Resumo: The objective of this study was to compare the bleaching efficacy and tooth sensitivity (TS) of two hydrogen peroxide (HP) concentrations (20 and 35%) used for in-office bleaching associated or not with a LED/laser light activation. Seventy-seven patients with right upper canine darker than A3 were selected to participate in this single-blind randomized trial. The participants were distributed in four groups: bleaching with 20% HP alone; 20% HP + LED/laser; 35% HP alone [35%]; 35% HP + LED/laser. The buccal surfaces of the anterior teeth were bleached, in two sessions, using a 35% or 20% HP gel with one week interval. At each session, three applications of 15 min were used. For the light activated groups, the LED/laser energy (Whitening Laser Light Plus, DMC) was employed according to the manufacturer’s instructions. The color change was evaluated by using the Vitapan Classical Shade Guide and the VITA Easyshade Spectrophotometer (Vita Zahnfabrik) 1 week and 1 month post bleaching. Participants recorded TS with a five-point verbal and VAS scales, and identified the sensitive tooth. Color change was analyzed by ANOVA and Tukey’s tests (α = 0.05). The absolute risk of TS and TS intensity evaluated by Fisher’s exact test and Kruskall Wallis test, respectively (α = 0.05). All groups achieved the same level of whitening at both evaluation periods, except for the 20% HP group, which showed the lowest amount of whitening as detected by the subjective evaluation. The use of light did not increase absolute risk of TS and TS intensity during and after bleaching for both scales. The premolars were the least sensitive. It can be concluded that the use of LED/laser light activation was able to increase the amount of whitening produced with the 20% HP without increasing TS, but this association was not useful for the 35% HP gel.
id UEPG_d381e4c6f8402b71fedfe95a4db48a5c
oai_identifier_str oai:tede2.uepg.br:prefix/1822
network_acronym_str UEPG
network_name_str Biblioteca Digital de Teses e Dissertações da UEPG
repository_id_str
spelling Reis, AlessandraCPF:25713648800REIS, A.Wang, LindaCPF:20641450877http://buscatextual.cnpq.br/buscatextual/visualizacv.do?id=K4773117P6Schroeder, Marcos D'oliveiraCPF:01484754778http://buscatextual.cnpq.br/buscatextual/visualizacv.do?id=K4703400J2Calixto, Abraham LincolnCPF:09610436870http://buscatextual.cnpq.br/buscatextual/visualizacv.do?id=K4769030H2Gomes, João CarlosCPF:33867771987http://buscatextual.cnpq.br/buscatextual/visualizacv.do?id=K4793213H4CPF:25713648800http://buscatextual.cnpq.br/buscatextual/visualizacv.do?id=K4290906A6Serrano, Alexandra Patricia Mena2017-07-24T19:22:29Z2013-11-062017-07-24T19:22:29Z2013-07-19SERRANO, Alexandra Patricia Mena. Clinical efficacy of in-office bleaching using two concentrations of hydrogen peroxide with or without activation. 2013. 69 f. Tese (Doutorado em Clinica Integrada, Dentística Restauradora e Periodontia) - UNIVERSIDADE ESTADUAL DE PONTA GROSSA, Ponta Grossa, 2013.http://tede2.uepg.br/jspui/handle/prefix/1822The objective of this study was to compare the bleaching efficacy and tooth sensitivity (TS) of two hydrogen peroxide (HP) concentrations (20 and 35%) used for in-office bleaching associated or not with a LED/laser light activation. Seventy-seven patients with right upper canine darker than A3 were selected to participate in this single-blind randomized trial. The participants were distributed in four groups: bleaching with 20% HP alone; 20% HP + LED/laser; 35% HP alone [35%]; 35% HP + LED/laser. The buccal surfaces of the anterior teeth were bleached, in two sessions, using a 35% or 20% HP gel with one week interval. At each session, three applications of 15 min were used. For the light activated groups, the LED/laser energy (Whitening Laser Light Plus, DMC) was employed according to the manufacturer’s instructions. The color change was evaluated by using the Vitapan Classical Shade Guide and the VITA Easyshade Spectrophotometer (Vita Zahnfabrik) 1 week and 1 month post bleaching. Participants recorded TS with a five-point verbal and VAS scales, and identified the sensitive tooth. Color change was analyzed by ANOVA and Tukey’s tests (α = 0.05). The absolute risk of TS and TS intensity evaluated by Fisher’s exact test and Kruskall Wallis test, respectively (α = 0.05). All groups achieved the same level of whitening at both evaluation periods, except for the 20% HP group, which showed the lowest amount of whitening as detected by the subjective evaluation. The use of light did not increase absolute risk of TS and TS intensity during and after bleaching for both scales. The premolars were the least sensitive. It can be concluded that the use of LED/laser light activation was able to increase the amount of whitening produced with the 20% HP without increasing TS, but this association was not useful for the 35% HP gel.O objetivo deste estudo foi comparar a eficácia clareadora e a sensibilidade dental (SD) de duas concentrações (20% e 35%) de peróxido de hidrogênio (PH), utilizadas para o clareamento dental em consultório, associadas ou não a fonte de luz LED/laser. Setenta e sete pacientes com o canino superior direito mais escuro que A3 foram selecionados para participar neste estudo cego randomizado. Os participantes foram distribuídos em quatro grupos: clareamento com 20% PH sem luz [20%]; 20% PH com LED/laser; 35% PH sem luz [35%] e 35% PH com LED/laser. As superfície vestibulares dos dentes anteriores foram clareadas, em duas sessões, usando os geis de PH a 20% e 35% com uma semana de intervalo. Em cada sessão, três aplicações de 15 minutos foram realizadas. Para os grupos com ativação de luz, a fonte de energia LED/laser (Whitening Laser Light Plus, DMC) foi empregada de acordo com as instruções do fabricante. A mudança de cor foi avaliada pela escala de cor visual Vitapan Classical e pelo espectrofotômetro VITA Easyshade (Vita Zahnfabrik) 1 semana e 1 mês após o clareamento. Os participantes registraram a SD numa escala verbal de 5 pontos e na escala de VAS, e identificaram o elemento dentário sensível. A mudança de cor foi analisada pelos testes de ANOVA e Tukey (α = 0,05). O risco absoluto de SD e a intensidade de SD foram avaliados pelos testes de Fisher e Kruskall Wallis, respectivamente (α = 0,05). Todos os grupos alcançaram o mesmo nível de clareamento, exceto o grupo 20%, que demonstrou menores valores de mudança de cor detectados pela avaliação subjetiva nos dois tempos de avaliação. O uso de luz não aumentou a intensidade nem o risco absoluto de SD durante e depois do clareamento para ambas as escalas. Os premolares foram os dentes menos sensíveis. Pode ser concluído que o uso da ativação a fonte de luz LED/laser foi capaz de aumentar o clareamento produzido pelo gel de PH a 20% sem incrementar a SD, mas essa associação não foi útil para o gel de PH a 35%.Made available in DSpace on 2017-07-24T19:22:29Z (GMT). No. of bitstreams: 1 Alexandra Mena Serrano.pdf: 1057111 bytes, checksum: 4f3b7ca99bc8d5ac4bea8b11a5288ce7 (MD5) Previous issue date: 2013-07-19Coordenação de Aperfeiçoamento de Pessoal de Nível Superiorapplication/pdfporUNIVERSIDADE ESTADUAL DE PONTA GROSSAPrograma de Pós-Graduação em OdontologiaUEPGBRClinica Integrada, Dentística Restauradora e Periodontiaclareamento dentalensaio clínico controlado aleatóriosensibilidade da dentinatooth bleachingrandomized controlled clinical trialtooth sensitivityCNPQ::CIENCIAS DA SAUDE::ODONTOLOGIAEFICÁCIA CLÍNICA DO CLAREAMENTO EM CONSULTÓRIO USANDO DUAS CONCENTRAÇÕES DE PERÓXIDO DE HIDROGÊNIO COM E SEM ATIVAÇÃOClinical efficacy of in-office bleaching using two concentrations of hydrogen peroxide with or without activationinfo:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/doctoralThesisinfo:eu-repo/semantics/openAccessreponame:Biblioteca Digital de Teses e Dissertações da UEPGinstname:Universidade Estadual de Ponta Grossa (UEPG)instacron:UEPGORIGINALAlexandra Mena Serrano.pdfapplication/pdf1057111http://tede2.uepg.br/jspui/bitstream/prefix/1822/1/Alexandra%20Mena%20Serrano.pdf4f3b7ca99bc8d5ac4bea8b11a5288ce7MD51prefix/18222017-07-24 16:22:29.045oai:tede2.uepg.br:prefix/1822Biblioteca Digital de Teses e Dissertaçõeshttps://tede2.uepg.br/jspui/PUBhttp://tede2.uepg.br/oai/requestbicen@uepg.br||mv_fidelis@yahoo.com.bropendoar:2017-07-24T19:22:29Biblioteca Digital de Teses e Dissertações da UEPG - Universidade Estadual de Ponta Grossa (UEPG)false
dc.title.por.fl_str_mv EFICÁCIA CLÍNICA DO CLAREAMENTO EM CONSULTÓRIO USANDO DUAS CONCENTRAÇÕES DE PERÓXIDO DE HIDROGÊNIO COM E SEM ATIVAÇÃO
dc.title.alternative.eng.fl_str_mv Clinical efficacy of in-office bleaching using two concentrations of hydrogen peroxide with or without activation
title EFICÁCIA CLÍNICA DO CLAREAMENTO EM CONSULTÓRIO USANDO DUAS CONCENTRAÇÕES DE PERÓXIDO DE HIDROGÊNIO COM E SEM ATIVAÇÃO
spellingShingle EFICÁCIA CLÍNICA DO CLAREAMENTO EM CONSULTÓRIO USANDO DUAS CONCENTRAÇÕES DE PERÓXIDO DE HIDROGÊNIO COM E SEM ATIVAÇÃO
Serrano, Alexandra Patricia Mena
clareamento dental
ensaio clínico controlado aleatório
sensibilidade da dentina
tooth bleaching
randomized controlled clinical trial
tooth sensitivity
CNPQ::CIENCIAS DA SAUDE::ODONTOLOGIA
title_short EFICÁCIA CLÍNICA DO CLAREAMENTO EM CONSULTÓRIO USANDO DUAS CONCENTRAÇÕES DE PERÓXIDO DE HIDROGÊNIO COM E SEM ATIVAÇÃO
title_full EFICÁCIA CLÍNICA DO CLAREAMENTO EM CONSULTÓRIO USANDO DUAS CONCENTRAÇÕES DE PERÓXIDO DE HIDROGÊNIO COM E SEM ATIVAÇÃO
title_fullStr EFICÁCIA CLÍNICA DO CLAREAMENTO EM CONSULTÓRIO USANDO DUAS CONCENTRAÇÕES DE PERÓXIDO DE HIDROGÊNIO COM E SEM ATIVAÇÃO
title_full_unstemmed EFICÁCIA CLÍNICA DO CLAREAMENTO EM CONSULTÓRIO USANDO DUAS CONCENTRAÇÕES DE PERÓXIDO DE HIDROGÊNIO COM E SEM ATIVAÇÃO
title_sort EFICÁCIA CLÍNICA DO CLAREAMENTO EM CONSULTÓRIO USANDO DUAS CONCENTRAÇÕES DE PERÓXIDO DE HIDROGÊNIO COM E SEM ATIVAÇÃO
author Serrano, Alexandra Patricia Mena
author_facet Serrano, Alexandra Patricia Mena
author_role author
dc.contributor.advisor1.fl_str_mv Reis, Alessandra
dc.contributor.advisor1ID.fl_str_mv CPF:25713648800
dc.contributor.advisor1Lattes.fl_str_mv REIS, A.
dc.contributor.referee1.fl_str_mv Wang, Linda
dc.contributor.referee1ID.fl_str_mv CPF:20641450877
dc.contributor.referee1Lattes.fl_str_mv http://buscatextual.cnpq.br/buscatextual/visualizacv.do?id=K4773117P6
dc.contributor.referee2.fl_str_mv Schroeder, Marcos D'oliveira
dc.contributor.referee2ID.fl_str_mv CPF:01484754778
dc.contributor.referee2Lattes.fl_str_mv http://buscatextual.cnpq.br/buscatextual/visualizacv.do?id=K4703400J2
dc.contributor.referee3.fl_str_mv Calixto, Abraham Lincoln
dc.contributor.referee3ID.fl_str_mv CPF:09610436870
dc.contributor.referee3Lattes.fl_str_mv http://buscatextual.cnpq.br/buscatextual/visualizacv.do?id=K4769030H2
dc.contributor.referee4.fl_str_mv Gomes, João Carlos
dc.contributor.referee4ID.fl_str_mv CPF:33867771987
dc.contributor.referee4Lattes.fl_str_mv http://buscatextual.cnpq.br/buscatextual/visualizacv.do?id=K4793213H4
dc.contributor.authorID.fl_str_mv CPF:25713648800
dc.contributor.authorLattes.fl_str_mv http://buscatextual.cnpq.br/buscatextual/visualizacv.do?id=K4290906A6
dc.contributor.author.fl_str_mv Serrano, Alexandra Patricia Mena
contributor_str_mv Reis, Alessandra
Wang, Linda
Schroeder, Marcos D'oliveira
Calixto, Abraham Lincoln
Gomes, João Carlos
dc.subject.por.fl_str_mv clareamento dental
ensaio clínico controlado aleatório
sensibilidade da dentina
topic clareamento dental
ensaio clínico controlado aleatório
sensibilidade da dentina
tooth bleaching
randomized controlled clinical trial
tooth sensitivity
CNPQ::CIENCIAS DA SAUDE::ODONTOLOGIA
dc.subject.eng.fl_str_mv tooth bleaching
randomized controlled clinical trial
tooth sensitivity
dc.subject.cnpq.fl_str_mv CNPQ::CIENCIAS DA SAUDE::ODONTOLOGIA
description The objective of this study was to compare the bleaching efficacy and tooth sensitivity (TS) of two hydrogen peroxide (HP) concentrations (20 and 35%) used for in-office bleaching associated or not with a LED/laser light activation. Seventy-seven patients with right upper canine darker than A3 were selected to participate in this single-blind randomized trial. The participants were distributed in four groups: bleaching with 20% HP alone; 20% HP + LED/laser; 35% HP alone [35%]; 35% HP + LED/laser. The buccal surfaces of the anterior teeth were bleached, in two sessions, using a 35% or 20% HP gel with one week interval. At each session, three applications of 15 min were used. For the light activated groups, the LED/laser energy (Whitening Laser Light Plus, DMC) was employed according to the manufacturer’s instructions. The color change was evaluated by using the Vitapan Classical Shade Guide and the VITA Easyshade Spectrophotometer (Vita Zahnfabrik) 1 week and 1 month post bleaching. Participants recorded TS with a five-point verbal and VAS scales, and identified the sensitive tooth. Color change was analyzed by ANOVA and Tukey’s tests (α = 0.05). The absolute risk of TS and TS intensity evaluated by Fisher’s exact test and Kruskall Wallis test, respectively (α = 0.05). All groups achieved the same level of whitening at both evaluation periods, except for the 20% HP group, which showed the lowest amount of whitening as detected by the subjective evaluation. The use of light did not increase absolute risk of TS and TS intensity during and after bleaching for both scales. The premolars were the least sensitive. It can be concluded that the use of LED/laser light activation was able to increase the amount of whitening produced with the 20% HP without increasing TS, but this association was not useful for the 35% HP gel.
publishDate 2013
dc.date.available.fl_str_mv 2013-11-06
2017-07-24T19:22:29Z
dc.date.issued.fl_str_mv 2013-07-19
dc.date.accessioned.fl_str_mv 2017-07-24T19:22:29Z
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
dc.type.driver.fl_str_mv info:eu-repo/semantics/doctoralThesis
format doctoralThesis
status_str publishedVersion
dc.identifier.citation.fl_str_mv SERRANO, Alexandra Patricia Mena. Clinical efficacy of in-office bleaching using two concentrations of hydrogen peroxide with or without activation. 2013. 69 f. Tese (Doutorado em Clinica Integrada, Dentística Restauradora e Periodontia) - UNIVERSIDADE ESTADUAL DE PONTA GROSSA, Ponta Grossa, 2013.
dc.identifier.uri.fl_str_mv http://tede2.uepg.br/jspui/handle/prefix/1822
identifier_str_mv SERRANO, Alexandra Patricia Mena. Clinical efficacy of in-office bleaching using two concentrations of hydrogen peroxide with or without activation. 2013. 69 f. Tese (Doutorado em Clinica Integrada, Dentística Restauradora e Periodontia) - UNIVERSIDADE ESTADUAL DE PONTA GROSSA, Ponta Grossa, 2013.
url http://tede2.uepg.br/jspui/handle/prefix/1822
dc.language.iso.fl_str_mv por
language por
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv application/pdf
dc.publisher.none.fl_str_mv UNIVERSIDADE ESTADUAL DE PONTA GROSSA
dc.publisher.program.fl_str_mv Programa de Pós-Graduação em Odontologia
dc.publisher.initials.fl_str_mv UEPG
dc.publisher.country.fl_str_mv BR
dc.publisher.department.fl_str_mv Clinica Integrada, Dentística Restauradora e Periodontia
publisher.none.fl_str_mv UNIVERSIDADE ESTADUAL DE PONTA GROSSA
dc.source.none.fl_str_mv reponame:Biblioteca Digital de Teses e Dissertações da UEPG
instname:Universidade Estadual de Ponta Grossa (UEPG)
instacron:UEPG
instname_str Universidade Estadual de Ponta Grossa (UEPG)
instacron_str UEPG
institution UEPG
reponame_str Biblioteca Digital de Teses e Dissertações da UEPG
collection Biblioteca Digital de Teses e Dissertações da UEPG
bitstream.url.fl_str_mv http://tede2.uepg.br/jspui/bitstream/prefix/1822/1/Alexandra%20Mena%20Serrano.pdf
bitstream.checksum.fl_str_mv 4f3b7ca99bc8d5ac4bea8b11a5288ce7
bitstream.checksumAlgorithm.fl_str_mv MD5
repository.name.fl_str_mv Biblioteca Digital de Teses e Dissertações da UEPG - Universidade Estadual de Ponta Grossa (UEPG)
repository.mail.fl_str_mv bicen@uepg.br||mv_fidelis@yahoo.com.br
_version_ 1809460456135327744