AVALIAÇÃO DA INFLUÊNCIA DA CICLAGEM TÉRMICA E MECÂNICA NA EFETIVIDADE DA INTERFACE ADESIVA

Detalhes bibliográficos
Autor(a) principal: Sánchez-ayala, Alfonso
Data de Publicação: 2008
Tipo de documento: Dissertação
Idioma: por
Título da fonte: Biblioteca Digital de Teses e Dissertações da UEPG
Texto Completo: http://tede2.uepg.br/jspui/handle/prefix/1695
Resumo: The aim of this study was to evaluate in vitro the adhesive effectiveness in class V cavities using four different adhesive systems, being submit to thermocycling and occlusal load cycling. The cavities had a dimension of 3x2x1.8 mm3 and were made on amelo-cement junction on buccal and lingual of 80 human premolars (n=160). The used adhesive systems were Adper Single Bond 2, AdheSE, Adper Prompt LPop and One Coat 7.0. The used composite was Synergy® D6. The adhesive and photopolymerization (600 mW/cm2) proceedings were made conventionally and following the manufacturer recommendations. The specimens were divided in 4 groups (n=40) according to adhesive system used. Each group was divided in 4 subgroups (n=10) according to applycated stress (thermocycling, occlusal load cycling and thermocycling+occlusal load cycling). Each subgroup included 1 control group without stressing. The thermocycling was made using 500 cycles, with 5-55 C, dwell time of 15 seg and transfer time of 5 seg. The occlusal load cycling was made applying a force of 40-70 N during 50000 cycles with 2 Hz of frequency. Later, the specimens were impermeabilited and immersed in tracer agent of 50 % silver nitrate solution by 2 hours. Finally, the specimens were prepared for adhesive effectiveness evaluation through optic microscopy 40X (marginal microleakage occurrence) and scanning electronic microscopy 1000X (gaps formation). The tracer agent microleakage was measured qualitative (score) and quantitatively . The gap width was measured on 3 points of center of axial wall. The Kruskal-Wallis and post-hoc de Dunn, and ANOVA two-way and post-hoc Bonferroni tests were used on statistic analysis. Despite of few differences found in used adhesive system performance, the tendency could be observed to the increase of the marginal microleakage in the submitted groups specifically to thermocycling. On the other hand, the axial gaps formation presented progressively higher width in the submitted groups to thermocycling, occlusal load cycling and thermocycling+occlusal load cycling. It was concluded that the used adhesive system presented similar adhesive effectiveness when were submitted to thermal and mechanical stress.
id UEPG_da3a5957804e2e920667304a5f08b157
oai_identifier_str oai:tede2.uepg.br:prefix/1695
network_acronym_str UEPG
network_name_str Biblioteca Digital de Teses e Dissertações da UEPG
repository_id_str
spelling Gomes, Osnara Maria MongruelCPF:47308257991http://buscatextual.cnpq.br/buscatextual/visualizacv.do?id=K4773647J1Gomes, João CarlosCPF:33867771987http://buscatextual.cnpq.br/buscatextual/visualizacv.do?id=K4793213H4Mazur, Rui FernandoCPF:80218601972http://buscatextual.cnpq.br/buscatextual/opcoesVisualizacao.jsp?id=K4704715A1&nome=Rui_Fernando_Mazur&opcao=0CPF:01108673945http://buscatextual.cnpq.br/buscatextual/visualizacv.do?id=K4533582T7Sánchez-ayala, Alfonso2017-07-24T19:21:56Z2008-02-282017-07-24T19:21:56Z2008-01-31SÁNCHEZ-AYALA, Alfonso. AVALIAÇÃO DA INFLUÊNCIA DA CICLAGEM TÉRMICA E MECÂNICA NA EFETIVIDADE DA INTERFACE ADESIVA. 2008. 112 f. Dissertação (Mestrado em Clinica Integrada, Dentística Restauradora e Periodontia) - UNIVERSIDADE ESTADUAL DE PONTA GROSSA, Ponta Grossa, 2008.http://tede2.uepg.br/jspui/handle/prefix/1695The aim of this study was to evaluate in vitro the adhesive effectiveness in class V cavities using four different adhesive systems, being submit to thermocycling and occlusal load cycling. The cavities had a dimension of 3x2x1.8 mm3 and were made on amelo-cement junction on buccal and lingual of 80 human premolars (n=160). The used adhesive systems were Adper Single Bond 2, AdheSE, Adper Prompt LPop and One Coat 7.0. The used composite was Synergy® D6. The adhesive and photopolymerization (600 mW/cm2) proceedings were made conventionally and following the manufacturer recommendations. The specimens were divided in 4 groups (n=40) according to adhesive system used. Each group was divided in 4 subgroups (n=10) according to applycated stress (thermocycling, occlusal load cycling and thermocycling+occlusal load cycling). Each subgroup included 1 control group without stressing. The thermocycling was made using 500 cycles, with 5-55 C, dwell time of 15 seg and transfer time of 5 seg. The occlusal load cycling was made applying a force of 40-70 N during 50000 cycles with 2 Hz of frequency. Later, the specimens were impermeabilited and immersed in tracer agent of 50 % silver nitrate solution by 2 hours. Finally, the specimens were prepared for adhesive effectiveness evaluation through optic microscopy 40X (marginal microleakage occurrence) and scanning electronic microscopy 1000X (gaps formation). The tracer agent microleakage was measured qualitative (score) and quantitatively . The gap width was measured on 3 points of center of axial wall. The Kruskal-Wallis and post-hoc de Dunn, and ANOVA two-way and post-hoc Bonferroni tests were used on statistic analysis. Despite of few differences found in used adhesive system performance, the tendency could be observed to the increase of the marginal microleakage in the submitted groups specifically to thermocycling. On the other hand, the axial gaps formation presented progressively higher width in the submitted groups to thermocycling, occlusal load cycling and thermocycling+occlusal load cycling. It was concluded that the used adhesive system presented similar adhesive effectiveness when were submitted to thermal and mechanical stress.A proposição deste estudo foi avaliar in vitro a efetividade adesiva em cavidades de classe V utilizando quatro diferentes sistemas adesivos, sendo submetidas a termociclagem e carga cíclica oclusal. As cavidades tiveram uma dimensão de 3x2x1.8 mm3 e foram realizadas na união amelo-cementária em vestibular e lingual de 80 pré-molares humanos (n=160). Os sistemas adesivos empregados foram Adper Single Bond 2, AdheSE, Adper Prompt L-Pop e One Coat 7.0. A resina composta utilizada foi Synergy D6. Os procedimentos de adesão e fotopolomerização (600 mW/cm2) foram realizados convencionalmente e seguindo as recomendações do fabricante. Os espécimes foram divididos em 4 grupos (n=40) segundo o tipo sistema adesivo utilizado. Cada grupo foi dividido em 4 subgrupos (n=10) segundo o tipo de estresse aplicado (termociclagem, carga cíclica oclusal e termociclagem+carga cíclica oclusal). Cada subgrupo incluiu 1 grupo controle sem estresse. A termociclagem foi realizada utilizando 500 ciclos a 5-55 C, 15 seg de tempo de permanência em cada temperatura e 5 seg de tempo de transferência. A carga cíclica oclusal foi realizada aplicando uma força de 40-70 N durante 50000 ciclos com freqüência de 2 Hz. Posteriormente, os espécimes foram impermeabilizados e imersos em agente traçador de solução a 50 de nitrato de prata por 2 horas. Finalmente, os espécimes foram preparados para a avaliação da efetividade adesiva por meio de microscopia óptica 40X (ocorrência de microinfiltração marginal) e microscopia eletrônica de varredura 1000x (formação de fendas). A microinfiltração do agente traçador foi mensurada qualitativa (escore) e quantitativamente . A largura das fendas foi medida (μm) em 3 pontos do centro da parede axial. Os testes de Kruskal-Wallis e post-hoc de Dunn, e ANOVA two-way e post-hoc Bonferroni foram utilizados na análise estatística. Apesar das poucas diferenças significativas encontradas no desempenho dos sistemas adesivos utilizados, pôde-se observar a tendência ao aumento da microinfiltração marginal nos grupos submetidos especificamente a termociclagem. Por outro lado, a formação de fendas axiais apresentaram progressivamente maior largura nos grupos submetidos a termociclagem, carga cíclica e termociclagem+carga cíclica. Concluise que os sistemas adesivos avaliados apresentaram efetividade adesiva similar quando foram submetidos a estresse térmico e mecânico.Made available in DSpace on 2017-07-24T19:21:56Z (GMT). No. of bitstreams: 1 Alfonso Sanchez-Ayala.pdf: 4109673 bytes, checksum: f08284c2e1c48354c9d9e417e1b9484e (MD5) Previous issue date: 2008-01-31application/pdfporUNIVERSIDADE ESTADUAL DE PONTA GROSSAPrograma de Pós-Graduação em OdontologiaUEPGBRClinica Integrada, Dentística Restauradora e Periodontiainfiltração DentáriaAdesivos DentináriosNitrato de Pratadental leakagedentin-bonding agentssilver nitrateCNPQ::CIENCIAS DA SAUDE::ODONTOLOGIAAVALIAÇÃO DA INFLUÊNCIA DA CICLAGEM TÉRMICA E MECÂNICA NA EFETIVIDADE DA INTERFACE ADESIVAinfo:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/masterThesisinfo:eu-repo/semantics/openAccessreponame:Biblioteca Digital de Teses e Dissertações da UEPGinstname:Universidade Estadual de Ponta Grossa (UEPG)instacron:UEPGORIGINALAlfonso Sanchez-Ayala.pdfapplication/pdf4109673http://tede2.uepg.br/jspui/bitstream/prefix/1695/1/Alfonso%20Sanchez-Ayala.pdff08284c2e1c48354c9d9e417e1b9484eMD51prefix/16952017-07-24 16:21:56.898oai:tede2.uepg.br:prefix/1695Biblioteca Digital de Teses e Dissertaçõeshttps://tede2.uepg.br/jspui/PUBhttp://tede2.uepg.br/oai/requestbicen@uepg.br||mv_fidelis@yahoo.com.bropendoar:2017-07-24T19:21:56Biblioteca Digital de Teses e Dissertações da UEPG - Universidade Estadual de Ponta Grossa (UEPG)false
dc.title.por.fl_str_mv AVALIAÇÃO DA INFLUÊNCIA DA CICLAGEM TÉRMICA E MECÂNICA NA EFETIVIDADE DA INTERFACE ADESIVA
title AVALIAÇÃO DA INFLUÊNCIA DA CICLAGEM TÉRMICA E MECÂNICA NA EFETIVIDADE DA INTERFACE ADESIVA
spellingShingle AVALIAÇÃO DA INFLUÊNCIA DA CICLAGEM TÉRMICA E MECÂNICA NA EFETIVIDADE DA INTERFACE ADESIVA
Sánchez-ayala, Alfonso
infiltração Dentária
Adesivos Dentinários
Nitrato de Prata
dental leakage
dentin-bonding agents
silver nitrate
CNPQ::CIENCIAS DA SAUDE::ODONTOLOGIA
title_short AVALIAÇÃO DA INFLUÊNCIA DA CICLAGEM TÉRMICA E MECÂNICA NA EFETIVIDADE DA INTERFACE ADESIVA
title_full AVALIAÇÃO DA INFLUÊNCIA DA CICLAGEM TÉRMICA E MECÂNICA NA EFETIVIDADE DA INTERFACE ADESIVA
title_fullStr AVALIAÇÃO DA INFLUÊNCIA DA CICLAGEM TÉRMICA E MECÂNICA NA EFETIVIDADE DA INTERFACE ADESIVA
title_full_unstemmed AVALIAÇÃO DA INFLUÊNCIA DA CICLAGEM TÉRMICA E MECÂNICA NA EFETIVIDADE DA INTERFACE ADESIVA
title_sort AVALIAÇÃO DA INFLUÊNCIA DA CICLAGEM TÉRMICA E MECÂNICA NA EFETIVIDADE DA INTERFACE ADESIVA
author Sánchez-ayala, Alfonso
author_facet Sánchez-ayala, Alfonso
author_role author
dc.contributor.advisor1.fl_str_mv Gomes, Osnara Maria Mongruel
dc.contributor.advisor1ID.fl_str_mv CPF:47308257991
dc.contributor.advisor1Lattes.fl_str_mv http://buscatextual.cnpq.br/buscatextual/visualizacv.do?id=K4773647J1
dc.contributor.referee1.fl_str_mv Gomes, João Carlos
dc.contributor.referee1ID.fl_str_mv CPF:33867771987
dc.contributor.referee1Lattes.fl_str_mv http://buscatextual.cnpq.br/buscatextual/visualizacv.do?id=K4793213H4
dc.contributor.referee2.fl_str_mv Mazur, Rui Fernando
dc.contributor.referee2ID.fl_str_mv CPF:80218601972
dc.contributor.referee2Lattes.fl_str_mv http://buscatextual.cnpq.br/buscatextual/opcoesVisualizacao.jsp?id=K4704715A1&nome=Rui_Fernando_Mazur&opcao=0
dc.contributor.authorID.fl_str_mv CPF:01108673945
dc.contributor.authorLattes.fl_str_mv http://buscatextual.cnpq.br/buscatextual/visualizacv.do?id=K4533582T7
dc.contributor.author.fl_str_mv Sánchez-ayala, Alfonso
contributor_str_mv Gomes, Osnara Maria Mongruel
Gomes, João Carlos
Mazur, Rui Fernando
dc.subject.por.fl_str_mv infiltração Dentária
Adesivos Dentinários
Nitrato de Prata
topic infiltração Dentária
Adesivos Dentinários
Nitrato de Prata
dental leakage
dentin-bonding agents
silver nitrate
CNPQ::CIENCIAS DA SAUDE::ODONTOLOGIA
dc.subject.eng.fl_str_mv dental leakage
dentin-bonding agents
silver nitrate
dc.subject.cnpq.fl_str_mv CNPQ::CIENCIAS DA SAUDE::ODONTOLOGIA
description The aim of this study was to evaluate in vitro the adhesive effectiveness in class V cavities using four different adhesive systems, being submit to thermocycling and occlusal load cycling. The cavities had a dimension of 3x2x1.8 mm3 and were made on amelo-cement junction on buccal and lingual of 80 human premolars (n=160). The used adhesive systems were Adper Single Bond 2, AdheSE, Adper Prompt LPop and One Coat 7.0. The used composite was Synergy® D6. The adhesive and photopolymerization (600 mW/cm2) proceedings were made conventionally and following the manufacturer recommendations. The specimens were divided in 4 groups (n=40) according to adhesive system used. Each group was divided in 4 subgroups (n=10) according to applycated stress (thermocycling, occlusal load cycling and thermocycling+occlusal load cycling). Each subgroup included 1 control group without stressing. The thermocycling was made using 500 cycles, with 5-55 C, dwell time of 15 seg and transfer time of 5 seg. The occlusal load cycling was made applying a force of 40-70 N during 50000 cycles with 2 Hz of frequency. Later, the specimens were impermeabilited and immersed in tracer agent of 50 % silver nitrate solution by 2 hours. Finally, the specimens were prepared for adhesive effectiveness evaluation through optic microscopy 40X (marginal microleakage occurrence) and scanning electronic microscopy 1000X (gaps formation). The tracer agent microleakage was measured qualitative (score) and quantitatively . The gap width was measured on 3 points of center of axial wall. The Kruskal-Wallis and post-hoc de Dunn, and ANOVA two-way and post-hoc Bonferroni tests were used on statistic analysis. Despite of few differences found in used adhesive system performance, the tendency could be observed to the increase of the marginal microleakage in the submitted groups specifically to thermocycling. On the other hand, the axial gaps formation presented progressively higher width in the submitted groups to thermocycling, occlusal load cycling and thermocycling+occlusal load cycling. It was concluded that the used adhesive system presented similar adhesive effectiveness when were submitted to thermal and mechanical stress.
publishDate 2008
dc.date.available.fl_str_mv 2008-02-28
2017-07-24T19:21:56Z
dc.date.issued.fl_str_mv 2008-01-31
dc.date.accessioned.fl_str_mv 2017-07-24T19:21:56Z
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
dc.type.driver.fl_str_mv info:eu-repo/semantics/masterThesis
format masterThesis
status_str publishedVersion
dc.identifier.citation.fl_str_mv SÁNCHEZ-AYALA, Alfonso. AVALIAÇÃO DA INFLUÊNCIA DA CICLAGEM TÉRMICA E MECÂNICA NA EFETIVIDADE DA INTERFACE ADESIVA. 2008. 112 f. Dissertação (Mestrado em Clinica Integrada, Dentística Restauradora e Periodontia) - UNIVERSIDADE ESTADUAL DE PONTA GROSSA, Ponta Grossa, 2008.
dc.identifier.uri.fl_str_mv http://tede2.uepg.br/jspui/handle/prefix/1695
identifier_str_mv SÁNCHEZ-AYALA, Alfonso. AVALIAÇÃO DA INFLUÊNCIA DA CICLAGEM TÉRMICA E MECÂNICA NA EFETIVIDADE DA INTERFACE ADESIVA. 2008. 112 f. Dissertação (Mestrado em Clinica Integrada, Dentística Restauradora e Periodontia) - UNIVERSIDADE ESTADUAL DE PONTA GROSSA, Ponta Grossa, 2008.
url http://tede2.uepg.br/jspui/handle/prefix/1695
dc.language.iso.fl_str_mv por
language por
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv application/pdf
dc.publisher.none.fl_str_mv UNIVERSIDADE ESTADUAL DE PONTA GROSSA
dc.publisher.program.fl_str_mv Programa de Pós-Graduação em Odontologia
dc.publisher.initials.fl_str_mv UEPG
dc.publisher.country.fl_str_mv BR
dc.publisher.department.fl_str_mv Clinica Integrada, Dentística Restauradora e Periodontia
publisher.none.fl_str_mv UNIVERSIDADE ESTADUAL DE PONTA GROSSA
dc.source.none.fl_str_mv reponame:Biblioteca Digital de Teses e Dissertações da UEPG
instname:Universidade Estadual de Ponta Grossa (UEPG)
instacron:UEPG
instname_str Universidade Estadual de Ponta Grossa (UEPG)
instacron_str UEPG
institution UEPG
reponame_str Biblioteca Digital de Teses e Dissertações da UEPG
collection Biblioteca Digital de Teses e Dissertações da UEPG
bitstream.url.fl_str_mv http://tede2.uepg.br/jspui/bitstream/prefix/1695/1/Alfonso%20Sanchez-Ayala.pdf
bitstream.checksum.fl_str_mv f08284c2e1c48354c9d9e417e1b9484e
bitstream.checksumAlgorithm.fl_str_mv MD5
repository.name.fl_str_mv Biblioteca Digital de Teses e Dissertações da UEPG - Universidade Estadual de Ponta Grossa (UEPG)
repository.mail.fl_str_mv bicen@uepg.br||mv_fidelis@yahoo.com.br
_version_ 1800232802129543168