Performance control of root piles using a digital odometer
Autor(a) principal: | |
---|---|
Data de Publicação: | 2022 |
Outros Autores: | , |
Tipo de documento: | Artigo |
Idioma: | eng |
Título da fonte: | Repositório Institucional da Universidade Federal do Ceará (UFC) |
Texto Completo: | http://www.repositorio.ufc.br/handle/riufc/68836 |
Resumo: | Root piles are injected and installed during mortar shaft construction, using pressures of up to 500 kPa. The executive control is typically done through static load testing, an expensive and time-consuming method. Static load tests on eight controlled piles (diameters between 310 mm and 410 mm) were performed, aiming at evaluating pile ultimate load. This study suggests an innovative, non-destructive approach to validate root pile field performance, using a digital speedometer connected to the drilling rig’s rotating head. The proposed method monitors variables related to bearing capacity during pile installation and proposes an empirical equation to estimate the ultimate bearing capacity of root piles. For the assessed piles, the predictions obtained with the proposed equations agreed fairly well with results from static load tests, proving it as a feasible and helpful option for the executive control of root piles, especially when load tests are not available. |
id |
UFC-7_93efb56278963918cdb6aff99c4568a9 |
---|---|
oai_identifier_str |
oai:repositorio.ufc.br:riufc/68836 |
network_acronym_str |
UFC-7 |
network_name_str |
Repositório Institucional da Universidade Federal do Ceará (UFC) |
repository_id_str |
|
spelling |
Performance control of root piles using a digital odometerControl del rendimiento de pilotes tipo raíz mediante un odómetro digitalFoundationsPilesStatic load testMicropilesRoot pilesPile bearing capacityQuality controlFundações (Engenharia) - Controle de qualidadeEstacas de concreto - Controle de qualidadeCapacidade de cargaRoot piles are injected and installed during mortar shaft construction, using pressures of up to 500 kPa. The executive control is typically done through static load testing, an expensive and time-consuming method. Static load tests on eight controlled piles (diameters between 310 mm and 410 mm) were performed, aiming at evaluating pile ultimate load. This study suggests an innovative, non-destructive approach to validate root pile field performance, using a digital speedometer connected to the drilling rig’s rotating head. The proposed method monitors variables related to bearing capacity during pile installation and proposes an empirical equation to estimate the ultimate bearing capacity of root piles. For the assessed piles, the predictions obtained with the proposed equations agreed fairly well with results from static load tests, proving it as a feasible and helpful option for the executive control of root piles, especially when load tests are not available.El control ejecutivo generalmente se realiza mediante pruebas de carga estática, un método costoso y que requiere mucho tiempo. Se realizaron ensayos de carga estática en ocho pilotes controlados con el objetivo de evaluar la carga última. Este estudio sugiere un enfoque innovador y no destructivo para validar el rendimiento del campo de pilotes de raíces, utilizando un velocímetro digital conectado al cabezal giratorio del equipo de perforación. El método propuesto monitorea las variables relacionadas con la capacidad portante durante la instalación del pilote y propone una ecuación empírica para estimar la capacidad portante última de los pilotes raíz. Para los pilotes evaluados, las predicciones obtenidas con las ecuaciones propuestas coincidieron, así como con los resultados de las pruebas de carga estática, lo que la demuestra como una opción factible y útil para el control ejecutivo de pilotes de raíz, especialmente cuando no se dispone de pruebas de carga.Revista DYNA2022-10-15T18:51:39Z2022-10-15T18:51:39Z2022info:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/articleapplication/pdfMOURA, Alfran Sampaio; MONTEIRO, Fernando Feitosa; MELCHIOR FILHO, José. Performance control of root piles using a digital odometer. Revista DYNA, Colômbia, v. 89, n. 220, p. 64-71, jan./mar. 2022. DOI: https://doi.org/10.15446/dyna.v89n220.950080012-7353http://www.repositorio.ufc.br/handle/riufc/68836Melchior Filho, JoséMoura, Alfran SampaioMonteiro, Fernando Feitosainfo:eu-repo/semantics/openAccessengreponame:Repositório Institucional da Universidade Federal do Ceará (UFC)instname:Universidade Federal do Ceará (UFC)instacron:UFC2023-12-06T17:50:36Zoai:repositorio.ufc.br:riufc/68836Repositório InstitucionalPUBhttp://www.repositorio.ufc.br/ri-oai/requestbu@ufc.br || repositorio@ufc.bropendoar:2024-09-11T18:17:21.108806Repositório Institucional da Universidade Federal do Ceará (UFC) - Universidade Federal do Ceará (UFC)false |
dc.title.none.fl_str_mv |
Performance control of root piles using a digital odometer Control del rendimiento de pilotes tipo raíz mediante un odómetro digital |
title |
Performance control of root piles using a digital odometer |
spellingShingle |
Performance control of root piles using a digital odometer Melchior Filho, José Foundations Piles Static load test Micropiles Root piles Pile bearing capacity Quality control Fundações (Engenharia) - Controle de qualidade Estacas de concreto - Controle de qualidade Capacidade de carga |
title_short |
Performance control of root piles using a digital odometer |
title_full |
Performance control of root piles using a digital odometer |
title_fullStr |
Performance control of root piles using a digital odometer |
title_full_unstemmed |
Performance control of root piles using a digital odometer |
title_sort |
Performance control of root piles using a digital odometer |
author |
Melchior Filho, José |
author_facet |
Melchior Filho, José Moura, Alfran Sampaio Monteiro, Fernando Feitosa |
author_role |
author |
author2 |
Moura, Alfran Sampaio Monteiro, Fernando Feitosa |
author2_role |
author author |
dc.contributor.author.fl_str_mv |
Melchior Filho, José Moura, Alfran Sampaio Monteiro, Fernando Feitosa |
dc.subject.por.fl_str_mv |
Foundations Piles Static load test Micropiles Root piles Pile bearing capacity Quality control Fundações (Engenharia) - Controle de qualidade Estacas de concreto - Controle de qualidade Capacidade de carga |
topic |
Foundations Piles Static load test Micropiles Root piles Pile bearing capacity Quality control Fundações (Engenharia) - Controle de qualidade Estacas de concreto - Controle de qualidade Capacidade de carga |
description |
Root piles are injected and installed during mortar shaft construction, using pressures of up to 500 kPa. The executive control is typically done through static load testing, an expensive and time-consuming method. Static load tests on eight controlled piles (diameters between 310 mm and 410 mm) were performed, aiming at evaluating pile ultimate load. This study suggests an innovative, non-destructive approach to validate root pile field performance, using a digital speedometer connected to the drilling rig’s rotating head. The proposed method monitors variables related to bearing capacity during pile installation and proposes an empirical equation to estimate the ultimate bearing capacity of root piles. For the assessed piles, the predictions obtained with the proposed equations agreed fairly well with results from static load tests, proving it as a feasible and helpful option for the executive control of root piles, especially when load tests are not available. |
publishDate |
2022 |
dc.date.none.fl_str_mv |
2022-10-15T18:51:39Z 2022-10-15T18:51:39Z 2022 |
dc.type.status.fl_str_mv |
info:eu-repo/semantics/publishedVersion |
dc.type.driver.fl_str_mv |
info:eu-repo/semantics/article |
format |
article |
status_str |
publishedVersion |
dc.identifier.uri.fl_str_mv |
MOURA, Alfran Sampaio; MONTEIRO, Fernando Feitosa; MELCHIOR FILHO, José. Performance control of root piles using a digital odometer. Revista DYNA, Colômbia, v. 89, n. 220, p. 64-71, jan./mar. 2022. DOI: https://doi.org/10.15446/dyna.v89n220.95008 0012-7353 http://www.repositorio.ufc.br/handle/riufc/68836 |
identifier_str_mv |
MOURA, Alfran Sampaio; MONTEIRO, Fernando Feitosa; MELCHIOR FILHO, José. Performance control of root piles using a digital odometer. Revista DYNA, Colômbia, v. 89, n. 220, p. 64-71, jan./mar. 2022. DOI: https://doi.org/10.15446/dyna.v89n220.95008 0012-7353 |
url |
http://www.repositorio.ufc.br/handle/riufc/68836 |
dc.language.iso.fl_str_mv |
eng |
language |
eng |
dc.rights.driver.fl_str_mv |
info:eu-repo/semantics/openAccess |
eu_rights_str_mv |
openAccess |
dc.format.none.fl_str_mv |
application/pdf |
dc.publisher.none.fl_str_mv |
Revista DYNA |
publisher.none.fl_str_mv |
Revista DYNA |
dc.source.none.fl_str_mv |
reponame:Repositório Institucional da Universidade Federal do Ceará (UFC) instname:Universidade Federal do Ceará (UFC) instacron:UFC |
instname_str |
Universidade Federal do Ceará (UFC) |
instacron_str |
UFC |
institution |
UFC |
reponame_str |
Repositório Institucional da Universidade Federal do Ceará (UFC) |
collection |
Repositório Institucional da Universidade Federal do Ceará (UFC) |
repository.name.fl_str_mv |
Repositório Institucional da Universidade Federal do Ceará (UFC) - Universidade Federal do Ceará (UFC) |
repository.mail.fl_str_mv |
bu@ufc.br || repositorio@ufc.br |
_version_ |
1813028739607429120 |