Measurement of evaporation in a tank class systems in aquatic environment and land

Detalhes bibliográficos
Autor(a) principal: FabrÃcio Alves Pinto
Data de Publicação: 2010
Tipo de documento: Dissertação
Idioma: por
Título da fonte: Biblioteca Digital de Teses e Dissertações da UFC
Texto Completo: http://www.teses.ufc.br/tde_busca/arquivo.php?codArquivo=5283
Resumo: The main objective of this research was to compare evaporation measured in two Class A evaporation pans. The first one installed 15 cm over the surface and the second one installed at surface level in a small reservoir. The experiment was carried out at the Fisheries Station of the Federal University of CearÃ, in Fortaleza. An automated weather station was installed at the same site. During February to November of 2008, evaporation data were measured in a daily basis. The weather data were collected in a weekly basis using a radio frequency system. The evaporation measured at a soil surface was 5.3% higher than the evaporation measured at a water surface level of the reservoir. The different installation conditions were influenced differently by the weather parameters. The evaporation estimation methods of Penman, Linsley and Linacre underestimated the evaporation measured in the reservoir, and the Penman method presented the smaller error.
id UFC_dd1820317a66a688b50e9992ca7941eb
oai_identifier_str oai:www.teses.ufc.br:3905
network_acronym_str UFC
network_name_str Biblioteca Digital de Teses e Dissertações da UFC
spelling info:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/masterThesisMeasurement of evaporation in a tank class systems in aquatic environment and landMediÃÃo da evaporaÃÃo em tanques classe a instalados em ambientes aquÃtico e terrestre2010-01-03Renato SÃlvio da Frota Ribeiro08846928334http://lattes.cnpq.br/5332284427390543Thales VinÃcius de AraÃjo Viana24333552320http://lattes.cnpq.br/104990307581306214478720001http://lattes.cnpq.br/1292962190244137 FabrÃcio Alves PintoUniversidade Federal do CearÃPrograma de PÃs-GraduaÃÃo em Engenharia AgrÃcolaUFCBREvaporaÃÃo tanque Classe A radiaÃÃo solar umidade relativa velocidade do vento rÃdio freqÃÃncia.evaporation class A pan solar radiation relative humidity wind speed radio frequency.IRRIGACAO E DRENAGEMThe main objective of this research was to compare evaporation measured in two Class A evaporation pans. The first one installed 15 cm over the surface and the second one installed at surface level in a small reservoir. The experiment was carried out at the Fisheries Station of the Federal University of CearÃ, in Fortaleza. An automated weather station was installed at the same site. During February to November of 2008, evaporation data were measured in a daily basis. The weather data were collected in a weekly basis using a radio frequency system. The evaporation measured at a soil surface was 5.3% higher than the evaporation measured at a water surface level of the reservoir. The different installation conditions were influenced differently by the weather parameters. The evaporation estimation methods of Penman, Linsley and Linacre underestimated the evaporation measured in the reservoir, and the Penman method presented the smaller error.As condiÃÃes climÃticas das regiÃes semi-Ãridas favorecem a evaporaÃÃo que representa a maior perda do volume lÃquido dos aÃudes, portanto, um parÃmetro importante para o gerenciamento dos recursos hÃdricos. Um dos instrumentos mais difundidos e utilizados para estimar a evaporaÃÃo em reservatÃrios à o Tanque Classe A. Assim, este trabalho teve como objetivo principal comparar a evaporaÃÃo medida em dois tanques Classe A, sendo um instalado em ambiente aquÃtico e outro em ambiente terrestre, e como objetivo secundÃrio avaliar estimativas da evaporaÃÃo obtidas pelos mÃtodos propostos por Penman (1948), Linsley (1982) e Linacre (1993) em relaÃÃo Ãs medidas de evaporaÃÃo obtidas nos referidos tanques evaporimÃtricos. O experimento foi conduzido na EstaÃÃo de Piscicultura do Centro de CiÃncias AgrÃrias da Universidade Federal do CearÃ, em Fortaleza, CE. Neste local, alÃm dos tanques Classe A, foi instalada uma estaÃÃo meteorolÃgica automÃtica. No perÃodo de fevereiro a novembro de 2008 foram realizadas medidas diÃrias de evaporaÃÃo e coletados, semanalmente, os dados meteorolÃgicos armazenados no sistema de aquisiÃÃo da estaÃÃo, utilizando rÃdio freqÃÃncia. O total evaporado no tanque Classe A instalado em ambiente terrestre foi 5,3% superior ao total evaporado no tanque Classe A em ambiente aquÃtico. A instalaÃÃo do tanque Classe A em ambiente aquÃtico reduziu os efeitos diretos da radiaÃÃo solar incidente, umidade relativa, temperatura do ar e velocidade do vento sobre a evaporaÃÃo assim com a amplitude tÃrmica da Ãgua no seu interior. O mÃtodo proposto por Penman (1948) apresentou os melhores desempenhos, com erros relativos de -3,0% em relaÃÃo ao tanque Classe A no ambiente aquÃtico e -7,9% em relaÃÃo ao tanque Classe A no ambiente terrestre.Conselho Nacional de Desenvolvimento CientÃfico e TecnolÃgicohttp://www.teses.ufc.br/tde_busca/arquivo.php?codArquivo=5283application/pdfinfo:eu-repo/semantics/openAccessporreponame:Biblioteca Digital de Teses e Dissertações da UFCinstname:Universidade Federal do Cearáinstacron:UFC2019-01-21T11:18:22Zmail@mail.com -
dc.title.en.fl_str_mv Measurement of evaporation in a tank class systems in aquatic environment and land
dc.title.alternative.pt.fl_str_mv MediÃÃo da evaporaÃÃo em tanques classe a instalados em ambientes aquÃtico e terrestre
title Measurement of evaporation in a tank class systems in aquatic environment and land
spellingShingle Measurement of evaporation in a tank class systems in aquatic environment and land
FabrÃcio Alves Pinto
EvaporaÃÃo
tanque Classe A
radiaÃÃo solar
umidade relativa
velocidade do vento
rÃdio freqÃÃncia.
evaporation
class A pan
solar radiation
relative humidity
wind speed
radio frequency.
IRRIGACAO E DRENAGEM
title_short Measurement of evaporation in a tank class systems in aquatic environment and land
title_full Measurement of evaporation in a tank class systems in aquatic environment and land
title_fullStr Measurement of evaporation in a tank class systems in aquatic environment and land
title_full_unstemmed Measurement of evaporation in a tank class systems in aquatic environment and land
title_sort Measurement of evaporation in a tank class systems in aquatic environment and land
author FabrÃcio Alves Pinto
author_facet FabrÃcio Alves Pinto
author_role author
dc.contributor.advisor1.fl_str_mv Renato SÃlvio da Frota Ribeiro
dc.contributor.advisor1ID.fl_str_mv 08846928334
dc.contributor.advisor1Lattes.fl_str_mv http://lattes.cnpq.br/5332284427390543
dc.contributor.referee1.fl_str_mv Thales VinÃcius de AraÃjo Viana
dc.contributor.referee1ID.fl_str_mv 24333552320
dc.contributor.referee1Lattes.fl_str_mv http://lattes.cnpq.br/1049903075813062
dc.contributor.authorID.fl_str_mv 14478720001
dc.contributor.authorLattes.fl_str_mv http://lattes.cnpq.br/1292962190244137
dc.contributor.author.fl_str_mv FabrÃcio Alves Pinto
contributor_str_mv Renato SÃlvio da Frota Ribeiro
Thales VinÃcius de AraÃjo Viana
dc.subject.por.fl_str_mv EvaporaÃÃo
tanque Classe A
radiaÃÃo solar
umidade relativa
velocidade do vento
rÃdio freqÃÃncia.
topic EvaporaÃÃo
tanque Classe A
radiaÃÃo solar
umidade relativa
velocidade do vento
rÃdio freqÃÃncia.
evaporation
class A pan
solar radiation
relative humidity
wind speed
radio frequency.
IRRIGACAO E DRENAGEM
dc.subject.eng.fl_str_mv evaporation
class A pan
solar radiation
relative humidity
wind speed
radio frequency.
dc.subject.cnpq.fl_str_mv IRRIGACAO E DRENAGEM
dc.description.sponsorship.fl_txt_mv Conselho Nacional de Desenvolvimento CientÃfico e TecnolÃgico
dc.description.abstract.por.fl_txt_mv The main objective of this research was to compare evaporation measured in two Class A evaporation pans. The first one installed 15 cm over the surface and the second one installed at surface level in a small reservoir. The experiment was carried out at the Fisheries Station of the Federal University of CearÃ, in Fortaleza. An automated weather station was installed at the same site. During February to November of 2008, evaporation data were measured in a daily basis. The weather data were collected in a weekly basis using a radio frequency system. The evaporation measured at a soil surface was 5.3% higher than the evaporation measured at a water surface level of the reservoir. The different installation conditions were influenced differently by the weather parameters. The evaporation estimation methods of Penman, Linsley and Linacre underestimated the evaporation measured in the reservoir, and the Penman method presented the smaller error.
As condiÃÃes climÃticas das regiÃes semi-Ãridas favorecem a evaporaÃÃo que representa a maior perda do volume lÃquido dos aÃudes, portanto, um parÃmetro importante para o gerenciamento dos recursos hÃdricos. Um dos instrumentos mais difundidos e utilizados para estimar a evaporaÃÃo em reservatÃrios à o Tanque Classe A. Assim, este trabalho teve como objetivo principal comparar a evaporaÃÃo medida em dois tanques Classe A, sendo um instalado em ambiente aquÃtico e outro em ambiente terrestre, e como objetivo secundÃrio avaliar estimativas da evaporaÃÃo obtidas pelos mÃtodos propostos por Penman (1948), Linsley (1982) e Linacre (1993) em relaÃÃo Ãs medidas de evaporaÃÃo obtidas nos referidos tanques evaporimÃtricos. O experimento foi conduzido na EstaÃÃo de Piscicultura do Centro de CiÃncias AgrÃrias da Universidade Federal do CearÃ, em Fortaleza, CE. Neste local, alÃm dos tanques Classe A, foi instalada uma estaÃÃo meteorolÃgica automÃtica. No perÃodo de fevereiro a novembro de 2008 foram realizadas medidas diÃrias de evaporaÃÃo e coletados, semanalmente, os dados meteorolÃgicos armazenados no sistema de aquisiÃÃo da estaÃÃo, utilizando rÃdio freqÃÃncia. O total evaporado no tanque Classe A instalado em ambiente terrestre foi 5,3% superior ao total evaporado no tanque Classe A em ambiente aquÃtico. A instalaÃÃo do tanque Classe A em ambiente aquÃtico reduziu os efeitos diretos da radiaÃÃo solar incidente, umidade relativa, temperatura do ar e velocidade do vento sobre a evaporaÃÃo assim com a amplitude tÃrmica da Ãgua no seu interior. O mÃtodo proposto por Penman (1948) apresentou os melhores desempenhos, com erros relativos de -3,0% em relaÃÃo ao tanque Classe A no ambiente aquÃtico e -7,9% em relaÃÃo ao tanque Classe A no ambiente terrestre.
description The main objective of this research was to compare evaporation measured in two Class A evaporation pans. The first one installed 15 cm over the surface and the second one installed at surface level in a small reservoir. The experiment was carried out at the Fisheries Station of the Federal University of CearÃ, in Fortaleza. An automated weather station was installed at the same site. During February to November of 2008, evaporation data were measured in a daily basis. The weather data were collected in a weekly basis using a radio frequency system. The evaporation measured at a soil surface was 5.3% higher than the evaporation measured at a water surface level of the reservoir. The different installation conditions were influenced differently by the weather parameters. The evaporation estimation methods of Penman, Linsley and Linacre underestimated the evaporation measured in the reservoir, and the Penman method presented the smaller error.
publishDate 2010
dc.date.issued.fl_str_mv 2010-01-03
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
dc.type.driver.fl_str_mv info:eu-repo/semantics/masterThesis
status_str publishedVersion
format masterThesis
dc.identifier.uri.fl_str_mv http://www.teses.ufc.br/tde_busca/arquivo.php?codArquivo=5283
url http://www.teses.ufc.br/tde_busca/arquivo.php?codArquivo=5283
dc.language.iso.fl_str_mv por
language por
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv application/pdf
dc.publisher.none.fl_str_mv Universidade Federal do CearÃ
dc.publisher.program.fl_str_mv Programa de PÃs-GraduaÃÃo em Engenharia AgrÃcola
dc.publisher.initials.fl_str_mv UFC
dc.publisher.country.fl_str_mv BR
publisher.none.fl_str_mv Universidade Federal do CearÃ
dc.source.none.fl_str_mv reponame:Biblioteca Digital de Teses e Dissertações da UFC
instname:Universidade Federal do Ceará
instacron:UFC
reponame_str Biblioteca Digital de Teses e Dissertações da UFC
collection Biblioteca Digital de Teses e Dissertações da UFC
instname_str Universidade Federal do Ceará
instacron_str UFC
institution UFC
repository.name.fl_str_mv -
repository.mail.fl_str_mv mail@mail.com
_version_ 1643295144218198016