Ineffective breathing pattern in cardiac postoperative patients : diagnostic accuracy study
Autor(a) principal: | |
---|---|
Data de Publicação: | 2016 |
Outros Autores: | , , , , , |
Tipo de documento: | Artigo |
Idioma: | eng |
Título da fonte: | Repositório Institucional da Universidade Federal do Ceará (UFC) |
Texto Completo: | http://www.repositorio.ufc.br/handle/riufc/24246 |
Resumo: | Purpose: The aim of this study was to analyze the accuracy of the de fi ning characteristics of ineffective breathing pattern (IBP) in postoperative cardiac patients. Methods: A diagnostic accuracy study was performed with 98 patients. Measures of sensitivity, speci fi city, predictive values, likelihood ratios, diagnostic odds ratio, and area under the ROC curve were calculated. Results: IBP was present in 23.5% of the patients. Alterations in depth of breathing (sensitivity 96%, negative likelihood ratio 0.11%) and pursed-lip breathing (sensitivity 99%, negative likelihood ratio 0.07%) were the most sensitive de fi ning characteristics for IBP, while altered chest excursion (speci fi city 97%, positive likelihood ratio 11.41%) and prolonged expiration phase (speci fi city 99%, positive likelihood ratio 42.39%) were the most speci fi c. Conclusion: Some clinical indicators were more related to the presence or absence of IBP than others. Knowledge of such measures can help nurses to assess patients more accurately. |
id |
UFC-7_5fd66c1e44bdb5a3c5909047bfdb4ce0 |
---|---|
oai_identifier_str |
oai:repositorio.ufc.br:riufc/24246 |
network_acronym_str |
UFC-7 |
network_name_str |
Repositório Institucional da Universidade Federal do Ceará (UFC) |
repository_id_str |
|
spelling |
Ineffective breathing pattern in cardiac postoperative patients : diagnostic accuracy studyDiagnóstico de EnfermagemCuidados Pós-OperatóriosPostoperative CarePurpose: The aim of this study was to analyze the accuracy of the de fi ning characteristics of ineffective breathing pattern (IBP) in postoperative cardiac patients. Methods: A diagnostic accuracy study was performed with 98 patients. Measures of sensitivity, speci fi city, predictive values, likelihood ratios, diagnostic odds ratio, and area under the ROC curve were calculated. Results: IBP was present in 23.5% of the patients. Alterations in depth of breathing (sensitivity 96%, negative likelihood ratio 0.11%) and pursed-lip breathing (sensitivity 99%, negative likelihood ratio 0.07%) were the most sensitive de fi ning characteristics for IBP, while altered chest excursion (speci fi city 97%, positive likelihood ratio 11.41%) and prolonged expiration phase (speci fi city 99%, positive likelihood ratio 42.39%) were the most speci fi c. Conclusion: Some clinical indicators were more related to the presence or absence of IBP than others. Knowledge of such measures can help nurses to assess patients more accurately.Applied Nursing Research2017-07-25T14:06:57Z2017-07-25T14:06:57Z2016-11info:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/articleapplication/pdfSOUSA, V. E. C. de et al. Ineffective breathing pattern in cardiac postoperative patients : diagnostic accuracy study. Applied Nursing Research, Philadelphia, v. 32, p. 134-138, nov. 2016.0897-1897http://www.repositorio.ufc.br/handle/riufc/24246Sousa, Vanessa Emille Carvalho dePascoal, Lívia MaiaNascimento, Ranielly Vidal doMatos, Talita Ferreira Oliveira deBeltrão, Beatriz AmorimSilva, Viviane Martins daLopes, Marcos Venícios de Oliveiraengreponame:Repositório Institucional da Universidade Federal do Ceará (UFC)instname:Universidade Federal do Ceará (UFC)instacron:UFCinfo:eu-repo/semantics/openAccess2019-02-05T11:55:03Zoai:repositorio.ufc.br:riufc/24246Repositório InstitucionalPUBhttp://www.repositorio.ufc.br/ri-oai/requestbu@ufc.br || repositorio@ufc.bropendoar:2024-09-11T18:31:55.668712Repositório Institucional da Universidade Federal do Ceará (UFC) - Universidade Federal do Ceará (UFC)false |
dc.title.none.fl_str_mv |
Ineffective breathing pattern in cardiac postoperative patients : diagnostic accuracy study |
title |
Ineffective breathing pattern in cardiac postoperative patients : diagnostic accuracy study |
spellingShingle |
Ineffective breathing pattern in cardiac postoperative patients : diagnostic accuracy study Sousa, Vanessa Emille Carvalho de Diagnóstico de Enfermagem Cuidados Pós-Operatórios Postoperative Care |
title_short |
Ineffective breathing pattern in cardiac postoperative patients : diagnostic accuracy study |
title_full |
Ineffective breathing pattern in cardiac postoperative patients : diagnostic accuracy study |
title_fullStr |
Ineffective breathing pattern in cardiac postoperative patients : diagnostic accuracy study |
title_full_unstemmed |
Ineffective breathing pattern in cardiac postoperative patients : diagnostic accuracy study |
title_sort |
Ineffective breathing pattern in cardiac postoperative patients : diagnostic accuracy study |
author |
Sousa, Vanessa Emille Carvalho de |
author_facet |
Sousa, Vanessa Emille Carvalho de Pascoal, Lívia Maia Nascimento, Ranielly Vidal do Matos, Talita Ferreira Oliveira de Beltrão, Beatriz Amorim Silva, Viviane Martins da Lopes, Marcos Venícios de Oliveira |
author_role |
author |
author2 |
Pascoal, Lívia Maia Nascimento, Ranielly Vidal do Matos, Talita Ferreira Oliveira de Beltrão, Beatriz Amorim Silva, Viviane Martins da Lopes, Marcos Venícios de Oliveira |
author2_role |
author author author author author author |
dc.contributor.author.fl_str_mv |
Sousa, Vanessa Emille Carvalho de Pascoal, Lívia Maia Nascimento, Ranielly Vidal do Matos, Talita Ferreira Oliveira de Beltrão, Beatriz Amorim Silva, Viviane Martins da Lopes, Marcos Venícios de Oliveira |
dc.subject.por.fl_str_mv |
Diagnóstico de Enfermagem Cuidados Pós-Operatórios Postoperative Care |
topic |
Diagnóstico de Enfermagem Cuidados Pós-Operatórios Postoperative Care |
description |
Purpose: The aim of this study was to analyze the accuracy of the de fi ning characteristics of ineffective breathing pattern (IBP) in postoperative cardiac patients. Methods: A diagnostic accuracy study was performed with 98 patients. Measures of sensitivity, speci fi city, predictive values, likelihood ratios, diagnostic odds ratio, and area under the ROC curve were calculated. Results: IBP was present in 23.5% of the patients. Alterations in depth of breathing (sensitivity 96%, negative likelihood ratio 0.11%) and pursed-lip breathing (sensitivity 99%, negative likelihood ratio 0.07%) were the most sensitive de fi ning characteristics for IBP, while altered chest excursion (speci fi city 97%, positive likelihood ratio 11.41%) and prolonged expiration phase (speci fi city 99%, positive likelihood ratio 42.39%) were the most speci fi c. Conclusion: Some clinical indicators were more related to the presence or absence of IBP than others. Knowledge of such measures can help nurses to assess patients more accurately. |
publishDate |
2016 |
dc.date.none.fl_str_mv |
2016-11 2017-07-25T14:06:57Z 2017-07-25T14:06:57Z |
dc.type.status.fl_str_mv |
info:eu-repo/semantics/publishedVersion |
dc.type.driver.fl_str_mv |
info:eu-repo/semantics/article |
format |
article |
status_str |
publishedVersion |
dc.identifier.uri.fl_str_mv |
SOUSA, V. E. C. de et al. Ineffective breathing pattern in cardiac postoperative patients : diagnostic accuracy study. Applied Nursing Research, Philadelphia, v. 32, p. 134-138, nov. 2016. 0897-1897 http://www.repositorio.ufc.br/handle/riufc/24246 |
identifier_str_mv |
SOUSA, V. E. C. de et al. Ineffective breathing pattern in cardiac postoperative patients : diagnostic accuracy study. Applied Nursing Research, Philadelphia, v. 32, p. 134-138, nov. 2016. 0897-1897 |
url |
http://www.repositorio.ufc.br/handle/riufc/24246 |
dc.language.iso.fl_str_mv |
eng |
language |
eng |
dc.rights.driver.fl_str_mv |
info:eu-repo/semantics/openAccess |
eu_rights_str_mv |
openAccess |
dc.format.none.fl_str_mv |
application/pdf |
dc.publisher.none.fl_str_mv |
Applied Nursing Research |
publisher.none.fl_str_mv |
Applied Nursing Research |
dc.source.none.fl_str_mv |
reponame:Repositório Institucional da Universidade Federal do Ceará (UFC) instname:Universidade Federal do Ceará (UFC) instacron:UFC |
instname_str |
Universidade Federal do Ceará (UFC) |
instacron_str |
UFC |
institution |
UFC |
reponame_str |
Repositório Institucional da Universidade Federal do Ceará (UFC) |
collection |
Repositório Institucional da Universidade Federal do Ceará (UFC) |
repository.name.fl_str_mv |
Repositório Institucional da Universidade Federal do Ceará (UFC) - Universidade Federal do Ceará (UFC) |
repository.mail.fl_str_mv |
bu@ufc.br || repositorio@ufc.br |
_version_ |
1813028843538087936 |