Influence of flow direction in the performance of anaerobic filters - doi: 10.4025/actascitechnol.v34i2.10353

Detalhes bibliográficos
Autor(a) principal: Fia, Ronaldo
Data de Publicação: 2011
Outros Autores: Schuery, Filipe Cruz, Matos, Antonio Teixeira de, Fia, Fátima Resende Luiz, Borges, Alisson Carraro
Tipo de documento: Artigo
Idioma: por
eng
Título da fonte: Acta scientiarum. Technology (Online)
Texto Completo: http://www.periodicos.uem.br/ojs/index.php/ActaSciTechnol/article/view/10353
Resumo: This work aimed to evaluate the performance of similar anaerobic filters operating with opposite wastewater flows, and compare mathematical models that describe the kinetics of organic matter degradation in both. Two pilot-scale filters were fed with domestic effluent – one filter worked as upflow (UAF) and the other as downflow (DAF). Experimental COD data obtained from samples taken along the length of the filters were used to fit the first-order mathematical model, the model proposed by Leduy and Zajic (1973) and the model proposed by Brasil et al. (2007). The first model showed overestimated reaction constant (k) values when compared to those obtained using the other models. The models proposed by Brasil et al. (2007) and Leduy and Zajic (1973) presented the highest coefficients of determination (R2). The average removal efficiencies of total COD were equal to 68 and 79% for UAF and DAF, respectively. The results revealed no significant differences between the two filters with regard to the variables applied.
id UEM-6_96d0ebca61aa22c710181270d580146b
oai_identifier_str oai:periodicos.uem.br/ojs:article/10353
network_acronym_str UEM-6
network_name_str Acta scientiarum. Technology (Online)
repository_id_str
spelling Influence of flow direction in the performance of anaerobic filters - doi: 10.4025/actascitechnol.v34i2.10353kineticsanaerobic upflow reactoranaerobic downflow reactordomestic wastewaterSaneamento AmbientalThis work aimed to evaluate the performance of similar anaerobic filters operating with opposite wastewater flows, and compare mathematical models that describe the kinetics of organic matter degradation in both. Two pilot-scale filters were fed with domestic effluent – one filter worked as upflow (UAF) and the other as downflow (DAF). Experimental COD data obtained from samples taken along the length of the filters were used to fit the first-order mathematical model, the model proposed by Leduy and Zajic (1973) and the model proposed by Brasil et al. (2007). The first model showed overestimated reaction constant (k) values when compared to those obtained using the other models. The models proposed by Brasil et al. (2007) and Leduy and Zajic (1973) presented the highest coefficients of determination (R2). The average removal efficiencies of total COD were equal to 68 and 79% for UAF and DAF, respectively. The results revealed no significant differences between the two filters with regard to the variables applied.Universidade Estadual De Maringá2011-11-09info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersiontratamento de efluentes; degradação anaeróbia; Saneamentoapplication/pdfapplication/pdfhttp://www.periodicos.uem.br/ojs/index.php/ActaSciTechnol/article/view/1035310.4025/actascitechnol.v34i2.10353Acta Scientiarum. Technology; Vol 34 No 2 (2012); 141-147Acta Scientiarum. Technology; v. 34 n. 2 (2012); 141-1471806-25631807-8664reponame:Acta scientiarum. Technology (Online)instname:Universidade Estadual de Maringá (UEM)instacron:UEMporenghttp://www.periodicos.uem.br/ojs/index.php/ActaSciTechnol/article/view/10353/pdfhttp://www.periodicos.uem.br/ojs/index.php/ActaSciTechnol/article/view/10353/pdf_1Fia, RonaldoSchuery, Filipe CruzMatos, Antonio Teixeira deFia, Fátima Resende LuizBorges, Alisson Carraroinfo:eu-repo/semantics/openAccess2024-05-17T13:03:16Zoai:periodicos.uem.br/ojs:article/10353Revistahttps://www.periodicos.uem.br/ojs/index.php/ActaSciTechnol/indexPUBhttps://www.periodicos.uem.br/ojs/index.php/ActaSciTechnol/oai||actatech@uem.br1807-86641806-2563opendoar:2024-05-17T13:03:16Acta scientiarum. Technology (Online) - Universidade Estadual de Maringá (UEM)false
dc.title.none.fl_str_mv Influence of flow direction in the performance of anaerobic filters - doi: 10.4025/actascitechnol.v34i2.10353
title Influence of flow direction in the performance of anaerobic filters - doi: 10.4025/actascitechnol.v34i2.10353
spellingShingle Influence of flow direction in the performance of anaerobic filters - doi: 10.4025/actascitechnol.v34i2.10353
Fia, Ronaldo
kinetics
anaerobic upflow reactor
anaerobic downflow reactor
domestic wastewater
Saneamento Ambiental
title_short Influence of flow direction in the performance of anaerobic filters - doi: 10.4025/actascitechnol.v34i2.10353
title_full Influence of flow direction in the performance of anaerobic filters - doi: 10.4025/actascitechnol.v34i2.10353
title_fullStr Influence of flow direction in the performance of anaerobic filters - doi: 10.4025/actascitechnol.v34i2.10353
title_full_unstemmed Influence of flow direction in the performance of anaerobic filters - doi: 10.4025/actascitechnol.v34i2.10353
title_sort Influence of flow direction in the performance of anaerobic filters - doi: 10.4025/actascitechnol.v34i2.10353
author Fia, Ronaldo
author_facet Fia, Ronaldo
Schuery, Filipe Cruz
Matos, Antonio Teixeira de
Fia, Fátima Resende Luiz
Borges, Alisson Carraro
author_role author
author2 Schuery, Filipe Cruz
Matos, Antonio Teixeira de
Fia, Fátima Resende Luiz
Borges, Alisson Carraro
author2_role author
author
author
author
dc.contributor.author.fl_str_mv Fia, Ronaldo
Schuery, Filipe Cruz
Matos, Antonio Teixeira de
Fia, Fátima Resende Luiz
Borges, Alisson Carraro
dc.subject.por.fl_str_mv kinetics
anaerobic upflow reactor
anaerobic downflow reactor
domestic wastewater
Saneamento Ambiental
topic kinetics
anaerobic upflow reactor
anaerobic downflow reactor
domestic wastewater
Saneamento Ambiental
description This work aimed to evaluate the performance of similar anaerobic filters operating with opposite wastewater flows, and compare mathematical models that describe the kinetics of organic matter degradation in both. Two pilot-scale filters were fed with domestic effluent – one filter worked as upflow (UAF) and the other as downflow (DAF). Experimental COD data obtained from samples taken along the length of the filters were used to fit the first-order mathematical model, the model proposed by Leduy and Zajic (1973) and the model proposed by Brasil et al. (2007). The first model showed overestimated reaction constant (k) values when compared to those obtained using the other models. The models proposed by Brasil et al. (2007) and Leduy and Zajic (1973) presented the highest coefficients of determination (R2). The average removal efficiencies of total COD were equal to 68 and 79% for UAF and DAF, respectively. The results revealed no significant differences between the two filters with regard to the variables applied.
publishDate 2011
dc.date.none.fl_str_mv 2011-11-09
dc.type.driver.fl_str_mv info:eu-repo/semantics/article
info:eu-repo/semantics/publishedVersion
tratamento de efluentes; degradação anaeróbia; Saneamento
format article
status_str publishedVersion
dc.identifier.uri.fl_str_mv http://www.periodicos.uem.br/ojs/index.php/ActaSciTechnol/article/view/10353
10.4025/actascitechnol.v34i2.10353
url http://www.periodicos.uem.br/ojs/index.php/ActaSciTechnol/article/view/10353
identifier_str_mv 10.4025/actascitechnol.v34i2.10353
dc.language.iso.fl_str_mv por
eng
language por
eng
dc.relation.none.fl_str_mv http://www.periodicos.uem.br/ojs/index.php/ActaSciTechnol/article/view/10353/pdf
http://www.periodicos.uem.br/ojs/index.php/ActaSciTechnol/article/view/10353/pdf_1
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv application/pdf
application/pdf
dc.publisher.none.fl_str_mv Universidade Estadual De Maringá
publisher.none.fl_str_mv Universidade Estadual De Maringá
dc.source.none.fl_str_mv Acta Scientiarum. Technology; Vol 34 No 2 (2012); 141-147
Acta Scientiarum. Technology; v. 34 n. 2 (2012); 141-147
1806-2563
1807-8664
reponame:Acta scientiarum. Technology (Online)
instname:Universidade Estadual de Maringá (UEM)
instacron:UEM
instname_str Universidade Estadual de Maringá (UEM)
instacron_str UEM
institution UEM
reponame_str Acta scientiarum. Technology (Online)
collection Acta scientiarum. Technology (Online)
repository.name.fl_str_mv Acta scientiarum. Technology (Online) - Universidade Estadual de Maringá (UEM)
repository.mail.fl_str_mv ||actatech@uem.br
_version_ 1799315333883887616