Optical fiber sensing for sub-millimeter intrinsically-safe liquid level monitoring

Detalhes bibliográficos
Autor(a) principal: Rodríguez Díaz, Camilo Arturo
Data de Publicação: 2018
Tipo de documento: Tese
Idioma: eng
Título da fonte: Repositório Institucional da Universidade Federal do Espírito Santo (riUfes)
Texto Completo: http://repositorio.ufes.br/handle/10/10178
Resumo: The popularization and fast growth of the optical fiber sensing technology has stimulated in different fields WHERE measurements of diverse physical and chemical parameters are required. Among these parameters, liquid level sensing plays an essential role in industry applications such as chemical processing, fuel storage, transportation systems, oil tanks/reservoirs, and wastewater treatment plants. In order to measure this parameter different sensing techniques based on acoustical, mechanical, electrical and electromagnetical technologies have been already proposed. Nevertheless, they suffer from intrinsic safety concerns in harsh environments, especially with corrosive, and explosive or flammable atmospheres. Fiber optic based liquid level sensors (FOLLS) can work in harsh environments with inherent advantageous features that only optical fiber offers, such as intrinsic safety, resistance to chemical corrosion, immunity to electromagnetic interference, electric isolation, small size, lightweight sensing heads, high accuracy and resolution, easy multiplexing, and capability for extremely remote monitoring without the need of electrical power at the measuring point. In this context, this doctoral Thesis presents two specific optical fiber sensor technologies to measure liquid level. Both the MachZehnder and FabryPerot interferometers are researched. The Thesis also focus on uniform fiber Bragg grating (FBG). Since these technologies have different operation principle, the liquid level measurement was based on refractive index changes for the MachZehnder sensor and based on hydrostatic pressure in the case of both the FPI and FBG sensors. Furthermore, analysis of temperature crosssensitivity is performed with the aim to improve the pressurebased sensors performance. Despite the FBGs provide high accurate measurements, the interrogation systems are the most important drawback for their large commercial application, due to their high cost. Therefore, a new and lower cost interrogation technique based on FPI microcavities was proposed as a final contribution.
id UFES_9d8c13037afc5e5e96674d2db0e01fc7
oai_identifier_str oai:repositorio.ufes.br:10/10178
network_acronym_str UFES
network_name_str Repositório Institucional da Universidade Federal do Espírito Santo (riUfes)
repository_id_str 2108
spelling Frizera Neto, AnselmoRibeiro, Moisés Renato NunesRodríguez Díaz, Camilo ArturoSilva, Jean Carlos Cardozo daWerneck, Marcelo MartinsPontes, Maria JoséCastellani, Carlos Eduardo Schmidt2018-08-23T22:06:02Z2018-08-232018-08-23T22:06:02Z2018-06-06The popularization and fast growth of the optical fiber sensing technology has stimulated in different fields WHERE measurements of diverse physical and chemical parameters are required. Among these parameters, liquid level sensing plays an essential role in industry applications such as chemical processing, fuel storage, transportation systems, oil tanks/reservoirs, and wastewater treatment plants. In order to measure this parameter different sensing techniques based on acoustical, mechanical, electrical and electromagnetical technologies have been already proposed. Nevertheless, they suffer from intrinsic safety concerns in harsh environments, especially with corrosive, and explosive or flammable atmospheres. Fiber optic based liquid level sensors (FOLLS) can work in harsh environments with inherent advantageous features that only optical fiber offers, such as intrinsic safety, resistance to chemical corrosion, immunity to electromagnetic interference, electric isolation, small size, lightweight sensing heads, high accuracy and resolution, easy multiplexing, and capability for extremely remote monitoring without the need of electrical power at the measuring point. In this context, this doctoral Thesis presents two specific optical fiber sensor technologies to measure liquid level. Both the MachZehnder and FabryPerot interferometers are researched. The Thesis also focus on uniform fiber Bragg grating (FBG). Since these technologies have different operation principle, the liquid level measurement was based on refractive index changes for the MachZehnder sensor and based on hydrostatic pressure in the case of both the FPI and FBG sensors. Furthermore, analysis of temperature crosssensitivity is performed with the aim to improve the pressurebased sensors performance. Despite the FBGs provide high accurate measurements, the interrogation systems are the most important drawback for their large commercial application, due to their high cost. Therefore, a new and lower cost interrogation technique based on FPI microcavities was proposed as a final contribution.ResumoTexthttp://repositorio.ufes.br/handle/10/10178engUniversidade Federal do Espírito SantoDoutorado em Engenharia ElétricaPrograma de Pós-Graduação em Engenharia ElétricaUFESBRCentro TecnológicoInterferômetro de Mach-ZehnderInterferômetro de Fabry-PerotDetectores ópticosGrades de BraggInterferômetrosIndicadores de nivel liquidoEngenharia Elétrica621.3Optical fiber sensing for sub-millimeter intrinsically-safe liquid level monitoringinfo:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/doctoralThesisinfo:eu-repo/semantics/openAccessreponame:Repositório Institucional da Universidade Federal do Espírito Santo (riUfes)instname:Universidade Federal do Espírito Santo (UFES)instacron:UFESORIGINALtese_8266_Thesis_Final Camilo.pdfapplication/pdf34209018http://repositorio.ufes.br/bitstreams/e306e31b-06c1-45ec-b6f3-8d0b106b7809/downloadf8bbb0b51ae8a11a48c4546685b529d0MD5110/101782024-07-17 16:58:17.245oai:repositorio.ufes.br:10/10178http://repositorio.ufes.brRepositório InstitucionalPUBhttp://repositorio.ufes.br/oai/requestopendoar:21082024-10-15T17:52:11.827201Repositório Institucional da Universidade Federal do Espírito Santo (riUfes) - Universidade Federal do Espírito Santo (UFES)false
dc.title.none.fl_str_mv Optical fiber sensing for sub-millimeter intrinsically-safe liquid level monitoring
title Optical fiber sensing for sub-millimeter intrinsically-safe liquid level monitoring
spellingShingle Optical fiber sensing for sub-millimeter intrinsically-safe liquid level monitoring
Rodríguez Díaz, Camilo Arturo
Interferômetro de Mach-Zehnder
Interferômetro de Fabry-Perot
Engenharia Elétrica
Detectores ópticos
Grades de Bragg
Interferômetros
Indicadores de nivel liquido
621.3
title_short Optical fiber sensing for sub-millimeter intrinsically-safe liquid level monitoring
title_full Optical fiber sensing for sub-millimeter intrinsically-safe liquid level monitoring
title_fullStr Optical fiber sensing for sub-millimeter intrinsically-safe liquid level monitoring
title_full_unstemmed Optical fiber sensing for sub-millimeter intrinsically-safe liquid level monitoring
title_sort Optical fiber sensing for sub-millimeter intrinsically-safe liquid level monitoring
author Rodríguez Díaz, Camilo Arturo
author_facet Rodríguez Díaz, Camilo Arturo
author_role author
dc.contributor.advisor-co1.fl_str_mv Frizera Neto, Anselmo
dc.contributor.advisor1.fl_str_mv Ribeiro, Moisés Renato Nunes
dc.contributor.author.fl_str_mv Rodríguez Díaz, Camilo Arturo
dc.contributor.referee1.fl_str_mv Silva, Jean Carlos Cardozo da
dc.contributor.referee2.fl_str_mv Werneck, Marcelo Martins
dc.contributor.referee3.fl_str_mv Pontes, Maria José
dc.contributor.referee4.fl_str_mv Castellani, Carlos Eduardo Schmidt
contributor_str_mv Frizera Neto, Anselmo
Ribeiro, Moisés Renato Nunes
Silva, Jean Carlos Cardozo da
Werneck, Marcelo Martins
Pontes, Maria José
Castellani, Carlos Eduardo Schmidt
dc.subject.por.fl_str_mv Interferômetro de Mach-Zehnder
Interferômetro de Fabry-Perot
topic Interferômetro de Mach-Zehnder
Interferômetro de Fabry-Perot
Engenharia Elétrica
Detectores ópticos
Grades de Bragg
Interferômetros
Indicadores de nivel liquido
621.3
dc.subject.cnpq.fl_str_mv Engenharia Elétrica
dc.subject.br-rjbn.none.fl_str_mv Detectores ópticos
Grades de Bragg
Interferômetros
Indicadores de nivel liquido
dc.subject.udc.none.fl_str_mv 621.3
description The popularization and fast growth of the optical fiber sensing technology has stimulated in different fields WHERE measurements of diverse physical and chemical parameters are required. Among these parameters, liquid level sensing plays an essential role in industry applications such as chemical processing, fuel storage, transportation systems, oil tanks/reservoirs, and wastewater treatment plants. In order to measure this parameter different sensing techniques based on acoustical, mechanical, electrical and electromagnetical technologies have been already proposed. Nevertheless, they suffer from intrinsic safety concerns in harsh environments, especially with corrosive, and explosive or flammable atmospheres. Fiber optic based liquid level sensors (FOLLS) can work in harsh environments with inherent advantageous features that only optical fiber offers, such as intrinsic safety, resistance to chemical corrosion, immunity to electromagnetic interference, electric isolation, small size, lightweight sensing heads, high accuracy and resolution, easy multiplexing, and capability for extremely remote monitoring without the need of electrical power at the measuring point. In this context, this doctoral Thesis presents two specific optical fiber sensor technologies to measure liquid level. Both the MachZehnder and FabryPerot interferometers are researched. The Thesis also focus on uniform fiber Bragg grating (FBG). Since these technologies have different operation principle, the liquid level measurement was based on refractive index changes for the MachZehnder sensor and based on hydrostatic pressure in the case of both the FPI and FBG sensors. Furthermore, analysis of temperature crosssensitivity is performed with the aim to improve the pressurebased sensors performance. Despite the FBGs provide high accurate measurements, the interrogation systems are the most important drawback for their large commercial application, due to their high cost. Therefore, a new and lower cost interrogation technique based on FPI microcavities was proposed as a final contribution.
publishDate 2018
dc.date.accessioned.fl_str_mv 2018-08-23T22:06:02Z
dc.date.available.fl_str_mv 2018-08-23
2018-08-23T22:06:02Z
dc.date.issued.fl_str_mv 2018-06-06
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
dc.type.driver.fl_str_mv info:eu-repo/semantics/doctoralThesis
format doctoralThesis
status_str publishedVersion
dc.identifier.uri.fl_str_mv http://repositorio.ufes.br/handle/10/10178
url http://repositorio.ufes.br/handle/10/10178
dc.language.iso.fl_str_mv eng
language eng
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv Text
dc.publisher.none.fl_str_mv Universidade Federal do Espírito Santo
Doutorado em Engenharia Elétrica
dc.publisher.program.fl_str_mv Programa de Pós-Graduação em Engenharia Elétrica
dc.publisher.initials.fl_str_mv UFES
dc.publisher.country.fl_str_mv BR
dc.publisher.department.fl_str_mv Centro Tecnológico
publisher.none.fl_str_mv Universidade Federal do Espírito Santo
Doutorado em Engenharia Elétrica
dc.source.none.fl_str_mv reponame:Repositório Institucional da Universidade Federal do Espírito Santo (riUfes)
instname:Universidade Federal do Espírito Santo (UFES)
instacron:UFES
instname_str Universidade Federal do Espírito Santo (UFES)
instacron_str UFES
institution UFES
reponame_str Repositório Institucional da Universidade Federal do Espírito Santo (riUfes)
collection Repositório Institucional da Universidade Federal do Espírito Santo (riUfes)
bitstream.url.fl_str_mv http://repositorio.ufes.br/bitstreams/e306e31b-06c1-45ec-b6f3-8d0b106b7809/download
bitstream.checksum.fl_str_mv f8bbb0b51ae8a11a48c4546685b529d0
bitstream.checksumAlgorithm.fl_str_mv MD5
repository.name.fl_str_mv Repositório Institucional da Universidade Federal do Espírito Santo (riUfes) - Universidade Federal do Espírito Santo (UFES)
repository.mail.fl_str_mv
_version_ 1813022505679454208