mv |
Fia, Ronaldo Schuery, Filipe Cruz Matos, Antonio Teixeira de Fia, Fátima Resende Luiz Borges, Alisson Carraro |
dc.subject.por.fl_str_mv |
kinetics anaerobic upflow reactor anaerobic downflow reactor domestic wastewater Saneamento Ambiental |
topic |
kinetics anaerobic upflow reactor anaerobic downflow reactor domestic wastewater Saneamento Ambiental |
description |
This work aimed to evaluate the performance of similar anaerobic filters operating with opposite wastewater flows, and compare mathematical models that describe the kinetics of organic matter degradation in both. Two pilot-scale filters were fed with domestic effluent – one filter worked as upflow (UAF) and the other as downflow (DAF). Experimental COD data obtained from samples taken along the length of the filters were used to fit the first-order mathematical model, the model proposed by Leduy and Zajic (1973) and the model proposed by Brasil et al. (2007). The first model showed overestimated reaction constant (k) values when compared to those obtained using the other models. The models proposed by Brasil et al. (2007) and Leduy and Zajic (1973) presented the highest coefficients of determination (R2). The average removal efficiencies of total COD were equal to 68 and 79% for UAF and DAF, respectively. The results revealed no significant differences between the two filters with regard to the variables applied. |
publishDate |
2011 |
dc.date.none.fl_str_mv |
2011-11-09 |
dc.type.driver.fl_str_mv |
info:eu-repo/semantics/article info:eu-repo/semantics/publishedVersion tratamento de efluentes; degradação anaeróbia; Saneamento |
format |
article |
status_str |
publishedVersion |
dc.identifier.uri.fl_str_mv |
http://www.periodicos.uem.br/ojs/index.php/ActaSciTechnol/article/view/10353 10.4025/actascitechnol.v34i2.10353 |
url |
http://www.periodicos.uem.br/ojs/index.php/ActaSciTechnol/article/view/10353 |
identifier_str_mv |
10.4025/actascitechnol.v34i2.10353 |
dc.language.iso.fl_str_mv |
por eng |
language |
por eng |
dc.relation.none.fl_str_mv |
http://www.periodicos.uem.br/ojs/index.php/ActaSciTechnol/article/view/10353/pdf http://www.periodicos.uem.br/ojs/index.php/ActaSciTechnol/article/view/10353/pdf_1 |
dc.rights.driver.fl_str_mv |
info:eu-repo/semantics/openAccess |
eu_rights_str_mv |
openAccess |
dc.format.none.fl_str_mv |
application/pdf application/pdf |
dc.publisher.none.fl_str_mv |
Universidade Estadual De Maringá |
publisher.none.fl_str_mv |
Universidade Estadual De Maringá |
dc.source.none.fl_str_mv |
Acta Scientiarum. Technology; Vol 34 No 2 (2012); 141-147 Acta Scientiarum. Technology; v. 34 n. 2 (2012); 141-147 1806-2563 1807-8664 reponame:Acta scientiarum. Technology (Online) instname:Universidade Estadual de Maringá (UEM) instacron:UEM |
instname_str |
Universidade Estadual de Maringá (UEM) |
instacron_str |
UEM |
institution |
UEM |
reponame_str |
Acta scientiarum. Technology (Online) |
collection |
Acta scientiarum. Technology (Online) |
repository.name.fl_str_mv |
Acta scientiarum. Technology (Online) - Universidade Estadual de Maringá (UEM) |
repository.mail.fl_str_mv |
||actatech@uem.br |
_version_ |
1799315333883887616 |