ÁREA ELEMENTAR REPRESENTATIVA PARA MEDIDAS DA DENSIDADE E POROSIDADE DO SOLO USANDO TOMOGRAFIA COMPUTADORIZADA DE RAIOS GAMA

Detalhes bibliográficos
Autor(a) principal: Borges, Jaqueline Aparecida Ribaski
Data de Publicação: 2011
Tipo de documento: Dissertação
Idioma: por
Título da fonte: Biblioteca Digital de Teses e Dissertações da UEPG
Texto Completo: http://tede2.uepg.br/jspui/handle/prefix/888
Resumo: Computed tomography (CT) is a technique that provides images of sample cross sections of porous media. The technique has shown efficient to investigate different soil physical phenomena since its first use in soil science in 1982. One of the most widely investigated issues in physics applied to porous media regards the definition of representative elementary areas (REA) to measure the soil physical properties. REA is related to the minimum area of a sample needed to represent its characteristics of interest. The objective of this work was to define REAs to be adopted for density and porosity measurements in clod samples of a clay soil. The equipment used was a first generation tomograph with 241Am source, with millimetric resolution (1.1 x 1.1 mm2). The photon detection was made with a plane NaI(Tl) solid crystal scintillator. Clods (18 samples) were also submitted to the clod method (standard method) in order to determine its. In order to reconstruct tomographic images, the program Microvis developed by Embrapa/CNPDIA was used. Concentric square areas with sizes ranging from 1.2 to 1162.8 mm2 were selected. To define REA for the following criteria were adopted: average value relative deviation between the last and each of the remaining areas not superior to 5%, 4%, 3%, 2% and 1%; and 2) that at least three consecutive areas cannot differ among themselves, using the variation criterion in item 1. The measurements through the clod method presented variation coefficient of 3.8%. Thus, it was considered that the REA was reached at the 4% variation criterion. For the criterion is similar, but the relative deviation considered cannot be superior to 10%. The REA defined for measurements corresponds to 640.1 mm2. On the other hand, for the REA found was 882.1 mm2. So, in order to carry out representative measurements of these two physical properties the REA must be at least 882.1 mm2. Key-words: Representative Measurements. Tomographic Images. Porous Media.
id UEPG_2834bec04b0bdae46d066c997e48a0bc
oai_identifier_str oai:tede2.uepg.br:prefix/888
network_acronym_str UEPG
network_name_str Biblioteca Digital de Teses e Dissertações da UEPG
repository_id_str
spelling Pires, Luiz FernandoCPF:02069122930Saab, Sérgio da CostaCPF:40886700191http://buscatextual.cnpq.br/buscatextual/visualizacv.do?id=K4727955P9Rosa, Jadir AparecidoCPF:68613970915http://buscatextual.cnpq.br/buscatextual/visualizacv.do?id=K4788851U0CPF:00943729939http://buscatextual.cnpq.br/buscatextual/visualizacv.do?id=K4246708E2Borges, Jaqueline Aparecida Ribaski2017-07-21T19:26:00Z2011-05-062017-07-21T19:26:00Z2011-03-11BORGES, Jaqueline Aparecida Ribaski. ÁREA ELEMENTAR REPRESENTATIVA PARA MEDIDAS DA DENSIDADE E POROSIDADE DO SOLO USANDO TOMOGRAFIA COMPUTADORIZADA DE RAIOS GAMA. 2011. 88 f. Dissertação (Mestrado em Fisica) - UNIVERSIDADE ESTADUAL DE PONTA GROSSA, Ponta Grossa, 2011.http://tede2.uepg.br/jspui/handle/prefix/888Computed tomography (CT) is a technique that provides images of sample cross sections of porous media. The technique has shown efficient to investigate different soil physical phenomena since its first use in soil science in 1982. One of the most widely investigated issues in physics applied to porous media regards the definition of representative elementary areas (REA) to measure the soil physical properties. REA is related to the minimum area of a sample needed to represent its characteristics of interest. The objective of this work was to define REAs to be adopted for density and porosity measurements in clod samples of a clay soil. The equipment used was a first generation tomograph with 241Am source, with millimetric resolution (1.1 x 1.1 mm2). The photon detection was made with a plane NaI(Tl) solid crystal scintillator. Clods (18 samples) were also submitted to the clod method (standard method) in order to determine its. In order to reconstruct tomographic images, the program Microvis developed by Embrapa/CNPDIA was used. Concentric square areas with sizes ranging from 1.2 to 1162.8 mm2 were selected. To define REA for the following criteria were adopted: average value relative deviation between the last and each of the remaining areas not superior to 5%, 4%, 3%, 2% and 1%; and 2) that at least three consecutive areas cannot differ among themselves, using the variation criterion in item 1. The measurements through the clod method presented variation coefficient of 3.8%. Thus, it was considered that the REA was reached at the 4% variation criterion. For the criterion is similar, but the relative deviation considered cannot be superior to 10%. The REA defined for measurements corresponds to 640.1 mm2. On the other hand, for the REA found was 882.1 mm2. So, in order to carry out representative measurements of these two physical properties the REA must be at least 882.1 mm2. Key-words: Representative Measurements. Tomographic Images. Porous Media.A Tomografia Computadorizada (TC) trata-se de uma técnica que fornece imagens de seções transversais de amostras de meios porosos. A técnica tem se mostrado eficaz na investigação de diversos fenômenos físicos do solo desde sua primeira aplicação nessa área em 1982. Uma questão amplamente investigada em física aplicada a meios porosos diz respeito à definição de áreas elementares representativas (AER) para medidas de propriedades físicas do solo. A AER está relacionada com a área mínima de uma amostra, necessária para representar suas características de interesse. O objetivo deste trabalho foi definir AERs a serem adotadas para medidas da densidade e porosidade de amostras de torrão de um solo de textura argilosa. Para isso, utilizou-se um tomógrafo de primeira geração, equipado com fonte de 241Am com resolução da ordem de milímetros (1,1 x 1,1 mm2). A detecção dos fótons foi feita com um detector de cintilação sólida de NaI(Tl) do tipo plano. Os torrões (18 amostras) também foram submetidos ao método do torrão parafinado (TP, método padrão) para determinação da sua Para reconstrução das imagens tomográficas utilizou-se o programa Microvis desenvolvido pela Embrapa/CNPDIA. Nestas imagens foram selecionadas áreas quadrangulares concêntricas com dimensões variando de 1,2 até 1162,8 mm2. Para definição da AER para foram utilizados os seguintes critérios: 1) desvio relativo do valor médio entre a última e cada uma das demais áreas não superior a 5%, 4%, 3%, 2% e 1% e 2) que pelo menos três áreas consecutivas não devem diferir entre si, utilizando o critério de variação do item 1. As medidas de pelo método do TP apresentaram coeficiente de variação da ordem de 3,8%. Assim, considerou-se que a AER foi atingida no critério de 4% de variação. Para o critério é semelhante, mas o desvio relativo considerado não deve ser superior a 10%. A AER definida para medidas de corresponde a 640,1 mm2. Para a AER encontrada é de 882,1 mm2. Portanto, para a realização de medidas representativas destas duas propriedades físicas, a AER deve ser de pelo menos 882,1 mm2. Palavras-chave: Medidas Representativas. Imagens Tomográficas. Meios Porosos.Made available in DSpace on 2017-07-21T19:26:00Z (GMT). No. of bitstreams: 1 Jaqueline Borges.pdf: 2739563 bytes, checksum: d03b8e7308ae59a90b2d872a90cad206 (MD5) Previous issue date: 2011-03-11Coordenação de Aperfeiçoamento de Pessoal de Nível Superiorapplication/pdfporUNIVERSIDADE ESTADUAL DE PONTA GROSSAPrograma de Pós-Graduação em CiênciasUEPGBRFisicamedidas representativasimagens tomográficasmeios porososrepresentative measurementstomographic imagesporous mediaCNPQ::CIENCIAS EXATAS E DA TERRA::FISICAÁREA ELEMENTAR REPRESENTATIVA PARA MEDIDAS DA DENSIDADE E POROSIDADE DO SOLO USANDO TOMOGRAFIA COMPUTADORIZADA DE RAIOS GAMAinfo:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/masterThesisinfo:eu-repo/semantics/openAccessreponame:Biblioteca Digital de Teses e Dissertações da UEPGinstname:Universidade Estadual de Ponta Grossa (UEPG)instacron:UEPGORIGINALJaqueline Borges.pdfapplication/pdf2739563http://tede2.uepg.br/jspui/bitstream/prefix/888/1/Jaqueline%20Borges.pdfd03b8e7308ae59a90b2d872a90cad206MD51prefix/8882017-07-21 16:26:00.355oai:tede2.uepg.br:prefix/888Biblioteca Digital de Teses e Dissertaçõeshttps://tede2.uepg.br/jspui/PUBhttp://tede2.uepg.br/oai/requestbicen@uepg.br||mv_fidelis@yahoo.com.bropendoar:2017-07-21T19:26Biblioteca Digital de Teses e Dissertações da UEPG - Universidade Estadual de Ponta Grossa (UEPG)false
dc.title.por.fl_str_mv ÁREA ELEMENTAR REPRESENTATIVA PARA MEDIDAS DA DENSIDADE E POROSIDADE DO SOLO USANDO TOMOGRAFIA COMPUTADORIZADA DE RAIOS GAMA
title ÁREA ELEMENTAR REPRESENTATIVA PARA MEDIDAS DA DENSIDADE E POROSIDADE DO SOLO USANDO TOMOGRAFIA COMPUTADORIZADA DE RAIOS GAMA
spellingShingle ÁREA ELEMENTAR REPRESENTATIVA PARA MEDIDAS DA DENSIDADE E POROSIDADE DO SOLO USANDO TOMOGRAFIA COMPUTADORIZADA DE RAIOS GAMA
Borges, Jaqueline Aparecida Ribaski
medidas representativas
imagens tomográficas
meios porosos
representative measurements
tomographic images
porous media
CNPQ::CIENCIAS EXATAS E DA TERRA::FISICA
title_short ÁREA ELEMENTAR REPRESENTATIVA PARA MEDIDAS DA DENSIDADE E POROSIDADE DO SOLO USANDO TOMOGRAFIA COMPUTADORIZADA DE RAIOS GAMA
title_full ÁREA ELEMENTAR REPRESENTATIVA PARA MEDIDAS DA DENSIDADE E POROSIDADE DO SOLO USANDO TOMOGRAFIA COMPUTADORIZADA DE RAIOS GAMA
title_fullStr ÁREA ELEMENTAR REPRESENTATIVA PARA MEDIDAS DA DENSIDADE E POROSIDADE DO SOLO USANDO TOMOGRAFIA COMPUTADORIZADA DE RAIOS GAMA
title_full_unstemmed ÁREA ELEMENTAR REPRESENTATIVA PARA MEDIDAS DA DENSIDADE E POROSIDADE DO SOLO USANDO TOMOGRAFIA COMPUTADORIZADA DE RAIOS GAMA
title_sort ÁREA ELEMENTAR REPRESENTATIVA PARA MEDIDAS DA DENSIDADE E POROSIDADE DO SOLO USANDO TOMOGRAFIA COMPUTADORIZADA DE RAIOS GAMA
author Borges, Jaqueline Aparecida Ribaski
author_facet Borges, Jaqueline Aparecida Ribaski
author_role author
dc.contributor.advisor1.fl_str_mv Pires, Luiz Fernando
dc.contributor.advisor1ID.fl_str_mv CPF:02069122930
dc.contributor.referee1.fl_str_mv Saab, Sérgio da Costa
dc.contributor.referee1ID.fl_str_mv CPF:40886700191
dc.contributor.referee1Lattes.fl_str_mv http://buscatextual.cnpq.br/buscatextual/visualizacv.do?id=K4727955P9
dc.contributor.referee2.fl_str_mv Rosa, Jadir Aparecido
dc.contributor.referee2ID.fl_str_mv CPF:68613970915
dc.contributor.referee2Lattes.fl_str_mv http://buscatextual.cnpq.br/buscatextual/visualizacv.do?id=K4788851U0
dc.contributor.authorID.fl_str_mv CPF:00943729939
dc.contributor.authorLattes.fl_str_mv http://buscatextual.cnpq.br/buscatextual/visualizacv.do?id=K4246708E2
dc.contributor.author.fl_str_mv Borges, Jaqueline Aparecida Ribaski
contributor_str_mv Pires, Luiz Fernando
Saab, Sérgio da Costa
Rosa, Jadir Aparecido
dc.subject.por.fl_str_mv medidas representativas
imagens tomográficas
meios porosos
topic medidas representativas
imagens tomográficas
meios porosos
representative measurements
tomographic images
porous media
CNPQ::CIENCIAS EXATAS E DA TERRA::FISICA
dc.subject.eng.fl_str_mv representative measurements
tomographic images
porous media
dc.subject.cnpq.fl_str_mv CNPQ::CIENCIAS EXATAS E DA TERRA::FISICA
description Computed tomography (CT) is a technique that provides images of sample cross sections of porous media. The technique has shown efficient to investigate different soil physical phenomena since its first use in soil science in 1982. One of the most widely investigated issues in physics applied to porous media regards the definition of representative elementary areas (REA) to measure the soil physical properties. REA is related to the minimum area of a sample needed to represent its characteristics of interest. The objective of this work was to define REAs to be adopted for density and porosity measurements in clod samples of a clay soil. The equipment used was a first generation tomograph with 241Am source, with millimetric resolution (1.1 x 1.1 mm2). The photon detection was made with a plane NaI(Tl) solid crystal scintillator. Clods (18 samples) were also submitted to the clod method (standard method) in order to determine its. In order to reconstruct tomographic images, the program Microvis developed by Embrapa/CNPDIA was used. Concentric square areas with sizes ranging from 1.2 to 1162.8 mm2 were selected. To define REA for the following criteria were adopted: average value relative deviation between the last and each of the remaining areas not superior to 5%, 4%, 3%, 2% and 1%; and 2) that at least three consecutive areas cannot differ among themselves, using the variation criterion in item 1. The measurements through the clod method presented variation coefficient of 3.8%. Thus, it was considered that the REA was reached at the 4% variation criterion. For the criterion is similar, but the relative deviation considered cannot be superior to 10%. The REA defined for measurements corresponds to 640.1 mm2. On the other hand, for the REA found was 882.1 mm2. So, in order to carry out representative measurements of these two physical properties the REA must be at least 882.1 mm2. Key-words: Representative Measurements. Tomographic Images. Porous Media.
publishDate 2011
dc.date.available.fl_str_mv 2011-05-06
2017-07-21T19:26:00Z
dc.date.issued.fl_str_mv 2011-03-11
dc.date.accessioned.fl_str_mv 2017-07-21T19:26:00Z
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
dc.type.driver.fl_str_mv info:eu-repo/semantics/masterThesis
format masterThesis
status_str publishedVersion
dc.identifier.citation.fl_str_mv BORGES, Jaqueline Aparecida Ribaski. ÁREA ELEMENTAR REPRESENTATIVA PARA MEDIDAS DA DENSIDADE E POROSIDADE DO SOLO USANDO TOMOGRAFIA COMPUTADORIZADA DE RAIOS GAMA. 2011. 88 f. Dissertação (Mestrado em Fisica) - UNIVERSIDADE ESTADUAL DE PONTA GROSSA, Ponta Grossa, 2011.
dc.identifier.uri.fl_str_mv http://tede2.uepg.br/jspui/handle/prefix/888
identifier_str_mv BORGES, Jaqueline Aparecida Ribaski. ÁREA ELEMENTAR REPRESENTATIVA PARA MEDIDAS DA DENSIDADE E POROSIDADE DO SOLO USANDO TOMOGRAFIA COMPUTADORIZADA DE RAIOS GAMA. 2011. 88 f. Dissertação (Mestrado em Fisica) - UNIVERSIDADE ESTADUAL DE PONTA GROSSA, Ponta Grossa, 2011.
url http://tede2.uepg.br/jspui/handle/prefix/888
dc.language.iso.fl_str_mv por
language por
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv application/pdf
dc.publisher.none.fl_str_mv UNIVERSIDADE ESTADUAL DE PONTA GROSSA
dc.publisher.program.fl_str_mv Programa de Pós-Graduação em Ciências
dc.publisher.initials.fl_str_mv UEPG
dc.publisher.country.fl_str_mv BR
dc.publisher.department.fl_str_mv Fisica
publisher.none.fl_str_mv UNIVERSIDADE ESTADUAL DE PONTA GROSSA
dc.source.none.fl_str_mv reponame:Biblioteca Digital de Teses e Dissertações da UEPG
instname:Universidade Estadual de Ponta Grossa (UEPG)
instacron:UEPG
instname_str Universidade Estadual de Ponta Grossa (UEPG)
instacron_str UEPG
institution UEPG
reponame_str Biblioteca Digital de Teses e Dissertações da UEPG
collection Biblioteca Digital de Teses e Dissertações da UEPG
bitstream.url.fl_str_mv http://tede2.uepg.br/jspui/bitstream/prefix/888/1/Jaqueline%20Borges.pdf
bitstream.checksum.fl_str_mv d03b8e7308ae59a90b2d872a90cad206
bitstream.checksumAlgorithm.fl_str_mv MD5
repository.name.fl_str_mv Biblioteca Digital de Teses e Dissertações da UEPG - Universidade Estadual de Ponta Grossa (UEPG)
repository.mail.fl_str_mv bicen@uepg.br||mv_fidelis@yahoo.com.br