Comparison of Fit Accuracy between Procera® Custom Abutments and Three Implant Systems

Detalhes bibliográficos
Autor(a) principal: Cunha, Tiago de Morais Alves da
Data de Publicação: 2012
Outros Autores: Araújo, Roberto Paulo Correia de, Rocha, Paulo Vicente Barbosa da, Amoedo, Rosa Maria Pazos
Tipo de documento: Artigo
Idioma: eng
Título da fonte: Repositório Institucional da UFBA
Texto Completo: http://repositorio.ufba.br/ri/handle/ri/14895
Resumo: Texto completo: acesso restrito. p. 890–895
id UFBA-2_3a702b5baec002c5d1f375dd0e8ac2e8
oai_identifier_str oai:repositorio.ufba.br:ri/14895
network_acronym_str UFBA-2
network_name_str Repositório Institucional da UFBA
repository_id_str 1932
spelling Cunha, Tiago de Morais Alves daAraújo, Roberto Paulo Correia deRocha, Paulo Vicente Barbosa daAmoedo, Rosa Maria PazosCunha, Tiago de Morais Alves daAraújo, Roberto Paulo Correia deRocha, Paulo Vicente Barbosa daAmoedo, Rosa Maria Pazos2014-05-01T13:10:18Z20121523-0899http://repositorio.ufba.br/ri/handle/ri/14895v. 14, n. 6Texto completo: acesso restrito. p. 890–895Background: Although increase of misfit has been reported when associating implant and abutment from different manufacturers, Procera custom abutment has been universally used in clinical practice. Purpose: The purpose of this investigation was to compare the vertical gap of zirconia Procera® abutment associated with implants from the same manufacturer (Procera manufacturer) and two other implant systems. Materials and Methods: Twenty-four zirconia Procera abutments were produced using computer-assisted design and manufacture and paired with (a) eight MK III, RP 4.1 × 10 mm implants (Nobel Biocare™, Göteborg, Sweden) – GNB group (Nobel Biocare group); (b) eight Try on, 4.1 × 10 mm implants (Sistema de Implantes, São Paulo, Brazil) – ES group (SIN experimental group) ; and (c) eight Master screw, 4.1 × 10 mm implants (Conexão® Sistema de Prótese, São Paulo, Brazil) – EC group (Conexão experimental group). A comparison of the vertical misfit at the implant–abutment interface was taken at six measuring sites on each sample using scanning electron microscopy with a magnification of 408×. One-way analysis of variance was used to test for differences, and Tukey's test was used for pair-wise comparison of groups (α = 0.05). Results: Significant differences relative to average misfit were found when Procera abutments were associated with other implant manufacturers. The ES group and EC group did not differ significantly, but both demonstrated significantly larger average misfit than the GNB group (p = .001). The average misfit was 5.7 µm ± 0.39, 9.53 µm ± 0.52, and 10.62 µm ± 2.16, respectively, for groups GNB, ES, and EC. Conclusion: The association of Procera zirconia abutment with other implant systems different from its manufacturer demonstrated significant alteration of vertical misfit at implant–abutment interface.Submitted by Edileide Reis (leyde-landy@hotmail.com) on 2014-04-24T11:42:18Z No. of bitstreams: 1 Tiago de Morais Alves da Cunha.pdf: 338125 bytes, checksum: 8efd85ec65bcf9ae4a7f68f5953d8094 (MD5)Approved for entry into archive by Patricia Barroso (pbarroso@ufba.br) on 2014-05-01T13:10:18Z (GMT) No. of bitstreams: 1 Tiago de Morais Alves da Cunha.pdf: 338125 bytes, checksum: 8efd85ec65bcf9ae4a7f68f5953d8094 (MD5)Made available in DSpace on 2014-05-01T13:10:18Z (GMT). No. of bitstreams: 1 Tiago de Morais Alves da Cunha.pdf: 338125 bytes, checksum: 8efd85ec65bcf9ae4a7f68f5953d8094 (MD5) Previous issue date: 2012http://dx.doi.org/ 10.1111/j.1708-8208.2010.00323.xreponame:Repositório Institucional da UFBAinstname:Universidade Federal da Bahia (UFBA)instacron:UFBADental implantsImplant-supported prosthesis;MisfitProsthodontic planningComparison of Fit Accuracy between Procera® Custom Abutments and Three Implant SystemsClinical Implant Dentistry and Related Researchinfo:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/article10000-01-01info:eu-repo/semantics/openAccessengORIGINALTiago de Morais Alves da Cunha.pdfTiago de Morais Alves da Cunha.pdfapplication/pdf338125https://repositorio.ufba.br/bitstream/ri/14895/1/Tiago%20de%20Morais%20Alves%20da%20Cunha.pdf8efd85ec65bcf9ae4a7f68f5953d8094MD51LICENSElicense.txtlicense.txttext/plain1345https://repositorio.ufba.br/bitstream/ri/14895/2/license.txt0d4b811ef71182510d2015daa7c8a900MD52TEXTTiago de Morais Alves da Cunha.pdf.txtTiago de Morais Alves da Cunha.pdf.txtExtracted texttext/plain22806https://repositorio.ufba.br/bitstream/ri/14895/3/Tiago%20de%20Morais%20Alves%20da%20Cunha.pdf.txt96202330d7edc4cfde8be9685045cae7MD53ri/148952022-08-08 13:17:50.177oai:repositorio.ufba.br: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Repositório InstitucionalPUBhttp://192.188.11.11:8080/oai/requestopendoar:19322022-08-08T16:17:50Repositório Institucional da UFBA - Universidade Federal da Bahia (UFBA)false
dc.title.pt_BR.fl_str_mv Comparison of Fit Accuracy between Procera® Custom Abutments and Three Implant Systems
dc.title.alternative.pt_BR.fl_str_mv Clinical Implant Dentistry and Related Research
title Comparison of Fit Accuracy between Procera® Custom Abutments and Three Implant Systems
spellingShingle Comparison of Fit Accuracy between Procera® Custom Abutments and Three Implant Systems
Cunha, Tiago de Morais Alves da
Dental implants
Implant-supported prosthesis;
Misfit
Prosthodontic planning
title_short Comparison of Fit Accuracy between Procera® Custom Abutments and Three Implant Systems
title_full Comparison of Fit Accuracy between Procera® Custom Abutments and Three Implant Systems
title_fullStr Comparison of Fit Accuracy between Procera® Custom Abutments and Three Implant Systems
title_full_unstemmed Comparison of Fit Accuracy between Procera® Custom Abutments and Three Implant Systems
title_sort Comparison of Fit Accuracy between Procera® Custom Abutments and Three Implant Systems
author Cunha, Tiago de Morais Alves da
author_facet Cunha, Tiago de Morais Alves da
Araújo, Roberto Paulo Correia de
Rocha, Paulo Vicente Barbosa da
Amoedo, Rosa Maria Pazos
author_role author
author2 Araújo, Roberto Paulo Correia de
Rocha, Paulo Vicente Barbosa da
Amoedo, Rosa Maria Pazos
author2_role author
author
author
dc.contributor.author.fl_str_mv Cunha, Tiago de Morais Alves da
Araújo, Roberto Paulo Correia de
Rocha, Paulo Vicente Barbosa da
Amoedo, Rosa Maria Pazos
Cunha, Tiago de Morais Alves da
Araújo, Roberto Paulo Correia de
Rocha, Paulo Vicente Barbosa da
Amoedo, Rosa Maria Pazos
dc.subject.por.fl_str_mv Dental implants
Implant-supported prosthesis;
Misfit
Prosthodontic planning
topic Dental implants
Implant-supported prosthesis;
Misfit
Prosthodontic planning
description Texto completo: acesso restrito. p. 890–895
publishDate 2012
dc.date.issued.fl_str_mv 2012
dc.date.accessioned.fl_str_mv 2014-05-01T13:10:18Z
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
dc.type.driver.fl_str_mv info:eu-repo/semantics/article
format article
status_str publishedVersion
dc.identifier.uri.fl_str_mv http://repositorio.ufba.br/ri/handle/ri/14895
dc.identifier.issn.none.fl_str_mv 1523-0899
dc.identifier.number.pt_BR.fl_str_mv v. 14, n. 6
identifier_str_mv 1523-0899
v. 14, n. 6
url http://repositorio.ufba.br/ri/handle/ri/14895
dc.language.iso.fl_str_mv eng
language eng
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.source.pt_BR.fl_str_mv http://dx.doi.org/ 10.1111/j.1708-8208.2010.00323.x
dc.source.none.fl_str_mv reponame:Repositório Institucional da UFBA
instname:Universidade Federal da Bahia (UFBA)
instacron:UFBA
instname_str Universidade Federal da Bahia (UFBA)
instacron_str UFBA
institution UFBA
reponame_str Repositório Institucional da UFBA
collection Repositório Institucional da UFBA
bitstream.url.fl_str_mv https://repositorio.ufba.br/bitstream/ri/14895/1/Tiago%20de%20Morais%20Alves%20da%20Cunha.pdf
https://repositorio.ufba.br/bitstream/ri/14895/2/license.txt
https://repositorio.ufba.br/bitstream/ri/14895/3/Tiago%20de%20Morais%20Alves%20da%20Cunha.pdf.txt
bitstream.checksum.fl_str_mv 8efd85ec65bcf9ae4a7f68f5953d8094
0d4b811ef71182510d2015daa7c8a900
96202330d7edc4cfde8be9685045cae7
bitstream.checksumAlgorithm.fl_str_mv MD5
MD5
MD5
repository.name.fl_str_mv Repositório Institucional da UFBA - Universidade Federal da Bahia (UFBA)
repository.mail.fl_str_mv
_version_ 1808459476163887104