Resumo: The IxV curves tracers for PV modules are used as a method of diagnosis of problems such as shadowing, faulty connections and degradation conditions. There are several types and brands tracers commercially available, but their costs are quite high in the Brazilian market due to the need to import. This thesis describes the development and validation of a IxV curve tracer for PV modules based on the electronic load method using MOSFET as load to the module. By appropriate variation of the MOSFET gate-source voltage signal was possible to acquire the points of voltage and current of the PV modules terminals. These points were recorded using a data acquisition board with PIC18F2550, which is controlled by a computer via a USB with a graphical interface to the user. This interface was developed in MATLAB software ensuring greater flexibility and functionality to the device. For PV module temperature measurements PT100 sensors were used and measurements of solar irradiance was used a pyranometer LP02 model Hukseflux Thermal Sensor manufacturer, these sensors were connected to a supervisory system consists of a PC and a programmable logic controller (PLC). The validation process was conducted by comparing the electrical parameters provided by the developed tracer and the commercial tracer MINI-KLA. From this comparison an error was generated for each parameter. Three PV modules of different electrical characteristics (20 Wp, 87 Wp e 160 Wp) were used and there was similarity between the curves of the developed tracer with the curves of the commercial tracer. The average of errors of the electrical parameters for the 3 PV modules was less than 5% at no shading conditions. In two conditions of shading, the IxV curves provided by the two tracers for the KC 85 T PV module were compared and it was observed in the first situation that the MINI-KLA tracer could characterize only partially the curve while the tracer developed could characterize the curve fully, in the second situation there was great similarity between the curves of the two tracers with maximum percentage difference in the electrical parameters equal to 5.41%.
id UFC_32ba73f03a3b9fa92fc1df68b866c13b
oai_identifier_str oai:www.teses.ufc.br:11133
network_acronym_str UFC
network_name_str Biblioteca Digital de Teses e Dissertações da UFC
spelling info:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/masterThesisDevelopment and validation of I x V curve tracer for photovoltaic modulesDesenvolvimento e validaÃÃo de traÃador de curva I x V para mÃdulos fotovoltaicos2016-05-02Paulo CÃsar Marques de Carvalho00000000117http://lattes.cnpq.br/0935409654079900SÃrgio Daher38805197300http://lattes.cnpq.br/7235893980985596Elissandro Monteiro do Sacramento79626084391http://buscatextual.cnpq.br/buscatextual/visualizacv.do?id=K4537608D6Fernando Luiz Marcelo Antunes0729577430004407076330MÃrcio Leal Macedo LunaUniversidade Federal do CearÃPrograma de PÃs-GraduaÃÃo em Engenharia ElÃtricaUFCBREnergia solar MÃdulos FV TraÃador de curva IxVSolar energy PV modules IxV Curve tracerCIRCUITOS ELETRONICOSThe IxV curves tracers for PV modules are used as a method of diagnosis of problems such as shadowing, faulty connections and degradation conditions. There are several types and brands tracers commercially available, but their costs are quite high in the Brazilian market due to the need to import. This thesis describes the development and validation of a IxV curve tracer for PV modules based on the electronic load method using MOSFET as load to the module. By appropriate variation of the MOSFET gate-source voltage signal was possible to acquire the points of voltage and current of the PV modules terminals. These points were recorded using a data acquisition board with PIC18F2550, which is controlled by a computer via a USB with a graphical interface to the user. This interface was developed in MATLAB software ensuring greater flexibility and functionality to the device. For PV module temperature measurements PT100 sensors were used and measurements of solar irradiance was used a pyranometer LP02 model Hukseflux Thermal Sensor manufacturer, these sensors were connected to a supervisory system consists of a PC and a programmable logic controller (PLC). The validation process was conducted by comparing the electrical parameters provided by the developed tracer and the commercial tracer MINI-KLA. From this comparison an error was generated for each parameter. Three PV modules of different electrical characteristics (20 Wp, 87 Wp e 160 Wp) were used and there was similarity between the curves of the developed tracer with the curves of the commercial tracer. The average of errors of the electrical parameters for the 3 PV modules was less than 5% at no shading conditions. In two conditions of shading, the IxV curves provided by the two tracers for the KC 85 T PV module were compared and it was observed in the first situation that the MINI-KLA tracer could characterize only partially the curve while the tracer developed could characterize the curve fully, in the second situation there was great similarity between the curves of the two tracers with maximum percentage difference in the electrical parameters equal to 5.41%.Os traÃadores de curva IxV para mÃdulos FV sÃo utilizados como um mÃtodo de diagnÃstico de problemas como sombreamento, conexÃes defeituosas e condiÃÃes de degradaÃÃo. Existem diversos tipos e marcas de traÃadores disponibilizados comercialmente, mas seus custos sÃo bastante elevados no mercado brasileiro devido à necessidade de importaÃÃo. A presente dissertaÃÃo aborda o desenvolvimento e a validaÃÃo de um traÃador de curva IxV para mÃdulos FV baseado no mÃtodo de carga eletrÃnica com uso de MOSFET como carga para o mÃdulo. AtravÃs da adequada variaÃÃo do sinal de tensÃo de gate-source do MOSFET foi possÃvel adquirir os pontos de tensÃo e corrente nos terminais dos mÃdulos FV. Estes pontos foram registrados atravÃs de uma placa de aquisiÃÃo de dados, com PIC18F2550, que à controlada via USB por um computador com uma interface grÃfica para usuÃrio. Esta interface foi desenvolvida com o software MATLAB, garantindo maior flexibilidade e funcionalidade ao dispositivo. Para mediÃÃes da temperatura do mÃdulo FV foram utilizados sensores PT100 e para as mediÃÃes de irradiÃncia solar foi utilizado um piranÃmetro modelo LP02 do fabricante Hukseflux Thermal Sensor; estes sensores foram utilizados atravÃs de um sistema supervisÃrio composto por um PC e um controlador lÃgico programÃvel (CLP). O processo de validaÃÃo foi realizado atravÃs da comparaÃÃo dos parÃmetros elÃtricos fornecidos pelo traÃador desenvolvido e pelo traÃador comercial MINI-KLA. A partir desta comparaÃÃo um erro foi gerado para cada parÃmetro. Foram utilizados 3 mÃdulos FV de diferentes caracterÃsticas elÃtricas (20 Wp, 87 Wp e 160 Wp) e observou-se proximidade entre as curvas do traÃador desenvolvido com as curvas do traÃador comercial. A mÃdia dos erros para os 3 mÃdulos relativa aos parÃmetros elÃtricos obtidos com os 2 traÃadores foi inferior a 5% em condiÃÃes sem sombreamento. Em duas condiÃÃes de sombreamento, as curvas IxV fornecidas pelos dois traÃadores relativas ao mÃdulo FV KC 85 T foram comparadas e observou-se na primeira situaÃÃo que o traÃador MINI-KLA conseguiu caracterizar apenas parcialmente a curva enquanto que o traÃador desenvolvido conseguiu caracterizar a curva totalmente, na segunda situaÃÃo observou-se grande proximidade entre as curvas dos dois traÃadores com diferenÃa percentual mÃxima nos parÃmetros elÃtricos igual a 5,41%.CoordenaÃÃo de AperfeiÃoamento de Pessoal de NÃvel Superiorhttp://www.teses.ufc.br/tde_busca/arquivo.php?codArquivo=17151application/pdfinfo:eu-repo/semantics/openAccessporreponame:Biblioteca Digital de Teses e Dissertações da UFCinstname:Universidade Federal do Cearáinstacron:UFC2019-01-21T11:30:36Zmail@mail.com -
dc.title.en.fl_str_mv Development and validation of I x V curve tracer for photovoltaic modules
dc.title.alternative.pt.fl_str_mv Desenvolvimento e validaÃÃo de traÃador de curva I x V para mÃdulos fotovoltaicos
title Development and validation of I x V curve tracer for photovoltaic modules
spellingShingle Development and validation of I x V curve tracer for photovoltaic modules
MÃrcio Leal Macedo Luna
Energia solar
MÃdulos FV
TraÃador de curva IxV
Solar energy
PV modules
IxV Curve tracer
CIRCUITOS ELETRONICOS
title_short Development and validation of I x V curve tracer for photovoltaic modules
title_full Development and validation of I x V curve tracer for photovoltaic modules
title_fullStr Development and validation of I x V curve tracer for photovoltaic modules
title_full_unstemmed Development and validation of I x V curve tracer for photovoltaic modules
title_sort Development and validation of I x V curve tracer for photovoltaic modules
author MÃrcio Leal Macedo Luna
author_facet MÃrcio Leal Macedo Luna
author_role author
dc.contributor.advisor1.fl_str_mv Paulo CÃsar Marques de Carvalho
dc.contributor.advisor1ID.fl_str_mv 00000000117
dc.contributor.advisor1Lattes.fl_str_mv http://lattes.cnpq.br/0935409654079900
dc.contributor.advisor-co1.fl_str_mv SÃrgio Daher
dc.contributor.advisor-co1ID.fl_str_mv 38805197300
dc.contributor.advisor-co1Lattes.fl_str_mv http://lattes.cnpq.br/7235893980985596
dc.contributor.referee1.fl_str_mv Elissandro Monteiro do Sacramento
dc.contributor.referee1ID.fl_str_mv 79626084391
dc.contributor.referee1Lattes.fl_str_mv http://buscatextual.cnpq.br/buscatextual/visualizacv.do?id=K4537608D6
dc.contributor.referee2.fl_str_mv Fernando Luiz Marcelo Antunes
dc.contributor.referee2ID.fl_str_mv 07295774300
dc.contributor.authorID.fl_str_mv 04407076330
dc.contributor.author.fl_str_mv MÃrcio Leal Macedo Luna
contributor_str_mv Paulo CÃsar Marques de Carvalho
SÃrgio Daher
Elissandro Monteiro do Sacramento
Fernando Luiz Marcelo Antunes
dc.subject.por.fl_str_mv Energia solar
MÃdulos FV
TraÃador de curva IxV
topic Energia solar
MÃdulos FV
TraÃador de curva IxV
Solar energy
PV modules
IxV Curve tracer
CIRCUITOS ELETRONICOS
dc.subject.eng.fl_str_mv Solar energy
PV modules
IxV Curve tracer
dc.subject.cnpq.fl_str_mv CIRCUITOS ELETRONICOS
dc.description.sponsorship.fl_txt_mv CoordenaÃÃo de AperfeiÃoamento de Pessoal de NÃvel Superior
dc.description.abstract.por.fl_txt_mv The IxV curves tracers for PV modules are used as a method of diagnosis of problems such as shadowing, faulty connections and degradation conditions. There are several types and brands tracers commercially available, but their costs are quite high in the Brazilian market due to the need to import. This thesis describes the development and validation of a IxV curve tracer for PV modules based on the electronic load method using MOSFET as load to the module. By appropriate variation of the MOSFET gate-source voltage signal was possible to acquire the points of voltage and current of the PV modules terminals. These points were recorded using a data acquisition board with PIC18F2550, which is controlled by a computer via a USB with a graphical interface to the user. This interface was developed in MATLAB software ensuring greater flexibility and functionality to the device. For PV module temperature measurements PT100 sensors were used and measurements of solar irradiance was used a pyranometer LP02 model Hukseflux Thermal Sensor manufacturer, these sensors were connected to a supervisory system consists of a PC and a programmable logic controller (PLC). The validation process was conducted by comparing the electrical parameters provided by the developed tracer and the commercial tracer MINI-KLA. From this comparison an error was generated for each parameter. Three PV modules of different electrical characteristics (20 Wp, 87 Wp e 160 Wp) were used and there was similarity between the curves of the developed tracer with the curves of the commercial tracer. The average of errors of the electrical parameters for the 3 PV modules was less than 5% at no shading conditions. In two conditions of shading, the IxV curves provided by the two tracers for the KC 85 T PV module were compared and it was observed in the first situation that the MINI-KLA tracer could characterize only partially the curve while the tracer developed could characterize the curve fully, in the second situation there was great similarity between the curves of the two tracers with maximum percentage difference in the electrical parameters equal to 5.41%.
Os traÃadores de curva IxV para mÃdulos FV sÃo utilizados como um mÃtodo de diagnÃstico de problemas como sombreamento, conexÃes defeituosas e condiÃÃes de degradaÃÃo. Existem diversos tipos e marcas de traÃadores disponibilizados comercialmente, mas seus custos sÃo bastante elevados no mercado brasileiro devido à necessidade de importaÃÃo. A presente dissertaÃÃo aborda o desenvolvimento e a validaÃÃo de um traÃador de curva IxV para mÃdulos FV baseado no mÃtodo de carga eletrÃnica com uso de MOSFET como carga para o mÃdulo. AtravÃs da adequada variaÃÃo do sinal de tensÃo de gate-source do MOSFET foi possÃvel adquirir os pontos de tensÃo e corrente nos terminais dos mÃdulos FV. Estes pontos foram registrados atravÃs de uma placa de aquisiÃÃo de dados, com PIC18F2550, que à controlada via USB por um computador com uma interface grÃfica para usuÃrio. Esta interface foi desenvolvida com o software MATLAB, garantindo maior flexibilidade e funcionalidade ao dispositivo. Para mediÃÃes da temperatura do mÃdulo FV foram utilizados sensores PT100 e para as mediÃÃes de irradiÃncia solar foi utilizado um piranÃmetro modelo LP02 do fabricante Hukseflux Thermal Sensor; estes sensores foram utilizados atravÃs de um sistema supervisÃrio composto por um PC e um controlador lÃgico programÃvel (CLP). O processo de validaÃÃo foi realizado atravÃs da comparaÃÃo dos parÃmetros elÃtricos fornecidos pelo traÃador desenvolvido e pelo traÃador comercial MINI-KLA. A partir desta comparaÃÃo um erro foi gerado para cada parÃmetro. Foram utilizados 3 mÃdulos FV de diferentes caracterÃsticas elÃtricas (20 Wp, 87 Wp e 160 Wp) e observou-se proximidade entre as curvas do traÃador desenvolvido com as curvas do traÃador comercial. A mÃdia dos erros para os 3 mÃdulos relativa aos parÃmetros elÃtricos obtidos com os 2 traÃadores foi inferior a 5% em condiÃÃes sem sombreamento. Em duas condiÃÃes de sombreamento, as curvas IxV fornecidas pelos dois traÃadores relativas ao mÃdulo FV KC 85 T foram comparadas e observou-se na primeira situaÃÃo que o traÃador MINI-KLA conseguiu caracterizar apenas parcialmente a curva enquanto que o traÃador desenvolvido conseguiu caracterizar a curva totalmente, na segunda situaÃÃo observou-se grande proximidade entre as curvas dos dois traÃadores com diferenÃa percentual mÃxima nos parÃmetros elÃtricos igual a 5,41%.
description The IxV curves tracers for PV modules are used as a method of diagnosis of problems such as shadowing, faulty connections and degradation conditions. There are several types and brands tracers commercially available, but their costs are quite high in the Brazilian market due to the need to import. This thesis describes the development and validation of a IxV curve tracer for PV modules based on the electronic load method using MOSFET as load to the module. By appropriate variation of the MOSFET gate-source voltage signal was possible to acquire the points of voltage and current of the PV modules terminals. These points were recorded using a data acquisition board with PIC18F2550, which is controlled by a computer via a USB with a graphical interface to the user. This interface was developed in MATLAB software ensuring greater flexibility and functionality to the device. For PV module temperature measurements PT100 sensors were used and measurements of solar irradiance was used a pyranometer LP02 model Hukseflux Thermal Sensor manufacturer, these sensors were connected to a supervisory system consists of a PC and a programmable logic controller (PLC). The validation process was conducted by comparing the electrical parameters provided by the developed tracer and the commercial tracer MINI-KLA. From this comparison an error was generated for each parameter. Three PV modules of different electrical characteristics (20 Wp, 87 Wp e 160 Wp) were used and there was similarity between the curves of the developed tracer with the curves of the commercial tracer. The average of errors of the electrical parameters for the 3 PV modules was less than 5% at no shading conditions. In two conditions of shading, the IxV curves provided by the two tracers for the KC 85 T PV module were compared and it was observed in the first situation that the MINI-KLA tracer could characterize only partially the curve while the tracer developed could characterize the curve fully, in the second situation there was great similarity between the curves of the two tracers with maximum percentage difference in the electrical parameters equal to 5.41%.
publishDate 2016
dc.date.issued.fl_str_mv 2016-05-02
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
dc.type.driver.fl_str_mv info:eu-repo/semantics/masterThesis
status_str publishedVersion
format masterThesis
dc.identifier.uri.fl_str_mv http://www.teses.ufc.br/tde_busca/arquivo.php?codArquivo=17151
url http://www.teses.ufc.br/tde_busca/arquivo.php?codArquivo=17151
dc.language.iso.fl_str_mv por
language por
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv application/pdf
dc.publisher.none.fl_str_mv Universidade Federal do CearÃ
dc.publisher.program.fl_str_mv Programa de PÃs-GraduaÃÃo em Engenharia ElÃtrica
dc.publisher.initials.fl_str_mv UFC
dc.publisher.country.fl_str_mv BR
publisher.none.fl_str_mv Universidade Federal do CearÃ
dc.source.none.fl_str_mv reponame:Biblioteca Digital de Teses e Dissertações da UFC
instname:Universidade Federal do Ceará
instacron:UFC
reponame_str Biblioteca Digital de Teses e Dissertações da UFC
collection Biblioteca Digital de Teses e Dissertações da UFC
instname_str Universidade Federal do Ceará
instacron_str UFC
institution UFC
repository.name.fl_str_mv -
repository.mail.fl_str_mv mail@mail.com
_version_ 1643295223987568640