Análise de Coastdown utilizando dados nominais de bombas de refrigeração de reatores PWR

Detalhes bibliográficos
Autor(a) principal: Silva, Caroline Rodrigues da
Data de Publicação: 2016
Tipo de documento: Dissertação
Idioma: por
Título da fonte: Repositório Institucional da UFABC
Texto Completo: http://biblioteca.ufabc.edu.br/index.php?codigo_sophia=105826
Resumo: Orientador: Prof. Dr. Pedro Carajilescov
id UFBC_c4fe119285b40177cd267444ea197740
oai_identifier_str oai:BDTD:105826
network_acronym_str UFBC
network_name_str Repositório Institucional da UFABC
repository_id_str
spelling Análise de Coastdown utilizando dados nominais de bombas de refrigeração de reatores PWRACIDENTE DE FALHA DE BOMBASANÁLISE DE CIRCUITO HIDRÁULICO DE REATOR NUCLEARESCOASTDOWNPUMPS FAILURE ACCIDENTHYDRAULIC CIRCUIT ANALYSIS OF NUCLEAR POWER PLANTSPROGRAMA DE PÓS-GRADUAÇÃO EM ENERGIA - UFABCOrientador: Prof. Dr. Pedro CarajilescovDissertação (mestrado) - Universidade Federal do ABC. Programa de Pós-Graduação em Energia, 2016.Os estudos sobre transitórios em bombas de refrigeração de um reator são importantes para a análise de segurança de uma central nuclear. Uma análise precisa do decaimento da vazão de refrigerante no circuito primário durante uma eventual falha das bombas principais de refrigeração, evento conhecido como coastdown, é requerida tanto para pelos critérios de segurança estabelecidos como para a especificação e fabricação das bombas. Neste trabalho, o estudo é realizado utilizando um modelo matemático para simular transiente de vazão durante o período de coastdown em reatores nuclear do tipo PWR, no qual a equação de conservação da quantidade de movimento linear é utilizada de uma forma adimensional. Informações detalhadas sobre as características da bomba centrífuga não são necessárias. Como resultado, o decaimento da vazão é determinado a partir da razão entre dois parâmetros: a energia cinética do fluido refrigerante no circuito e a energia cinética armazenada nas partes rotativas da bomba. Em estudos anteriores, essa razão, denominada razão de energia efetiva, é mantida constante durante todo o evento de coastdown. Neste trabalho, foram propostas três correções para a melhoria dos resultados, a saber: a consideração de uma razão de energia efetiva variável durante o transitório, das variações na eficiência da bomba durante o transitório e das perdas mecânicas internas devido ao atrito e viscosidade no interior da bomba para baixas rotações. Para implementação do modelo proposto foi desenvolvido um programa, denominado de COREP-flow, cujos resultados foram comparados com dados experimentais obtidos na literatura. As comparações mostraram uma melhoria na reprodução desses resultados em relação aos modelos de referência. No Modelo 5 desenvolvido neste trabalho, os resultados obtidos apresentaram menor discrepância quando comparados com os dados experimentais. Para vazões superiores a 20 % da vazão inicial, a vazão de refrigerante calculada pelo Modelo 5 apresentou uma discrepância relativa média de 1,8 %, enquanto que o modelo proposto por Gao et al. (2011) apresentou uma discrepância relativa média de 4 %. Para vazões de refrigerantes inferiores a 20 % da vazão inicial, a discrepância relativa média para a vazão de refrigerante do Modelo 5 foi de 10,3 %, enquanto que a de Gao et al. (2011) foi de 50,6 %.The transient studies in reactor cooling pumps (RCPs) are important for the nuclear power plant security analysis. An accurate analysis of flow coastdown in the primary cooling loop system during an eventual failure of the RCPs is required both for the established security criteria, and for the pumps specification and manufacturing. In this work, the study is performed using a mathematical model to simulate the flow rate transient in PWR reactor type during flow coastdown period, in which the conservation of linear momentum equation is non-dimensional. The detailed information of the centrifugal pump characteristics are not required. As result, the coastdown is determined from the ratio between two parameters: the kinetic energy of the coolant in the circuit and the kinetic energy stored in the rotating parts of the pump. In previous studies, the ratio, known as energy ratio, is kept constant during the whole coastdown period. In this work, it was proposed three corrections aiming the improvement of the results, to know: the consideration of an energy ratio variable during the transient, of the efficiency variations of the pumps during the transient and of the internal mechanical losses due to friction and viscosity inside the pump for low rotations. For the model implementation, a program was developed, the COREP-flow, whose results were compared to the experimental data obtained in the literature. The comparison showed an improvement in the reproduction of the results in relation to the reference models. In Model 5, developed in this work, the obtained results presented less discrepancy when compared to the experimental data. For flow rates higher than 20% of the initial flow, the coolant flow calculated by Model 5 presented a mean relative discrepancy of 1.8%, while the model proposed by Gao et al. (2011) presented a mean relative discrepancy of 4%. For coolant flow rates less than 20% of the initial flow, the mean relative discrepancy for the coolant flow of Model 5 was of 10.3%, while the one from Gao et al. (2011) presented a mean relative discrepancy of 50.6%.Carajilescov, PedroMoreira, João Manoel LosadaRossi, PedroAndrade, Delvonei Alves deSilva, Caroline Rodrigues da2016info:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/masterThesisapplication/pdf90 f. : il.http://biblioteca.ufabc.edu.br/index.php?codigo_sophia=105826http://biblioteca.ufabc.edu.br/index.php?codigo_sophia=105826&midiaext=74164http://biblioteca.ufabc.edu.br/index.php?codigo_sophia=105826&midiaext=74165Cover: http://biblioteca.ufabc.edu.br/php/capa.php?obra=105826porreponame:Repositório Institucional da UFABCinstname:Universidade Federal do ABC (UFABC)instacron:UFABCinfo:eu-repo/semantics/openAccess2022-03-22T15:44:41Zoai:BDTD:105826Repositório InstitucionalPUBhttp://www.biblioteca.ufabc.edu.br/oai/oai.phpopendoar:2022-03-22T15:44:41Repositório Institucional da UFABC - Universidade Federal do ABC (UFABC)false
dc.title.none.fl_str_mv Análise de Coastdown utilizando dados nominais de bombas de refrigeração de reatores PWR
title Análise de Coastdown utilizando dados nominais de bombas de refrigeração de reatores PWR
spellingShingle Análise de Coastdown utilizando dados nominais de bombas de refrigeração de reatores PWR
Silva, Caroline Rodrigues da
ACIDENTE DE FALHA DE BOMBAS
ANÁLISE DE CIRCUITO HIDRÁULICO DE REATOR NUCLEARES
COASTDOWN
PUMPS FAILURE ACCIDENT
HYDRAULIC CIRCUIT ANALYSIS OF NUCLEAR POWER PLANTS
PROGRAMA DE PÓS-GRADUAÇÃO EM ENERGIA - UFABC
title_short Análise de Coastdown utilizando dados nominais de bombas de refrigeração de reatores PWR
title_full Análise de Coastdown utilizando dados nominais de bombas de refrigeração de reatores PWR
title_fullStr Análise de Coastdown utilizando dados nominais de bombas de refrigeração de reatores PWR
title_full_unstemmed Análise de Coastdown utilizando dados nominais de bombas de refrigeração de reatores PWR
title_sort Análise de Coastdown utilizando dados nominais de bombas de refrigeração de reatores PWR
author Silva, Caroline Rodrigues da
author_facet Silva, Caroline Rodrigues da
author_role author
dc.contributor.none.fl_str_mv Carajilescov, Pedro
Moreira, João Manoel Losada
Rossi, Pedro
Andrade, Delvonei Alves de
dc.contributor.author.fl_str_mv Silva, Caroline Rodrigues da
dc.subject.por.fl_str_mv ACIDENTE DE FALHA DE BOMBAS
ANÁLISE DE CIRCUITO HIDRÁULICO DE REATOR NUCLEARES
COASTDOWN
PUMPS FAILURE ACCIDENT
HYDRAULIC CIRCUIT ANALYSIS OF NUCLEAR POWER PLANTS
PROGRAMA DE PÓS-GRADUAÇÃO EM ENERGIA - UFABC
topic ACIDENTE DE FALHA DE BOMBAS
ANÁLISE DE CIRCUITO HIDRÁULICO DE REATOR NUCLEARES
COASTDOWN
PUMPS FAILURE ACCIDENT
HYDRAULIC CIRCUIT ANALYSIS OF NUCLEAR POWER PLANTS
PROGRAMA DE PÓS-GRADUAÇÃO EM ENERGIA - UFABC
description Orientador: Prof. Dr. Pedro Carajilescov
publishDate 2016
dc.date.none.fl_str_mv 2016
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
dc.type.driver.fl_str_mv info:eu-repo/semantics/masterThesis
format masterThesis
status_str publishedVersion
dc.identifier.uri.fl_str_mv http://biblioteca.ufabc.edu.br/index.php?codigo_sophia=105826
url http://biblioteca.ufabc.edu.br/index.php?codigo_sophia=105826
dc.language.iso.fl_str_mv por
language por
dc.relation.none.fl_str_mv http://biblioteca.ufabc.edu.br/index.php?codigo_sophia=105826&midiaext=74164
http://biblioteca.ufabc.edu.br/index.php?codigo_sophia=105826&midiaext=74165
Cover: http://biblioteca.ufabc.edu.br/php/capa.php?obra=105826
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv application/pdf
90 f. : il.
dc.source.none.fl_str_mv reponame:Repositório Institucional da UFABC
instname:Universidade Federal do ABC (UFABC)
instacron:UFABC
instname_str Universidade Federal do ABC (UFABC)
instacron_str UFABC
institution UFABC
reponame_str Repositório Institucional da UFABC
collection Repositório Institucional da UFABC
repository.name.fl_str_mv Repositório Institucional da UFABC - Universidade Federal do ABC (UFABC)
repository.mail.fl_str_mv
_version_ 1799772940451971072