Ineffective breathing pattern in cardiac postoperative patients : diagnostic accuracy study

Detalhes bibliográficos
Autor(a) principal: Sousa, Vanessa Emille Carvalho de
Data de Publicação: 2016
Outros Autores: Pascoal, Lívia Maia, Nascimento, Ranielly Vidal do, Matos, Talita Ferreira Oliveira de, Beltrão, Beatriz Amorim, Silva, Viviane Martins da, Lopes, Marcos Venícios de Oliveira
Tipo de documento: Artigo
Idioma: eng
Título da fonte: Repositório Institucional da Universidade Federal do Ceará (UFC)
Texto Completo: http://www.repositorio.ufc.br/handle/riufc/24246
Resumo: Purpose: The aim of this study was to analyze the accuracy of the de fi ning characteristics of ineffective breathing pattern (IBP) in postoperative cardiac patients. Methods: A diagnostic accuracy study was performed with 98 patients. Measures of sensitivity, speci fi city, predictive values, likelihood ratios, diagnostic odds ratio, and area under the ROC curve were calculated. Results: IBP was present in 23.5% of the patients. Alterations in depth of breathing (sensitivity 96%, negative likelihood ratio 0.11%) and pursed-lip breathing (sensitivity 99%, negative likelihood ratio 0.07%) were the most sensitive de fi ning characteristics for IBP, while altered chest excursion (speci fi city 97%, positive likelihood ratio 11.41%) and prolonged expiration phase (speci fi city 99%, positive likelihood ratio 42.39%) were the most speci fi c. Conclusion: Some clinical indicators were more related to the presence or absence of IBP than others. Knowledge of such measures can help nurses to assess patients more accurately.
id UFC-7_5fd66c1e44bdb5a3c5909047bfdb4ce0
oai_identifier_str oai:repositorio.ufc.br:riufc/24246
network_acronym_str UFC-7
network_name_str Repositório Institucional da Universidade Federal do Ceará (UFC)
repository_id_str
spelling Ineffective breathing pattern in cardiac postoperative patients : diagnostic accuracy studyDiagnóstico de EnfermagemCuidados Pós-OperatóriosPostoperative CarePurpose: The aim of this study was to analyze the accuracy of the de fi ning characteristics of ineffective breathing pattern (IBP) in postoperative cardiac patients. Methods: A diagnostic accuracy study was performed with 98 patients. Measures of sensitivity, speci fi city, predictive values, likelihood ratios, diagnostic odds ratio, and area under the ROC curve were calculated. Results: IBP was present in 23.5% of the patients. Alterations in depth of breathing (sensitivity 96%, negative likelihood ratio 0.11%) and pursed-lip breathing (sensitivity 99%, negative likelihood ratio 0.07%) were the most sensitive de fi ning characteristics for IBP, while altered chest excursion (speci fi city 97%, positive likelihood ratio 11.41%) and prolonged expiration phase (speci fi city 99%, positive likelihood ratio 42.39%) were the most speci fi c. Conclusion: Some clinical indicators were more related to the presence or absence of IBP than others. Knowledge of such measures can help nurses to assess patients more accurately.Applied Nursing Research2017-07-25T14:06:57Z2017-07-25T14:06:57Z2016-11info:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/articleapplication/pdfSOUSA, V. E. C. de et al. Ineffective breathing pattern in cardiac postoperative patients : diagnostic accuracy study. Applied Nursing Research, Philadelphia, v. 32, p. 134-138, nov. 2016.0897-1897http://www.repositorio.ufc.br/handle/riufc/24246Sousa, Vanessa Emille Carvalho dePascoal, Lívia MaiaNascimento, Ranielly Vidal doMatos, Talita Ferreira Oliveira deBeltrão, Beatriz AmorimSilva, Viviane Martins daLopes, Marcos Venícios de Oliveiraengreponame:Repositório Institucional da Universidade Federal do Ceará (UFC)instname:Universidade Federal do Ceará (UFC)instacron:UFCinfo:eu-repo/semantics/openAccess2019-02-05T11:55:03Zoai:repositorio.ufc.br:riufc/24246Repositório InstitucionalPUBhttp://www.repositorio.ufc.br/ri-oai/requestbu@ufc.br || repositorio@ufc.bropendoar:2024-09-11T18:31:55.668712Repositório Institucional da Universidade Federal do Ceará (UFC) - Universidade Federal do Ceará (UFC)false
dc.title.none.fl_str_mv Ineffective breathing pattern in cardiac postoperative patients : diagnostic accuracy study
title Ineffective breathing pattern in cardiac postoperative patients : diagnostic accuracy study
spellingShingle Ineffective breathing pattern in cardiac postoperative patients : diagnostic accuracy study
Sousa, Vanessa Emille Carvalho de
Diagnóstico de Enfermagem
Cuidados Pós-Operatórios
Postoperative Care
title_short Ineffective breathing pattern in cardiac postoperative patients : diagnostic accuracy study
title_full Ineffective breathing pattern in cardiac postoperative patients : diagnostic accuracy study
title_fullStr Ineffective breathing pattern in cardiac postoperative patients : diagnostic accuracy study
title_full_unstemmed Ineffective breathing pattern in cardiac postoperative patients : diagnostic accuracy study
title_sort Ineffective breathing pattern in cardiac postoperative patients : diagnostic accuracy study
author Sousa, Vanessa Emille Carvalho de
author_facet Sousa, Vanessa Emille Carvalho de
Pascoal, Lívia Maia
Nascimento, Ranielly Vidal do
Matos, Talita Ferreira Oliveira de
Beltrão, Beatriz Amorim
Silva, Viviane Martins da
Lopes, Marcos Venícios de Oliveira
author_role author
author2 Pascoal, Lívia Maia
Nascimento, Ranielly Vidal do
Matos, Talita Ferreira Oliveira de
Beltrão, Beatriz Amorim
Silva, Viviane Martins da
Lopes, Marcos Venícios de Oliveira
author2_role author
author
author
author
author
author
dc.contributor.author.fl_str_mv Sousa, Vanessa Emille Carvalho de
Pascoal, Lívia Maia
Nascimento, Ranielly Vidal do
Matos, Talita Ferreira Oliveira de
Beltrão, Beatriz Amorim
Silva, Viviane Martins da
Lopes, Marcos Venícios de Oliveira
dc.subject.por.fl_str_mv Diagnóstico de Enfermagem
Cuidados Pós-Operatórios
Postoperative Care
topic Diagnóstico de Enfermagem
Cuidados Pós-Operatórios
Postoperative Care
description Purpose: The aim of this study was to analyze the accuracy of the de fi ning characteristics of ineffective breathing pattern (IBP) in postoperative cardiac patients. Methods: A diagnostic accuracy study was performed with 98 patients. Measures of sensitivity, speci fi city, predictive values, likelihood ratios, diagnostic odds ratio, and area under the ROC curve were calculated. Results: IBP was present in 23.5% of the patients. Alterations in depth of breathing (sensitivity 96%, negative likelihood ratio 0.11%) and pursed-lip breathing (sensitivity 99%, negative likelihood ratio 0.07%) were the most sensitive de fi ning characteristics for IBP, while altered chest excursion (speci fi city 97%, positive likelihood ratio 11.41%) and prolonged expiration phase (speci fi city 99%, positive likelihood ratio 42.39%) were the most speci fi c. Conclusion: Some clinical indicators were more related to the presence or absence of IBP than others. Knowledge of such measures can help nurses to assess patients more accurately.
publishDate 2016
dc.date.none.fl_str_mv 2016-11
2017-07-25T14:06:57Z
2017-07-25T14:06:57Z
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
dc.type.driver.fl_str_mv info:eu-repo/semantics/article
format article
status_str publishedVersion
dc.identifier.uri.fl_str_mv SOUSA, V. E. C. de et al. Ineffective breathing pattern in cardiac postoperative patients : diagnostic accuracy study. Applied Nursing Research, Philadelphia, v. 32, p. 134-138, nov. 2016.
0897-1897
http://www.repositorio.ufc.br/handle/riufc/24246
identifier_str_mv SOUSA, V. E. C. de et al. Ineffective breathing pattern in cardiac postoperative patients : diagnostic accuracy study. Applied Nursing Research, Philadelphia, v. 32, p. 134-138, nov. 2016.
0897-1897
url http://www.repositorio.ufc.br/handle/riufc/24246
dc.language.iso.fl_str_mv eng
language eng
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv application/pdf
dc.publisher.none.fl_str_mv Applied Nursing Research
publisher.none.fl_str_mv Applied Nursing Research
dc.source.none.fl_str_mv reponame:Repositório Institucional da Universidade Federal do Ceará (UFC)
instname:Universidade Federal do Ceará (UFC)
instacron:UFC
instname_str Universidade Federal do Ceará (UFC)
instacron_str UFC
institution UFC
reponame_str Repositório Institucional da Universidade Federal do Ceará (UFC)
collection Repositório Institucional da Universidade Federal do Ceará (UFC)
repository.name.fl_str_mv Repositório Institucional da Universidade Federal do Ceará (UFC) - Universidade Federal do Ceará (UFC)
repository.mail.fl_str_mv bu@ufc.br || repositorio@ufc.br
_version_ 1813028843538087936