Characterization and selection method of Venturi injectors for pressurized irrigation

Detalhes bibliográficos
Autor(a) principal: Manzano,Juan
Data de Publicação: 2018
Outros Autores: Palau,Carmen Virginia, Azevedo,Benito Moreira de, Bomfim,Guilherme Vieira do, Vasconcelos,Denise Vieira
Tipo de documento: Artigo
Idioma: eng
Título da fonte: Revista ciência agronômica (Online)
Texto Completo: http://old.scielo.br/scielo.php?script=sci_arttext&pid=S1806-66902018000200201
Resumo: ABSTRACT Venturi-type chemigation injectors are widely used due to their advantages: they do not require electric power and are cheap to operate. However, they also generate considerable energy losses which affect the pressure in the system. The correct characterization of these systems requires pressures to be correctly set at the inlet, injector and outlet points in relation to main and injected solution flows. These analytical relationships, as described in the International Organization for Standardization’s standard ISO 15873:2002, can be obtained theoretically, although it is recommended that the manufacturer should determine the real behavior of the injector by operational tests. These relationships should also be provided graphically in the form of nomograms in order to facilitate the association of the variables involved and the subsequent selection of a specific model or class and type of assembly. In order to make the right choice, it is also necessary to have precise information on the irrigation sub-units that it feeds and the grower’s fertilization program.
id UFC-2_a43a90a69abf9132df08260da0bdc735
oai_identifier_str oai:scielo:S1806-66902018000200201
network_acronym_str UFC-2
network_name_str Revista ciência agronômica (Online)
repository_id_str
spelling Characterization and selection method of Venturi injectors for pressurized irrigationChemigationFertigationHead lossesNomographyABSTRACT Venturi-type chemigation injectors are widely used due to their advantages: they do not require electric power and are cheap to operate. However, they also generate considerable energy losses which affect the pressure in the system. The correct characterization of these systems requires pressures to be correctly set at the inlet, injector and outlet points in relation to main and injected solution flows. These analytical relationships, as described in the International Organization for Standardization’s standard ISO 15873:2002, can be obtained theoretically, although it is recommended that the manufacturer should determine the real behavior of the injector by operational tests. These relationships should also be provided graphically in the form of nomograms in order to facilitate the association of the variables involved and the subsequent selection of a specific model or class and type of assembly. In order to make the right choice, it is also necessary to have precise information on the irrigation sub-units that it feeds and the grower’s fertilization program.Universidade Federal do Ceará2018-06-01info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersiontext/htmlhttp://old.scielo.br/scielo.php?script=sci_arttext&pid=S1806-66902018000200201Revista Ciência Agronômica v.49 n.2 2018reponame:Revista ciência agronômica (Online)instname:Universidade Federal do Ceará (UFC)instacron:UFC10.5935/1806-6690.20180023info:eu-repo/semantics/openAccessManzano,JuanPalau,Carmen VirginiaAzevedo,Benito Moreira deBomfim,Guilherme Vieira doVasconcelos,Denise Vieiraeng2018-04-05T00:00:00Zoai:scielo:S1806-66902018000200201Revistahttp://www.ccarevista.ufc.br/PUBhttps://old.scielo.br/oai/scielo-oai.php||alekdutra@ufc.br|| ccarev@ufc.br1806-66900045-6888opendoar:2018-04-05T00:00Revista ciência agronômica (Online) - Universidade Federal do Ceará (UFC)false
dc.title.none.fl_str_mv Characterization and selection method of Venturi injectors for pressurized irrigation
title Characterization and selection method of Venturi injectors for pressurized irrigation
spellingShingle Characterization and selection method of Venturi injectors for pressurized irrigation
Manzano,Juan
Chemigation
Fertigation
Head losses
Nomography
title_short Characterization and selection method of Venturi injectors for pressurized irrigation
title_full Characterization and selection method of Venturi injectors for pressurized irrigation
title_fullStr Characterization and selection method of Venturi injectors for pressurized irrigation
title_full_unstemmed Characterization and selection method of Venturi injectors for pressurized irrigation
title_sort Characterization and selection method of Venturi injectors for pressurized irrigation
author Manzano,Juan
author_facet Manzano,Juan
Palau,Carmen Virginia
Azevedo,Benito Moreira de
Bomfim,Guilherme Vieira do
Vasconcelos,Denise Vieira
author_role author
author2 Palau,Carmen Virginia
Azevedo,Benito Moreira de
Bomfim,Guilherme Vieira do
Vasconcelos,Denise Vieira
author2_role author
author
author
author
dc.contributor.author.fl_str_mv Manzano,Juan
Palau,Carmen Virginia
Azevedo,Benito Moreira de
Bomfim,Guilherme Vieira do
Vasconcelos,Denise Vieira
dc.subject.por.fl_str_mv Chemigation
Fertigation
Head losses
Nomography
topic Chemigation
Fertigation
Head losses
Nomography
description ABSTRACT Venturi-type chemigation injectors are widely used due to their advantages: they do not require electric power and are cheap to operate. However, they also generate considerable energy losses which affect the pressure in the system. The correct characterization of these systems requires pressures to be correctly set at the inlet, injector and outlet points in relation to main and injected solution flows. These analytical relationships, as described in the International Organization for Standardization’s standard ISO 15873:2002, can be obtained theoretically, although it is recommended that the manufacturer should determine the real behavior of the injector by operational tests. These relationships should also be provided graphically in the form of nomograms in order to facilitate the association of the variables involved and the subsequent selection of a specific model or class and type of assembly. In order to make the right choice, it is also necessary to have precise information on the irrigation sub-units that it feeds and the grower’s fertilization program.
publishDate 2018
dc.date.none.fl_str_mv 2018-06-01
dc.type.driver.fl_str_mv info:eu-repo/semantics/article
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
format article
status_str publishedVersion
dc.identifier.uri.fl_str_mv http://old.scielo.br/scielo.php?script=sci_arttext&pid=S1806-66902018000200201
url http://old.scielo.br/scielo.php?script=sci_arttext&pid=S1806-66902018000200201
dc.language.iso.fl_str_mv eng
language eng
dc.relation.none.fl_str_mv 10.5935/1806-6690.20180023
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv text/html
dc.publisher.none.fl_str_mv Universidade Federal do Ceará
publisher.none.fl_str_mv Universidade Federal do Ceará
dc.source.none.fl_str_mv Revista Ciência Agronômica v.49 n.2 2018
reponame:Revista ciência agronômica (Online)
instname:Universidade Federal do Ceará (UFC)
instacron:UFC
instname_str Universidade Federal do Ceará (UFC)
instacron_str UFC
institution UFC
reponame_str Revista ciência agronômica (Online)
collection Revista ciência agronômica (Online)
repository.name.fl_str_mv Revista ciência agronômica (Online) - Universidade Federal do Ceará (UFC)
repository.mail.fl_str_mv ||alekdutra@ufc.br|| ccarev@ufc.br
_version_ 1750297489002463232