A novel stimulation paradigm for a brain-computer interface based on SSVEP

Detalhes bibliográficos
Autor(a) principal: Atencio, Anibal Cotrina
Data de Publicação: 2015
Tipo de documento: Tese
Idioma: eng
Título da fonte: Repositório Institucional da Universidade Federal do Espírito Santo (riUfes)
Texto Completo: http://repositorio.ufes.br/handle/10/9719
Resumo: Brain-computer interfaces (BCIs) are systems that provide a direct connection between users’ brain signals and a computer, generating an alternative channel of communication that does not involve the traditional way as muscles and nerves. They help to restore or replace useful functions of people with paralysis. For instance, BCI systems based on SSVEP (SSVEP-BCI) present a set of stimuli flickering at different frequencies to the users, detect which stimulus is being gazed and associate this information to commands that can be used to control a robotic wheelchair, an exoskeleton, or a speller. Nowadays, SSVEP-BCIs are being widely used due to the high SNR of their response that is achieved when the target stimulus is brought to the center of the user’s field of view. Paradoxically, it is their main disadvantage because bringing a stimulus to the center of the field of view demands muscular activity making them not suitably for paralyzed people who cannot control their head, neck and/or eyeball movements for redirecting their gaze. In optical systems, the range of distance near the point of focus where objects are perceived sharp is referred as Depth-of-field; objects outside this region are defocused and blurred. The mechanism of the visual system that adjusts the eye focal length for focusing does not demand neck, head and/or eyeball movements. Furthermore, ophthalmology studies state that the amplitude and the latency of visual evoked potentials are affected by defocusing. In this context, this Thesis proposes a novel SSVEP-BCI paradigm, in which two stimuli are presented together in the center of the user’s field of view but at different distances from him, ensuring that if one stimulus is focused on, the other one is non-focused, and vice versa; with the aim of providing an alternative way of sending commands through a stimuli selection by a focusing mechanism. In this sense, first, a model of VEP generation for two stimuli is introduced and the hypothesis that distinguishable SSVEP can be elicited by the focused stimulus, regardless of the non-focused stimulus is also present, is tested by employing the SFT-based ORD. Next, a demodulation method based in LPF and HPF is proposed for the case in that two stimuli are present in the field of view; and spatial-temporal retinal response for flickering stimuli is described by using PSF and NPSF functions. Finally, CCA, PSDA, LASSO with EEG signals re-referenced at Pz and CAR are employed to detect the SSVEP pattern. Accuracy rate, Kappa coefficient, AUC, and ITR are used to evaluate the detection performance. As a result of the hypothesis test, the absence of evoked potentials due to a focused stimulus, when a non-focused stimulus is also present was rejected in most of the cases. In SSVEP detection experiments, an average accuracy rate of 0.93 was achieved for a time window of 7s and for eight healthy subjects who were asked to focus on just one stimulus at a time.
id UFES_c2f45b6a8a27de7226b330c76e5cf7c6
oai_identifier_str oai:repositorio.ufes.br:10/9719
network_acronym_str UFES
network_name_str Repositório Institucional da Universidade Federal do Espírito Santo (riUfes)
repository_id_str 2108
spelling Ferreira, AndréBastos Filho,Teodiano FreireAtencio, Anibal CotrinaFrizera Neto, AnselmoSarcinelli Filho, MarioKrohling, Renato AntônioSá, Antonio Mauricio Ferreira Leite Miranda de2018-08-02T00:02:02Z2018-08-012018-08-02T00:02:02Z2015-11-30Brain-computer interfaces (BCIs) are systems that provide a direct connection between users’ brain signals and a computer, generating an alternative channel of communication that does not involve the traditional way as muscles and nerves. They help to restore or replace useful functions of people with paralysis. For instance, BCI systems based on SSVEP (SSVEP-BCI) present a set of stimuli flickering at different frequencies to the users, detect which stimulus is being gazed and associate this information to commands that can be used to control a robotic wheelchair, an exoskeleton, or a speller. Nowadays, SSVEP-BCIs are being widely used due to the high SNR of their response that is achieved when the target stimulus is brought to the center of the user’s field of view. Paradoxically, it is their main disadvantage because bringing a stimulus to the center of the field of view demands muscular activity making them not suitably for paralyzed people who cannot control their head, neck and/or eyeball movements for redirecting their gaze. In optical systems, the range of distance near the point of focus where objects are perceived sharp is referred as Depth-of-field; objects outside this region are defocused and blurred. The mechanism of the visual system that adjusts the eye focal length for focusing does not demand neck, head and/or eyeball movements. Furthermore, ophthalmology studies state that the amplitude and the latency of visual evoked potentials are affected by defocusing. In this context, this Thesis proposes a novel SSVEP-BCI paradigm, in which two stimuli are presented together in the center of the user’s field of view but at different distances from him, ensuring that if one stimulus is focused on, the other one is non-focused, and vice versa; with the aim of providing an alternative way of sending commands through a stimuli selection by a focusing mechanism. In this sense, first, a model of VEP generation for two stimuli is introduced and the hypothesis that distinguishable SSVEP can be elicited by the focused stimulus, regardless of the non-focused stimulus is also present, is tested by employing the SFT-based ORD. Next, a demodulation method based in LPF and HPF is proposed for the case in that two stimuli are present in the field of view; and spatial-temporal retinal response for flickering stimuli is described by using PSF and NPSF functions. Finally, CCA, PSDA, LASSO with EEG signals re-referenced at Pz and CAR are employed to detect the SSVEP pattern. Accuracy rate, Kappa coefficient, AUC, and ITR are used to evaluate the detection performance. As a result of the hypothesis test, the absence of evoked potentials due to a focused stimulus, when a non-focused stimulus is also present was rejected in most of the cases. In SSVEP detection experiments, an average accuracy rate of 0.93 was achieved for a time window of 7s and for eight healthy subjects who were asked to focus on just one stimulus at a time.ResumoTexthttp://repositorio.ufes.br/handle/10/9719engUniversidade Federal do Espírito SantoDoutorado em Engenharia ElétricaPrograma de Pós-Graduação em Engenharia ElétricaUFESBRCentro TecnológicoSinais cerebraisInteração homem-máquinaInterface cérebro-computadorPotencial evocado (Eletrofisiologia)Profundidade – PercepçãoComunicação não-verbalEletrônica Industrial, Sistemas e Controles Eletrônicos621.3A novel stimulation paradigm for a brain-computer interface based on SSVEPinfo:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/doctoralThesisinfo:eu-repo/semantics/openAccessreponame:Repositório Institucional da Universidade Federal do Espírito Santo (riUfes)instname:Universidade Federal do Espírito Santo (UFES)instacron:UFESORIGINALtese_5146_Tese Anibal Cotrina Atencio20160413-94207.pdfapplication/pdf18045911http://repositorio.ufes.br/bitstreams/f9e54f02-f5cd-45dc-acdb-5e7cfeffc7e9/download2e54a921fab59f7fa26a089e26928f91MD5110/97192024-07-17 17:00:49.791oai:repositorio.ufes.br:10/9719http://repositorio.ufes.brRepositório InstitucionalPUBhttp://repositorio.ufes.br/oai/requestopendoar:21082024-10-15T17:59:01.473379Repositório Institucional da Universidade Federal do Espírito Santo (riUfes) - Universidade Federal do Espírito Santo (UFES)false
dc.title.none.fl_str_mv A novel stimulation paradigm for a brain-computer interface based on SSVEP
title A novel stimulation paradigm for a brain-computer interface based on SSVEP
spellingShingle A novel stimulation paradigm for a brain-computer interface based on SSVEP
Atencio, Anibal Cotrina
Sinais cerebrais
Eletrônica Industrial, Sistemas e Controles Eletrônicos
Interação homem-máquina
Interface cérebro-computador
Potencial evocado (Eletrofisiologia)
Profundidade – Percepção
Comunicação não-verbal
621.3
title_short A novel stimulation paradigm for a brain-computer interface based on SSVEP
title_full A novel stimulation paradigm for a brain-computer interface based on SSVEP
title_fullStr A novel stimulation paradigm for a brain-computer interface based on SSVEP
title_full_unstemmed A novel stimulation paradigm for a brain-computer interface based on SSVEP
title_sort A novel stimulation paradigm for a brain-computer interface based on SSVEP
author Atencio, Anibal Cotrina
author_facet Atencio, Anibal Cotrina
author_role author
dc.contributor.advisor-co1.fl_str_mv Ferreira, André
dc.contributor.advisor1.fl_str_mv Bastos Filho,Teodiano Freire
dc.contributor.author.fl_str_mv Atencio, Anibal Cotrina
dc.contributor.referee1.fl_str_mv Frizera Neto, Anselmo
dc.contributor.referee2.fl_str_mv Sarcinelli Filho, Mario
dc.contributor.referee3.fl_str_mv Krohling, Renato Antônio
dc.contributor.referee4.fl_str_mv Sá, Antonio Mauricio Ferreira Leite Miranda de
contributor_str_mv Ferreira, André
Bastos Filho,Teodiano Freire
Frizera Neto, Anselmo
Sarcinelli Filho, Mario
Krohling, Renato Antônio
Sá, Antonio Mauricio Ferreira Leite Miranda de
dc.subject.por.fl_str_mv Sinais cerebrais
topic Sinais cerebrais
Eletrônica Industrial, Sistemas e Controles Eletrônicos
Interação homem-máquina
Interface cérebro-computador
Potencial evocado (Eletrofisiologia)
Profundidade – Percepção
Comunicação não-verbal
621.3
dc.subject.cnpq.fl_str_mv Eletrônica Industrial, Sistemas e Controles Eletrônicos
dc.subject.br-rjbn.none.fl_str_mv Interação homem-máquina
Interface cérebro-computador
Potencial evocado (Eletrofisiologia)
Profundidade – Percepção
Comunicação não-verbal
dc.subject.udc.none.fl_str_mv 621.3
description Brain-computer interfaces (BCIs) are systems that provide a direct connection between users’ brain signals and a computer, generating an alternative channel of communication that does not involve the traditional way as muscles and nerves. They help to restore or replace useful functions of people with paralysis. For instance, BCI systems based on SSVEP (SSVEP-BCI) present a set of stimuli flickering at different frequencies to the users, detect which stimulus is being gazed and associate this information to commands that can be used to control a robotic wheelchair, an exoskeleton, or a speller. Nowadays, SSVEP-BCIs are being widely used due to the high SNR of their response that is achieved when the target stimulus is brought to the center of the user’s field of view. Paradoxically, it is their main disadvantage because bringing a stimulus to the center of the field of view demands muscular activity making them not suitably for paralyzed people who cannot control their head, neck and/or eyeball movements for redirecting their gaze. In optical systems, the range of distance near the point of focus where objects are perceived sharp is referred as Depth-of-field; objects outside this region are defocused and blurred. The mechanism of the visual system that adjusts the eye focal length for focusing does not demand neck, head and/or eyeball movements. Furthermore, ophthalmology studies state that the amplitude and the latency of visual evoked potentials are affected by defocusing. In this context, this Thesis proposes a novel SSVEP-BCI paradigm, in which two stimuli are presented together in the center of the user’s field of view but at different distances from him, ensuring that if one stimulus is focused on, the other one is non-focused, and vice versa; with the aim of providing an alternative way of sending commands through a stimuli selection by a focusing mechanism. In this sense, first, a model of VEP generation for two stimuli is introduced and the hypothesis that distinguishable SSVEP can be elicited by the focused stimulus, regardless of the non-focused stimulus is also present, is tested by employing the SFT-based ORD. Next, a demodulation method based in LPF and HPF is proposed for the case in that two stimuli are present in the field of view; and spatial-temporal retinal response for flickering stimuli is described by using PSF and NPSF functions. Finally, CCA, PSDA, LASSO with EEG signals re-referenced at Pz and CAR are employed to detect the SSVEP pattern. Accuracy rate, Kappa coefficient, AUC, and ITR are used to evaluate the detection performance. As a result of the hypothesis test, the absence of evoked potentials due to a focused stimulus, when a non-focused stimulus is also present was rejected in most of the cases. In SSVEP detection experiments, an average accuracy rate of 0.93 was achieved for a time window of 7s and for eight healthy subjects who were asked to focus on just one stimulus at a time.
publishDate 2015
dc.date.issued.fl_str_mv 2015-11-30
dc.date.accessioned.fl_str_mv 2018-08-02T00:02:02Z
dc.date.available.fl_str_mv 2018-08-01
2018-08-02T00:02:02Z
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
dc.type.driver.fl_str_mv info:eu-repo/semantics/doctoralThesis
format doctoralThesis
status_str publishedVersion
dc.identifier.uri.fl_str_mv http://repositorio.ufes.br/handle/10/9719
url http://repositorio.ufes.br/handle/10/9719
dc.language.iso.fl_str_mv eng
language eng
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv Text
dc.publisher.none.fl_str_mv Universidade Federal do Espírito Santo
Doutorado em Engenharia Elétrica
dc.publisher.program.fl_str_mv Programa de Pós-Graduação em Engenharia Elétrica
dc.publisher.initials.fl_str_mv UFES
dc.publisher.country.fl_str_mv BR
dc.publisher.department.fl_str_mv Centro Tecnológico
publisher.none.fl_str_mv Universidade Federal do Espírito Santo
Doutorado em Engenharia Elétrica
dc.source.none.fl_str_mv reponame:Repositório Institucional da Universidade Federal do Espírito Santo (riUfes)
instname:Universidade Federal do Espírito Santo (UFES)
instacron:UFES
instname_str Universidade Federal do Espírito Santo (UFES)
instacron_str UFES
institution UFES
reponame_str Repositório Institucional da Universidade Federal do Espírito Santo (riUfes)
collection Repositório Institucional da Universidade Federal do Espírito Santo (riUfes)
bitstream.url.fl_str_mv http://repositorio.ufes.br/bitstreams/f9e54f02-f5cd-45dc-acdb-5e7cfeffc7e9/download
bitstream.checksum.fl_str_mv 2e54a921fab59f7fa26a089e26928f91
bitstream.checksumAlgorithm.fl_str_mv MD5
repository.name.fl_str_mv Repositório Institucional da Universidade Federal do Espírito Santo (riUfes) - Universidade Federal do Espírito Santo (UFES)
repository.mail.fl_str_mv
_version_ 1813022553105498112