Sequence networks to the calculation of two-simultaneous faults at the same location
Autor(a) principal: | |
---|---|
Data de Publicação: | 2015 |
Outros Autores: | , |
Tipo de documento: | Artigo |
Idioma: | por |
Título da fonte: | Repositório Institucional da Universidade Federal do Ceará (UFC) |
Texto Completo: | http://www.repositorio.ufc.br/handle/riufc/64469 |
Resumo: | The system of symmetrical components (012-system) can be used to simulate symmetrical and asymmetrical operation of power systems. However, the classical literature of Power Systems Analysis does not present one equivalent circuit in 012-system to two-simultaneous faults where there are a single-line-to-ground fault and a bolted line-to-line fault. This paper presents the equations and the new equivalent circuit mentioned. In addition, we present a comparison of results between the proposed approach and the output of the commercial software ANAFAS, which validates the methodology. We find evidence that the new equivalent circuit developed can substitute the equivalent circuits used to calculate a single line-to-ground fault and a bolted line-to-line fault. |
id |
UFC-7_d536c470d76af1911fa629a3a0910200 |
---|---|
oai_identifier_str |
oai:repositorio.ufc.br:riufc/64469 |
network_acronym_str |
UFC-7 |
network_name_str |
Repositório Institucional da Universidade Federal do Ceará (UFC) |
repository_id_str |
|
spelling |
Sequence networks to the calculation of two-simultaneous faults at the same locationSequence networks to the calculation of two-simultaneous faults at the same locationFaultPower systemSequence networksSymmetrical componentsThe system of symmetrical components (012-system) can be used to simulate symmetrical and asymmetrical operation of power systems. However, the classical literature of Power Systems Analysis does not present one equivalent circuit in 012-system to two-simultaneous faults where there are a single-line-to-ground fault and a bolted line-to-line fault. This paper presents the equations and the new equivalent circuit mentioned. In addition, we present a comparison of results between the proposed approach and the output of the commercial software ANAFAS, which validates the methodology. We find evidence that the new equivalent circuit developed can substitute the equivalent circuits used to calculate a single line-to-ground fault and a bolted line-to-line fault.Elsevier Ltd. - https://reader.elsevier.com/2022-03-17T16:30:12Z2022-03-17T16:30:12Z2015info:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/articleapplication/pdfMOURA, Ailson Pereira de; LOPES, Joao Abel Peças; MOURA, Adriano Aron Freitas de. Sequence networks to the calculation of two-simultaneous faults at the same location. International Journal of Electrical Power & Energy Systems, v. 69, p. 414-420, jul. 2015.0142-0615http://www.repositorio.ufc.br/handle/riufc/64469Moura, Ailson Pereira deLopes, Joao Abel PeçasMoura, Adriano Aron Freitas deinfo:eu-repo/semantics/openAccessporreponame:Repositório Institucional da Universidade Federal do Ceará (UFC)instname:Universidade Federal do Ceará (UFC)instacron:UFC2023-12-06T17:09:35Zoai:repositorio.ufc.br:riufc/64469Repositório InstitucionalPUBhttp://www.repositorio.ufc.br/ri-oai/requestbu@ufc.br || repositorio@ufc.bropendoar:2024-09-11T18:19:12.220332Repositório Institucional da Universidade Federal do Ceará (UFC) - Universidade Federal do Ceará (UFC)false |
dc.title.none.fl_str_mv |
Sequence networks to the calculation of two-simultaneous faults at the same location Sequence networks to the calculation of two-simultaneous faults at the same location |
title |
Sequence networks to the calculation of two-simultaneous faults at the same location |
spellingShingle |
Sequence networks to the calculation of two-simultaneous faults at the same location Moura, Ailson Pereira de Fault Power system Sequence networks Symmetrical components |
title_short |
Sequence networks to the calculation of two-simultaneous faults at the same location |
title_full |
Sequence networks to the calculation of two-simultaneous faults at the same location |
title_fullStr |
Sequence networks to the calculation of two-simultaneous faults at the same location |
title_full_unstemmed |
Sequence networks to the calculation of two-simultaneous faults at the same location |
title_sort |
Sequence networks to the calculation of two-simultaneous faults at the same location |
author |
Moura, Ailson Pereira de |
author_facet |
Moura, Ailson Pereira de Lopes, Joao Abel Peças Moura, Adriano Aron Freitas de |
author_role |
author |
author2 |
Lopes, Joao Abel Peças Moura, Adriano Aron Freitas de |
author2_role |
author author |
dc.contributor.author.fl_str_mv |
Moura, Ailson Pereira de Lopes, Joao Abel Peças Moura, Adriano Aron Freitas de |
dc.subject.por.fl_str_mv |
Fault Power system Sequence networks Symmetrical components |
topic |
Fault Power system Sequence networks Symmetrical components |
description |
The system of symmetrical components (012-system) can be used to simulate symmetrical and asymmetrical operation of power systems. However, the classical literature of Power Systems Analysis does not present one equivalent circuit in 012-system to two-simultaneous faults where there are a single-line-to-ground fault and a bolted line-to-line fault. This paper presents the equations and the new equivalent circuit mentioned. In addition, we present a comparison of results between the proposed approach and the output of the commercial software ANAFAS, which validates the methodology. We find evidence that the new equivalent circuit developed can substitute the equivalent circuits used to calculate a single line-to-ground fault and a bolted line-to-line fault. |
publishDate |
2015 |
dc.date.none.fl_str_mv |
2015 2022-03-17T16:30:12Z 2022-03-17T16:30:12Z |
dc.type.status.fl_str_mv |
info:eu-repo/semantics/publishedVersion |
dc.type.driver.fl_str_mv |
info:eu-repo/semantics/article |
format |
article |
status_str |
publishedVersion |
dc.identifier.uri.fl_str_mv |
MOURA, Ailson Pereira de; LOPES, Joao Abel Peças; MOURA, Adriano Aron Freitas de. Sequence networks to the calculation of two-simultaneous faults at the same location. International Journal of Electrical Power & Energy Systems, v. 69, p. 414-420, jul. 2015. 0142-0615 http://www.repositorio.ufc.br/handle/riufc/64469 |
identifier_str_mv |
MOURA, Ailson Pereira de; LOPES, Joao Abel Peças; MOURA, Adriano Aron Freitas de. Sequence networks to the calculation of two-simultaneous faults at the same location. International Journal of Electrical Power & Energy Systems, v. 69, p. 414-420, jul. 2015. 0142-0615 |
url |
http://www.repositorio.ufc.br/handle/riufc/64469 |
dc.language.iso.fl_str_mv |
por |
language |
por |
dc.rights.driver.fl_str_mv |
info:eu-repo/semantics/openAccess |
eu_rights_str_mv |
openAccess |
dc.format.none.fl_str_mv |
application/pdf |
dc.publisher.none.fl_str_mv |
Elsevier Ltd. - https://reader.elsevier.com/ |
publisher.none.fl_str_mv |
Elsevier Ltd. - https://reader.elsevier.com/ |
dc.source.none.fl_str_mv |
reponame:Repositório Institucional da Universidade Federal do Ceará (UFC) instname:Universidade Federal do Ceará (UFC) instacron:UFC |
instname_str |
Universidade Federal do Ceará (UFC) |
instacron_str |
UFC |
institution |
UFC |
reponame_str |
Repositório Institucional da Universidade Federal do Ceará (UFC) |
collection |
Repositório Institucional da Universidade Federal do Ceará (UFC) |
repository.name.fl_str_mv |
Repositório Institucional da Universidade Federal do Ceará (UFC) - Universidade Federal do Ceará (UFC) |
repository.mail.fl_str_mv |
bu@ufc.br || repositorio@ufc.br |
_version_ |
1813028753130913792 |