Design of a low cost measurement system based on accelerometers for gait analysis - doi: 10.4025/actascitechnol.v36i1.18581

Detalhes bibliográficos
Autor(a) principal: Martínez-Solís, Fermín
Data de Publicação: 2014
Outros Autores: Vergara-Limon, Sergio, Vargas-Treviño, Aurora, Rodrigues-Lelis, José Maria, Claudio-Sánchez, Abraham, Vargas-Treviño, Marciano
Tipo de documento: Artigo
Idioma: por
eng
Título da fonte: Acta scientiarum. Technology (Online)
Texto Completo: http://www.periodicos.uem.br/ojs/index.php/ActaSciTechnol/article/view/18581
Resumo: Current research reports on the development of a portable electronic system to assess the kinematics of the lower limb joints at the sagittal plane. The electronic device characteristics and the different communication protocols to transfer data are also reported. Research obtained the hip and knee angles to analyze the lower limb kinematics during multiple gait cycles. Results showed that the movement patterns, found in the analysis made on people from central Mexico, were cyclical and alternating. The knee described a one third curve in flexion-extension movements just before the start of the flexion-extension curve in the swing phase. Moreover data obtained showed a correlation of movement between hip and knee during walking.  
id UEM-6_bc6ff28b71d73a9be7d12cfa62d61ecd
oai_identifier_str oai:periodicos.uem.br/ojs:article/18581
network_acronym_str UEM-6
network_name_str Acta scientiarum. Technology (Online)
repository_id_str
spelling Design of a low cost measurement system based on accelerometers for gait analysis - doi: 10.4025/actascitechnol.v36i1.18581Electronic systemjointslower limbgaitmovement patterngait analysisCurrent research reports on the development of a portable electronic system to assess the kinematics of the lower limb joints at the sagittal plane. The electronic device characteristics and the different communication protocols to transfer data are also reported. Research obtained the hip and knee angles to analyze the lower limb kinematics during multiple gait cycles. Results showed that the movement patterns, found in the analysis made on people from central Mexico, were cyclical and alternating. The knee described a one third curve in flexion-extension movements just before the start of the flexion-extension curve in the swing phase. Moreover data obtained showed a correlation of movement between hip and knee during walking.  Universidade Estadual De Maringá2014-01-07info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersionacceleration polygonapplication/pdfapplication/pdfhttp://www.periodicos.uem.br/ojs/index.php/ActaSciTechnol/article/view/1858110.4025/actascitechnol.v36i1.18581Acta Scientiarum. Technology; Vol 36 No 1 (2014); 101-121Acta Scientiarum. Technology; v. 36 n. 1 (2014); 101-1211806-25631807-8664reponame:Acta scientiarum. Technology (Online)instname:Universidade Estadual de Maringá (UEM)instacron:UEMporenghttp://www.periodicos.uem.br/ojs/index.php/ActaSciTechnol/article/view/18581/pdfhttp://www.periodicos.uem.br/ojs/index.php/ActaSciTechnol/article/view/18581/pdf_1Martínez-Solís, FermínVergara-Limon, SergioVargas-Treviño, AuroraRodrigues-Lelis, José MariaClaudio-Sánchez, AbrahamVargas-Treviño, Marcianoinfo:eu-repo/semantics/openAccess2014-04-10T07:53:24Zoai:periodicos.uem.br/ojs:article/18581Revistahttps://www.periodicos.uem.br/ojs/index.php/ActaSciTechnol/indexPUBhttps://www.periodicos.uem.br/ojs/index.php/ActaSciTechnol/oai||actatech@uem.br1807-86641806-2563opendoar:2014-04-10T07:53:24Acta scientiarum. Technology (Online) - Universidade Estadual de Maringá (UEM)false
dc.title.none.fl_str_mv Design of a low cost measurement system based on accelerometers for gait analysis - doi: 10.4025/actascitechnol.v36i1.18581
title Design of a low cost measurement system based on accelerometers for gait analysis - doi: 10.4025/actascitechnol.v36i1.18581
spellingShingle Design of a low cost measurement system based on accelerometers for gait analysis - doi: 10.4025/actascitechnol.v36i1.18581
Martínez-Solís, Fermín
Electronic system
joints
lower limb
gait
movement pattern
gait analysis
title_short Design of a low cost measurement system based on accelerometers for gait analysis - doi: 10.4025/actascitechnol.v36i1.18581
title_full Design of a low cost measurement system based on accelerometers for gait analysis - doi: 10.4025/actascitechnol.v36i1.18581
title_fullStr Design of a low cost measurement system based on accelerometers for gait analysis - doi: 10.4025/actascitechnol.v36i1.18581
title_full_unstemmed Design of a low cost measurement system based on accelerometers for gait analysis - doi: 10.4025/actascitechnol.v36i1.18581
title_sort Design of a low cost measurement system based on accelerometers for gait analysis - doi: 10.4025/actascitechnol.v36i1.18581
author Martínez-Solís, Fermín
author_facet Martínez-Solís, Fermín
Vergara-Limon, Sergio
Vargas-Treviño, Aurora
Rodrigues-Lelis, José Maria
Claudio-Sánchez, Abraham
Vargas-Treviño, Marciano
author_role author
author2 Vergara-Limon, Sergio
Vargas-Treviño, Aurora
Rodrigues-Lelis, José Maria
Claudio-Sánchez, Abraham
Vargas-Treviño, Marciano
author2_role author
author
author
author
author
dc.contributor.author.fl_str_mv Martínez-Solís, Fermín
Vergara-Limon, Sergio
Vargas-Treviño, Aurora
Rodrigues-Lelis, José Maria
Claudio-Sánchez, Abraham
Vargas-Treviño, Marciano
dc.subject.por.fl_str_mv Electronic system
joints
lower limb
gait
movement pattern
gait analysis
topic Electronic system
joints
lower limb
gait
movement pattern
gait analysis
description Current research reports on the development of a portable electronic system to assess the kinematics of the lower limb joints at the sagittal plane. The electronic device characteristics and the different communication protocols to transfer data are also reported. Research obtained the hip and knee angles to analyze the lower limb kinematics during multiple gait cycles. Results showed that the movement patterns, found in the analysis made on people from central Mexico, were cyclical and alternating. The knee described a one third curve in flexion-extension movements just before the start of the flexion-extension curve in the swing phase. Moreover data obtained showed a correlation of movement between hip and knee during walking.  
publishDate 2014
dc.date.none.fl_str_mv 2014-01-07
dc.type.driver.fl_str_mv info:eu-repo/semantics/article
info:eu-repo/semantics/publishedVersion
acceleration polygon
format article
status_str publishedVersion
dc.identifier.uri.fl_str_mv http://www.periodicos.uem.br/ojs/index.php/ActaSciTechnol/article/view/18581
10.4025/actascitechnol.v36i1.18581
url http://www.periodicos.uem.br/ojs/index.php/ActaSciTechnol/article/view/18581
identifier_str_mv 10.4025/actascitechnol.v36i1.18581
dc.language.iso.fl_str_mv por
eng
language por
eng
dc.relation.none.fl_str_mv http://www.periodicos.uem.br/ojs/index.php/ActaSciTechnol/article/view/18581/pdf
http://www.periodicos.uem.br/ojs/index.php/ActaSciTechnol/article/view/18581/pdf_1
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv application/pdf
application/pdf
dc.publisher.none.fl_str_mv Universidade Estadual De Maringá
publisher.none.fl_str_mv Universidade Estadual De Maringá
dc.source.none.fl_str_mv Acta Scientiarum. Technology; Vol 36 No 1 (2014); 101-121
Acta Scientiarum. Technology; v. 36 n. 1 (2014); 101-121
1806-2563
1807-8664
reponame:Acta scientiarum. Technology (Online)
instname:Universidade Estadual de Maringá (UEM)
instacron:UEM
instname_str Universidade Estadual de Maringá (UEM)
instacron_str UEM
institution UEM
reponame_str Acta scientiarum. Technology (Online)
collection Acta scientiarum. Technology (Online)
repository.name.fl_str_mv Acta scientiarum. Technology (Online) - Universidade Estadual de Maringá (UEM)
repository.mail.fl_str_mv ||actatech@uem.br
_version_ 1799315335032078336