Diagnostic performance of Kato Katz technique and point-of-care circulating cathodic antigen rapid test in diagnosing Schistosoma mansoni infection in HIV-1 co-infected adults on the Shoreline of Lake Victoria, Tanzania
Autor(a) principal: | |
---|---|
Data de Publicação: | 2018 |
Outros Autores: | |
Tipo de documento: | Artigo |
Idioma: | eng |
Título da fonte: | Repositório Institucional da Universidade Federal do Ceará (UFC) |
Texto Completo: | http://www.repositorio.ufc.br/handle/riufc/40794 |
Resumo: | Background: The diagnostic performance of the Kato Katz (KK) technique and the point-of-care circulating cathodic antigen (POC-CCA) test in detecting S. mansoni infection in the presence of the human immunodeficiency virus-1 (HIV-1) infection has remained inconclusive. The present cross-sectional survey compared the diagnostic performance of the KK technique and the POC-CCA test in diagnosing S. mansoni infection in an adult population co-infected with HIV-1 in northwestern Tanzania. Methods: Single urine and stool samples from 979 adults were screened for S. mansoni infection using both the KK technique and POC-CCA tests. To compare the performance of the two diagnostic tests a combined artificial gold standard was created, based on either an egg-positive KK technique or a POC-CCA-positive test. Results: Based on the KK technique, the prevalence of S. mansoni was 47.3% (463/979, 95% CI: 44.2–50.4), as compared to 60.5% by the POC-CCA test (592/979; 95% CI: 57.4–63.5). The overall sensitivity and specificity of the POC-CCA test were 92.5% (95% CI: 89.4–94.9) and 73.3% (95% CI: 69.6–76.8), respectively. In the HIV-1 seropositive group, the sensitivity and specificity of the POC-CCA test were 78.1% (95% CI: 60.0–90.7) and 45.9% (95% CI: 35.8–56.3). Using a combined gold standard, the sensitivity of the POC-CCA test increased to >90% in both subgroups whereas that of the KK technique in the HIV-1 seropositive group was low (49.5%; 95% CI: 39.6–59.5). Conclusion: In the presence of HIV-1 co-infection, the KK technique attained a very low sensitivity. The POC-CCA test offers the best option for the rapid screening of S. mansoni infection in communities with a high prevalence of HIV-1 infection. |
id |
UFC-7_c37e545a8e2f82af904aacbc710963d9 |
---|---|
oai_identifier_str |
oai:repositorio.ufc.br:riufc/40794 |
network_acronym_str |
UFC-7 |
network_name_str |
Repositório Institucional da Universidade Federal do Ceará (UFC) |
repository_id_str |
|
spelling |
Diagnostic performance of Kato Katz technique and point-of-care circulating cathodic antigen rapid test in diagnosing Schistosoma mansoni infection in HIV-1 co-infected adults on the Shoreline of Lake Victoria, TanzaniaSchistosoma mansoniHIV-1Background: The diagnostic performance of the Kato Katz (KK) technique and the point-of-care circulating cathodic antigen (POC-CCA) test in detecting S. mansoni infection in the presence of the human immunodeficiency virus-1 (HIV-1) infection has remained inconclusive. The present cross-sectional survey compared the diagnostic performance of the KK technique and the POC-CCA test in diagnosing S. mansoni infection in an adult population co-infected with HIV-1 in northwestern Tanzania. Methods: Single urine and stool samples from 979 adults were screened for S. mansoni infection using both the KK technique and POC-CCA tests. To compare the performance of the two diagnostic tests a combined artificial gold standard was created, based on either an egg-positive KK technique or a POC-CCA-positive test. Results: Based on the KK technique, the prevalence of S. mansoni was 47.3% (463/979, 95% CI: 44.2–50.4), as compared to 60.5% by the POC-CCA test (592/979; 95% CI: 57.4–63.5). The overall sensitivity and specificity of the POC-CCA test were 92.5% (95% CI: 89.4–94.9) and 73.3% (95% CI: 69.6–76.8), respectively. In the HIV-1 seropositive group, the sensitivity and specificity of the POC-CCA test were 78.1% (95% CI: 60.0–90.7) and 45.9% (95% CI: 35.8–56.3). Using a combined gold standard, the sensitivity of the POC-CCA test increased to >90% in both subgroups whereas that of the KK technique in the HIV-1 seropositive group was low (49.5%; 95% CI: 39.6–59.5). Conclusion: In the presence of HIV-1 co-infection, the KK technique attained a very low sensitivity. The POC-CCA test offers the best option for the rapid screening of S. mansoni infection in communities with a high prevalence of HIV-1 infection.Tropical Medicine and Infectious Disease2019-04-11T15:07:26Z2019-04-11T15:07:26Z2018-05info:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/articleapplication/pdfMAZIGO, Humphrey D. ; HEUKELBACH, Jorg. Diagnostic performance of Kato Katz technique and point-of-care circulating cathodic antigen rapid test in diagnosing Schistosoma mansoni infection in HIV-1 co-infected adults on the Shoreline of Lake Victoria, Tanzania. Trop. Med. Infect. Dis., v. 3, n. 2, p. 1-11, may. 2018.2414-6366http://www.repositorio.ufc.br/handle/riufc/40794Mazigo, Humphrey D.Heukelbach, Jorgengreponame:Repositório Institucional da Universidade Federal do Ceará (UFC)instname:Universidade Federal do Ceará (UFC)instacron:UFCinfo:eu-repo/semantics/openAccess2019-04-11T15:07:26Zoai:repositorio.ufc.br:riufc/40794Repositório InstitucionalPUBhttp://www.repositorio.ufc.br/ri-oai/requestbu@ufc.br || repositorio@ufc.bropendoar:2024-09-11T18:57:06.645600Repositório Institucional da Universidade Federal do Ceará (UFC) - Universidade Federal do Ceará (UFC)false |
dc.title.none.fl_str_mv |
Diagnostic performance of Kato Katz technique and point-of-care circulating cathodic antigen rapid test in diagnosing Schistosoma mansoni infection in HIV-1 co-infected adults on the Shoreline of Lake Victoria, Tanzania |
title |
Diagnostic performance of Kato Katz technique and point-of-care circulating cathodic antigen rapid test in diagnosing Schistosoma mansoni infection in HIV-1 co-infected adults on the Shoreline of Lake Victoria, Tanzania |
spellingShingle |
Diagnostic performance of Kato Katz technique and point-of-care circulating cathodic antigen rapid test in diagnosing Schistosoma mansoni infection in HIV-1 co-infected adults on the Shoreline of Lake Victoria, Tanzania Mazigo, Humphrey D. Schistosoma mansoni HIV-1 |
title_short |
Diagnostic performance of Kato Katz technique and point-of-care circulating cathodic antigen rapid test in diagnosing Schistosoma mansoni infection in HIV-1 co-infected adults on the Shoreline of Lake Victoria, Tanzania |
title_full |
Diagnostic performance of Kato Katz technique and point-of-care circulating cathodic antigen rapid test in diagnosing Schistosoma mansoni infection in HIV-1 co-infected adults on the Shoreline of Lake Victoria, Tanzania |
title_fullStr |
Diagnostic performance of Kato Katz technique and point-of-care circulating cathodic antigen rapid test in diagnosing Schistosoma mansoni infection in HIV-1 co-infected adults on the Shoreline of Lake Victoria, Tanzania |
title_full_unstemmed |
Diagnostic performance of Kato Katz technique and point-of-care circulating cathodic antigen rapid test in diagnosing Schistosoma mansoni infection in HIV-1 co-infected adults on the Shoreline of Lake Victoria, Tanzania |
title_sort |
Diagnostic performance of Kato Katz technique and point-of-care circulating cathodic antigen rapid test in diagnosing Schistosoma mansoni infection in HIV-1 co-infected adults on the Shoreline of Lake Victoria, Tanzania |
author |
Mazigo, Humphrey D. |
author_facet |
Mazigo, Humphrey D. Heukelbach, Jorg |
author_role |
author |
author2 |
Heukelbach, Jorg |
author2_role |
author |
dc.contributor.author.fl_str_mv |
Mazigo, Humphrey D. Heukelbach, Jorg |
dc.subject.por.fl_str_mv |
Schistosoma mansoni HIV-1 |
topic |
Schistosoma mansoni HIV-1 |
description |
Background: The diagnostic performance of the Kato Katz (KK) technique and the point-of-care circulating cathodic antigen (POC-CCA) test in detecting S. mansoni infection in the presence of the human immunodeficiency virus-1 (HIV-1) infection has remained inconclusive. The present cross-sectional survey compared the diagnostic performance of the KK technique and the POC-CCA test in diagnosing S. mansoni infection in an adult population co-infected with HIV-1 in northwestern Tanzania. Methods: Single urine and stool samples from 979 adults were screened for S. mansoni infection using both the KK technique and POC-CCA tests. To compare the performance of the two diagnostic tests a combined artificial gold standard was created, based on either an egg-positive KK technique or a POC-CCA-positive test. Results: Based on the KK technique, the prevalence of S. mansoni was 47.3% (463/979, 95% CI: 44.2–50.4), as compared to 60.5% by the POC-CCA test (592/979; 95% CI: 57.4–63.5). The overall sensitivity and specificity of the POC-CCA test were 92.5% (95% CI: 89.4–94.9) and 73.3% (95% CI: 69.6–76.8), respectively. In the HIV-1 seropositive group, the sensitivity and specificity of the POC-CCA test were 78.1% (95% CI: 60.0–90.7) and 45.9% (95% CI: 35.8–56.3). Using a combined gold standard, the sensitivity of the POC-CCA test increased to >90% in both subgroups whereas that of the KK technique in the HIV-1 seropositive group was low (49.5%; 95% CI: 39.6–59.5). Conclusion: In the presence of HIV-1 co-infection, the KK technique attained a very low sensitivity. The POC-CCA test offers the best option for the rapid screening of S. mansoni infection in communities with a high prevalence of HIV-1 infection. |
publishDate |
2018 |
dc.date.none.fl_str_mv |
2018-05 2019-04-11T15:07:26Z 2019-04-11T15:07:26Z |
dc.type.status.fl_str_mv |
info:eu-repo/semantics/publishedVersion |
dc.type.driver.fl_str_mv |
info:eu-repo/semantics/article |
format |
article |
status_str |
publishedVersion |
dc.identifier.uri.fl_str_mv |
MAZIGO, Humphrey D. ; HEUKELBACH, Jorg. Diagnostic performance of Kato Katz technique and point-of-care circulating cathodic antigen rapid test in diagnosing Schistosoma mansoni infection in HIV-1 co-infected adults on the Shoreline of Lake Victoria, Tanzania. Trop. Med. Infect. Dis., v. 3, n. 2, p. 1-11, may. 2018. 2414-6366 http://www.repositorio.ufc.br/handle/riufc/40794 |
identifier_str_mv |
MAZIGO, Humphrey D. ; HEUKELBACH, Jorg. Diagnostic performance of Kato Katz technique and point-of-care circulating cathodic antigen rapid test in diagnosing Schistosoma mansoni infection in HIV-1 co-infected adults on the Shoreline of Lake Victoria, Tanzania. Trop. Med. Infect. Dis., v. 3, n. 2, p. 1-11, may. 2018. 2414-6366 |
url |
http://www.repositorio.ufc.br/handle/riufc/40794 |
dc.language.iso.fl_str_mv |
eng |
language |
eng |
dc.rights.driver.fl_str_mv |
info:eu-repo/semantics/openAccess |
eu_rights_str_mv |
openAccess |
dc.format.none.fl_str_mv |
application/pdf |
dc.publisher.none.fl_str_mv |
Tropical Medicine and Infectious Disease |
publisher.none.fl_str_mv |
Tropical Medicine and Infectious Disease |
dc.source.none.fl_str_mv |
reponame:Repositório Institucional da Universidade Federal do Ceará (UFC) instname:Universidade Federal do Ceará (UFC) instacron:UFC |
instname_str |
Universidade Federal do Ceará (UFC) |
instacron_str |
UFC |
institution |
UFC |
reponame_str |
Repositório Institucional da Universidade Federal do Ceará (UFC) |
collection |
Repositório Institucional da Universidade Federal do Ceará (UFC) |
repository.name.fl_str_mv |
Repositório Institucional da Universidade Federal do Ceará (UFC) - Universidade Federal do Ceará (UFC) |
repository.mail.fl_str_mv |
bu@ufc.br || repositorio@ufc.br |
_version_ |
1813029009457414144 |