Measurement of evaporation in a tank class systems in aquatic environment and land
Autor(a) principal: | |
---|---|
Data de Publicação: | 2010 |
Tipo de documento: | Dissertação |
Idioma: | por |
Título da fonte: | Biblioteca Digital de Teses e Dissertações da UFC |
Texto Completo: | http://www.teses.ufc.br/tde_busca/arquivo.php?codArquivo=5283 |
Resumo: | The main objective of this research was to compare evaporation measured in two Class A evaporation pans. The first one installed 15 cm over the surface and the second one installed at surface level in a small reservoir. The experiment was carried out at the Fisheries Station of the Federal University of CearÃ, in Fortaleza. An automated weather station was installed at the same site. During February to November of 2008, evaporation data were measured in a daily basis. The weather data were collected in a weekly basis using a radio frequency system. The evaporation measured at a soil surface was 5.3% higher than the evaporation measured at a water surface level of the reservoir. The different installation conditions were influenced differently by the weather parameters. The evaporation estimation methods of Penman, Linsley and Linacre underestimated the evaporation measured in the reservoir, and the Penman method presented the smaller error. |
id |
UFC_dd1820317a66a688b50e9992ca7941eb |
---|---|
oai_identifier_str |
oai:www.teses.ufc.br:3905 |
network_acronym_str |
UFC |
network_name_str |
Biblioteca Digital de Teses e Dissertações da UFC |
spelling |
info:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/masterThesisMeasurement of evaporation in a tank class systems in aquatic environment and landMediÃÃo da evaporaÃÃo em tanques classe a instalados em ambientes aquÃtico e terrestre2010-01-03Renato SÃlvio da Frota Ribeiro08846928334http://lattes.cnpq.br/5332284427390543Thales VinÃcius de AraÃjo Viana24333552320http://lattes.cnpq.br/104990307581306214478720001http://lattes.cnpq.br/1292962190244137 FabrÃcio Alves PintoUniversidade Federal do CearÃPrograma de PÃs-GraduaÃÃo em Engenharia AgrÃcolaUFCBREvaporaÃÃo tanque Classe A radiaÃÃo solar umidade relativa velocidade do vento rÃdio freqÃÃncia.evaporation class A pan solar radiation relative humidity wind speed radio frequency.IRRIGACAO E DRENAGEMThe main objective of this research was to compare evaporation measured in two Class A evaporation pans. The first one installed 15 cm over the surface and the second one installed at surface level in a small reservoir. The experiment was carried out at the Fisheries Station of the Federal University of CearÃ, in Fortaleza. An automated weather station was installed at the same site. During February to November of 2008, evaporation data were measured in a daily basis. The weather data were collected in a weekly basis using a radio frequency system. The evaporation measured at a soil surface was 5.3% higher than the evaporation measured at a water surface level of the reservoir. The different installation conditions were influenced differently by the weather parameters. The evaporation estimation methods of Penman, Linsley and Linacre underestimated the evaporation measured in the reservoir, and the Penman method presented the smaller error.As condiÃÃes climÃticas das regiÃes semi-Ãridas favorecem a evaporaÃÃo que representa a maior perda do volume lÃquido dos aÃudes, portanto, um parÃmetro importante para o gerenciamento dos recursos hÃdricos. Um dos instrumentos mais difundidos e utilizados para estimar a evaporaÃÃo em reservatÃrios à o Tanque Classe A. Assim, este trabalho teve como objetivo principal comparar a evaporaÃÃo medida em dois tanques Classe A, sendo um instalado em ambiente aquÃtico e outro em ambiente terrestre, e como objetivo secundÃrio avaliar estimativas da evaporaÃÃo obtidas pelos mÃtodos propostos por Penman (1948), Linsley (1982) e Linacre (1993) em relaÃÃo Ãs medidas de evaporaÃÃo obtidas nos referidos tanques evaporimÃtricos. O experimento foi conduzido na EstaÃÃo de Piscicultura do Centro de CiÃncias AgrÃrias da Universidade Federal do CearÃ, em Fortaleza, CE. Neste local, alÃm dos tanques Classe A, foi instalada uma estaÃÃo meteorolÃgica automÃtica. No perÃodo de fevereiro a novembro de 2008 foram realizadas medidas diÃrias de evaporaÃÃo e coletados, semanalmente, os dados meteorolÃgicos armazenados no sistema de aquisiÃÃo da estaÃÃo, utilizando rÃdio freqÃÃncia. O total evaporado no tanque Classe A instalado em ambiente terrestre foi 5,3% superior ao total evaporado no tanque Classe A em ambiente aquÃtico. A instalaÃÃo do tanque Classe A em ambiente aquÃtico reduziu os efeitos diretos da radiaÃÃo solar incidente, umidade relativa, temperatura do ar e velocidade do vento sobre a evaporaÃÃo assim com a amplitude tÃrmica da Ãgua no seu interior. O mÃtodo proposto por Penman (1948) apresentou os melhores desempenhos, com erros relativos de -3,0% em relaÃÃo ao tanque Classe A no ambiente aquÃtico e -7,9% em relaÃÃo ao tanque Classe A no ambiente terrestre.Conselho Nacional de Desenvolvimento CientÃfico e TecnolÃgicohttp://www.teses.ufc.br/tde_busca/arquivo.php?codArquivo=5283application/pdfinfo:eu-repo/semantics/openAccessporreponame:Biblioteca Digital de Teses e Dissertações da UFCinstname:Universidade Federal do Cearáinstacron:UFC2019-01-21T11:18:22Zmail@mail.com - |
dc.title.en.fl_str_mv |
Measurement of evaporation in a tank class systems in aquatic environment and land |
dc.title.alternative.pt.fl_str_mv |
MediÃÃo da evaporaÃÃo em tanques classe a instalados em ambientes aquÃtico e terrestre |
title |
Measurement of evaporation in a tank class systems in aquatic environment and land |
spellingShingle |
Measurement of evaporation in a tank class systems in aquatic environment and land FabrÃcio Alves Pinto EvaporaÃÃo tanque Classe A radiaÃÃo solar umidade relativa velocidade do vento rÃdio freqÃÃncia. evaporation class A pan solar radiation relative humidity wind speed radio frequency. IRRIGACAO E DRENAGEM |
title_short |
Measurement of evaporation in a tank class systems in aquatic environment and land |
title_full |
Measurement of evaporation in a tank class systems in aquatic environment and land |
title_fullStr |
Measurement of evaporation in a tank class systems in aquatic environment and land |
title_full_unstemmed |
Measurement of evaporation in a tank class systems in aquatic environment and land |
title_sort |
Measurement of evaporation in a tank class systems in aquatic environment and land |
author |
FabrÃcio Alves Pinto |
author_facet |
FabrÃcio Alves Pinto |
author_role |
author |
dc.contributor.advisor1.fl_str_mv |
Renato SÃlvio da Frota Ribeiro |
dc.contributor.advisor1ID.fl_str_mv |
08846928334 |
dc.contributor.advisor1Lattes.fl_str_mv |
http://lattes.cnpq.br/5332284427390543 |
dc.contributor.referee1.fl_str_mv |
Thales VinÃcius de AraÃjo Viana |
dc.contributor.referee1ID.fl_str_mv |
24333552320 |
dc.contributor.referee1Lattes.fl_str_mv |
http://lattes.cnpq.br/1049903075813062 |
dc.contributor.authorID.fl_str_mv |
14478720001 |
dc.contributor.authorLattes.fl_str_mv |
http://lattes.cnpq.br/1292962190244137 |
dc.contributor.author.fl_str_mv |
FabrÃcio Alves Pinto |
contributor_str_mv |
Renato SÃlvio da Frota Ribeiro Thales VinÃcius de AraÃjo Viana |
dc.subject.por.fl_str_mv |
EvaporaÃÃo tanque Classe A radiaÃÃo solar umidade relativa velocidade do vento rÃdio freqÃÃncia. |
topic |
EvaporaÃÃo tanque Classe A radiaÃÃo solar umidade relativa velocidade do vento rÃdio freqÃÃncia. evaporation class A pan solar radiation relative humidity wind speed radio frequency. IRRIGACAO E DRENAGEM |
dc.subject.eng.fl_str_mv |
evaporation class A pan solar radiation relative humidity wind speed radio frequency. |
dc.subject.cnpq.fl_str_mv |
IRRIGACAO E DRENAGEM |
dc.description.sponsorship.fl_txt_mv |
Conselho Nacional de Desenvolvimento CientÃfico e TecnolÃgico |
dc.description.abstract.por.fl_txt_mv |
The main objective of this research was to compare evaporation measured in two Class A evaporation pans. The first one installed 15 cm over the surface and the second one installed at surface level in a small reservoir. The experiment was carried out at the Fisheries Station of the Federal University of CearÃ, in Fortaleza. An automated weather station was installed at the same site. During February to November of 2008, evaporation data were measured in a daily basis. The weather data were collected in a weekly basis using a radio frequency system. The evaporation measured at a soil surface was 5.3% higher than the evaporation measured at a water surface level of the reservoir. The different installation conditions were influenced differently by the weather parameters. The evaporation estimation methods of Penman, Linsley and Linacre underestimated the evaporation measured in the reservoir, and the Penman method presented the smaller error. As condiÃÃes climÃticas das regiÃes semi-Ãridas favorecem a evaporaÃÃo que representa a maior perda do volume lÃquido dos aÃudes, portanto, um parÃmetro importante para o gerenciamento dos recursos hÃdricos. Um dos instrumentos mais difundidos e utilizados para estimar a evaporaÃÃo em reservatÃrios à o Tanque Classe A. Assim, este trabalho teve como objetivo principal comparar a evaporaÃÃo medida em dois tanques Classe A, sendo um instalado em ambiente aquÃtico e outro em ambiente terrestre, e como objetivo secundÃrio avaliar estimativas da evaporaÃÃo obtidas pelos mÃtodos propostos por Penman (1948), Linsley (1982) e Linacre (1993) em relaÃÃo Ãs medidas de evaporaÃÃo obtidas nos referidos tanques evaporimÃtricos. O experimento foi conduzido na EstaÃÃo de Piscicultura do Centro de CiÃncias AgrÃrias da Universidade Federal do CearÃ, em Fortaleza, CE. Neste local, alÃm dos tanques Classe A, foi instalada uma estaÃÃo meteorolÃgica automÃtica. No perÃodo de fevereiro a novembro de 2008 foram realizadas medidas diÃrias de evaporaÃÃo e coletados, semanalmente, os dados meteorolÃgicos armazenados no sistema de aquisiÃÃo da estaÃÃo, utilizando rÃdio freqÃÃncia. O total evaporado no tanque Classe A instalado em ambiente terrestre foi 5,3% superior ao total evaporado no tanque Classe A em ambiente aquÃtico. A instalaÃÃo do tanque Classe A em ambiente aquÃtico reduziu os efeitos diretos da radiaÃÃo solar incidente, umidade relativa, temperatura do ar e velocidade do vento sobre a evaporaÃÃo assim com a amplitude tÃrmica da Ãgua no seu interior. O mÃtodo proposto por Penman (1948) apresentou os melhores desempenhos, com erros relativos de -3,0% em relaÃÃo ao tanque Classe A no ambiente aquÃtico e -7,9% em relaÃÃo ao tanque Classe A no ambiente terrestre. |
description |
The main objective of this research was to compare evaporation measured in two Class A evaporation pans. The first one installed 15 cm over the surface and the second one installed at surface level in a small reservoir. The experiment was carried out at the Fisheries Station of the Federal University of CearÃ, in Fortaleza. An automated weather station was installed at the same site. During February to November of 2008, evaporation data were measured in a daily basis. The weather data were collected in a weekly basis using a radio frequency system. The evaporation measured at a soil surface was 5.3% higher than the evaporation measured at a water surface level of the reservoir. The different installation conditions were influenced differently by the weather parameters. The evaporation estimation methods of Penman, Linsley and Linacre underestimated the evaporation measured in the reservoir, and the Penman method presented the smaller error. |
publishDate |
2010 |
dc.date.issued.fl_str_mv |
2010-01-03 |
dc.type.status.fl_str_mv |
info:eu-repo/semantics/publishedVersion |
dc.type.driver.fl_str_mv |
info:eu-repo/semantics/masterThesis |
status_str |
publishedVersion |
format |
masterThesis |
dc.identifier.uri.fl_str_mv |
http://www.teses.ufc.br/tde_busca/arquivo.php?codArquivo=5283 |
url |
http://www.teses.ufc.br/tde_busca/arquivo.php?codArquivo=5283 |
dc.language.iso.fl_str_mv |
por |
language |
por |
dc.rights.driver.fl_str_mv |
info:eu-repo/semantics/openAccess |
eu_rights_str_mv |
openAccess |
dc.format.none.fl_str_mv |
application/pdf |
dc.publisher.none.fl_str_mv |
Universidade Federal do Cearà |
dc.publisher.program.fl_str_mv |
Programa de PÃs-GraduaÃÃo em Engenharia AgrÃcola |
dc.publisher.initials.fl_str_mv |
UFC |
dc.publisher.country.fl_str_mv |
BR |
publisher.none.fl_str_mv |
Universidade Federal do Cearà |
dc.source.none.fl_str_mv |
reponame:Biblioteca Digital de Teses e Dissertações da UFC instname:Universidade Federal do Ceará instacron:UFC |
reponame_str |
Biblioteca Digital de Teses e Dissertações da UFC |
collection |
Biblioteca Digital de Teses e Dissertações da UFC |
instname_str |
Universidade Federal do Ceará |
instacron_str |
UFC |
institution |
UFC |
repository.name.fl_str_mv |
-
|
repository.mail.fl_str_mv |
mail@mail.com |
_version_ |
1643295144218198016 |