Ventilator associated pneumonia agents in brazilian neonatal intense care units: a systematic review
Autor(a) principal: | |
---|---|
Data de Publicação: | 2018 |
Outros Autores: | , , , |
Tipo de documento: | Artigo |
Idioma: | eng |
Título da fonte: | Repositório Institucional da Universidade Federal Fluminense (RIUFF) |
Texto Completo: | http://app.uff.br/riuff/handle/1/28837 |
Resumo: | Sim |
id |
UFF-2_9ead0012bb852f8d950c6a64731f6aa5 |
---|---|
oai_identifier_str |
oai:app.uff.br:1/28837 |
network_acronym_str |
UFF-2 |
network_name_str |
Repositório Institucional da Universidade Federal Fluminense (RIUFF) |
repository_id_str |
2120 |
spelling |
Ventilator associated pneumonia agents in brazilian neonatal intense care units: a systematic reviewVentilator associated pneumonia agents in brazilian neonatal intense care units: a systematic reviewRevisão bibliográficaPneumoniaRespiração artificialRecém-nascidoNoxaSystematic reviewsVentilator-associated pneumoniaNewbornEtiological agentsSimIntroduction: Ventilator-associated pneumonia (VAP) is one of the most common healthcare-associated infections (HAI) in neonates admitted in neonatal intensive care units (NICUs). Methods: We did a systematic review using PRISMA methodology to identify the main etiological agents in Brazilian NICUs. Eligible studies published without period restriction were identified in PUBMED, SCIELO, LILACS and DOAJ. Studies were included if they were conducted in neonates hospitalized at NICU. Studies done in outpatient care, neonates outside NICU, emergency department, primary care, long-term care facilities or a combination of these were excluded. Results: We identified 6384 articles in the initial search and four papers met the inclusion criteria. In all studies included, rates of device-associated infections were described, including VAP rates. The VAP incidence density, in exclusively Brazilian NICU, ranged from 3.2 to 9.2 per 1000 ventilator-days. Pneumonia was described as the main HAI in NICU in one article, as the second type of HAI in two other articles and as the fourth type of HAI in the last one. The main pathogens causing all HAI types were described in three of four articles, but, none of the articles reported which pathogens were related or associated to VAP. Conclusion: Etiological agents causing VAP in Brazilian NICUs are, until the present time, not known.SBINiterói, RJ2023-05-16T12:10:54Z2023-05-16T12:10:54Z2018info:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/articleapplication/pdfSILVA, André Ricardo Araujo da et al. Ventilator-associated pneumonia agents in brazilian neonatal intensive care units: a systematic review. Brazilian Journal of Infectious Diseases, v. 22, n. 4, p. 338-344, Jul-Aug 2018.http://app.uff.br/riuff/handle/1/28837Aluno de Graduaçãodoi.org/10.1016/j.bjid.2018.06.002THE BRAZILIAN JOURNAL OF INFECTIOUS DISEASES. São Paulo: SBI, 2013-2023. Bimestral. ISSN: 1413-8670.CC-BY-SAinfo:eu-repo/semantics/openAccessSilva, André Ricardo Araujo daSilva, Thais Carolina daBom, Gabriel José TeixeiraVasconcelos, Raissa Maria BastosSimões Junior, Robinsonengreponame:Repositório Institucional da Universidade Federal Fluminense (RIUFF)instname:Universidade Federal Fluminense (UFF)instacron:UFF2023-10-05T15:18:26Zoai:app.uff.br:1/28837Repositório InstitucionalPUBhttps://app.uff.br/oai/requestriuff@id.uff.bropendoar:21202024-08-19T11:14:09.063587Repositório Institucional da Universidade Federal Fluminense (RIUFF) - Universidade Federal Fluminense (UFF)false |
dc.title.none.fl_str_mv |
Ventilator associated pneumonia agents in brazilian neonatal intense care units: a systematic review Ventilator associated pneumonia agents in brazilian neonatal intense care units: a systematic review |
title |
Ventilator associated pneumonia agents in brazilian neonatal intense care units: a systematic review |
spellingShingle |
Ventilator associated pneumonia agents in brazilian neonatal intense care units: a systematic review Silva, André Ricardo Araujo da Revisão bibliográfica Pneumonia Respiração artificial Recém-nascido Noxa Systematic reviews Ventilator-associated pneumonia Newborn Etiological agents |
title_short |
Ventilator associated pneumonia agents in brazilian neonatal intense care units: a systematic review |
title_full |
Ventilator associated pneumonia agents in brazilian neonatal intense care units: a systematic review |
title_fullStr |
Ventilator associated pneumonia agents in brazilian neonatal intense care units: a systematic review |
title_full_unstemmed |
Ventilator associated pneumonia agents in brazilian neonatal intense care units: a systematic review |
title_sort |
Ventilator associated pneumonia agents in brazilian neonatal intense care units: a systematic review |
author |
Silva, André Ricardo Araujo da |
author_facet |
Silva, André Ricardo Araujo da Silva, Thais Carolina da Bom, Gabriel José Teixeira Vasconcelos, Raissa Maria Bastos Simões Junior, Robinson |
author_role |
author |
author2 |
Silva, Thais Carolina da Bom, Gabriel José Teixeira Vasconcelos, Raissa Maria Bastos Simões Junior, Robinson |
author2_role |
author author author author |
dc.contributor.author.fl_str_mv |
Silva, André Ricardo Araujo da Silva, Thais Carolina da Bom, Gabriel José Teixeira Vasconcelos, Raissa Maria Bastos Simões Junior, Robinson |
dc.subject.por.fl_str_mv |
Revisão bibliográfica Pneumonia Respiração artificial Recém-nascido Noxa Systematic reviews Ventilator-associated pneumonia Newborn Etiological agents |
topic |
Revisão bibliográfica Pneumonia Respiração artificial Recém-nascido Noxa Systematic reviews Ventilator-associated pneumonia Newborn Etiological agents |
description |
Sim |
publishDate |
2018 |
dc.date.none.fl_str_mv |
2018 2023-05-16T12:10:54Z 2023-05-16T12:10:54Z |
dc.type.status.fl_str_mv |
info:eu-repo/semantics/publishedVersion |
dc.type.driver.fl_str_mv |
info:eu-repo/semantics/article |
format |
article |
status_str |
publishedVersion |
dc.identifier.uri.fl_str_mv |
SILVA, André Ricardo Araujo da et al. Ventilator-associated pneumonia agents in brazilian neonatal intensive care units: a systematic review. Brazilian Journal of Infectious Diseases, v. 22, n. 4, p. 338-344, Jul-Aug 2018. http://app.uff.br/riuff/handle/1/28837 Aluno de Graduação doi.org/10.1016/j.bjid.2018.06.002 |
identifier_str_mv |
SILVA, André Ricardo Araujo da et al. Ventilator-associated pneumonia agents in brazilian neonatal intensive care units: a systematic review. Brazilian Journal of Infectious Diseases, v. 22, n. 4, p. 338-344, Jul-Aug 2018. Aluno de Graduação doi.org/10.1016/j.bjid.2018.06.002 |
url |
http://app.uff.br/riuff/handle/1/28837 |
dc.language.iso.fl_str_mv |
eng |
language |
eng |
dc.relation.none.fl_str_mv |
THE BRAZILIAN JOURNAL OF INFECTIOUS DISEASES. São Paulo: SBI, 2013-2023. Bimestral. ISSN: 1413-8670. |
dc.rights.driver.fl_str_mv |
CC-BY-SA info:eu-repo/semantics/openAccess |
rights_invalid_str_mv |
CC-BY-SA |
eu_rights_str_mv |
openAccess |
dc.format.none.fl_str_mv |
application/pdf |
dc.publisher.none.fl_str_mv |
SBI Niterói, RJ |
publisher.none.fl_str_mv |
SBI Niterói, RJ |
dc.source.none.fl_str_mv |
reponame:Repositório Institucional da Universidade Federal Fluminense (RIUFF) instname:Universidade Federal Fluminense (UFF) instacron:UFF |
instname_str |
Universidade Federal Fluminense (UFF) |
instacron_str |
UFF |
institution |
UFF |
reponame_str |
Repositório Institucional da Universidade Federal Fluminense (RIUFF) |
collection |
Repositório Institucional da Universidade Federal Fluminense (RIUFF) |
repository.name.fl_str_mv |
Repositório Institucional da Universidade Federal Fluminense (RIUFF) - Universidade Federal Fluminense (UFF) |
repository.mail.fl_str_mv |
riuff@id.uff.br |
_version_ |
1811823697914232832 |