Accuracy of Cone Beam Computed Tomography in the Assessment of Mandibular Molar Furcation Defects

Detalhes bibliográficos
Autor(a) principal: Alzwiri, Abdalwhab
Data de Publicação: 2022
Outros Autores: Ismail, Hesham Shokry, Patil, Santosh R.
Tipo de documento: Artigo
Idioma: eng
Título da fonte: Pesquisa Brasileira em Odontopediatria e Clínica Integrada (Online)
Texto Completo: https://revista.uepb.edu.br/PBOCI/article/view/1068
Resumo: Objective: To evaluate the accuracy of cone-beam computed tomography (CBCT) in the assessment of mandibular molar furcation defects. Material and Methods: Thirty patients with furcation defects were selected, oral hygiene instructions, scaling, and root planing with ultrasonic devices and hand instruments and occlusal adjustments were performed. Pre-surgical clinical measurements were carried out at the buccal aspect of the selected mandibular molars. The horizontal furcation measurements were measured with a Nabers Probe starting at the furcation entrance to the greatest horizontal depth. The degree of furcation involvement was graded from 0 to III. Bone loss in the horizontal and vertical direction and the width of the furcation entrance were measured on CBCT and after reflecting the full-thickness flap and debridement of the defects. The data were analyzed using t-test and Pearson’s correlation coefficient. Results: The width of furcation entrance in clinical method was 3.27 ± 0.77, while in CBCT method was 3.35 ± 0.71, clinically the vertical bone loss was 3.61±1.09, while in CBCT was 3.57 ± 1.15, horizontal bone loss in  clinical method was 5.08 ± 2.21, while in CBCT was 5.11 ± 2.23. No significant difference between the two methods was noted, and a high correlation between the two methods was observed. With regards to the agreement between the two methods of assessment, the width of furcation entrance revealed a difference between the two methods by 0.08 ± 0.21, while vertical bone loss showed difference between the two methods by -0.04 ± 0.19, the horizontal bone loss showed a mean difference between the two methods by 0.03 ± 0.21. Conclusion: CBCT provided high accuracy for the furcation involvement detection and anatomy of surrounding periodontal tissues.
id UEPB-4_5d97ad87979f3642e710a9a5f78e9701
oai_identifier_str oai:ojs.pkp.sfu.ca:article/1068
network_acronym_str UEPB-4
network_name_str Pesquisa Brasileira em Odontopediatria e Clínica Integrada (Online)
repository_id_str
spelling Accuracy of Cone Beam Computed Tomography in the Assessment of Mandibular Molar Furcation DefectsCone-Beam Computed TomographyFurcation DefectsMolarObjective: To evaluate the accuracy of cone-beam computed tomography (CBCT) in the assessment of mandibular molar furcation defects. Material and Methods: Thirty patients with furcation defects were selected, oral hygiene instructions, scaling, and root planing with ultrasonic devices and hand instruments and occlusal adjustments were performed. Pre-surgical clinical measurements were carried out at the buccal aspect of the selected mandibular molars. The horizontal furcation measurements were measured with a Nabers Probe starting at the furcation entrance to the greatest horizontal depth. The degree of furcation involvement was graded from 0 to III. Bone loss in the horizontal and vertical direction and the width of the furcation entrance were measured on CBCT and after reflecting the full-thickness flap and debridement of the defects. The data were analyzed using t-test and Pearson’s correlation coefficient. Results: The width of furcation entrance in clinical method was 3.27 ± 0.77, while in CBCT method was 3.35 ± 0.71, clinically the vertical bone loss was 3.61±1.09, while in CBCT was 3.57 ± 1.15, horizontal bone loss in  clinical method was 5.08 ± 2.21, while in CBCT was 5.11 ± 2.23. No significant difference between the two methods was noted, and a high correlation between the two methods was observed. With regards to the agreement between the two methods of assessment, the width of furcation entrance revealed a difference between the two methods by 0.08 ± 0.21, while vertical bone loss showed difference between the two methods by -0.04 ± 0.19, the horizontal bone loss showed a mean difference between the two methods by 0.03 ± 0.21. Conclusion: CBCT provided high accuracy for the furcation involvement detection and anatomy of surrounding periodontal tissues.EDUEPB - EDITORA DA UNIVERSIDADE ESTADUAL DA PARAÍBA2022-03-17info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersionapplication/pdfhttps://revista.uepb.edu.br/PBOCI/article/view/1068Pesquisa Brasileira em Odontopediatria e Clínica Integrada; Vol. 20 (2020); e4853Pesquisa Brasileira em Odontopediatria e Clínica Integrada; v. 20 (2020); e48531983-46321519-0501reponame:Pesquisa Brasileira em Odontopediatria e Clínica Integrada (Online)instname:Universidade Estadual da Paraíba (UEPB)instacron:UEPBenghttps://revista.uepb.edu.br/PBOCI/article/view/1068/786Copyright (c) 2022 Pesquisa Brasileira em Odontopediatria e Clínica Integradahttps://creativecommons.org/licenses/by-nc/4.0info:eu-repo/semantics/openAccessAlzwiri, Abdalwhab Ismail, Hesham Shokry Patil, Santosh R. 2022-03-17T12:05:50Zoai:ojs.pkp.sfu.ca:article/1068Revistahttps://revista.uepb.edu.br/PBOCI/PUBhttps://revista.uepb.edu.br/PBOCI/oaipboci.editoria@gmail.com || alessandrouepb@gmail.com1983-46321519-0501opendoar:2022-03-17T12:05:50Pesquisa Brasileira em Odontopediatria e Clínica Integrada (Online) - Universidade Estadual da Paraíba (UEPB)false
dc.title.none.fl_str_mv Accuracy of Cone Beam Computed Tomography in the Assessment of Mandibular Molar Furcation Defects
title Accuracy of Cone Beam Computed Tomography in the Assessment of Mandibular Molar Furcation Defects
spellingShingle Accuracy of Cone Beam Computed Tomography in the Assessment of Mandibular Molar Furcation Defects
Alzwiri, Abdalwhab
Cone-Beam Computed Tomography
Furcation Defects
Molar
title_short Accuracy of Cone Beam Computed Tomography in the Assessment of Mandibular Molar Furcation Defects
title_full Accuracy of Cone Beam Computed Tomography in the Assessment of Mandibular Molar Furcation Defects
title_fullStr Accuracy of Cone Beam Computed Tomography in the Assessment of Mandibular Molar Furcation Defects
title_full_unstemmed Accuracy of Cone Beam Computed Tomography in the Assessment of Mandibular Molar Furcation Defects
title_sort Accuracy of Cone Beam Computed Tomography in the Assessment of Mandibular Molar Furcation Defects
author Alzwiri, Abdalwhab
author_facet Alzwiri, Abdalwhab
Ismail, Hesham Shokry
Patil, Santosh R.
author_role author
author2 Ismail, Hesham Shokry
Patil, Santosh R.
author2_role author
author
dc.contributor.author.fl_str_mv Alzwiri, Abdalwhab
Ismail, Hesham Shokry
Patil, Santosh R.
dc.subject.por.fl_str_mv Cone-Beam Computed Tomography
Furcation Defects
Molar
topic Cone-Beam Computed Tomography
Furcation Defects
Molar
description Objective: To evaluate the accuracy of cone-beam computed tomography (CBCT) in the assessment of mandibular molar furcation defects. Material and Methods: Thirty patients with furcation defects were selected, oral hygiene instructions, scaling, and root planing with ultrasonic devices and hand instruments and occlusal adjustments were performed. Pre-surgical clinical measurements were carried out at the buccal aspect of the selected mandibular molars. The horizontal furcation measurements were measured with a Nabers Probe starting at the furcation entrance to the greatest horizontal depth. The degree of furcation involvement was graded from 0 to III. Bone loss in the horizontal and vertical direction and the width of the furcation entrance were measured on CBCT and after reflecting the full-thickness flap and debridement of the defects. The data were analyzed using t-test and Pearson’s correlation coefficient. Results: The width of furcation entrance in clinical method was 3.27 ± 0.77, while in CBCT method was 3.35 ± 0.71, clinically the vertical bone loss was 3.61±1.09, while in CBCT was 3.57 ± 1.15, horizontal bone loss in  clinical method was 5.08 ± 2.21, while in CBCT was 5.11 ± 2.23. No significant difference between the two methods was noted, and a high correlation between the two methods was observed. With regards to the agreement between the two methods of assessment, the width of furcation entrance revealed a difference between the two methods by 0.08 ± 0.21, while vertical bone loss showed difference between the two methods by -0.04 ± 0.19, the horizontal bone loss showed a mean difference between the two methods by 0.03 ± 0.21. Conclusion: CBCT provided high accuracy for the furcation involvement detection and anatomy of surrounding periodontal tissues.
publishDate 2022
dc.date.none.fl_str_mv 2022-03-17
dc.type.driver.fl_str_mv info:eu-repo/semantics/article
info:eu-repo/semantics/publishedVersion
format article
status_str publishedVersion
dc.identifier.uri.fl_str_mv https://revista.uepb.edu.br/PBOCI/article/view/1068
url https://revista.uepb.edu.br/PBOCI/article/view/1068
dc.language.iso.fl_str_mv eng
language eng
dc.relation.none.fl_str_mv https://revista.uepb.edu.br/PBOCI/article/view/1068/786
dc.rights.driver.fl_str_mv Copyright (c) 2022 Pesquisa Brasileira em Odontopediatria e Clínica Integrada
https://creativecommons.org/licenses/by-nc/4.0
info:eu-repo/semantics/openAccess
rights_invalid_str_mv Copyright (c) 2022 Pesquisa Brasileira em Odontopediatria e Clínica Integrada
https://creativecommons.org/licenses/by-nc/4.0
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv application/pdf
dc.publisher.none.fl_str_mv EDUEPB - EDITORA DA UNIVERSIDADE ESTADUAL DA PARAÍBA
publisher.none.fl_str_mv EDUEPB - EDITORA DA UNIVERSIDADE ESTADUAL DA PARAÍBA
dc.source.none.fl_str_mv Pesquisa Brasileira em Odontopediatria e Clínica Integrada; Vol. 20 (2020); e4853
Pesquisa Brasileira em Odontopediatria e Clínica Integrada; v. 20 (2020); e4853
1983-4632
1519-0501
reponame:Pesquisa Brasileira em Odontopediatria e Clínica Integrada (Online)
instname:Universidade Estadual da Paraíba (UEPB)
instacron:UEPB
instname_str Universidade Estadual da Paraíba (UEPB)
instacron_str UEPB
institution UEPB
reponame_str Pesquisa Brasileira em Odontopediatria e Clínica Integrada (Online)
collection Pesquisa Brasileira em Odontopediatria e Clínica Integrada (Online)
repository.name.fl_str_mv Pesquisa Brasileira em Odontopediatria e Clínica Integrada (Online) - Universidade Estadual da Paraíba (UEPB)
repository.mail.fl_str_mv pboci.editoria@gmail.com || alessandrouepb@gmail.com
_version_ 1803387863308435456