Torque de inserção e força de arrancamento de mini-implantes ortodônticos

Detalhes bibliográficos
Autor(a) principal: Kitahara-céia, Flávia Mitiko Fernandes
Data de Publicação: 2009
Tipo de documento: Dissertação
Idioma: por
Título da fonte: Repositório Institucional da Universidade Federal Fluminense (RIUFF)
Texto Completo: https://app.uff.br/riuff/handle/1/20316
Resumo: Introduction: Different configurations of mini-implants screw can influence the torque of insertion, the pullout strength and consequently, the primary stability. The objective was to evaluate the insertion torque and pullout strength of five types of mini-implants. Material and Method: Were obtained images of the mini-implants active points (STEMI 2000-C and MEV) and analyzed by the Axio Vision program (Zeiss, Jena, Germany). Five mini-implants in each group: NEO(Neodent), SIN, CON (Connection), DEN (Dentaurum) and RMO were inserted into porcine rib and the insertion torque recorded by the Lutron 101 software. The tensile test was carried out in the Universal Machine Emic DL 10000 (100kgf/0.05mm/sec). Results: The torque of insertion ranged from 6.40 Ncm to 14.60 Ncm, with a statistically significant difference between groups and RMO DEN, and DEN, CON, NEO and CON; and NEO and RMO. The pullout strength ranged between 136.45 N and 227.30 N, and there was no statistically significant difference between groups. Conclusions: Different mini implants showed active spikes with different characteristics. The torque of insertion was directly proportional to the number of threads and inversely to the fillet angle and bottom of the threads (p<0.05). The structural features of mini-implants did not affect the pullout strength, with no difference between groups (p> 0.05).
id UFF-2_8d0df5cd14f2acb9b1f9bb260e9aa9c2
oai_identifier_str oai:app.uff.br:1/20316
network_acronym_str UFF-2
network_name_str Repositório Institucional da Universidade Federal Fluminense (RIUFF)
repository_id_str 2120
spelling Torque de inserção e força de arrancamento de mini-implantes ortodônticosThe insertion torque and pullout strength of orthodontic mini-implantsImplantação DentáriaDental ImplantationCNPQ::CIENCIAS DA SAUDE::ODONTOLOGIA::ORTODONTIAIntroduction: Different configurations of mini-implants screw can influence the torque of insertion, the pullout strength and consequently, the primary stability. The objective was to evaluate the insertion torque and pullout strength of five types of mini-implants. Material and Method: Were obtained images of the mini-implants active points (STEMI 2000-C and MEV) and analyzed by the Axio Vision program (Zeiss, Jena, Germany). Five mini-implants in each group: NEO(Neodent), SIN, CON (Connection), DEN (Dentaurum) and RMO were inserted into porcine rib and the insertion torque recorded by the Lutron 101 software. The tensile test was carried out in the Universal Machine Emic DL 10000 (100kgf/0.05mm/sec). Results: The torque of insertion ranged from 6.40 Ncm to 14.60 Ncm, with a statistically significant difference between groups and RMO DEN, and DEN, CON, NEO and CON; and NEO and RMO. The pullout strength ranged between 136.45 N and 227.30 N, and there was no statistically significant difference between groups. Conclusions: Different mini implants showed active spikes with different characteristics. The torque of insertion was directly proportional to the number of threads and inversely to the fillet angle and bottom of the threads (p<0.05). The structural features of mini-implants did not affect the pullout strength, with no difference between groups (p> 0.05).Introdução: Diferentes configurações de filete de mini-implantes podem influenciar no torque de inserção, na força de arrancamento e conseqüentemente, na estabilidade primária. Objetivou-se avaliar torque de inserção e força de arrancamento de cinco tipos de mini-implantes. Material e Método: Foram obtidas imagens das pontas ativas dos mini-implantes (Stemi 2000-C e do MEV) e analisadas através do programa Axio Vision (Zeiss, Jena, Alemanha). Cinco mini-implantes de cada grupo (Neodent-NEO, SIN, Conexão-CON, Dentaurum-DEN e RMO) foram inseridos em costela suína e o torque de inserção registrado pelo programa Lutron 101. O ensaio à tração foi realizado em máquina Universal Emic DL 10000 (100kgf/0,05mm/seg). Resultados: O torque de inserção variou de 6,40Ncm a 14,60Ncm, com diferença estatisticamente significativa entre os grupos DEN e RMO; DEN e CON; NEO e CON e; NEO e RMO. A força de arrancamento variou entre 136,45N e 227,30N, não houve diferença estatisticamente significativa entre os grupos. Conclusões: Diferentes mini-implantes apresentaram pontas ativas com características distintas. O torque de inserção se mostrou diretamente proporcional ao número de filetes e inversamente ao passo, ângulo e fundo do filete (p<0,05). As características estruturais dos mini-implantes não influenciaram na força de arrancamento, não havendo diferença entre os grupos (p>0,05).Programa de Pós-graduação em OdontologiaClínica OdontológicaMucha, José NelsonCPF:39741263222http://lattes.cnpq.br/3974126320534425Elias, Carlos NelsonCPF:02345656622http://buscatextual.cnpq.br/buscatextual/visualizacv.do?id=K4780835D8Kitahara-céia, Flávia Mitiko Fernandes2021-03-10T20:49:53Z2013-10-302021-03-10T20:49:53Z2009-01-02info:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/masterThesisapplication/pdfhttps://app.uff.br/riuff/handle/1/20316porCC-BY-SAinfo:eu-repo/semantics/openAccessreponame:Repositório Institucional da Universidade Federal Fluminense (RIUFF)instname:Universidade Federal Fluminense (UFF)instacron:UFF2021-03-10T20:49:53Zoai:app.uff.br:1/20316Repositório InstitucionalPUBhttps://app.uff.br/oai/requestriuff@id.uff.bropendoar:21202021-03-10T20:49:53Repositório Institucional da Universidade Federal Fluminense (RIUFF) - Universidade Federal Fluminense (UFF)false
dc.title.none.fl_str_mv Torque de inserção e força de arrancamento de mini-implantes ortodônticos
The insertion torque and pullout strength of orthodontic mini-implants
title Torque de inserção e força de arrancamento de mini-implantes ortodônticos
spellingShingle Torque de inserção e força de arrancamento de mini-implantes ortodônticos
Kitahara-céia, Flávia Mitiko Fernandes
Implantação Dentária
Dental Implantation
CNPQ::CIENCIAS DA SAUDE::ODONTOLOGIA::ORTODONTIA
title_short Torque de inserção e força de arrancamento de mini-implantes ortodônticos
title_full Torque de inserção e força de arrancamento de mini-implantes ortodônticos
title_fullStr Torque de inserção e força de arrancamento de mini-implantes ortodônticos
title_full_unstemmed Torque de inserção e força de arrancamento de mini-implantes ortodônticos
title_sort Torque de inserção e força de arrancamento de mini-implantes ortodônticos
author Kitahara-céia, Flávia Mitiko Fernandes
author_facet Kitahara-céia, Flávia Mitiko Fernandes
author_role author
dc.contributor.none.fl_str_mv Mucha, José Nelson
CPF:39741263222
http://lattes.cnpq.br/3974126320534425
Elias, Carlos Nelson
CPF:02345656622
http://buscatextual.cnpq.br/buscatextual/visualizacv.do?id=K4780835D8
dc.contributor.author.fl_str_mv Kitahara-céia, Flávia Mitiko Fernandes
dc.subject.por.fl_str_mv Implantação Dentária
Dental Implantation
CNPQ::CIENCIAS DA SAUDE::ODONTOLOGIA::ORTODONTIA
topic Implantação Dentária
Dental Implantation
CNPQ::CIENCIAS DA SAUDE::ODONTOLOGIA::ORTODONTIA
description Introduction: Different configurations of mini-implants screw can influence the torque of insertion, the pullout strength and consequently, the primary stability. The objective was to evaluate the insertion torque and pullout strength of five types of mini-implants. Material and Method: Were obtained images of the mini-implants active points (STEMI 2000-C and MEV) and analyzed by the Axio Vision program (Zeiss, Jena, Germany). Five mini-implants in each group: NEO(Neodent), SIN, CON (Connection), DEN (Dentaurum) and RMO were inserted into porcine rib and the insertion torque recorded by the Lutron 101 software. The tensile test was carried out in the Universal Machine Emic DL 10000 (100kgf/0.05mm/sec). Results: The torque of insertion ranged from 6.40 Ncm to 14.60 Ncm, with a statistically significant difference between groups and RMO DEN, and DEN, CON, NEO and CON; and NEO and RMO. The pullout strength ranged between 136.45 N and 227.30 N, and there was no statistically significant difference between groups. Conclusions: Different mini implants showed active spikes with different characteristics. The torque of insertion was directly proportional to the number of threads and inversely to the fillet angle and bottom of the threads (p<0.05). The structural features of mini-implants did not affect the pullout strength, with no difference between groups (p> 0.05).
publishDate 2009
dc.date.none.fl_str_mv 2009-01-02
2013-10-30
2021-03-10T20:49:53Z
2021-03-10T20:49:53Z
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
dc.type.driver.fl_str_mv info:eu-repo/semantics/masterThesis
format masterThesis
status_str publishedVersion
dc.identifier.uri.fl_str_mv https://app.uff.br/riuff/handle/1/20316
url https://app.uff.br/riuff/handle/1/20316
dc.language.iso.fl_str_mv por
language por
dc.rights.driver.fl_str_mv CC-BY-SA
info:eu-repo/semantics/openAccess
rights_invalid_str_mv CC-BY-SA
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv application/pdf
dc.publisher.none.fl_str_mv Programa de Pós-graduação em Odontologia
Clínica Odontológica
publisher.none.fl_str_mv Programa de Pós-graduação em Odontologia
Clínica Odontológica
dc.source.none.fl_str_mv reponame:Repositório Institucional da Universidade Federal Fluminense (RIUFF)
instname:Universidade Federal Fluminense (UFF)
instacron:UFF
instname_str Universidade Federal Fluminense (UFF)
instacron_str UFF
institution UFF
reponame_str Repositório Institucional da Universidade Federal Fluminense (RIUFF)
collection Repositório Institucional da Universidade Federal Fluminense (RIUFF)
repository.name.fl_str_mv Repositório Institucional da Universidade Federal Fluminense (RIUFF) - Universidade Federal Fluminense (UFF)
repository.mail.fl_str_mv riuff@id.uff.br
_version_ 1807838840891637760